Skip to main content
Erschienen in: European Radiology 5/2004

01.05.2004 | Magnetic resonance

MR-based full-body preventative cardiovascular and tumor imaging: technique and preliminary experience

verfasst von: Mathias Goyen, Susanne C. Goehde, Christoph U. Herborn, Peter Hunold, Florian M. Vogt, Elke R. Gizewski, Thomas C. Lauenstein, Waleed Ajaj, Michael Forsting, Jörg F. Debatin, Stefan G. Ruehm

Erschienen in: European Radiology | Ausgabe 5/2004

Einloggen, um Zugang zu erhalten

Abstract

Recent improvements in hardware and software, lack of side effects, as well as diagnostic accuracy make magnetic resonance imaging a natural candidate for preventative imaging. Thus, the purpose of the study was to evaluate the feasibility of a comprehensive 60-min MR-based screening examination in healthy volunteers and a limited number of patients with known target disease. In ten healthy volunteers (7 men, 3 women; mean age, 32.4 years) and five patients (4 men, 1 woman; mean age, 56.2 years) with proven target disease we evaluated the performance of a comprehensive MR screening strategy by combining well-established organ-based MR examination components encompassing the brain, the arterial system, the heart, the lungs, and the colon. All ten volunteers and five patients tolerated the comprehensive MR examination well. The mean in-room time was 63 min. In one volunteer, insufficient colonic cleansing on the part of the volunteer diminished the diagnostic reliability of MR colonography. All remaining components of the comprehensive MR examination were considered diagnostic in all volunteers and patients. In the five patients, the examination revealed the known pathologies [aneurysm of the anterior communicating artery (n=1), renal artery stenosis (n=1), myocardial infarct (n=1), and colonic polyp (n=2)]. The outlined MR screening strategy encompassing the brain, the arterial system, the heart, the lung, and the colon is feasible. Further studies have to show that MR-based screening programs are cost-effective in terms of the life-years saved.
Literatur
1.
Zurück zum Zitat Cordes L, Heine F, Krickau G (1972) Results of mass radiography for tuberculosis in older school children. Offentl Gesundheitswes 34:173–179PubMed Cordes L, Heine F, Krickau G (1972) Results of mass radiography for tuberculosis in older school children. Offentl Gesundheitswes 34:173–179PubMed
2.
Zurück zum Zitat Lunn JA, Mayho V (1989) Incidence of pulmonary tuberculosis by occupation of hospital employees in the National Health Service in England and Wales 1980–1984. J Soc Occup Med 39:30–32PubMed Lunn JA, Mayho V (1989) Incidence of pulmonary tuberculosis by occupation of hospital employees in the National Health Service in England and Wales 1980–1984. J Soc Occup Med 39:30–32PubMed
3.
Zurück zum Zitat Henschke CI, McCauley DI, Yankelevitz DF et al (1999) Early Lung Cancer Action Project: overall design and findings from baseline screening. Lancet 354:99–105PubMed Henschke CI, McCauley DI, Yankelevitz DF et al (1999) Early Lung Cancer Action Project: overall design and findings from baseline screening. Lancet 354:99–105PubMed
4.
Zurück zum Zitat Diederich S, Wormanns D, Semik M et al (2002) Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers. Radiology 222:773–778PubMed Diederich S, Wormanns D, Semik M et al (2002) Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers. Radiology 222:773–778PubMed
