Self-expanding nitinol stents: material and design considerations

verfasst von: Dieter Stoeckel, Alan Pelton, Tom Duerig

Erschienen in: European Radiology | Ausgabe 2/2004

Einloggen, um Zugang zu erhalten

Abstract

Nitinol (nickel–titanium) alloys exhibit a combination of properties which make these alloys particularly suited for self-expanding stents. Some of these properties cannot be found in engineering materials used for stents presently. This article explains the fundamental mechanism of shape memory and superelasticity, and how they relate to the characteristic performance of self-expanding stents. Nitinol stents are manufactured to a size slightly larger than the target vessel size and delivered constrained in a delivery system. After deployment, they position themselves against the vessel wall with a low, "chronic" outward force. They resist outside forces with a significantly higher radial resistive force. Despite the high nickel content of Nitinol, its corrosion resistance and biocompatibility is equal to that of other implant materials. The most common Nitinol stents are listed and described.
Literatur
1.
Zurück zum Zitat Dotter CT, Buschmann PAC, McKinney MK, Rösch J (1983) Transluminal expandable nitinol coil stent grafting: preliminary report. Radiology 147:259PubMed Dotter CT, Buschmann PAC, McKinney MK, Rösch J (1983) Transluminal expandable nitinol coil stent grafting: preliminary report. Radiology 147:259PubMed
2.
Zurück zum Zitat Shabalovskaya S (1996) On the nature of the biocompatibility and medical applications of NiTi shape memory and superelastic alloys. Bio Med Mat Eng 6:267 Shabalovskaya S (1996) On the nature of the biocompatibility and medical applications of NiTi shape memory and superelastic alloys. Bio Med Mat Eng 6:267
3.
Zurück zum Zitat Duerig TW, Melton KN, Wayman CM, Stöckel D (1990) Engineering aspects of shape-memory alloys. Butterworth-Heinemann, London Duerig TW, Melton KN, Wayman CM, Stöckel D (1990) Engineering aspects of shape-memory alloys. Butterworth-Heinemann, London
4.
Zurück zum Zitat Stoeckel D (2000) Nitinol medical devices and implants. Min Invas Ther Allied Technol 9:81 Stoeckel D (2000) Nitinol medical devices and implants. Min Invas Ther Allied Technol 9:81
5.
Zurück zum Zitat ASTM F 2063–00 (2002) Standard specification for wrought nickel–titanium shape-memory alloys for medical devices and surgical implants ASTM F 2063–00 (2002) Standard specification for wrought nickel–titanium shape-memory alloys for medical devices and surgical implants
6.
Zurück zum Zitat ASTM F 2004–00 (2002) Test method for transformation temperature of nickel-titanium alloys by thermal analysis ASTM F 2004–00 (2002) Test method for transformation temperature of nickel-titanium alloys by thermal analysis
7.
Zurück zum Zitat ASTM F 2082–01 (2002) Method for the determination of transformation temperature of nickel–titanium shape-memory alloys by bend and free recovery ASTM F 2082–01 (2002) Method for the determination of transformation temperature of nickel–titanium shape-memory alloys by bend and free recovery
8.
Zurück zum Zitat Pelton AR, DiCello J, Miyazaki S (2000) Optimisation of processing and properties of medical grade Nitinol wire. Min Invas Ther Allied Technol 9:107 Pelton AR, DiCello J, Miyazaki S (2000) Optimisation of processing and properties of medical grade Nitinol wire. Min Invas Ther Allied Technol 9:107
9.
Zurück zum Zitat Wever DJ, Veldhuizen AG, Sanders MM, Schakenraad JM (1997) Cytotoxic, allergic and genotoxic activity of a nickel–titanium alloy. Biomaterials 18:1115CrossRefPubMed Wever DJ, Veldhuizen AG, Sanders MM, Schakenraad JM (1997) Cytotoxic, allergic and genotoxic activity of a nickel–titanium alloy. Biomaterials 18:1115CrossRefPubMed
10.
Zurück zum Zitat Wever DJ, Veldhuizen AG, de Vries J, Busscher HJ, Uges DRA, van Horn JR (1998) Electrochemical and surface characterization of a nickel–titanium alloy. Biomaterials 19:761CrossRefPubMed Wever DJ, Veldhuizen AG, de Vries J, Busscher HJ, Uges DRA, van Horn JR (1998) Electrochemical and surface characterization of a nickel–titanium alloy. Biomaterials 19:761CrossRefPubMed
11.
Zurück zum Zitat Brown SA, Hughes PJ, Merritt K (1988) In vitro studies of fretting corrosion of orthopaedic materials. J Orthop Res 6:572PubMed Brown SA, Hughes PJ, Merritt K (1988) In vitro studies of fretting corrosion of orthopaedic materials. J Orthop Res 6:572PubMed
12.
Zurück zum Zitat Barrett RD, Bishara SE, Quinn JK (1993) Biodegradation of orthodontic appliances: part I, biodegradation of nickel and chromium in vitro. Am J Orthod Dentofac Orthop 103:8 Barrett RD, Bishara SE, Quinn JK (1993) Biodegradation of orthodontic appliances: part I, biodegradation of nickel and chromium in vitro. Am J Orthod Dentofac Orthop 103:8
13.
