Abstract

Local thermal therapies are increasingly used in the clinic for tissue ablation. During energy deposition, the actual tissue temperature is difficult to estimate since physiological processes may modify local heat conduction and energy absorption. Blood flow may increase during temperature increase and thus change heat conduction. In order to improve the therapeutic efficiency and the safety of the intervention, mapping of temperature and thermal dose appear to offer the best strategy to optimize such interventions and to provide therapy endpoints. MRI can be used to monitor local temperature changes during thermal therapies. On-line availability of dynamic temperature mapping allows prediction of tissue death during the intervention based on semi-empirical thermal dose calculations. Much progress has been made recently in MR thermometry research, and some applications are appearing in the clinic. In this paper, the principles of MRI temperature mapping are described with special emphasis on methods employing the temperature dependency of the water proton resonance frequency. Then, the prospects and requirements for widespread applications of MR thermometry in the clinic are evaluated.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Lele PP (1967) Production of deep focal lesions by focused ultrasound current status. Ultrasonics 5:105–112PubMedCrossRef Lele PP (1967) Production of deep focal lesions by focused ultrasound current status. Ultrasonics 5:105–112PubMedCrossRef
2.
Zurück zum Zitat Dodd GD, Soulen MC, Kane RA, Livraghi T, Lees WR, Yamashita Y, Gillams AR, Karahan OI, Rhim H (2000) Minimally invasive treatment of malignant hepatic tumors: at the threshold of a major breakthrough. Radiographics 20(1):9–27PubMed Dodd GD, Soulen MC, Kane RA, Livraghi T, Lees WR, Yamashita Y, Gillams AR, Karahan OI, Rhim H (2000) Minimally invasive treatment of malignant hepatic tumors: at the threshold of a major breakthrough. Radiographics 20(1):9–27PubMed
4.
Zurück zum Zitat Memarsadeghi M, Schmook T, Remzi M, Weber M, Potscher G, Lammer J, Kettenbach J (2006) Percutaneous radiofrequency ablation of renal tumors: midterm results in 16 patients. Eur J Radiol 59(2):183–189PubMedCrossRef Memarsadeghi M, Schmook T, Remzi M, Weber M, Potscher G, Lammer J, Kettenbach J (2006) Percutaneous radiofrequency ablation of renal tumors: midterm results in 16 patients. Eur J Radiol 59(2):183–189PubMedCrossRef
5.
Zurück zum Zitat Mulier S, Ni Y, Frich L, Burdio F, Denys AL, De Wispelaere JF, Dupas B, Habib N, Hoey M, Jansen MC, Lacrosse M, Leveillee R, Miao Y, Mulier P, Mutter D, Ng KK, Santambrogio R, Stippel D, Tamaki K, van Gulik TM, Marchal G, Michel L (2007) Experimental and clinical radiofrequency ablation: proposal for standardized description of coagulation size and geometry. Ann Surg Oncol Mulier S, Ni Y, Frich L, Burdio F, Denys AL, De Wispelaere JF, Dupas B, Habib N, Hoey M, Jansen MC, Lacrosse M, Leveillee R, Miao Y, Mulier P, Mutter D, Ng KK, Santambrogio R, Stippel D, Tamaki K, van Gulik TM, Marchal G, Michel L (2007) Experimental and clinical radiofrequency ablation: proposal for standardized description of coagulation size and geometry. Ann Surg Oncol
6.
Zurück zum Zitat Tempany CM, Stewart EA, McDannold N, Quade BJ, Jolesz FA, Hynynen K (2003) MR imaging-guided focused ultrasound surgery of uterine leiomyomas: a feasibility study. Radiology 226(3):897–905. MarPubMedCrossRef Tempany CM, Stewart EA, McDannold N, Quade BJ, Jolesz FA, Hynynen K (2003) MR imaging-guided focused ultrasound surgery of uterine leiomyomas: a feasibility study. Radiology 226(3):897–905. MarPubMedCrossRef
7.