5.
Zurück zum Zitat Ellis JR, Gleeson FV (2002) New concepts in lung cancer screening. Curr Opin Pulm Med 8:270–274CrossRefPubMed Ellis JR, Gleeson FV (2002) New concepts in lung cancer screening. Curr Opin Pulm Med 8:270–274CrossRefPubMed
6.
Zurück zum Zitat Elsberry RB (2002) The invasion of the body scanners decisions in imaging economics 2002 Feb: 18–21, p 42 Elsberry RB (2002) The invasion of the body scanners decisions in imaging economics 2002 Feb: 18–21, p 42
9.
Zurück zum Zitat Lauenstein TC, Freudenberg LS, Goehde SC et al (2002) Whole-body MRI using a rolling table platform for the detection of bone metastases. Eur Radiol 12:2091–2099PubMed Lauenstein TC, Freudenberg LS, Goehde SC et al (2002) Whole-body MRI using a rolling table platform for the detection of bone metastases. Eur Radiol 12:2091–2099PubMed
10.
Zurück zum Zitat Gohde SC, Goyen M, Forsting M, Debatin JF (2002) Prevention without radiation—a strategy for comprehensive early detection using magnetic resonance tomography (Article in German). Radiologe 42:622–629 Gohde SC, Goyen M, Forsting M, Debatin JF (2002) Prevention without radiation—a strategy for comprehensive early detection using magnetic resonance tomography (Article in German). Radiologe 42:622–629
11.
Zurück zum Zitat Ruehm SG, Goyen M, Barkhausen J et al (2001) Rapid magnetic resonance angiography for detection of atherosclerosis. Lancet 357:1086–1091PubMed Ruehm SG, Goyen M, Barkhausen J et al (2001) Rapid magnetic resonance angiography for detection of atherosclerosis. Lancet 357:1086–1091PubMed
12.
Zurück zum Zitat Goyen M, Quick HH, Debatin JF et al (2002) Whole body 3D MR angiography using a rolling table platform: initial clinical experience. Radiology 224:270–277PubMed Goyen M, Quick HH, Debatin JF et al (2002) Whole body 3D MR angiography using a rolling table platform: initial clinical experience. Radiology 224:270–277PubMed
13.
Zurück zum Zitat Ruehm SG, Goyen M, Quick HH et al (2000) Whole-body MRA on a rolling table platform (AngioSURF). RöFo 172:670–674 Ruehm SG, Goyen M, Quick HH et al (2000) Whole-body MRA on a rolling table platform (AngioSURF). RöFo 172:670–674
14.
Zurück zum Zitat Goyen M, Herborn CU, Lauenstein TC, Debatin JF, Bosk S, Ruehm SG (2002) Optimization of contrast dosage for gadobenate dimeglumine-enhanced high-resolution whole body 3D MR Angiography. Invest Radiol 37:263–268CrossRefPubMed Goyen M, Herborn CU, Lauenstein TC, Debatin JF, Bosk S, Ruehm SG (2002) Optimization of contrast dosage for gadobenate dimeglumine-enhanced high-resolution whole body 3D MR Angiography. Invest Radiol 37:263–268CrossRefPubMed
15.
Zurück zum Zitat Lauenstein TC, Herborn CU, Vogt FM, Gohde SC, Debatin JF, Ruehm SG (2001) Dark lumen MR-colonography: initial experience. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:785–789 Lauenstein TC, Herborn CU, Vogt FM, Gohde SC, Debatin JF, Ruehm SG (2001) Dark lumen MR-colonography: initial experience. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:785–789
16.
Zurück zum Zitat Vogler H, Platzek J, Schuhmann-Giampieri G et al (1995) Pre-clinical evaluation of gadobutrol: a new, neutral, extracellular contrast agent for magnetic resonance imaging. Eur J Radiol 21:1–10PubMed Vogler H, Platzek J, Schuhmann-Giampieri G et al (1995) Pre-clinical evaluation of gadobutrol: a new, neutral, extracellular contrast agent for magnetic resonance imaging. Eur J Radiol 21:1–10PubMed
