Skip to main content
Erschienen in: European Radiology 11/2003

01.11.2003 | Magnetic Resonance

Principles and applications of balanced SSFP techniques

verfasst von: Klaus Scheffler, Stefan Lehnhardt

Erschienen in: European Radiology | Ausgabe 11/2003

Einloggen, um Zugang zu erhalten

Abstract

During the past 5 years balanced steady-state free precession (SSFP) has become increasingly important for diagnostic and functional imaging. Balanced SSFP is characterized by two unique features: it offers a very high signal-to noise ratio and a T2/T1-weighted image contrast. This article focuses on the physical principles, on the signal formation, and on the resulting properties of balanced SSFP. Mechanisms for contrast modification, recent clinical application, and potential extensions of this technique are discussed.
Literatur
2.
Zurück zum Zitat Carr HY (1958) Steady-state free precession in nuclear magnetic resonance. Phys Rev 112:1693–1701CrossRef Carr HY (1958) Steady-state free precession in nuclear magnetic resonance. Phys Rev 112:1693–1701CrossRef
3.
Zurück zum Zitat Oppelt A, Graumann R, Barfuss H, Fischer H, Hartl W, Schajor W (1986) FISP: a new fast MRI sequence. Electromedica (Engl Ed) 54:15–18 Oppelt A, Graumann R, Barfuss H, Fischer H, Hartl W, Schajor W (1986) FISP: a new fast MRI sequence. Electromedica (Engl Ed) 54:15–18
4.
Zurück zum Zitat Scheffler K (1999) A pictorial description of steady states in fast magnetic resonance imaging: concept. Magn Res 11:291–304 Scheffler K (1999) A pictorial description of steady states in fast magnetic resonance imaging: concept. Magn Res 11:291–304
5.
Zurück zum Zitat Deimling M, Heid O (1994) Magnetization prepared true FISP imaging. In: Proc Second Annual Meeting of the Society of Magnetic Resonance, San Francisco, p 495 Deimling M, Heid O (1994) Magnetization prepared true FISP imaging. In: Proc Second Annual Meeting of the Society of Magnetic Resonance, San Francisco, p 495
6.
Zurück zum Zitat Freeman R, Hill HDW (1971) Phase and intensity anomalities in Fourier transform NMR. J Magn Reson 4:366–383 Freeman R, Hill HDW (1971) Phase and intensity anomalities in Fourier transform NMR. J Magn Reson 4:366–383
7.
Zurück zum Zitat Zur Y, Stokar S, Bendel P (1988) An analysis of fast imaging sequences with steady-state transverse magnetization refocusing. Magn Reson Med 6:17–193CrossRef Zur Y, Stokar S, Bendel P (1988) An analysis of fast imaging sequences with steady-state transverse magnetization refocusing. Magn Reson Med 6:17–193CrossRef
8.
Zurück zum Zitat Haacke EM, Brown RW, Thompson MR, Venkatesan R (1999) In: Magnetic resonance imaging: physical principles and sequence design. Mosby, St. Louis, chap. 18 Haacke EM, Brown RW, Thompson MR, Venkatesan R (1999) In: Magnetic resonance imaging: physical principles and sequence design. Mosby, St. Louis, chap. 18
9.
Zurück zum Zitat Scheffler K. Hennig J (2003) Is TrueFISP a spin-echo or gradient-echo sequence? Magn Reson Med 49:395–397CrossRef Scheffler K. Hennig J (2003) Is TrueFISP a spin-echo or gradient-echo sequence? Magn Reson Med 49:395–397CrossRef
10.
Zurück zum Zitat Schaeffter T, Weiss S, Börnert P (2002) A SAR-reduced steady-state free precessing (SSFP) acquisition. Proc ISMRM, Honolulu, p 2351 Schaeffter T, Weiss S, Börnert P (2002) A SAR-reduced steady-state free precessing (SSFP) acquisition. Proc ISMRM, Honolulu, p 2351
11.
Zurück zum Zitat Haase A (1990) Snapshot FLASH MRI: applications to T1, T2, and chemical-shift imaging. Magn Reson Med 13:77–89CrossRef Haase A (1990) Snapshot FLASH MRI: applications to T1, T2, and chemical-shift imaging. Magn Reson Med 13:77–89CrossRef