Zurück zum Zitat Stewart EA, Rabinovici J, Tempany CMC, Inbar Y, Regan L, Gastout B, Hesley G, Kim HS, Hengst S, Gedroye WM (2006) Clinical outcomes of focused ultrasound surgery for the treatment of uterine fibroids. Fertil Steril 85(1):22–29PubMedCrossRef Stewart EA, Rabinovici J, Tempany CMC, Inbar Y, Regan L, Gastout B, Hesley G, Kim HS, Hengst S, Gedroye WM (2006) Clinical outcomes of focused ultrasound surgery for the treatment of uterine fibroids. Fertil Steril 85(1):22–29PubMedCrossRef
8.
Zurück zum Zitat Furusawa H, Namba K, Thomsen S, Akiyama F, Bendet A, Tanaka C, Yasuda Y, Nakahara H (2006) Magnetic resonance-guided focused ultrasound surgery of breast cancer: reliability and effectiveness. J Am Coll Surg 203(1):54–63PubMedCrossRef Furusawa H, Namba K, Thomsen S, Akiyama F, Bendet A, Tanaka C, Yasuda Y, Nakahara H (2006) Magnetic resonance-guided focused ultrasound surgery of breast cancer: reliability and effectiveness. J Am Coll Surg 203(1):54–63PubMedCrossRef
9.
Zurück zum Zitat Zippel DB, Papa MZ (2005) The use of MR imaging guided focused ultrasound in breast cancer patients; a preliminary phase one study and review. Breast Cancer 12:32–38PubMedCrossRef Zippel DB, Papa MZ (2005) The use of MR imaging guided focused ultrasound in breast cancer patients; a preliminary phase one study and review. Breast Cancer 12:32–38PubMedCrossRef
10.
Zurück zum Zitat Uchida T, Ohkusa H, Yamashita H, Shoji S, Nagata Y, Hyodo T, Satoh T (2006) Five years experience of transrectal high-intensity focused ultrasound using the Sonablate device in the treatment of localized prostate cancer. Int J Urol 13(3):228–233PubMedCrossRef Uchida T, Ohkusa H, Yamashita H, Shoji S, Nagata Y, Hyodo T, Satoh T (2006) Five years experience of transrectal high-intensity focused ultrasound using the Sonablate device in the treatment of localized prostate cancer. Int J Urol 13(3):228–233PubMedCrossRef
11.
Zurück zum Zitat Kennedy JE, Wu F, ter Haar GR, Gleeson FV, Phillips RR, Middleton MR, Cranston D (2004) High-intensity focused ultrasound for the treatment of liver tumours. Ultrasonics 42(1–9):931–935PubMedCrossRef Kennedy JE, Wu F, ter Haar GR, Gleeson FV, Phillips RR, Middleton MR, Cranston D (2004) High-intensity focused ultrasound for the treatment of liver tumours. Ultrasonics 42(1–9):931–935PubMedCrossRef
12.
Zurück zum Zitat Hacker A, Michel MS, Marlinghaus E, Kohrmann KU, Alken P (2006) Extracorporeally induced ablation of renal tissue by high-intensity focused ultrasound. BJU Int 97(4):779–785PubMedCrossRef Hacker A, Michel MS, Marlinghaus E, Kohrmann KU, Alken P (2006) Extracorporeally induced ablation of renal tissue by high-intensity focused ultrasound. BJU Int 97(4):779–785PubMedCrossRef
13.
Zurück zum Zitat Wu F, Wang ZB et al (2003) Non-invasive ablation of high intensity focused ultrasound for the treatment of patients with malignant bone tumours. J Bone Joint Surg (Br) 87-B(Issue Supp I):4 Wu F, Wang ZB et al (2003) Non-invasive ablation of high intensity focused ultrasound for the treatment of patients with malignant bone tumours. J Bone Joint Surg (Br) 87-B(Issue Supp I):4
14.
Zurück zum Zitat Wang X, Sun J (2002) High-intensity focused ultrasound in patients with late-stage pancreatic carcinoma. Chin Med J (Engl) 115(9):1332–1335 Wang X, Sun J (2002) High-intensity focused ultrasound in patients with late-stage pancreatic carcinoma. Chin Med J (Engl) 115(9):1332–1335
15.
