Skip to main content
Erschienen in: European Radiology 8/2004

01.08.2004 | Cardiac

Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography

verfasst von: Riccardo Marano, Maria Luigia Storto, Nicola Maddestra, Lorenzo Bonomo

Erschienen in: European Radiology | Ausgabe 8/2004

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to assess the accuracy of four-row multi-detector CT (MDCT) in the evaluation of coronary artery bypass graft (CABG) in patients with at least a left internal mammary artery (LIMA) grafted to the left anterior descending artery (LAD), because of the conduit of choice in bypass surgery and the greater difficulty of evaluation with non-invasive diagnostic tools. Included in the study were 57 patients with a total of 122 grafts (95 arterial and 27 venous) who underwent MDCT (4×2.5-mm detector-collimation, 3-mm slice width, 1.5-mm reconstruction increment) with retrospective ECG gating. Twelve patients (21%) with high heart rates were given beta-blockers in order to obtain a heart rate ≤70 bpm in all patients. The ECG-synchronized axial images, reconstructed in the mid-diastole, MPR, MIP and 3D-VR images were independently and blindly assessed by two radiologists for graft patency and presence of high grade stenosis. Conventional angiography was the standard of reference. MDCT correctly classified 92/94 patent grafts and 26/28 occluded grafts (sensitivity/specificity 93%/97.8%); sensitivity and specificity of MDCT for assessment of arterial grafts were 100 and 98.7% (77/78 patent grafts and 17/17 occluded grafts). Image quality was considered adequate for assessment of significant stenoses in 62/92 (67%) patent grafts, with a significant differences between LIMA and non-LIMA conduits (44/57 vs. 18/65; P=0.002), according to the coronary vessel area supplied (anterior>lateral>posterior-inferior wall; P=0.002). In the remaining 30 patent grafts (33%), the assessment of stenoses was hampered by surgical clips, calcifications and motion artifacts. Sensitivity and specificity of MDCT for detection of significant graft stenoses were 80 and 96%, respectively. Inter-observer agreement was good (K=0.73). MDCT seems to be a valuable diagnostic tool for non-invasive assessment of patency of both venous and arterial grafts. An accurate evaluation of distal anastomoses and native coronary arteries may still represent a limitation of four-row MDCT, which will improve with the newest MDCT scanner.
Literatur
1.
Zurück zum Zitat Bourassa MG, Fisher LD, Campeau L, Gillespie MJ, McConney M, Lesperance J (1985) Long-term fate of bypass grafts: the coronary artery surgery study (CASS) and Montreal Heart Institute experiences. Circulation 72:V71–V78PubMed Bourassa MG, Fisher LD, Campeau L, Gillespie MJ, McConney M, Lesperance J (1985) Long-term fate of bypass grafts: the coronary artery surgery study (CASS) and Montreal Heart Institute experiences. Circulation 72:V71–V78PubMed
2.
Zurück zum Zitat Campeau L, Enjalbert M, Lesperance J, Vaislic C, Grondin CM, Bourassa MG (1983) Atherosclerosis and late closure of aortocoronary saphenous vein grafts: sequential angiographic studies at 2 weeks, 1 year, 5 to 7 years, and 10 to 12 years after surgery. Circulation 68:1–7 Campeau L, Enjalbert M, Lesperance J, Vaislic C, Grondin CM, Bourassa MG (1983) Atherosclerosis and late closure of aortocoronary saphenous vein grafts: sequential angiographic studies at 2 weeks, 1 year, 5 to 7 years, and 10 to 12 years after surgery. Circulation 68:1–7
3.
