Skip to main content
Erschienen in: European Radiology 2/2007

01.02.2007 | News from EUSOBI

Guidelines from the European Society of Breast Imaging for diagnostic interventional breast procedures

verfasst von: Matthew Wallis, Anne Tarvidon, Thomas Helbich, Ingrid Schreer

Erschienen in: European Radiology | Ausgabe 2/2007

Einloggen, um Zugang zu erhalten

Abstract

The aim of the breast team is to obtain a definitive, nonoperative diagnosis of all potential breast abnormalities in a timely and cost-effective way. Percutaneous needle biopsy with its high sensitivity and specificity should now be standard practice, removing the need for open surgical biopsy or frozen section. For patients with cancer, needle biopsy provides a cost-effective and rapid way of providing not only a definitive diagnosis but prognostic information, allowing prompt discussion of treatment options, be they surgical or medical. Early removal of uncertainty also allows better psychosocial adjustment to the disease. Patients with benign conditions found either by themselves or as a result of population or opportunistic screening can be promptly reassured and discharged, removing the health care and psychological costs of surgical biopsy or repeated follow-up. Radiologists involved in breast imaging should ensure that they have the necessary skills to carry out core biopsy and/or fine-needle aspiration (FNA) under all forms of image guidance. This paper provides guidelines on best practice for diagnostic interventional breast procedures and standards, against which all practitioners should audit themselves, from the European Society of Breast Imaging.
Literatur
1.
Zurück zum Zitat Lamb J, Anderson TJ, Dixon MJ, Levack P (1987) Role of fine needle aspiration cytology in breast cancer screening. J Clin Pathol 40:705–709PubMedCrossRef Lamb J, Anderson TJ, Dixon MJ, Levack P (1987) Role of fine needle aspiration cytology in breast cancer screening. J Clin Pathol 40:705–709PubMedCrossRef
2.
Zurück zum Zitat Cytology Sub-Group of the National Co-ordinating Committee for Breast Screening Pathology (1992) Guidelines for Cytology Procedures and Reporting in Breast Cancer Screening, Sheffield, NHS Breast Screening Programme (NHSBSP Publication No 22) Cytology Sub-Group of the National Co-ordinating Committee for Breast Screening Pathology (1992) Guidelines for Cytology Procedures and Reporting in Breast Cancer Screening, Sheffield, NHS Breast Screening Programme (NHSBSP Publication No 22)
3.
Zurück zum Zitat Britton P (1999) Fine needle aspiration or core biopsy. Breast 8:1–4CrossRef Britton P (1999) Fine needle aspiration or core biopsy. Breast 8:1–4CrossRef
4.
Zurück zum Zitat Zajdela A, Chossein NA, Pillerton JP (1975) The value of aspiration cytology in the diagnosis of breast cancer. Cancer 35:499–506PubMedCrossRef Zajdela A, Chossein NA, Pillerton JP (1975) The value of aspiration cytology in the diagnosis of breast cancer. Cancer 35:499–506PubMedCrossRef
5.
Zurück zum Zitat Azavedo E, Svane G, Auer G (1989) Stereotactic fine needle biopsy in 2594 mammographically detected non-palpable lesions. Lancet 1:1033–1035PubMedCrossRef Azavedo E, Svane G, Auer G (1989) Stereotactic fine needle biopsy in 2594 mammographically detected non-palpable lesions. Lancet 1:1033–1035PubMedCrossRef
6.
Zurück zum Zitat Helbich TH, Matzek W, Fuchsjäger MH (2004) Stereotactic and Ultrasound guided breast biopsy. Euro Radiol 14(3):383–393CrossRef Helbich TH, Matzek W, Fuchsjäger MH (2004) Stereotactic and Ultrasound guided breast biopsy. Euro Radiol 14(3):383–393CrossRef
7.
Zurück zum Zitat Liberman L (2000) Centennial dissertation. Percutaneous image-guided core breast biopsy: state of the art at the millennium. AJR Am J Roentgenol 174:1191–1199PubMed Liberman L (2000) Centennial dissertation. Percutaneous image-guided core breast biopsy: state of the art at the millennium. AJR Am J Roentgenol 174:1191–1199PubMed
8.
Zurück zum Zitat Britton P, McCann J (1999) Needle biopsy in the NHS Breast Screening Programme 1996/97: how much and how accurate? Breast 8:5–11CrossRef Britton P, McCann J (1999) Needle biopsy in the NHS Breast Screening Programme 1996/97: how much and how accurate? Breast 8:5–11CrossRef
9.
Zurück zum Zitat Berg WA, Hruban RH, Kumar D et al (1996) Lessons from mammographic-histopathologic correlation of large-core needle breast biopsy. Radiographics 16(5):1111–1130PubMed Berg WA, Hruban RH, Kumar D et al (1996) Lessons from mammographic-histopathologic correlation of large-core needle breast biopsy. Radiographics 16(5):1111–1130PubMed
10.