Zurück zum Zitat Guilhon E, Quesson B, Moraud-Gaudry F, de Verneuil H, Canioni P, Salomir R, Voisin P, Moonen CTW (2003) Image-guided control of transgene expression based on local hyperthermia. J Molecular Imaging 2(1):11–17CrossRef Guilhon E, Quesson B, Moraud-Gaudry F, de Verneuil H, Canioni P, Salomir R, Voisin P, Moonen CTW (2003) Image-guided control of transgene expression based on local hyperthermia. J Molecular Imaging 2(1):11–17CrossRef
16.
Zurück zum Zitat Madio DP, Van Gelderen P, DesPres D, Olson AW, de Zwart JA, Fawcett TW, Holbrook N, Mandel M, Moonen CTW (1998) On the feasibility of MRI-guided focused ultrasound for local induction of gene expression. J Magn Reson Imaging 8:101–104PubMedCrossRef Madio DP, Van Gelderen P, DesPres D, Olson AW, de Zwart JA, Fawcett TW, Holbrook N, Mandel M, Moonen CTW (1998) On the feasibility of MRI-guided focused ultrasound for local induction of gene expression. J Magn Reson Imaging 8:101–104PubMedCrossRef
17.
Zurück zum Zitat Sapareto SA, Dewey WCL (1984) Thermal dose determination in cancer therapy. Int J Radiation Oncology Biol Phys 10:787–800 Sapareto SA, Dewey WCL (1984) Thermal dose determination in cancer therapy. Int J Radiation Oncology Biol Phys 10:787–800
18.
Zurück zum Zitat Lepetit-Coiffe M, Quesson B, Seror O, Dumont E, Le Bail B, Moonen CTW, Trillaud H (2006) Real-time monitoring of radiofrequency ablation of rabbit liver by respiratory-gated quantitative temperature MRI. J Magn Reson Imaging 24:152–159PubMedCrossRef Lepetit-Coiffe M, Quesson B, Seror O, Dumont E, Le Bail B, Moonen CTW, Trillaud H (2006) Real-time monitoring of radiofrequency ablation of rabbit liver by respiratory-gated quantitative temperature MRI. J Magn Reson Imaging 24:152–159PubMedCrossRef
19.
Zurück zum Zitat Parker DL, Smith V, Sheldon P, Crooks LE, Fussell L (1983) Temperature distribution measurements in two-dimensional NMR imaging. Med Phys 10(3):321–325PubMedCrossRef Parker DL, Smith V, Sheldon P, Crooks LE, Fussell L (1983) Temperature distribution measurements in two-dimensional NMR imaging. Med Phys 10(3):321–325PubMedCrossRef
20.
Zurück zum Zitat Fried MP, Morrison PR, Hushek SG, Kernahan GA, Jolesz FA (1996) Dynamic T1-weighted magnetic resonance imaging of interstitial laser photocoagulation in the liver: observations on in vivo temperature sensitivity. Lasers Surg Med 18(4):410–419PubMedCrossRef Fried MP, Morrison PR, Hushek SG, Kernahan GA, Jolesz FA (1996) Dynamic T1-weighted magnetic resonance imaging of interstitial laser photocoagulation in the liver: observations on in vivo temperature sensitivity. Lasers Surg Med 18(4):410–419PubMedCrossRef
21.
Zurück zum Zitat Graham SJ, Bronskill MJ, Henkelman RM (1998) Time and temperature dependence of MR parameters during thermal coagulation of ex vivo rabbit muscle. Magn Reson Med 39(2):198–203PubMedCrossRef Graham SJ, Bronskill MJ, Henkelman RM (1998) Time and temperature dependence of MR parameters during thermal coagulation of ex vivo rabbit muscle. Magn Reson Med 39(2):198–203PubMedCrossRef
22.
Zurück zum Zitat Le Bihan D, Delannoy J, Levin RL (1989) Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia. Radiology 171(3):853–867PubMed Le Bihan D, Delannoy J, Levin RL (1989) Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia. Radiology 171(3):853–867PubMed
23.