Zurück zum Zitat Motwani JG, Topol EJ (1998) Aortocoronary saphenous vein graft disease: pathogenesis, predisposition, and prevention. Circulation 97:916–931PubMed Motwani JG, Topol EJ (1998) Aortocoronary saphenous vein graft disease: pathogenesis, predisposition, and prevention. Circulation 97:916–931PubMed
4.
Zurück zum Zitat Cameron A, Davis KB, Green G, Schaff HV (1996) Coronary bypass surgery with internal thoracic artery grafts: effects on survival over a 15-year period. N Engl J Med 334:216–219CrossRefPubMed Cameron A, Davis KB, Green G, Schaff HV (1996) Coronary bypass surgery with internal thoracic artery grafts: effects on survival over a 15-year period. N Engl J Med 334:216–219CrossRefPubMed
5.
Zurück zum Zitat Johnson LW, Krone R (1993) Cardiac catheterization 1991: a report of the Registry of the Society for Cardiac Angiography and Interventions (SCA&I). Cathet Cardiovasc Diagn 28:219–220PubMed Johnson LW, Krone R (1993) Cardiac catheterization 1991: a report of the Registry of the Society for Cardiac Angiography and Interventions (SCA&I). Cathet Cardiovasc Diagn 28:219–220PubMed
6.
Zurück zum Zitat Stanford W, Brundage BH, Macmillan R, Chomka EV, Bateman TM, Eldredge WJ, Lipton MJ, White CW, Wilson RF (1988) Sensitivity and specificity of assessing coronary artery bypass graft patency with ultrafast computed tomography: result of a multicenter study. J Am Coll Cardiol 12:1–7PubMed Stanford W, Brundage BH, Macmillan R, Chomka EV, Bateman TM, Eldredge WJ, Lipton MJ, White CW, Wilson RF (1988) Sensitivity and specificity of assessing coronary artery bypass graft patency with ultrafast computed tomography: result of a multicenter study. J Am Coll Cardiol 12:1–7PubMed
7.
Zurück zum Zitat Ha JW, Cho SY, Shim WH, Chung N, Yang Y, Lee HM (1999) Non invasive evaluation of coronary artery bypass graft patency using three dimensional angiography obtained with contrast enhanced electron beam CT. Am J Roentgenol 172:1055–1059 Ha JW, Cho SY, Shim WH, Chung N, Yang Y, Lee HM (1999) Non invasive evaluation of coronary artery bypass graft patency using three dimensional angiography obtained with contrast enhanced electron beam CT. Am J Roentgenol 172:1055–1059
8.
Zurück zum Zitat Enzweiler CNH, Kivelitz DE, Wiese TH, Taupitz M, Hohn S, Borges AC (2000) Coronary artery bypass grafts: improved electron beam tomography by prolonging breath holds with preoxygenation. Radiology 217:278–283PubMed Enzweiler CNH, Kivelitz DE, Wiese TH, Taupitz M, Hohn S, Borges AC (2000) Coronary artery bypass grafts: improved electron beam tomography by prolonging breath holds with preoxygenation. Radiology 217:278–283PubMed
9.
Zurück zum Zitat White RD, Caputo GR, Mark AS, Modin GW, Higgins CB (1987) Coronary artery bypass graft patency: non invasive evaluation with MR imaging. Radiology 164:681–686PubMed White RD, Caputo GR, Mark AS, Modin GW, Higgins CB (1987) Coronary artery bypass graft patency: non invasive evaluation with MR imaging. Radiology 164:681–686PubMed
10.
Zurück zum Zitat Rubistein RI, Askenase AD, Thickman D, Feldman MS, Agarwal JB, Helfant RH (1987) Magnetic resonance imaging to evaluate patency of aortocoronary bypass grafts. Circulation 76:786–791PubMed Rubistein RI, Askenase AD, Thickman D, Feldman MS, Agarwal JB, Helfant RH (1987) Magnetic resonance imaging to evaluate patency of aortocoronary bypass grafts. Circulation 76:786–791PubMed
11.
Zurück zum Zitat White RD, Pflugfelder PW, Lipton MJ, Higgins CB (1988) Coronary artery bypass grafts: evaluation of patency with cine MR imaging. Am J Roentgenol 150:1271–1274 White RD, Pflugfelder PW, Lipton MJ, Higgins CB (1988) Coronary artery bypass grafts: evaluation of patency with cine MR imaging. Am J Roentgenol 150:1271–1274