Zurück zum Zitat Dixon JM, Clarke PJ, Crucioli V, Lee EC, Greenhall MJ (1987) Reduction of the surgical excision rate in benign breast disease using fine needle aspiration cytology with immediate reporting. Br J Surg 75:1014–1016CrossRef Dixon JM, Clarke PJ, Crucioli V, Lee EC, Greenhall MJ (1987) Reduction of the surgical excision rate in benign breast disease using fine needle aspiration cytology with immediate reporting. Br J Surg 75:1014–1016CrossRef
11.
Zurück zum Zitat Hosie KB, Cope A, Li Ting Wai P, Nottingham J, Wallis MG, Bishop HM (1994) Specialist Breast Surgeons perform less benign Breast Operations. Breast 3:215–217CrossRef Hosie KB, Cope A, Li Ting Wai P, Nottingham J, Wallis MG, Bishop HM (1994) Specialist Breast Surgeons perform less benign Breast Operations. Breast 3:215–217CrossRef
12.
Zurück zum Zitat Lindfors KK, O’Connor J, Acredolo CR, Liston SE (1998) Short-interval follow-up mammography versus immediate core biopsy of benign breast lesions: assessment of patient stress. AJR Am J Roentgenol 171:55–58PubMed Lindfors KK, O’Connor J, Acredolo CR, Liston SE (1998) Short-interval follow-up mammography versus immediate core biopsy of benign breast lesions: assessment of patient stress. AJR Am J Roentgenol 171:55–58PubMed
13.
Zurück zum Zitat Currence BV, Pisano ED, Earp JA, Moore A, Chiu YF, Brown ME, Kurgat KL (2003) Does biopsy, aspiration or six month follow-up of a false-positive mammogram reduce future screening or have large psychosocial effects? Acad Radiol 10:1257–1266PubMedCrossRef Currence BV, Pisano ED, Earp JA, Moore A, Chiu YF, Brown ME, Kurgat KL (2003) Does biopsy, aspiration or six month follow-up of a false-positive mammogram reduce future screening or have large psychosocial effects? Acad Radiol 10:1257–1266PubMedCrossRef
14.
Zurück zum Zitat Brett J, Austoker J, Ong G (1998) Do women who undergo further investigation for breast screening suffer adverse psychological consequences? A multi-centre follow-up study comparing different breast screening result groups five months after their last breast screening appointment. J Public Health Med 20:396–403PubMed Brett J, Austoker J, Ong G (1998) Do women who undergo further investigation for breast screening suffer adverse psychological consequences? A multi-centre follow-up study comparing different breast screening result groups five months after their last breast screening appointment. J Public Health Med 20:396–403PubMed
15.
Zurück zum Zitat Brett J, Austoker J (2001) Women who are recalled for further investigations for breast screening: psychological consequences 3 years after recall and factors affecting re-attendance. J Public Health Med 23:292–300PubMedCrossRef Brett J, Austoker J (2001) Women who are recalled for further investigations for breast screening: psychological consequences 3 years after recall and factors affecting re-attendance. J Public Health Med 23:292–300PubMedCrossRef
16.
Zurück zum Zitat Vizcaino I, Gadea L, Andreo L et al (2001) Short-term follow-up results in 795 non palpable probably benign lesions detected at screening mammography. Radiology 219:475–483PubMed Vizcaino I, Gadea L, Andreo L et al (2001) Short-term follow-up results in 795 non palpable probably benign lesions detected at screening mammography. Radiology 219:475–483PubMed
17.
Zurück zum Zitat Helbich TH, Pfarl G, Lomosschitz F, Stadler A, Rudas M, Wolf G (2000) Role of core needle breast biopsy in probably benign lesions. Radiology 219:475–483 Helbich TH, Pfarl G, Lomosschitz F, Stadler A, Rudas M, Wolf G (2000) Role of core needle breast biopsy in probably benign lesions. Radiology 219:475–483
18.
Zurück zum Zitat Consolidated Guidance on Standards for the NHS Breast Screening Programme (2005) NHSBSP Publication 60(2) Consolidated Guidance on Standards for the NHS Breast Screening Programme (2005) NHSBSP Publication 60(2)
19.
Zurück zum Zitat European Guidelines for Quality Assurance in Mammography Screening (2001) 3rd Edition, Office for Official Publications of the European Communities European Guidelines for Quality Assurance in Mammography Screening (2001) 3rd Edition, Office for Official Publications of the European Communities
20.
Zurück zum Zitat Perry NM (2001) Quality assurance in the diagnosis of breast disease. EUSOMA Working Party. Eur J Cancer 37:159–172PubMedCrossRef Perry NM (2001) Quality assurance in the diagnosis of breast disease. EUSOMA Working Party. Eur J Cancer 37:159–172PubMedCrossRef
24.