Zurück zum Zitat Bishara SE, Barrett RD, Selim MI (1993) Biodegradation of orthodontic appliances. Part II: Changes in the blood level of nickel. Am J Orthod Dentofac Orthop 103:115 Bishara SE, Barrett RD, Selim MI (1993) Biodegradation of orthodontic appliances. Part II: Changes in the blood level of nickel. Am J Orthod Dentofac Orthop 103:115
14.
Zurück zum Zitat Ryhanen J, Niemi E, Serlo W, Niemelä E, Sandvik P, Pernu H, Salo T (1997) Biocompatibility of nickel–titanium shape-memory metal and its corrosion behavior in human cell cultures. J Biomed Mater Res 35:451PubMed Ryhanen J, Niemi E, Serlo W, Niemelä E, Sandvik P, Pernu H, Salo T (1997) Biocompatibility of nickel–titanium shape-memory metal and its corrosion behavior in human cell cultures. J Biomed Mater Res 35:451PubMed
15.
Zurück zum Zitat Trepanier C, Venugopolan R, Messer R, Zimmerman J, Pelton AR (2000) Effect of passivation treatments on nickel release from Nitinol. Proc Soc Biomater:1043 Trepanier C, Venugopolan R, Messer R, Zimmerman J, Pelton AR (2000) Effect of passivation treatments on nickel release from Nitinol. Proc Soc Biomater:1043
16.
Zurück zum Zitat ASTM F2129–01 (2002) Standard test method for conducting cyclic potentiodynamic polarization measurements to determine the corrosion susceptibility of small implant devices ASTM F2129–01 (2002) Standard test method for conducting cyclic potentiodynamic polarization measurements to determine the corrosion susceptibility of small implant devices
17.
Zurück zum Zitat Trepanier C, Tabizian M, Yahia LH, Bilodeau L, Piron DL (1998) Effect of modification of oxide layer on NiTi stent corrosion resistance. J Biomed Mater Res 43:433CrossRefPubMed Trepanier C, Tabizian M, Yahia LH, Bilodeau L, Piron DL (1998) Effect of modification of oxide layer on NiTi stent corrosion resistance. J Biomed Mater Res 43:433CrossRefPubMed
18.
Zurück zum Zitat Trepanier C, Fino J, Zhu L, Pelton AR (2002) Corrosion resistance of oxidized Nitinol. SMST Trepanier C, Fino J, Zhu L, Pelton AR (2002) Corrosion resistance of oxidized Nitinol. SMST
19.
Zurück zum Zitat Heintz C, Riepe G, Birken L, Kaiser E, Chafke N, Morlock M, Delling G, Imig H (2001) Corroded Nitinol wires in explanted aortic endografts: an important mechanism of failure? J Endovasc Ther 8:248PubMed Heintz C, Riepe G, Birken L, Kaiser E, Chafke N, Morlock M, Delling G, Imig H (2001) Corroded Nitinol wires in explanted aortic endografts: an important mechanism of failure? J Endovasc Ther 8:248PubMed
20.
Zurück zum Zitat Kaiser E (2002) Cell-induced corrosion in vitro. Second European Sym Vasc Biomat, Hamburg Kaiser E (2002) Cell-induced corrosion in vitro. Second European Sym Vasc Biomat, Hamburg
21.
Zurück zum Zitat Duerig TW, Pelton AR, Stöckel D (1996) The use of superelasticity in medicine. Metall 50:569 Duerig TW, Pelton AR, Stöckel D (1996) The use of superelasticity in medicine. Metall 50:569
22.
Zurück zum Zitat Duerig TW, Tolomeo DE, Wholey M (2000) An overview of superelastic stent design. Min Invas Ther Allied Technol 9:235 Duerig TW, Tolomeo DE, Wholey M (2000) An overview of superelastic stent design. Min Invas Ther Allied Technol 9:235
23.
Zurück zum Zitat Harnek J, Zoucas E, Stenram U, Cwikiel W (2002) Insertion of self-expandable Nitinol stents without previous balloon angioplasty reduces restenosis compared with PTA prior to stenting. Cardiovasc Intervent Radiol 5:430CrossRef Harnek J, Zoucas E, Stenram U, Cwikiel W (2002) Insertion of self-expandable Nitinol stents without previous balloon angioplasty reduces restenosis compared with PTA prior to stenting. Cardiovasc Intervent Radiol 5:430CrossRef
24.
Zurück zum Zitat Duda S, Wiskirchen J, Tepe G, Bitzer M, Kaulich TW, Stoeckel D, Claussen C (2000) Physical properties of endovascular stents: an experimental comparison. J Vasc Interv Radiol 11:645PubMed Duda S, Wiskirchen J, Tepe G, Bitzer M, Kaulich TW, Stoeckel D, Claussen C (2000) Physical properties of endovascular stents: an experimental comparison. J Vasc Interv Radiol 11:645PubMed
25.
Zurück zum Zitat Sigwart U (1996) The coiled sheet concept. In: Sigwart U (ed) Endoluminal stenting. Saunders, London, pp 249–250 Sigwart U (1996) The coiled sheet concept. In: Sigwart U (ed) Endoluminal stenting. Saunders, London, pp 249–250
26.
Zurück zum Zitat Stoeckel D, Bonsignore C, Duda S (2002) A survey of stent designs. Min Invas Ther Allied Technol 11:137CrossRef Stoeckel D, Bonsignore C, Duda S (2002) A survey of stent designs. Min Invas Ther Allied Technol 11:137CrossRef
Metadaten
Titel
Self-expanding nitinol stents: material and design considerations
verfasst von
Dieter Stoeckel
Alan Pelton
Tom Duerig
Publikationsdatum
01.02.2004
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 2/2004
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-2022-5

Weitere Artikel der Ausgabe 2/2004

European Radiology 2/2004 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.