12.
Zurück zum Zitat Norris D, Börnert P, Reese T, Leibfritz D (1992) On the application of ultra-fast RARE experiments. Magn Reson Med 27:142–164CrossRef Norris D, Börnert P, Reese T, Leibfritz D (1992) On the application of ultra-fast RARE experiments. Magn Reson Med 27:142–164CrossRef
13.
Zurück zum Zitat Scheffler K, Hennig J (2001) T1 quantification with inversion recovery TrueFISP. Magn Reson Med 45:720–723CrossRef Scheffler K, Hennig J (2001) T1 quantification with inversion recovery TrueFISP. Magn Reson Med 45:720–723CrossRef
14.
Zurück zum Zitat Scheffler K, Thiel T, Thesen S (2002) Assessment of perfusion with arterial spin labeling and TrueFISP. Proc ISMRM, Honolulu, p 628 Scheffler K, Thiel T, Thesen S (2002) Assessment of perfusion with arterial spin labeling and TrueFISP. Proc ISMRM, Honolulu, p 628
15.
Zurück zum Zitat Nishimura DG, Vasanawala SS (2000) Analysis and reduction of the transient response in SSFP imaging. Proc 8th Annual Meeting ISMRM, p 301 Nishimura DG, Vasanawala SS (2000) Analysis and reduction of the transient response in SSFP imaging. Proc 8th Annual Meeting ISMRM, p 301
16.
Zurück zum Zitat Hennig J, Speck O, Scheffler K (2002) Optimization of the signal behavior in the transition to driven equilibrium in steady-state free precession sequences. Magn Reson Med 48:801–809CrossRef Hennig J, Speck O, Scheffler K (2002) Optimization of the signal behavior in the transition to driven equilibrium in steady-state free precession sequences. Magn Reson Med 48:801–809CrossRef
17.
Zurück zum Zitat Hargreaves BA, Vasanawala SS, Pauly JM, Nishimura DG (2001) Characterization and reduction of the transient response in steady-state MR imaging. Magn Reson Med 46:149–158CrossRef Hargreaves BA, Vasanawala SS, Pauly JM, Nishimura DG (2001) Characterization and reduction of the transient response in steady-state MR imaging. Magn Reson Med 46:149–158CrossRef
18.
Zurück zum Zitat Scheffler K, Heid O, Hennig J (2001) Magnetization preparation during the steady state: 3D fat saturated TrueFISP. Magn Reson Med 45:1075–1080CrossRef Scheffler K, Heid O, Hennig J (2001) Magnetization preparation during the steady state: 3D fat saturated TrueFISP. Magn Reson Med 45:1075–1080CrossRef
19.
Zurück zum Zitat Wagner S, Buser P, Auffermann W, Holt WW, Wolfe CL, Higgins CB (1989) Cine magnetic resonance imaging: tomographic analysis of left ventricular function. Cardiol Clin 7:651–659CrossRef Wagner S, Buser P, Auffermann W, Holt WW, Wolfe CL, Higgins CB (1989) Cine magnetic resonance imaging: tomographic analysis of left ventricular function. Cardiol Clin 7:651–659CrossRef
20.
Zurück zum Zitat Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF (2001) MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology 219:264–269CrossRef Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF (2001) MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology 219:264–269CrossRef
21.
Zurück zum Zitat Jung BA, Hennig J, Scheffler K (2002) Single-breathhold 3D-trueFISP cine cardiac imaging. Magn Reson Med 48:921–925CrossRef Jung BA, Hennig J, Scheffler K (2002) Single-breathhold 3D-trueFISP cine cardiac imaging. Magn Reson Med 48:921–925CrossRef
22.
Zurück zum Zitat Deshpande VS, Shea SM, Laub G, Simonetti OP, Finn JP, Li D (2001) 3D magnetization-prepared TrueFISP: a new technique for imaging coronary arteries. Magn Reson Med 46:494–502CrossRef Deshpande VS, Shea SM, Laub G, Simonetti OP, Finn JP, Li D (2001) 3D magnetization-prepared TrueFISP: a new technique for imaging coronary arteries. Magn Reson Med 46:494–502CrossRef