Zurück zum Zitat Liberman L, Benton CL, Dershaw DD, Abramson AF, LaTrenta LR, Morris EA (2001) Learning curve for stereotactic breast biopsy: how many cases are enough?. AJR Am J Roentgenol 176(3):721–727PubMed Liberman L, Benton CL, Dershaw DD, Abramson AF, LaTrenta LR, Morris EA (2001) Learning curve for stereotactic breast biopsy: how many cases are enough?. AJR Am J Roentgenol 176(3):721–727PubMed
25.
Zurück zum Zitat Harcourt D, Ambler N, Rumsey N, Cawthorn SJ (1998) Evaluation of a one-stop breast lump clinic: a randomized controlled trial. Breast 7:314–319CrossRef Harcourt D, Ambler N, Rumsey N, Cawthorn SJ (1998) Evaluation of a one-stop breast lump clinic: a randomized controlled trial. Breast 7:314–319CrossRef
26.
Zurück zum Zitat Litherland JC, Evans AJ, Wilson ARM et al (1966) The impact of core-biopsy on pre-operative diagnosis rate of screen detected breast cancers. Clin Radiol 51:562–565CrossRef Litherland JC, Evans AJ, Wilson ARM et al (1966) The impact of core-biopsy on pre-operative diagnosis rate of screen detected breast cancers. Clin Radiol 51:562–565CrossRef
27.
Zurück zum Zitat Jones L, Lott MF, Calder CJ, Kutt E (2004) Imprint cytology from ultrasound guided core biopsies: accurate and immediate diagnosis in a one stop breast clinic. Clin Radiol 59:903–908PubMedCrossRef Jones L, Lott MF, Calder CJ, Kutt E (2004) Imprint cytology from ultrasound guided core biopsies: accurate and immediate diagnosis in a one stop breast clinic. Clin Radiol 59:903–908PubMedCrossRef
28.
Zurück zum Zitat Klevesath MB, Godwin RJ, Bannon R, Munthali L, Coveney E (2005) Touch imprint cytology of core needle biopsy specimens: a useful method for immediate reporting of symptomatic breast lesions. Eur J Surg Oncol 31(5):490–494PubMedCrossRef Klevesath MB, Godwin RJ, Bannon R, Munthali L, Coveney E (2005) Touch imprint cytology of core needle biopsy specimens: a useful method for immediate reporting of symptomatic breast lesions. Eur J Surg Oncol 31(5):490–494PubMedCrossRef
29.
Zurück zum Zitat Ragazzini T, Magrini E, Cucchi MC, Foschini MP, Eusebi V (2005) The fast-track biopsy (FTB); description of a rapid histology and immunohistochemistry method for evaluation of preoperative breast core biopies. Int J Surg Pathol 13(3):247–252PubMedCrossRef Ragazzini T, Magrini E, Cucchi MC, Foschini MP, Eusebi V (2005) The fast-track biopsy (FTB); description of a rapid histology and immunohistochemistry method for evaluation of preoperative breast core biopies. Int J Surg Pathol 13(3):247–252PubMedCrossRef
30.
Zurück zum Zitat Gianna L, Zambretti M, Clark K et al (2005) Gene expression profiles in paraffin-embedded core biopsy tissue predict response to chemotherapy in women with locally advanced breast cancer. J Clin Oncol 23:7265–7277CrossRef Gianna L, Zambretti M, Clark K et al (2005) Gene expression profiles in paraffin-embedded core biopsy tissue predict response to chemotherapy in women with locally advanced breast cancer. J Clin Oncol 23:7265–7277CrossRef
31.
Zurück zum Zitat Zafar N, Jamal S, Mamoon N, Luqman M, Anwar M (2005) Typing and grading of cytological category C5 breast lesions. J Coll Physicians Surg Pak 15:221–224PubMed Zafar N, Jamal S, Mamoon N, Luqman M, Anwar M (2005) Typing and grading of cytological category C5 breast lesions. J Coll Physicians Surg Pak 15:221–224PubMed
32.
Zurück zum Zitat Hunt CM, Ellis IO, Elston CW et al (1990) Cytological grading of breast carcinomas-a feasible proposition? Cytopatology 1:287–295CrossRef Hunt CM, Ellis IO, Elston CW et al (1990) Cytological grading of breast carcinomas-a feasible proposition? Cytopatology 1:287–295CrossRef
33.
Zurück zum Zitat Zagorianakou P, Fiaccavento S, Zagorianakou G, Makrydimas G, Agnantis NJ (2005) FNAC: Its role, limitations and perspective in the pre-operative diagnosis of breast cancer. Eur J Gynaecol Oncol 26:143–149PubMed Zagorianakou P, Fiaccavento S, Zagorianakou G, Makrydimas G, Agnantis NJ (2005) FNAC: Its role, limitations and perspective in the pre-operative diagnosis of breast cancer. Eur J Gynaecol Oncol 26:143–149PubMed
34.