Zurück zum Zitat De Poorter J, De Wagter C, De Deene Y, Thomsen C, Stahlberg F, Achten E (1995) Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: in vivo results in human muscle. Magn Reson Med 33(1):74–81PubMedCrossRef De Poorter J, De Wagter C, De Deene Y, Thomsen C, Stahlberg F, Achten E (1995) Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: in vivo results in human muscle. Magn Reson Med 33(1):74–81PubMedCrossRef
24.
Zurück zum Zitat Ishihara Y, Calderon A, Watanabe H, Okamoto K, Suzuki Y, Kuroda K et al (1995) A precise and fast temperature mapping using water proton chemical shift. Magn Reson Med 34(6):814–823PubMedCrossRef Ishihara Y, Calderon A, Watanabe H, Okamoto K, Suzuki Y, Kuroda K et al (1995) A precise and fast temperature mapping using water proton chemical shift. Magn Reson Med 34(6):814–823PubMedCrossRef
25.
Zurück zum Zitat Peters RD, Henkelman RM (2000) Proton-resonance frequency shift MR thermometry is affected by changes in the electrical conductivity of tissue. Magn Reson Med 43:62–71PubMedCrossRef Peters RD, Henkelman RM (2000) Proton-resonance frequency shift MR thermometry is affected by changes in the electrical conductivity of tissue. Magn Reson Med 43:62–71PubMedCrossRef
26.
Zurück zum Zitat Wlodarczyk W, Boroschewski R, Hentschel M, Wust P, Monich G, Felix R (1998) Three-dimensional monitoring of small temperature changes for therapeutic hyperthermia using MR. J Magn Reson Imaging 8(1):165–174PubMedCrossRef Wlodarczyk W, Boroschewski R, Hentschel M, Wust P, Monich G, Felix R (1998) Three-dimensional monitoring of small temperature changes for therapeutic hyperthermia using MR. J Magn Reson Imaging 8(1):165–174PubMedCrossRef
27.
Zurück zum Zitat Quesson B, de Zwart JA, Moonen CTW (2000) Magnetic resonance temperature imaging for guidance of thermotherapy. J Magn Reson Imaging 12(4):525–533PubMedCrossRef Quesson B, de Zwart JA, Moonen CTW (2000) Magnetic resonance temperature imaging for guidance of thermotherapy. J Magn Reson Imaging 12(4):525–533PubMedCrossRef
28.
Zurück zum Zitat Denis de Senneville B, Quesson B, Moonen CTW (2005) Magnetic resonance temperature imaging. Int J Hypertherm 21(6):515–531CrossRef Denis de Senneville B, Quesson B, Moonen CTW (2005) Magnetic resonance temperature imaging. Int J Hypertherm 21(6):515–531CrossRef
29.
Zurück zum Zitat de Zwart JA, Vimeux FC, Delalande C, Canioni P, Moonene CT (1999) Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation. Magn Reson Med 42(1):53–59PubMedCrossRef de Zwart JA, Vimeux FC, Delalande C, Canioni P, Moonene CT (1999) Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation. Magn Reson Med 42(1):53–59PubMedCrossRef
30.
Zurück zum Zitat McDannold N, Hynynen K, Wolf D, Wolf G, Jolesz F (1998) MRI evaluation of thermal ablation of tumors with focused ultrasound. J Magn Reson Ig 8:91–100CrossRef McDannold N, Hynynen K, Wolf D, Wolf G, Jolesz F (1998) MRI evaluation of thermal ablation of tumors with focused ultrasound. J Magn Reson Ig 8:91–100CrossRef
31.
Zurück zum Zitat Cline HE, Hynynen K, Hardy CJ, Watkins RD, Schenck JF, Jolesz FA (1994) MR temperature mapping of focused ultrasound surgery. Magn Reson Med 31:628–636PubMedCrossRef Cline HE, Hynynen K, Hardy CJ, Watkins RD, Schenck JF, Jolesz FA (1994) MR temperature mapping of focused ultrasound surgery. Magn Reson Med 31:628–636PubMedCrossRef
32.