17.
Zurück zum Zitat Goyen M, Lauenstein TC, Herborn CU, Debatin JF, Bosk S, Ruehm SG (2001) 0.5 M Gd-Chelate (Magnevist) vs. 1.0 M Gd-Chelate (Gadovist): dose-independent effect on image quality of pelvic 3D MRA. J Magn Res Imaging 14:602–607CrossRef Goyen M, Lauenstein TC, Herborn CU, Debatin JF, Bosk S, Ruehm SG (2001) 0.5 M Gd-Chelate (Magnevist) vs. 1.0 M Gd-Chelate (Gadovist): dose-independent effect on image quality of pelvic 3D MRA. J Magn Res Imaging 14:602–607CrossRef
18.
Zurück zum Zitat Anderson KM, Wilson PWF, Odell PM, Kannel WB (1991) An updated coronary risk profile: a statement for health professionals. Circulation 83:356–362PubMed Anderson KM, Wilson PWF, Odell PM, Kannel WB (1991) An updated coronary risk profile: a statement for health professionals. Circulation 83:356–362PubMed
19.
Zurück zum Zitat Chambless L, Keil U, Dobson A et al (1997) Population versus clinical view of case fatality from acute coronary heart disease—results from the WHO Monica project 1985–1990. Circulation 96:3849–3859PubMed Chambless L, Keil U, Dobson A et al (1997) Population versus clinical view of case fatality from acute coronary heart disease—results from the WHO Monica project 1985–1990. Circulation 96:3849–3859PubMed
20.
Zurück zum Zitat Fuster V, Pearson TA (1996) 27th Bethesda Conference. Matching the intensity of risk factor management with the hazard for coronary heart disease events. J Am Coll Cardiol 27:957–1047PubMed Fuster V, Pearson TA (1996) 27th Bethesda Conference. Matching the intensity of risk factor management with the hazard for coronary heart disease events. J Am Coll Cardiol 27:957–1047PubMed
21.
Zurück zum Zitat Anderson KM, Wilson PWF, Odell PM, Kannel WB (1991) An updated coronary risk profile: a statement for health professionals. Circulation 83:356–362PubMed Anderson KM, Wilson PWF, Odell PM, Kannel WB (1991) An updated coronary risk profile: a statement for health professionals. Circulation 83:356–362PubMed
22.
Zurück zum Zitat Pyorala K, De Backer G, Graham I, Poole-Wilson P, Wood D (1994) On behalf of the task force: prevention of coronary artery disease in clinical practice. Recommandations of the task force of the European Society of Cardiology, European Atherosclerosis Society and European Society of Hypertension. Eur Heart J 15:1300–1331PubMed Pyorala K, De Backer G, Graham I, Poole-Wilson P, Wood D (1994) On behalf of the task force: prevention of coronary artery disease in clinical practice. Recommandations of the task force of the European Society of Cardiology, European Atherosclerosis Society and European Society of Hypertension. Eur Heart J 15:1300–1331PubMed
23.
Zurück zum Zitat Kim DE, Bae HJ, Lee SH, Kim H, Yoon BW, Roh JK (2002) Gradient echo magnetic resonance imaging in the prediction of hemorrhagic vs ischemic stroke: a need for the consideration of the extent of leukoariosis. Arch Neurol 59:425–429CrossRefPubMed Kim DE, Bae HJ, Lee SH, Kim H, Yoon BW, Roh JK (2002) Gradient echo magnetic resonance imaging in the prediction of hemorrhagic vs ischemic stroke: a need for the consideration of the extent of leukoariosis. Arch Neurol 59:425–429CrossRefPubMed
24.
Zurück zum Zitat Gerber BL, Lima JA, Garot J, Bluemke DA (2000) Magnetic resonance imaging of myocardial infarct. Top Magn Reson Imaging 11:372–382CrossRefPubMed Gerber BL, Lima JA, Garot J, Bluemke DA (2000) Magnetic resonance imaging of myocardial infarct. Top Magn Reson Imaging 11:372–382CrossRefPubMed