Zurück zum Zitat Abu-Salem OT (2002) Fine needle aspiration cytology (FNAB) of breast lumps: comparison study between pre- and post-operative histological diagnosis. Arch Inst Pasteur Tunis 79:59–63PubMed Abu-Salem OT (2002) Fine needle aspiration cytology (FNAB) of breast lumps: comparison study between pre- and post-operative histological diagnosis. Arch Inst Pasteur Tunis 79:59–63PubMed
35.
Zurück zum Zitat Ljung B-M, Drejet A, Chiampi N et al (2001) Diagnostic accuracy of FNAC is determined by physician training in sampling technique. Cancer 93:263–268PubMedCrossRef Ljung B-M, Drejet A, Chiampi N et al (2001) Diagnostic accuracy of FNAC is determined by physician training in sampling technique. Cancer 93:263–268PubMedCrossRef
36.
Zurück zum Zitat Heywang-Köbrunner SH, Schreer I (eds.) (2003) Bildgebende Mammadiagnostik. Untersuchungstechnik, Befundmuster und Differentialdiagnostik in Mammaographie, Sonographie und Kernspintomographie. Stuttgart: Thieme, second edition Heywang-Köbrunner SH, Schreer I (eds.) (2003) Bildgebende Mammadiagnostik. Untersuchungstechnik, Befundmuster und Differentialdiagnostik in Mammaographie, Sonographie und Kernspintomographie. Stuttgart: Thieme, second edition
37.
Zurück zum Zitat Non-operative Sub-Group of the National Co-ordinating Committee for Breast Screening Pathology. Guidelines for non-operative diagnostic Procedures and Reporting in Breast Cancer Screening. Sheffield, NHS Breast Screening Programme (2001) NHSBSP Publication No 50:8–13 Non-operative Sub-Group of the National Co-ordinating Committee for Breast Screening Pathology. Guidelines for non-operative diagnostic Procedures and Reporting in Breast Cancer Screening. Sheffield, NHS Breast Screening Programme (2001) NHSBSP Publication No 50:8–13
38.
Zurück zum Zitat Nicholson S, Sainsbury JR, Wadehra V, Needham GK, Farndon JR (1998) Use of fine needle aspiration cytology with immediate reporting in the diagnosis of breast disease. Br J Surg 75:847–850CrossRef Nicholson S, Sainsbury JR, Wadehra V, Needham GK, Farndon JR (1998) Use of fine needle aspiration cytology with immediate reporting in the diagnosis of breast disease. Br J Surg 75:847–850CrossRef
39.
Zurück zum Zitat Dehn TC, Clarke J, Dixon JM, Cucioli V, Greenhall, Lee EC (1987) Fine needle aspiration cytology, with immediate reporting, in the outpatient diagnosis of breast disease. Ann R Coll Surg Engl 69:280–282PubMed Dehn TC, Clarke J, Dixon JM, Cucioli V, Greenhall, Lee EC (1987) Fine needle aspiration cytology, with immediate reporting, in the outpatient diagnosis of breast disease. Ann R Coll Surg Engl 69:280–282PubMed
40.
Zurück zum Zitat Pilgrim S, Ravichandran D (2004) Fine needle aspiration cytology as an adjunct to core biopsy in the assessment of symptomatic breast cancer. Breast 14:411–414CrossRef Pilgrim S, Ravichandran D (2004) Fine needle aspiration cytology as an adjunct to core biopsy in the assessment of symptomatic breast cancer. Breast 14:411–414CrossRef
41.
Zurück zum Zitat Melotti MK, Berg WA (2001) Core needle breast biopsy in patients undergoing anticoagulation therapy: preliminary results. AJR Am J Roentgenol 174:245–249 Melotti MK, Berg WA (2001) Core needle breast biopsy in patients undergoing anticoagulation therapy: preliminary results. AJR Am J Roentgenol 174:245–249
42.
Zurück zum Zitat Parker SH, Jobe WE, Dennis MA et al (1993) US-guided automated large-core breast biopsy. Radiology 187:507–511PubMed Parker SH, Jobe WE, Dennis MA et al (1993) US-guided automated large-core breast biopsy. Radiology 187:507–511PubMed
43.
Zurück zum Zitat Liberman L, Hann LE, Dershaw DD, Morris EA, Abramson AF, Rosen PP (1997) Mammographic findings after stereotactic 14-gauge vacuum biopsy. Radiology 203:343–347PubMed Liberman L, Hann LE, Dershaw DD, Morris EA, Abramson AF, Rosen PP (1997) Mammographic findings after stereotactic 14-gauge vacuum biopsy. Radiology 203:343–347PubMed
44.
