Effect of soft-copy display supported by CAD on mammography screening performance

verfasst von: Antonius A. J. Roelofs, Sander van Woudenberg, Johannes D. M. Otten, Jan H. C. L. Hendriks, Anke Bödicker, Carl J. G. Evertsz, Nico Karssemeijer

Erschienen in: European Radiology | Ausgabe 1/2006

Einloggen, um Zugang zu erhalten

Abstract

Diagnostic performance and reading speed for conventional mammography film reading is compared to reading digitized mammograms on a dedicated workstation. A series of mammograms judged negative at screening and corresponding priors were collected. Half were diagnosed as cancer at the next screening, or earlier for interval cancers. The others were normal. Original films were read by fifteen experienced screening radiologists. The readers annotated potential abnormalities and estimated their likelihood of malignancy. More than 1 year later, five radiologists reread a subset of 271 cases (88 cancer cases having visible signs in retrospect and 183 normals) on a mammography workstation after film digitization. Markers from a computer-aided detection (CAD) system for microcalcifications were available to the readers. Performance was evaluated by comparison of Az-scores based on ROC and multiple-Reader multiple-case (MRMC) analysis, and localized receiver operating characteristic (LROC) analysis for the 271 cases. Reading speed was also determined. No significant difference in diagnostic performance was observed between conventional and soft-copy reading. Average Az-scores were 0.83 and 0.84 respectively. Soft-copy reading was only slightly slower than conventional reading. Using a mammography workstation including CAD for detection of microcalcifications, soft-copy reading is possible without loss of quality or efficiency.
Literatur
1.
Zurück zum Zitat Pisano ED, Cole EB, Major S et al (2000) Radiologists’ preferences for digital mammographic display. Radiology 216:820–830PubMed Pisano ED, Cole EB, Major S et al (2000) Radiologists’ preferences for digital mammographic display. Radiology 216:820–830PubMed
2.
Zurück zum Zitat Pisano ED, Cole EB, Kistner EO et al (2002) Interpretation of digital mammograms: comparison of speed and accuracy of soft-copy versus printed-film display. Radiology 223:483–488PubMed Pisano ED, Cole EB, Kistner EO et al (2002) Interpretation of digital mammograms: comparison of speed and accuracy of soft-copy versus printed-film display. Radiology 223:483–488PubMed
3.
Zurück zum Zitat van Engeland S, Snoeren PR, Karssemeijer N, Hendriks JHCL (2003) Optimized perception of lesion growth in mammograms using digital display. In: Chakraborty DP, Krupinski EA (eds) Proceedings of SPIE, Medical Imaging 2003, Image perception, observer performance, and technology assessment, vol. 5034, SPIE, Bellingham, WA, pp 25–31 van Engeland S, Snoeren PR, Karssemeijer N, Hendriks JHCL (2003) Optimized perception of lesion growth in mammograms using digital display. In: Chakraborty DP, Krupinski EA (eds) Proceedings of SPIE, Medical Imaging 2003, Image perception, observer performance, and technology assessment, vol. 5034, SPIE, Bellingham, WA, pp 25–31
4.
Zurück zum Zitat van Engeland S, Snoeren PR, Hendriks JHCL, Karssemeijer N (2003) A comparison of methods for mammogram registration. In: Pluim JPW and Fitzpatrick JM (eds) Special issue on image registration. IEEE Trans Med Imag 22(11):1436–1444CrossRef van Engeland S, Snoeren PR, Hendriks JHCL, Karssemeijer N (2003) A comparison of methods for mammogram registration. In: Pluim JPW and Fitzpatrick JM (eds) Special issue on image registration. IEEE Trans Med Imag 22(11):1436–1444CrossRef
5.
Zurück zum Zitat Snoeren PR, Karssemeijer N (2003) Gray scale registration of mammograms using a model of image acquisition. In: Taylor C and Noble J (eds) Lect Notes Comp Sc 2732 pp 401–412 Snoeren PR, Karssemeijer N (2003) Gray scale registration of mammograms using a model of image acquisition. In: Taylor C and Noble J (eds) Lect Notes Comp Sc 2732 pp 401–412