25.
Zurück zum Zitat Barkhausen J, Ebert W, Debatin JF, Weinmann HJ (2002) Imaging of myocardial infarction: comparison of magnevist and gadophrin-3 in rabbits. J Am Coll Cardiol 39(8):1392–1398CrossRefPubMed Barkhausen J, Ebert W, Debatin JF, Weinmann HJ (2002) Imaging of myocardial infarction: comparison of magnevist and gadophrin-3 in rabbits. J Am Coll Cardiol 39(8):1392–1398CrossRefPubMed
26.
Zurück zum Zitat Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF (2001) MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology 219:264–269PubMed Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF (2001) MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology 219:264–269PubMed
27.
Zurück zum Zitat Goyen M, Herborn CU, Kroger K et al (2003) Detection of atherosclerosis: systemic imaging for systemic disease with whole body three-dimensional MR-angiography—initial experience. Radiology 227:277–282PubMed Goyen M, Herborn CU, Kroger K et al (2003) Detection of atherosclerosis: systemic imaging for systemic disease with whole body three-dimensional MR-angiography—initial experience. Radiology 227:277–282PubMed
28.
Zurück zum Zitat Goyen M, Laub G, Ladd ME, Debatin JF, Barkhausen J, Truemmler KH, Bosk S, Ruehm SG (2001) Dynamic 3D MR angiography of the pulmonary arteries in under 4 seconds. J Magn Res Imaging 13:372–377CrossRef Goyen M, Laub G, Ladd ME, Debatin JF, Barkhausen J, Truemmler KH, Bosk S, Ruehm SG (2001) Dynamic 3D MR angiography of the pulmonary arteries in under 4 seconds. J Magn Res Imaging 13:372–377CrossRef
29.
Zurück zum Zitat Kersjes W, Mayer E, Buchenroth M, Schunk K, Fouda N, Cagil H (1997) Diagnosis of pulmonary metastases with turbo-SE MR imaging. Eur Radiol 7:1190–1194CrossRefPubMed Kersjes W, Mayer E, Buchenroth M, Schunk K, Fouda N, Cagil H (1997) Diagnosis of pulmonary metastases with turbo-SE MR imaging. Eur Radiol 7:1190–1194CrossRefPubMed
30.
Zurück zum Zitat Lutterbey G, Leutner C, Gieseke J et al (1998) Detection of focal lung lesions with magnetic resonance tomography using T2-weighted ultrashort turbo-spin-echo-sequence in comparison with spiral computerized tomography. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 169:365–369PubMed Lutterbey G, Leutner C, Gieseke J et al (1998) Detection of focal lung lesions with magnetic resonance tomography using T2-weighted ultrashort turbo-spin-echo-sequence in comparison with spiral computerized tomography. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 169:365–369PubMed
31.
Zurück zum Zitat Schroeder T, Ruehm SG, Ladd ME et al (2002) Detection of pulmonary lesions: MRT Haste vs MultiSlice CT. Proc Intl Soc Mag Reson Med 10:39 Schroeder T, Ruehm SG, Ladd ME et al (2002) Detection of pulmonary lesions: MRT Haste vs MultiSlice CT. Proc Intl Soc Mag Reson Med 10:39
32.
Zurück zum Zitat Landis SH, Murray T, Bodden S, Wingo PA (1998) Cancer statistics. CA Cancer J Clin 48:6–29PubMed Landis SH, Murray T, Bodden S, Wingo PA (1998) Cancer statistics. CA Cancer J Clin 48:6–29PubMed
33.
Zurück zum Zitat Papanikolaou N, Grammatikakis J, Maris T, Lauenstein T, Prassopoulos, Goutsoyiannis N (2003) MR colonography with fecal tagging: comparison between 2D turbo FLASH and 3D FLASH sequences. Eur Radiol 13:448–452PubMed Papanikolaou N, Grammatikakis J, Maris T, Lauenstein T, Prassopoulos, Goutsoyiannis N (2003) MR colonography with fecal tagging: comparison between 2D turbo FLASH and 3D FLASH sequences. Eur Radiol 13:448–452PubMed