Zurück zum Zitat Helbich TH, Rudas M, Haitel A, Kohlberger PD, Thurnher M, Gnant M, Wunderbaldinger P, Wolf G, Mostbeck GH (1998) Evaluation of needle size for breast biopsy: comparison of 14-, 16-, and 18-gauge biopsy needles. AJR Am J Roentgenol 171:59–63PubMed Helbich TH, Rudas M, Haitel A, Kohlberger PD, Thurnher M, Gnant M, Wunderbaldinger P, Wolf G, Mostbeck GH (1998) Evaluation of needle size for breast biopsy: comparison of 14-, 16-, and 18-gauge biopsy needles. AJR Am J Roentgenol 171:59–63PubMed
45.
Zurück zum Zitat Liberman L, Evans WP 3rd, Dershaw DD et al (1994) Radiography of microcalcifications in stereotaxic mammary core biopsy specimens. Radiology 190(1):223–225PubMed Liberman L, Evans WP 3rd, Dershaw DD et al (1994) Radiography of microcalcifications in stereotaxic mammary core biopsy specimens. Radiology 190(1):223–225PubMed
46.
Zurück zum Zitat Reynolds HE (2000) Core needle biopsy challenging benign breast conditions: a comprehensive literature review. AJR Am J Roentgenol 174:1245–1250PubMed Reynolds HE (2000) Core needle biopsy challenging benign breast conditions: a comprehensive literature review. AJR Am J Roentgenol 174:1245–1250PubMed
47.
Zurück zum Zitat Lorenzen J, Welger J, Lisboa BW, Rietohof L, Grzyska B, Adam G (2002) Percutaneous core-needle biopsy of palpable breast tumours. Do we need ultrasound guidance? Rofo 174:1142–1146PubMed Lorenzen J, Welger J, Lisboa BW, Rietohof L, Grzyska B, Adam G (2002) Percutaneous core-needle biopsy of palpable breast tumours. Do we need ultrasound guidance? Rofo 174:1142–1146PubMed
48.
Zurück zum Zitat Agarwal T, Patel B, Rajan P et al (2003) Core biopsy versus FNAC for palpable breast cancers. Is image guidance necessary? Eur J Cancer 39:52–56PubMedCrossRef Agarwal T, Patel B, Rajan P et al (2003) Core biopsy versus FNAC for palpable breast cancers. Is image guidance necessary? Eur J Cancer 39:52–56PubMedCrossRef
49.
Zurück zum Zitat LaTrenta LR, Menell JH, Morris EA, Abramson AF, Dershaw DD, Liberman L (2003) Breast lesions detected with MR imaging: utility and histopathologic importance of identification with US. Radiology 227(3):856–861PubMedCrossRef LaTrenta LR, Menell JH, Morris EA, Abramson AF, Dershaw DD, Liberman L (2003) Breast lesions detected with MR imaging: utility and histopathologic importance of identification with US. Radiology 227(3):856–861PubMedCrossRef
50.
Zurück zum Zitat Dhamanaskar KP, Muradall D (2002) MRI directed ultrasound: a cost effective method for diagnosis and intervention in breast imaging [abstract]. Radiology 225:653 Dhamanaskar KP, Muradall D (2002) MRI directed ultrasound: a cost effective method for diagnosis and intervention in breast imaging [abstract]. Radiology 225:653
51.
Zurück zum Zitat Panizza P, De Gaspari A (1997) Accuracy of post MR imaging second-look sonography in previously undetected breast lesions [abstract]. Radiology 205:489 Panizza P, De Gaspari A (1997) Accuracy of post MR imaging second-look sonography in previously undetected breast lesions [abstract]. Radiology 205:489
52.
Zurück zum Zitat Khul CK, Bieling HB, Gieseke J et al (1977) Healthy premenopausal breast parenchyma in dynamic contrast-enhanced MR imaging of the breast: normal contrast medium enhancement and cyclical-phase dependency. Radiology 203:137–144 Khul CK, Bieling HB, Gieseke J et al (1977) Healthy premenopausal breast parenchyma in dynamic contrast-enhanced MR imaging of the breast: normal contrast medium enhancement and cyclical-phase dependency. Radiology 203:137–144
53.
Zurück zum Zitat Burbank F, Forcier N (1997) Tissue marking clip for stereotactic breast biopsy: initial placement accuracy, long-term stability, and usefulness as a guide for wire localization. Radiology 205:407–415PubMed Burbank F, Forcier N (1997) Tissue marking clip for stereotactic breast biopsy: initial placement accuracy, long-term stability, and usefulness as a guide for wire localization. Radiology 205:407–415PubMed
54.