6.
Zurück zum Zitat Laming D, Warren R (2000) Improving the detection of cancer in the screening of mammograms. J Med Screen 7:24–30CrossRefPubMed Laming D, Warren R (2000) Improving the detection of cancer in the screening of mammograms. J Med Screen 7:24–30CrossRefPubMed
7.
Zurück zum Zitat Evertsz CJG, Karssemeijer N, Bödicker A et al (2003) SCREEN-TRIAL: softcopy reading in European screening mammography. In: Peitgen H-O (ed) Digital mammography, IWDM 2002, 6th International workshop on digital mammography. Springer, Berlin Heidelberg New York, pp 423–427 Evertsz CJG, Karssemeijer N, Bödicker A et al (2003) SCREEN-TRIAL: softcopy reading in European screening mammography. In: Peitgen H-O (ed) Digital mammography, IWDM 2002, 6th International workshop on digital mammography. Springer, Berlin Heidelberg New York, pp 423–427
8.
Zurück zum Zitat Skaane P, Young K, Skjennald A (2003) Population-based mammography screening: comparison of screen-film and full-field digital mammography with soft-copy reading—Oslo I study. Radiology 229:877–884PubMed Skaane P, Young K, Skjennald A (2003) Population-based mammography screening: comparison of screen-film and full-field digital mammography with soft-copy reading—Oslo I study. Radiology 229:877–884PubMed
9.
Zurück zum Zitat Fracheboud J, Otto SJ, Groenewoud JH et al (2003) National Evaluation of Breast Cancer Screening in the Netherlands, 10th evaluation report, Rotterdam Fracheboud J, Otto SJ, Groenewoud JH et al (2003) National Evaluation of Breast Cancer Screening in the Netherlands, 10th evaluation report, Rotterdam
10.
Zurück zum Zitat Evertsz CJG, Bödicker A, Roelofs AAJ et al (2002) Softcopy reading in screening mammography: European projects SCREEN and SCREEN-TRIAL. Electromedica 70:157–164 Evertsz CJG, Bödicker A, Roelofs AAJ et al (2002) Softcopy reading in screening mammography: European projects SCREEN and SCREEN-TRIAL. Electromedica 70:157–164
11.
Zurück zum Zitat NEMA (1998) Digital imaging and communications in medicine (DICOM) supplement 28: grayscale standard display function. National Electrical Manufacturers Association, Rosslyn, VA, USA NEMA (1998) Digital imaging and communications in medicine (DICOM) supplement 28: grayscale standard display function. National Electrical Manufacturers Association, Rosslyn, VA, USA
12.
Zurück zum Zitat Roelofs AAJ, van Woudenberg S, Hendriks JHCL, Karssemeijer N (2003) Optimized soft-copy display of digitized mammograms. In: Chakraborty DP, Krupinski EA (eds) Proceedings of SPIE, Medical Imaging 2003, Image perception, observer performance, and technology assessment, vol. 5034. SPIE, Bellingham, WA, USA, pp 10–19 Roelofs AAJ, van Woudenberg S, Hendriks JHCL, Karssemeijer N (2003) Optimized soft-copy display of digitized mammograms. In: Chakraborty DP, Krupinski EA (eds) Proceedings of SPIE, Medical Imaging 2003, Image perception, observer performance, and technology assessment, vol. 5034. SPIE, Bellingham, WA, USA, pp 10–19
13.
Zurück zum Zitat Swensson RG (1996) Unified measurement of observer performance in detecting and localizing target objects on images. Med Phys 23:1709–1725CrossRefPubMed Swensson RG (1996) Unified measurement of observer performance in detecting and localizing target objects on images. Med Phys 23:1709–1725CrossRefPubMed
14.
Zurück zum Zitat Karssemeijer N, Otten JDM, Verbeek ALM et al (2003) Computer-aided detection versus independent double reading of masses on mammograms. Radiology 227:192–200PubMed Karssemeijer N, Otten JDM, Verbeek ALM et al (2003) Computer-aided detection versus independent double reading of masses on mammograms. Radiology 227:192–200PubMed
15.
Zurück zum Zitat Burhenne LJW, Wood SA, D’Orsi CJ et al (2000) Potential contribution of computer-aided detection to the sensitivity of screening mammography. Radiology 215:554–562PubMed Burhenne LJW, Wood SA, D’Orsi CJ et al (2000) Potential contribution of computer-aided detection to the sensitivity of screening mammography. Radiology 215:554–562PubMed