34.
Zurück zum Zitat Hawighorst H, Schoenberg SO, Knopp MV, Essig M, Miltner P, van Kaick G (1999) Hepatic lesions: morphologic and functional characterization with multiphase breath-hold 3D gadolinium-enhanced MR angiography—initial results. Radiology 210:89–96PubMed Hawighorst H, Schoenberg SO, Knopp MV, Essig M, Miltner P, van Kaick G (1999) Hepatic lesions: morphologic and functional characterization with multiphase breath-hold 3D gadolinium-enhanced MR angiography—initial results. Radiology 210:89–96PubMed
35.
Zurück zum Zitat Luboldt W, Bauerfeind P, Steiner P, Fried M, Krestin GP, Debatin J (1997) Preliminary assessment of three-dimensional magnetic resonance imaging for various colonic disorders. Lancet 349(9061):1288–1291PubMed Luboldt W, Bauerfeind P, Steiner P, Fried M, Krestin GP, Debatin J (1997) Preliminary assessment of three-dimensional magnetic resonance imaging for various colonic disorders. Lancet 349(9061):1288–1291PubMed
36.
Zurück zum Zitat Schoepf UJ, Becker CR, Obuchowski NA et al (2001) Multi-slice computed tomography as a screening tool for colon cancer, lung cancer and coronary artery disease. Eur Radiol 11:1975–1985CrossRefPubMed Schoepf UJ, Becker CR, Obuchowski NA et al (2001) Multi-slice computed tomography as a screening tool for colon cancer, lung cancer and coronary artery disease. Eur Radiol 11:1975–1985CrossRefPubMed
37.
Zurück zum Zitat Goldin JG, Yoon HC, Greaser LE III et al (2000) Spiral versus electron-beam CT for coronary artery calcium scoring. Radiology 221:213–221 Goldin JG, Yoon HC, Greaser LE III et al (2000) Spiral versus electron-beam CT for coronary artery calcium scoring. Radiology 221:213–221
38.
Zurück zum Zitat Laghi A, Iannaccone R, Carbone I et al (2002) Detection of colorectal lesions with virtual computed tomographic colonography. Am J Surg 183:124–131PubMed Laghi A, Iannaccone R, Carbone I et al (2002) Detection of colorectal lesions with virtual computed tomographic colonography. Am J Surg 183:124–131PubMed
39.
Zurück zum Zitat Ahmed S, Shellock FG (2001) Magnetic resonance imaging safety: implications for cardiovascular patients. J Cardiovasc Magn Reson 3:171–182CrossRefPubMed Ahmed S, Shellock FG (2001) Magnetic resonance imaging safety: implications for cardiovascular patients. J Cardiovasc Magn Reson 3:171–182CrossRefPubMed
40.
Zurück zum Zitat Tombach B, Bremer C, Reimer P et al (2001) Renal tolerance of a neutral gadolinium chelate (gadobutrol) in patients with chronic renal failure: results of a randomized study. Radiology 218:651–657PubMed Tombach B, Bremer C, Reimer P et al (2001) Renal tolerance of a neutral gadolinium chelate (gadobutrol) in patients with chronic renal failure: results of a randomized study. Radiology 218:651–657PubMed
Metadaten
Titel
MR-based full-body preventative cardiovascular and tumor imaging: technique and preliminary experience
verfasst von
Mathias Goyen
Susanne C. Goehde
Christoph U. Herborn
Peter Hunold
Florian M. Vogt
Elke R. Gizewski
Thomas C. Lauenstein
Waleed Ajaj
Michael Forsting
Jörg F. Debatin
Stefan G. Ruehm
Publikationsdatum
01.05.2004
Erschienen in
European Radiology / Ausgabe 5/2004
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2249-9

Weitere Artikel der Ausgabe 5/2004

European Radiology 5/2004 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.