Zurück zum Zitat Popat S, Lopez J, Chan S, Waters J, Cominos M, Rutter D, Hill ME (2006) Palliative treatments for patients with inoperable gastroesophageal cancers. Int J Palliat Nurs 12(7):306–317PubMed Popat S, Lopez J, Chan S, Waters J, Cominos M, Rutter D, Hill ME (2006) Palliative treatments for patients with inoperable gastroesophageal cancers. Int J Palliat Nurs 12(7):306–317PubMed
33.
Zurück zum Zitat Dahan L, Ries P, Laugier R, Seitz JF (2006) Palliative endoscopic treatments for esophageal cancers. Gastroenterol Clin Biol 30(2):253–261PubMedCrossRef Dahan L, Ries P, Laugier R, Seitz JF (2006) Palliative endoscopic treatments for esophageal cancers. Gastroenterol Clin Biol 30(2):253–261PubMedCrossRef
34.
Zurück zum Zitat Germain D, Chevallier P, Laurent A, Savart M, Wassef M, Saint-Jalmes H (2001) MR monitoring of laser-induced lesions of the liver in vivo in a low-field open magnet: temperature mapping and lesion size prediction. J Magn Reson Imaging 13(1):42–49PubMedCrossRef Germain D, Chevallier P, Laurent A, Savart M, Wassef M, Saint-Jalmes H (2001) MR monitoring of laser-induced lesions of the liver in vivo in a low-field open magnet: temperature mapping and lesion size prediction. J Magn Reson Imaging 13(1):42–49PubMedCrossRef
35.
Zurück zum Zitat Vogl TJ, Straub R, Zangos S, Mack MG, Eichler K (2004) MR-guided laser-induced thermotherapy (LITT) of liver tumours: experimental and clinical data. Int J Hyperthermia 20(7):713–724PubMedCrossRef Vogl TJ, Straub R, Zangos S, Mack MG, Eichler K (2004) MR-guided laser-induced thermotherapy (LITT) of liver tumours: experimental and clinical data. Int J Hyperthermia 20(7):713–724PubMedCrossRef
36.
Zurück zum Zitat Vogl TJ, Fieguth HG, Eichler K, Straub R, Lehnert T, Zangos S, Mack M (2004) Laser-induced thermotherapy of lung metastases and primary lung tumors. Radiologe 44(7):693–699PubMedCrossRef Vogl TJ, Fieguth HG, Eichler K, Straub R, Lehnert T, Zangos S, Mack M (2004) Laser-induced thermotherapy of lung metastases and primary lung tumors. Radiologe 44(7):693–699PubMedCrossRef
37.
Zurück zum Zitat Vogl TJ, Lehnert T, Wetter A, Mack MG, Wurster MG (2005) Interventional radiology in Carney triad. Eur Radiol 15(4):833–837PubMedCrossRef Vogl TJ, Lehnert T, Wetter A, Mack MG, Wurster MG (2005) Interventional radiology in Carney triad. Eur Radiol 15(4):833–837PubMedCrossRef
38.
Zurück zum Zitat Fiorella ML, Ross DA, White RI, Sabba C, Fiorella R (2004) Hereditary haemorrhagic telangiectasia: state of the art. Acta Otorhinolaryngol Ital 24(6):330–336PubMed Fiorella ML, Ross DA, White RI, Sabba C, Fiorella R (2004) Hereditary haemorrhagic telangiectasia: state of the art. Acta Otorhinolaryngol Ital 24(6):330–336PubMed
39.
Zurück zum Zitat Maataoui A, Qian J, Mack MG, Straub R, Oppermann E, Khan MF, Knappe V, Vogl TJ (2005) Laser-induced Interstitial thermotherapy (LITT) in hepatic metastases of various sizes in an animal model. Rofo 177(3):405–410PubMed Maataoui A, Qian J, Mack MG, Straub R, Oppermann E, Khan MF, Knappe V, Vogl TJ (2005) Laser-induced Interstitial thermotherapy (LITT) in hepatic metastases of various sizes in an animal model. Rofo 177(3):405–410PubMed
40.