12.
Zurück zum Zitat Vrachliotis TG, Bis KG, Aliabadi D, Shetty AN, Safian R, Simonetti O (1997) Contrast enhanced MR angiography for evaluating patency of coronary artery by-pass grafts. Am J Roentgenol 168:1073–1080 Vrachliotis TG, Bis KG, Aliabadi D, Shetty AN, Safian R, Simonetti O (1997) Contrast enhanced MR angiography for evaluating patency of coronary artery by-pass grafts. Am J Roentgenol 168:1073–1080
13.
Zurück zum Zitat Wintersperger BJ, Engelmann MG, von Smekal A, Knez A, Penzkofer HV, Hofling B (1998) Patency of coronary by-pass grafts: assessment with breath-hold contrast enhanced MR angiography-value of a non electrocardiographically triggered technique. Radiology 208:345–351PubMed Wintersperger BJ, Engelmann MG, von Smekal A, Knez A, Penzkofer HV, Hofling B (1998) Patency of coronary by-pass grafts: assessment with breath-hold contrast enhanced MR angiography-value of a non electrocardiographically triggered technique. Radiology 208:345–351PubMed
14.
Zurück zum Zitat Langerak SE, Vliegen HW, de Roos A, Zwinderman AH, Jukema JW, Knuz P (2002) Detection of vein graft disease using high-resolution magnetic resonance angiography. Circulation 105:328–333CrossRefPubMed Langerak SE, Vliegen HW, de Roos A, Zwinderman AH, Jukema JW, Knuz P (2002) Detection of vein graft disease using high-resolution magnetic resonance angiography. Circulation 105:328–333CrossRefPubMed
15.
Zurück zum Zitat Langerak SE, Vliegen HW, Jukema JW, Knuz P, Zwinderman AH, Lamb HJ (2003) Value of magnetic resonance imaging for the non invasive detection of stenosis in coronary artery bypass grafts and recipients coronary arteries. Circulation 107:1502–1508CrossRefPubMed Langerak SE, Vliegen HW, Jukema JW, Knuz P, Zwinderman AH, Lamb HJ (2003) Value of magnetic resonance imaging for the non invasive detection of stenosis in coronary artery bypass grafts and recipients coronary arteries. Circulation 107:1502–1508CrossRefPubMed
16.
Zurück zum Zitat Achenbach S, Ulzheimer S, Baum U, Kachelriess M, Ropers D, Giesler T (2000) Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT. Circulation 102:2823–2828PubMed Achenbach S, Ulzheimer S, Baum U, Kachelriess M, Ropers D, Giesler T (2000) Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT. Circulation 102:2823–2828PubMed
17.
Zurück zum Zitat Nieman K, Oudkerk M, Rensing BJ, van Ooijen P, Munne A, van Geuns RJ (2001) Coronary angiography with multi-slice computed tomography. Lancet 357:599–603PubMed Nieman K, Oudkerk M, Rensing BJ, van Ooijen P, Munne A, van Geuns RJ (2001) Coronary angiography with multi-slice computed tomography. Lancet 357:599–603PubMed
18.
Zurück zum Zitat Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054 Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054
19.
Zurück zum Zitat Ohnesorge B, Flohr T, Fischbach R, Kopp AF, Knez A, Schroder S, Schopf UJ, Crispin A, Klotz E, Reiser MF, Becker CR (2002) Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT. Eur Radiol 12:1532–1540CrossRefPubMed Ohnesorge B, Flohr T, Fischbach R, Kopp AF, Knez A, Schroder S, Schopf UJ, Crispin A, Klotz E, Reiser MF, Becker CR (2002) Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT. Eur Radiol 12:1532–1540CrossRefPubMed
20.
Zurück zum Zitat Rodenwaldt J (2003) Multislice computed tomography of the coronary arteries. Eur Radiol 13:748–757PubMed Rodenwaldt J (2003) Multislice computed tomography of the coronary arteries. Eur Radiol 13:748–757PubMed
21.
