Skip to main content
Erschienen in: European Radiology 4/2005

01.04.2005 | Cardiac

Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter

verfasst von: Harald Seifarth, Rainer Raupach, Stefan Schaller, Eva Maria Fallenberg, Thomas Flohr, Walter Heindel, Roman Fischbach, David Maintz

Erschienen in: European Radiology | Ausgabe 4/2005

Einloggen, um Zugang zu erhalten

Abstract

To compare the effect of different reconstruction kernels and a noise-reducing postprocessing filter on the delineation of coronary artery stents in 16-slice CT-angiography. Ten patients with coronary stents (seven LAD, five RCX and three RCA) were examined with a 16-slice MDCT using standard acquisition parameters. Images were reconstructed using a medium soft (B30f) and a dedicated, edge-enhancing kernel (B46f). Additional postprocessing with an edge-preserving filter was performed on B46f images to reduce the image noise. In multiplanar reformations (MPRs) along and perpendicular to the stent axis, intraluminal attenuation values and the visible lumen diameter were measured. Image noise was measured in the subcutaneous fat using a region of interest (ROI) technique. Arterial enhancement in the aorta was 275.1 HU. Attenuation in the stent lumen was 390.4, 340.0 and 346.8 HU in MPRs derived from B30f, original B46 and postprocessed B46f images. The mean noise level was 20.4, 35.0 and 24.9 HU respectively. The visible lumen diameter was significantly greater in B46f and postprocessed B46f images (2.17 and 2.16 mm), compared to 1.93 mm in B30f images (p<0.01). Edge-enhancing reconstruction kernels increase the visible stent lumen, but also increase image noise. Dedicated postprocessing filters can reduce the introduced noise without a loss of spatial resolution.
Literatur
1.
Zurück zum Zitat Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B, Schlundt C, Bautz W, Daniel WG, Achenbach S (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666 Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B, Schlundt C, Bautz W, Daniel WG, Achenbach S (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666
2.
Zurück zum Zitat Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054 Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054
3.
Zurück zum Zitat American Heart Association (2003) Heart and stroke statistical update, 2004. American Heart Association, Dallas American Heart Association (2003) Heart and stroke statistical update, 2004. American Heart Association, Dallas
4.
Zurück zum Zitat Mohlenkamp S, Pump H, Baumgart D, Haude M, Gronemeyer DH, Seibel RM, Schwartz RS, Erbel R (1999) Minimally invasive evaluation of coronary stents with electron beam computed tomography: in vivo and in vitro experience. Catheter Cardiovasc Interv 48:39–47 Mohlenkamp S, Pump H, Baumgart D, Haude M, Gronemeyer DH, Seibel RM, Schwartz RS, Erbel R (1999) Minimally invasive evaluation of coronary stents with electron beam computed tomography: in vivo and in vitro experience. Catheter Cardiovasc Interv 48:39–47
5.
Zurück zum Zitat Maintz D, Juergens KU, Wichter T, Grude M, Heindel W, Fischbach R (2003) Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation. Eur Radiol 13:830–835PubMed Maintz D, Juergens KU, Wichter T, Grude M, Heindel W, Fischbach R (2003) Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation. Eur Radiol 13:830–835PubMed
6.
Zurück zum Zitat Pump H, Mohlenkamp S, Sehnert CA, Schimpf SS, Schmidt A, Erbel R, Gronemeyer DH, Seibel RM (2000) Coronary arterial stent patency: assessment with electron-beam CT. Radiology 214:447–452 Pump H, Mohlenkamp S, Sehnert CA, Schimpf SS, Schmidt A, Erbel R, Gronemeyer DH, Seibel RM (2000) Coronary arterial stent patency: assessment with electron-beam CT. Radiology 214:447–452
7.
Zurück zum Zitat Kruger S, Mahnken AH, Sinha AM, Borghans A, Dedden K, Hoffmann R, Hanrath P (2003) Multislice spiral computed tomography for the detection of coronary stent restenosis and patency. International J Cardiol 89:167–172 Kruger S, Mahnken AH, Sinha AM, Borghans A, Dedden K, Hoffmann R, Hanrath P (2003) Multislice spiral computed tomography for the detection of coronary stent restenosis and patency. International J Cardiol 89:167–172
8.
Zurück zum Zitat Knollmann FD, Moller J, Gebert A, Bethge C, Felix R (2004) Assessment of coronary artery stent patency by electron-beam CT. Eur Radiol 14:1341–1347CrossRefPubMed Knollmann FD, Moller J, Gebert A, Bethge C, Felix R (2004) Assessment of coronary artery stent patency by electron-beam CT. Eur Radiol 14:1341–1347CrossRefPubMed
9.