16.
Zurück zum Zitat Dorfman DD, Berbaum KS, Metz CE (1992) ROC rating analysis: generalization to the population of readers and cases with the jackknife method. Invest Radiol 27:723–731PubMed Dorfman DD, Berbaum KS, Metz CE (1992) ROC rating analysis: generalization to the population of readers and cases with the jackknife method. Invest Radiol 27:723–731PubMed
17.
Zurück zum Zitat Roe CA, Metz CE (1997) The Dorfman–Berbaum–Metz method for statistical analysis of multi-reader, multi-modality ROC data: validation by computer simulation. Acad Radiol 4:298–303PubMed Roe CA, Metz CE (1997) The Dorfman–Berbaum–Metz method for statistical analysis of multi-reader, multi-modality ROC data: validation by computer simulation. Acad Radiol 4:298–303PubMed
18.
Zurück zum Zitat Roe CA, Metz CE (1997) Variance-component modeling in the analysis of receiver operating characteristic index estimates. Acad Radiol 4:587–600PubMed Roe CA, Metz CE (1997) Variance-component modeling in the analysis of receiver operating characteristic index estimates. Acad Radiol 4:587–600PubMed
19.
Zurück zum Zitat Quenouille MH (1949) Approximate tests of correlation in time series. J Royal Stat Soc Ser B 11:68–84 Quenouille MH (1949) Approximate tests of correlation in time series. J Royal Stat Soc Ser B 11:68–84
20.
Zurück zum Zitat Tukey JW (1958) Bias and confidence in not quite large samples. Ann Math Stat 29:614. Abstract Tukey JW (1958) Bias and confidence in not quite large samples. Ann Math Stat 29:614. Abstract
22.
Zurück zum Zitat Karssemeijer N, Frieling JT, Hendriks JHCL (1993) Spatial resolution in digital mammography. Invest Radiol 28:413–419PubMed Karssemeijer N, Frieling JT, Hendriks JHCL (1993) Spatial resolution in digital mammography. Invest Radiol 28:413–419PubMed
23.
Zurück zum Zitat Freedman MT, Steller DE, Jafroudi H et al (1995) Digital mammography: tradeoffs between 50- and 100-micron pixel size. In: van Metter RL, Beutel J (eds) Proceedings of SPIE, Medical imaging 1995, Physics of medical imaging, vol. 2432. SPIE, San Diego, CA, pp 114–125 Freedman MT, Steller DE, Jafroudi H et al (1995) Digital mammography: tradeoffs between 50- and 100-micron pixel size. In: van Metter RL, Beutel J (eds) Proceedings of SPIE, Medical imaging 1995, Physics of medical imaging, vol. 2432. SPIE, San Diego, CA, pp 114–125
24.
Zurück zum Zitat Vedantham S, Karellas A, Suryanarayanan S et al (2000) Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype. Med Phys 27:558–567CrossRefPubMed Vedantham S, Karellas A, Suryanarayanan S et al (2000) Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype. Med Phys 27:558–567CrossRefPubMed
25.
Zurück zum Zitat Noel A, Thibault F (2004) Digital detectors for mammography: the technical challenges. Eur Radiol 14(11):1990–1998CrossRefPubMed Noel A, Thibault F (2004) Digital detectors for mammography: the technical challenges. Eur Radiol 14(11):1990–1998CrossRefPubMed
26.
Zurück zum Zitat Gennaro G, Baldelli P, Taibi A, Di Maggio C, Gambaccini M (2004) Patient dose in full-field digital mammography: an Italian survey. Eur Radiol 14(4):645–652CrossRefPubMed Gennaro G, Baldelli P, Taibi A, Di Maggio C, Gambaccini M (2004) Patient dose in full-field digital mammography: an Italian survey. Eur Radiol 14(4):645–652CrossRefPubMed
Metadaten
Titel
Effect of soft-copy display supported by CAD on mammography screening performance
verfasst von
Antonius A. J. Roelofs
Sander van Woudenberg
Johannes D. M. Otten
Jan H. C. L. Hendriks
Anke Bödicker
Carl J. G. Evertsz
Nico Karssemeijer
Publikationsdatum
01.01.2006
Erschienen in
European Radiology / Ausgabe 1/2006
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-2878-7

Weitere Artikel der Ausgabe 1/2006

European Radiology 1/2006 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.