Zurück zum Zitat Catania S, Boccato P, Bono A et al (1989) Pneumothorax: a rare complication of fine needle aspiration of the breast. Acta Cytol 33(1):140PubMed Catania S, Boccato P, Bono A et al (1989) Pneumothorax: a rare complication of fine needle aspiration of the breast. Acta Cytol 33(1):140PubMed
55.
Zurück zum Zitat Witt A, Yavuz D, Walchetseder C, Strohmer H, Kubista E (2003) Preoperative core needle biopsy as an independent risk factor for wound infection after breast surgery. Obstet Gynecol 101(4):745–750PubMedCrossRef Witt A, Yavuz D, Walchetseder C, Strohmer H, Kubista E (2003) Preoperative core needle biopsy as an independent risk factor for wound infection after breast surgery. Obstet Gynecol 101(4):745–750PubMedCrossRef
56.
Zurück zum Zitat Liberman L, Vuolo M, Dershaw DD et al (1999) Epithelial displacement after stereotactic 11-gauge directional vacuum-assisted breast biopsy. AJR Am J Roentgenol 172:677–681PubMed Liberman L, Vuolo M, Dershaw DD et al (1999) Epithelial displacement after stereotactic 11-gauge directional vacuum-assisted breast biopsy. AJR Am J Roentgenol 172:677–681PubMed
57.
Zurück zum Zitat Preece PE, Hunter SM, Duigood HLD, Wood RAB (1998) Cytodiagnosis and other methods of biopsy in the modern management of breast cancer. Sem Surg Oncol 5:69–81CrossRef Preece PE, Hunter SM, Duigood HLD, Wood RAB (1998) Cytodiagnosis and other methods of biopsy in the modern management of breast cancer. Sem Surg Oncol 5:69–81CrossRef
58.
Zurück zum Zitat Pfarl G, Helbich TH, Riedl CC, Guth-Wagner T, Gnant M, Rudas M, Liberman L (2002) Stereotactic 11-gauge vacuum-assisted breast biopsy: a validation study. AJR Am J Roentgenol 179:1503–1507PubMed Pfarl G, Helbich TH, Riedl CC, Guth-Wagner T, Gnant M, Rudas M, Liberman L (2002) Stereotactic 11-gauge vacuum-assisted breast biopsy: a validation study. AJR Am J Roentgenol 179:1503–1507PubMed
59.
Zurück zum Zitat Liberman L, Dershaw DD, Rosen PP, Abramson AF, Deutch BM, Hann LE (1994) Stereotaxic 14-gauge breast biopsy: how many core biopsy specimens are needed? Radiology 192:793–795PubMed Liberman L, Dershaw DD, Rosen PP, Abramson AF, Deutch BM, Hann LE (1994) Stereotaxic 14-gauge breast biopsy: how many core biopsy specimens are needed? Radiology 192:793–795PubMed
60.
Zurück zum Zitat Liberman L, Smolkin JH, Dershaw DD, Morris EA, Abramson AF, Rosen PP (1998) Calcification retrieval at stereotactic, 11-gauge, directional, vacuum-assisted breast biopsy. Radiology 208:251–260PubMed Liberman L, Smolkin JH, Dershaw DD, Morris EA, Abramson AF, Rosen PP (1998) Calcification retrieval at stereotactic, 11-gauge, directional, vacuum-assisted breast biopsy. Radiology 208:251–260PubMed
61.
Zurück zum Zitat Fishman JE, Milikowski C, Ramsinghani R, Velasquez V, Aviram G (2003) US-guided core-needle biopsy of the breast: how many specimens are necessary? Radiology 226:779–782PubMedCrossRef Fishman JE, Milikowski C, Ramsinghani R, Velasquez V, Aviram G (2003) US-guided core-needle biopsy of the breast: how many specimens are necessary? Radiology 226:779–782PubMedCrossRef
62.
Zurück zum Zitat Rosen EL, Bentley RC, Baker JA, Scott, Soo M (2002) Image-guided core needle biopsy of papillary lesions of the breast. AJR Am J Roentgenol 179:1185–1192PubMed Rosen EL, Bentley RC, Baker JA, Scott, Soo M (2002) Image-guided core needle biopsy of papillary lesions of the breast. AJR Am J Roentgenol 179:1185–1192PubMed
63.
Zurück zum Zitat Bagnall MJC, Evans AJ, Wilson ARM et al (2000) When have mammographic calcifications been adequately sampled at core biopsy? Clin Radiol 55:543–548CrossRef Bagnall MJC, Evans AJ, Wilson ARM et al (2000) When have mammographic calcifications been adequately sampled at core biopsy? Clin Radiol 55:543–548CrossRef
64.