Zurück zum Zitat Mahnken AH, Buecker A, Wildberger JE, Ruebben A, Stanzel S, Vogt F, Gunther RW, Blindt R (2004) Coronary artery stents in multislice computed tomography: in vitro artifact evaluation. Invest Radiol 39:27–33 Mahnken AH, Buecker A, Wildberger JE, Ruebben A, Stanzel S, Vogt F, Gunther RW, Blindt R (2004) Coronary artery stents in multislice computed tomography: in vitro artifact evaluation. Invest Radiol 39:27–33
10.
Zurück zum Zitat Maintz D, Seifarth H, Flohr T, Kramer S, Wichter T, Heindel W, Fischbach R (2003) Improved coronary artery stent visualization and in-stent stenosis detection using 16-slice computed-tomography and dedicated image reconstruction technique. Invest Radiol 38:790–795 Maintz D, Seifarth H, Flohr T, Kramer S, Wichter T, Heindel W, Fischbach R (2003) Improved coronary artery stent visualization and in-stent stenosis detection using 16-slice computed-tomography and dedicated image reconstruction technique. Invest Radiol 38:790–795
11.
Zurück zum Zitat Morin RL, Gerber TC, McCollough CH (2003) Radiation dose in computed tomography of the heart. Circulation 107:917–922 Morin RL, Gerber TC, McCollough CH (2003) Radiation dose in computed tomography of the heart. Circulation 107:917–922
12.
Zurück zum Zitat Rajagopal V, Rockson SG (2003) Coronary restenosis: a review of mechanisms and management. Am J Med 115:547–553 Rajagopal V, Rockson SG (2003) Coronary restenosis: a review of mechanisms and management. Am J Med 115:547–553
13.
Zurück zum Zitat Maintz D, Botnar RM, Fischbach R, Heindel W, Manning WJ, Stuber M (2002) Coronary magnetic resonance angiography for assessment of the stent lumen: a phantom study. J Cardiovasc Magn Reson 4:359–367 Maintz D, Botnar RM, Fischbach R, Heindel W, Manning WJ, Stuber M (2002) Coronary magnetic resonance angiography for assessment of the stent lumen: a phantom study. J Cardiovasc Magn Reson 4:359–367
14.
Zurück zum Zitat Maintz D, Fischbach R, Juergens K, Allkemper T, Wessling J, Heindel W (2001) Multislice CT-angiography of the iliac arteries in the presence of various stents: in vitro evaluation of artifacts and lumen visibility. Invest Radiol 36:699–704 Maintz D, Fischbach R, Juergens K, Allkemper T, Wessling J, Heindel W (2001) Multislice CT-angiography of the iliac arteries in the presence of various stents: in vitro evaluation of artifacts and lumen visibility. Invest Radiol 36:699–704
15.
Zurück zum Zitat Cademartiri F, Mollet N, Nieman K, Krestin GP, de Feyter PJ (2003) Images in cardiovascular medicine. Neointimal hyperplasia in carotid stent detected with multislice computed tomography. Circulation 108:e147 Cademartiri F, Mollet N, Nieman K, Krestin GP, de Feyter PJ (2003) Images in cardiovascular medicine. Neointimal hyperplasia in carotid stent detected with multislice computed tomography. Circulation 108:e147
16.
Zurück zum Zitat Hahnel S, Trossbach M, Braun C, Heiland S, Knauth M, Sartor K, Hartmann M (2003) Small-vessel stents for intracranial angioplasty: in vitro comparison of different stent designs and sizes by using CT angiography. Am J Neuroradiol 24:1512–1516 Hahnel S, Trossbach M, Braun C, Heiland S, Knauth M, Sartor K, Hartmann M (2003) Small-vessel stents for intracranial angioplasty: in vitro comparison of different stent designs and sizes by using CT angiography. Am J Neuroradiol 24:1512–1516
17.
Zurück zum Zitat Storto ML, Marano R, Maddestra N, Caputo M, Zimarino M, Bonomo L (2002) Images in cardiovascular medicine. Multislice spiral computed tomography for in-stent restenosis. Circulation 105:2005 Storto ML, Marano R, Maddestra N, Caputo M, Zimarino M, Bonomo L (2002) Images in cardiovascular medicine. Multislice spiral computed tomography for in-stent restenosis. Circulation 105:2005
18.
Zurück zum Zitat Kalra MK, Maher MM, Sahani DV, Blake MA, Hahn PF, Avinash GB, Toth TL, Halpern E, Saini S (2003) Low-dose CT of the abdomen: evaluation of image improvement with use of noise reduction filters pilot study. Radiology 228:251–256 Kalra MK, Maher MM, Sahani DV, Blake MA, Hahn PF, Avinash GB, Toth TL, Halpern E, Saini S (2003) Low-dose CT of the abdomen: evaluation of image improvement with use of noise reduction filters pilot study. Radiology 228:251–256
Metadaten
Titel
Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter
verfasst von
Harald Seifarth
Rainer Raupach
Stefan Schaller
Eva Maria Fallenberg
Thomas Flohr
Walter Heindel
Roman Fischbach
David Maintz
Publikationsdatum
01.04.2005
Erschienen in
European Radiology / Ausgabe 4/2005
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2594-8

Weitere Artikel der Ausgabe 4/2005

European Radiology 4/2005 Zur Ausgabe

News from the EFOMP

EFOMP News

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.