Zurück zum Zitat Jung B, Mahnken AH, Stargardt A, Simon J, Flohr T, Schaller S, Koos R, Gunther RW, Wildberger JE (2003) Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart. Eur Radiol 13:2560–2566CrossRefPubMed Jung B, Mahnken AH, Stargardt A, Simon J, Flohr T, Schaller S, Koos R, Gunther RW, Wildberger JE (2003) Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart. Eur Radiol 13:2560–2566CrossRefPubMed
22.
Zurück zum Zitat Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666 Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666
23.
Zurück zum Zitat Flohr T, Ohnesorge B (2001) Heart rate adaptative optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed Flohr T, Ohnesorge B (2001) Heart rate adaptative optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed
24.
Zurück zum Zitat Hong C, Becker CR, Huber A, Schoepf UJ, Ohnesorge B, Knez A (2001) ECG gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 220:712–717PubMed Hong C, Becker CR, Huber A, Schoepf UJ, Ohnesorge B, Knez A (2001) ECG gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 220:712–717PubMed
25.
Zurück zum Zitat Kopp AF, Schroeder S, Kuettner A, Heuschmid M, Georg C, Ohnesorge B (2001) Coronary arteries: retrospectively ECG-gated multidetector row CT angiography with selective optimization of the image reconstruction window. Radiology 221:683–688PubMed Kopp AF, Schroeder S, Kuettner A, Heuschmid M, Georg C, Ohnesorge B (2001) Coronary arteries: retrospectively ECG-gated multidetector row CT angiography with selective optimization of the image reconstruction window. Radiology 221:683–688PubMed
26.
Zurück zum Zitat Ropers D, Ulzheimer S, Wenkel E, Baum U, Giesler T, Derlien H (2001) Investigation of aortocoronary artery bypass grafts by multislice spiral computed tomography with electrocardiographic-gated image reconstruction. Am J Cardiol 88:792–795CrossRefPubMed Ropers D, Ulzheimer S, Wenkel E, Baum U, Giesler T, Derlien H (2001) Investigation of aortocoronary artery bypass grafts by multislice spiral computed tomography with electrocardiographic-gated image reconstruction. Am J Cardiol 88:792–795CrossRefPubMed
27.
Zurück zum Zitat Haage P, Schimtz-Rode T, Hubner D, Piroth W, Ghunter RW (2000) Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax. Am J Roentgenol 174:1049–1053 Haage P, Schimtz-Rode T, Hubner D, Piroth W, Ghunter RW (2000) Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax. Am J Roentgenol 174:1049–1053
28.
Zurück zum Zitat Cademartiri F, van der Lugt A, Luccichenti G, Pavone P, Krestin G (2002) Parametring affecting bolus geometry in CTA. A review. J Comput Assist Tomogr 26:598–607CrossRefPubMed Cademartiri F, van der Lugt A, Luccichenti G, Pavone P, Krestin G (2002) Parametring affecting bolus geometry in CTA. A review. J Comput Assist Tomogr 26:598–607CrossRefPubMed
29.
Zurück zum Zitat Jara FM, Kalush J, Kahn ML (2002) Electron beam coronary angiography to assess patency in the off-pump coronary bypass graft. Ann Thorac Surg 74:S1395–S1397CrossRefPubMed Jara FM, Kalush J, Kahn ML (2002) Electron beam coronary angiography to assess patency in the off-pump coronary bypass graft. Ann Thorac Surg 74:S1395–S1397CrossRefPubMed
Metadaten
Titel
Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography
verfasst von
Riccardo Marano
Maria Luigia Storto
Nicola Maddestra
Lorenzo Bonomo
Publikationsdatum
01.08.2004
Erschienen in
European Radiology / Ausgabe 8/2004
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2323-3

Weitere Artikel der Ausgabe 8/2004

European Radiology 8/2004 Zur Ausgabe

Book Reviews

Recent literature

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.