Zurück zum Zitat Liberman L, Kaplan JB, Morris EA, Abramson AF, Menell JH, Dershaw DD (2002) To excise or to sample the mammographic target: what is the goal of stereotactic 11-gauge vacuum-assisted breast biopsy? AJR Am J Roentgenol 179:679–683PubMed Liberman L, Kaplan JB, Morris EA, Abramson AF, Menell JH, Dershaw DD (2002) To excise or to sample the mammographic target: what is the goal of stereotactic 11-gauge vacuum-assisted breast biopsy? AJR Am J Roentgenol 179:679–683PubMed
65.
Zurück zum Zitat Lomosschitz FM, Helbich TH, Rudas M, Stadler A, Pfarl G, Wolf G (2000) Stereotactic directional vacuum assisted breast biopsy: How many specimens do we need? Radiology 217:527 Lomosschitz FM, Helbich TH, Rudas M, Stadler A, Pfarl G, Wolf G (2000) Stereotactic directional vacuum assisted breast biopsy: How many specimens do we need? Radiology 217:527
66.
Zurück zum Zitat Liberman L, Sarna MP (2000) Cost effectiveness of stereotactic 11-gauge directional vacuum-assisted breast biopsy. AJR Am J Roentgenol 175:53–58PubMed Liberman L, Sarna MP (2000) Cost effectiveness of stereotactic 11-gauge directional vacuum-assisted breast biopsy. AJR Am J Roentgenol 175:53–58PubMed
67.
Zurück zum Zitat Teh WL, Shah BKS, Michell MJ et al Prospective randomised study of stereotactic breast biopsy using 14G core biopsy and 11G vacuum-assisted biopsy: The UK Mammotome trial. Clin Rad (in press) Teh WL, Shah BKS, Michell MJ et al Prospective randomised study of stereotactic breast biopsy using 14G core biopsy and 11G vacuum-assisted biopsy: The UK Mammotome trial. Clin Rad (in press)
68.
Zurück zum Zitat Mayers MM, Sloane JP (1993) Carcinoma and atypical hyperplasia in radial scars and complex sclerosing lesions: importance of lesion size and patient age. Histopathology 23:225–231PubMedCrossRef Mayers MM, Sloane JP (1993) Carcinoma and atypical hyperplasia in radial scars and complex sclerosing lesions: importance of lesion size and patient age. Histopathology 23:225–231PubMedCrossRef
69.
Zurück zum Zitat Philpotts LE, Shaheen NA, Jain KS, Carter D, Lee CH (2000) Uncommon high-risk lesions of the breast diagnosed at stereotactic core-needle biopsy: clinical importance. Radiology 216:831–837PubMed Philpotts LE, Shaheen NA, Jain KS, Carter D, Lee CH (2000) Uncommon high-risk lesions of the breast diagnosed at stereotactic core-needle biopsy: clinical importance. Radiology 216:831–837PubMed
70.
Zurück zum Zitat Dennis MA, Parker S, Kaske TI, Stavros AT, Camp J (2000) Incidental treatment of nipple discharge caused by intraduct papilloma through diagnostic mammotome biopsy. AJR Am J Roentgenol 174:1263–1268PubMed Dennis MA, Parker S, Kaske TI, Stavros AT, Camp J (2000) Incidental treatment of nipple discharge caused by intraduct papilloma through diagnostic mammotome biopsy. AJR Am J Roentgenol 174:1263–1268PubMed
71.
Zurück zum Zitat Cawson JN, Frank M, Kavanagh A, Hill P, Balasubramanium G, Henderson M (2003) Fourteen-gauge needle core biopsy of mammographically evident radial scars: is excision necessary? Cancer 97(2):345–351PubMedCrossRef Cawson JN, Frank M, Kavanagh A, Hill P, Balasubramanium G, Henderson M (2003) Fourteen-gauge needle core biopsy of mammographically evident radial scars: is excision necessary? Cancer 97(2):345–351PubMedCrossRef
72.
Zurück zum Zitat Kirwan SE, Denton ERE, Nash RM, Humphreys S, Michell MJ (2000) Multiple 14G stereotactic core biopsies in the diagnosis of mammographically detected stellate lesions of the breast. Clin Radiol 55:763–766PubMedCrossRef Kirwan SE, Denton ERE, Nash RM, Humphreys S, Michell MJ (2000) Multiple 14G stereotactic core biopsies in the diagnosis of mammographically detected stellate lesions of the breast. Clin Radiol 55:763–766PubMedCrossRef
73.
Zurück zum Zitat Brenner RJ, Jackman RJ, Parker SH et al (2002) Percutaneous core needle biopsy of radial scars of the breast: when is excision necessary? AJR Am J Roentgenol 179:1179–1184PubMed Brenner RJ, Jackman RJ, Parker SH et al (2002) Percutaneous core needle biopsy of radial scars of the breast: when is excision necessary? AJR Am J Roentgenol 179:1179–1184PubMed
74.