23.
Zurück zum Zitat Leupold J,Hennig J, Scheffler K (2002) 3D time-of-flight MRI using inversion recovery TrueFISP. Proc ISMRM, Honolulu, p 138 Leupold J,Hennig J, Scheffler K (2002) 3D time-of-flight MRI using inversion recovery TrueFISP. Proc ISMRM, Honolulu, p 138
24.
Zurück zum Zitat Scheffler K, Winterer JT, Langer M, Hennig J (2002) Contrast-enhanced angiography using T1-weighted TrueFISP. Proc ISMRM, Honolulu, p 139 Scheffler K, Winterer JT, Langer M, Hennig J (2002) Contrast-enhanced angiography using T1-weighted TrueFISP. Proc ISMRM, Honolulu, p 139
25.
Zurück zum Zitat Amartur SC, Wielopolski PA, Kormos DW, Modic MT, Clampitt M (1991) Tissue segmentation for three-dimensional display of human spines. Med Phys 18:305–308CrossRef Amartur SC, Wielopolski PA, Kormos DW, Modic MT, Clampitt M (1991) Tissue segmentation for three-dimensional display of human spines. Med Phys 18:305–308CrossRef
26.
Zurück zum Zitat Lienemann A, Anthuber C, Baron A, Kohz P, Reiser M (1997) Dynamic MR colpocystorectography assessing pelvic-floor descent. Eur Radiol 7:1309–1317CrossRef Lienemann A, Anthuber C, Baron A, Kohz P, Reiser M (1997) Dynamic MR colpocystorectography assessing pelvic-floor descent. Eur Radiol 7:1309–1317CrossRef
27.
Zurück zum Zitat Overall WR, Conolly SM, Nishimura DG, Hu BS (2002) Oscillating dual-equilibrium steady-state angiography. Magn Reson Med 47:513–522CrossRef Overall WR, Conolly SM, Nishimura DG, Hu BS (2002) Oscillating dual-equilibrium steady-state angiography. Magn Reson Med 47:513–522CrossRef
28.
Zurück zum Zitat Vasanawala SS, Pauly JM, Nishimura DG (2000) Linear combination steady-state free precession MRI. Magn Reson Med 43:82–90CrossRef Vasanawala SS, Pauly JM, Nishimura DG (2000) Linear combination steady-state free precession MRI. Magn Reson Med 43:82–90CrossRef
29.
Zurück zum Zitat Hardy CJ, Dixon WT (2002) Steady-state free precession imaging with inherent fat suppression. Proc ISMRM, Honolulu, p 473 Hardy CJ, Dixon WT (2002) Steady-state free precession imaging with inherent fat suppression. Proc ISMRM, Honolulu, p 473
30.
Zurück zum Zitat Petsch R, Helmberger T, Reiser M (1999) New techniques and pulse sequences in MRI of the liver. Radiologe 39:662–670CrossRef Petsch R, Helmberger T, Reiser M (1999) New techniques and pulse sequences in MRI of the liver. Radiologe 39:662–670CrossRef
31.
Zurück zum Zitat Herborn CU, Vogt F, Lauenstein TC, Goyen M, Debatin JF, Ruehm SG (2003) MRI of the liver: Can TrueFISP replace HASTE? J Magn Reson Med 17:190–196 Herborn CU, Vogt F, Lauenstein TC, Goyen M, Debatin JF, Ruehm SG (2003) MRI of the liver: Can TrueFISP replace HASTE? J Magn Reson Med 17:190–196
32.
Zurück zum Zitat Rieber A, Aschoff A, Brambs HJ (2000) MRI in the diagnosis of small bowel disease: use of positive and negative oral contrast media in combination with enteroclysis. Eur Radiol 10:1377–1382CrossRef Rieber A, Aschoff A, Brambs HJ (2000) MRI in the diagnosis of small bowel disease: use of positive and negative oral contrast media in combination with enteroclysis. Eur Radiol 10:1377–1382CrossRef
Metadaten
Titel
Principles and applications of balanced SSFP techniques
verfasst von
Klaus Scheffler
Stefan Lehnhardt
Publikationsdatum
01.11.2003
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 11/2003
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-1957-x

Weitere Artikel der Ausgabe 11/2003

European Radiology 11/2003 Zur Ausgabe

Calendar of events

November 2003

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.