Zurück zum Zitat Collins CD (2005) The sentinel node in breast cancer: an update. Cancer Imaging 5: Spec No A:S3–S9PubMed Collins CD (2005) The sentinel node in breast cancer: an update. Cancer Imaging 5: Spec No A:S3–S9PubMed
75.
Zurück zum Zitat Kim T, Giuliano AE, Lyman GH (2006) Lymphatic mapping and sentinel lymph node biopsy in early-stage breast cancer. Cancer 1:4–16CrossRef Kim T, Giuliano AE, Lyman GH (2006) Lymphatic mapping and sentinel lymph node biopsy in early-stage breast cancer. Cancer 1:4–16CrossRef
76.
Zurück zum Zitat Veronesi U, Galimberti V, Mariani L, Gatti G, Paganelli G et al (2005) Sentinel node biopsy in breast cancer: early results in 953 patients with negative sentinel node biopsy and no axillary dissection. Eur J Cancer 41:197–198CrossRef Veronesi U, Galimberti V, Mariani L, Gatti G, Paganelli G et al (2005) Sentinel node biopsy in breast cancer: early results in 953 patients with negative sentinel node biopsy and no axillary dissection. Eur J Cancer 41:197–198CrossRef
77.
Zurück zum Zitat Viale G, Mastropasqua MG, Maiorano E, Mazzarol G (2005) Pathological examination of the axillary sentinel lymphnodes with early-stage breast carcinoma: current and resolving controversies on the basis of the European Institute of Oncology experience. Virchows Archiv 448(3):241–247PubMedCrossRef Viale G, Mastropasqua MG, Maiorano E, Mazzarol G (2005) Pathological examination of the axillary sentinel lymphnodes with early-stage breast carcinoma: current and resolving controversies on the basis of the European Institute of Oncology experience. Virchows Archiv 448(3):241–247PubMedCrossRef
78.
Zurück zum Zitat Damera A, Evans AJ, Cornford EJ, Wison AR, Burrell HC et al (2003) Diagnosis of axillary nodal metastases by ultrasound core biopsy in primary operable breast cancer. Br J Cancer 89:1310–1313PubMedCrossRef Damera A, Evans AJ, Cornford EJ, Wison AR, Burrell HC et al (2003) Diagnosis of axillary nodal metastases by ultrasound core biopsy in primary operable breast cancer. Br J Cancer 89:1310–1313PubMedCrossRef
79.
Zurück zum Zitat Keuen-Boumeester V, Menke-Pluymers M, de Kanter AY, Obdeijn IM et al (2003) Ultrasound-guided fine needle aspiration cytology of axillary lymph nodes in breast cancer patients. A preoperative staging procedure. Eur J Cancer 39:170–174CrossRef Keuen-Boumeester V, Menke-Pluymers M, de Kanter AY, Obdeijn IM et al (2003) Ultrasound-guided fine needle aspiration cytology of axillary lymph nodes in breast cancer patients. A preoperative staging procedure. Eur J Cancer 39:170–174CrossRef
80.
Zurück zum Zitat Deurloo EE, Tanis PJ, Gilhuijs KG, Muller SH, Kroger R et al (2003) Reduction in the number of sentinel node procedures by preoperative ultrasonography of the axilla in breast cancer. Eur J Cancer 39:1037–1038CrossRef Deurloo EE, Tanis PJ, Gilhuijs KG, Muller SH, Kroger R et al (2003) Reduction in the number of sentinel node procedures by preoperative ultrasonography of the axilla in breast cancer. Eur J Cancer 39:1037–1038CrossRef
81.
Zurück zum Zitat Helbich TH, Buchberger W, Rudas M (2002) Österreichisches Konsensuspapier: Stereotaktisch und Ultraschallgezielte Vakuumbiopsie von Brustläsionen. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:517–521PubMed Helbich TH, Buchberger W, Rudas M (2002) Österreichisches Konsensuspapier: Stereotaktisch und Ultraschallgezielte Vakuumbiopsie von Brustläsionen. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:517–521PubMed
82.
Zurück zum Zitat American College of Radiology (2003) Illustrated breast imaging reporting and data system (BI-RADS™). 4th edition. Reston, VA: American College of Radiology American College of Radiology (2003) Illustrated breast imaging reporting and data system (BI-RADS™). 4th edition. Reston, VA: American College of Radiology
Metadaten
Titel
Guidelines from the European Society of Breast Imaging for diagnostic interventional breast procedures
verfasst von
Matthew Wallis
Anne Tarvidon
Thomas Helbich
Ingrid Schreer
Publikationsdatum
01.02.2007
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 2/2007
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0408-x

Weitere Artikel der Ausgabe 2/2007

European Radiology 2/2007 Zur Ausgabe

Acknowledgement to Reviewers

Acknowledgement to Reviewers

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.