Zurück zum Zitat Eyrich GK, Bruder E, Hilfiker P, Dubno B, Quick HH, Patak MA, Gratz KW, Sailer HF (2000) Temperature mapping of magnetic resonance-guided laser interstitial thermal therapy (LITT) in lymphangiomas of the head and neck. Lasers Surg Med 26(5):467–476PubMedCrossRef Eyrich GK, Bruder E, Hilfiker P, Dubno B, Quick HH, Patak MA, Gratz KW, Sailer HF (2000) Temperature mapping of magnetic resonance-guided laser interstitial thermal therapy (LITT) in lymphangiomas of the head and neck. Lasers Surg Med 26(5):467–476PubMedCrossRef
41.
Zurück zum Zitat Atsumi H, Matsumae M (2005) Laser interstitial thermo therapy (LITT) for brain tumors. Nippon Rinsho 63(Suppl 9):495–498PubMed Atsumi H, Matsumae M (2005) Laser interstitial thermo therapy (LITT) for brain tumors. Nippon Rinsho 63(Suppl 9):495–498PubMed
42.
Zurück zum Zitat Peters RD, Chan E, Trachtenberg J, Jothy S, Kapusta L, Kucharczyk W et al (2000) Magnetic resonance thermometry for predicting thermal damage: an application of interstitial laser coagulation in an in vivo canine prostate model. Magn Reson Med 44(6):873–883PubMedCrossRef Peters RD, Chan E, Trachtenberg J, Jothy S, Kapusta L, Kucharczyk W et al (2000) Magnetic resonance thermometry for predicting thermal damage: an application of interstitial laser coagulation in an in vivo canine prostate model. Magn Reson Med 44(6):873–883PubMedCrossRef
43.
Zurück zum Zitat Vigen KK, Daniel BL, Pauly JM, Butts K (2003) Triggered, navigated, multi-baseline method for proton resonance frequency temperature mapping with respiratory motion. Magn Reson Med 50(5):1003–1010PubMedCrossRef Vigen KK, Daniel BL, Pauly JM, Butts K (2003) Triggered, navigated, multi-baseline method for proton resonance frequency temperature mapping with respiratory motion. Magn Reson Med 50(5):1003–1010PubMedCrossRef
44.
Zurück zum Zitat McGahan JP, Browning PD, Brock JM, Teslik H (1990) Hepatic ablation using radiofrequency electrocautery. Invest Radiol 25:267–270PubMedCrossRef McGahan JP, Browning PD, Brock JM, Teslik H (1990) Hepatic ablation using radiofrequency electrocautery. Invest Radiol 25:267–270PubMedCrossRef
45.
Zurück zum Zitat Rossi S, Fornari F, Pathies C, Buscarini L (1990) Thermal lesions induced by 480 KHz localized current field in guinea pig and pig liver. Tumori 76:54–57PubMed Rossi S, Fornari F, Pathies C, Buscarini L (1990) Thermal lesions induced by 480 KHz localized current field in guinea pig and pig liver. Tumori 76:54–57PubMed
46.
Zurück zum Zitat Nour SG (2004) Standardization of terms and reporting criteria for imageguided tumor ablation. Radiology 232:626–627; author reply 627PubMedCrossRef Nour SG (2004) Standardization of terms and reporting criteria for imageguided tumor ablation. Radiology 232:626–627; author reply 627PubMedCrossRef
47.
Zurück zum Zitat Chen MH, Yang W, Yan K et al (2004) Large liver tumors: protocol for radiofrequency ablation and its clinical application in 110 patients-mathematic model, overlapping mode, and electrode placement process. Radiology 232:260–271PubMedCrossRef Chen MH, Yang W, Yan K et al (2004) Large liver tumors: protocol for radiofrequency ablation and its clinical application in 110 patients-mathematic model, overlapping mode, and electrode placement process. Radiology 232:260–271PubMedCrossRef
48.
Zurück zum Zitat Solbiati L, Ierace T, Tonolini M, Cova L (2004) Guidance and monitoring of radiofrequency liver tumor ablation with contrast-enhanced ultrasound. Eur Journ Radiol 51(Suppl):S19–S23CrossRef Solbiati L, Ierace T, Tonolini M, Cova L (2004) Guidance and monitoring of radiofrequency liver tumor ablation with contrast-enhanced ultrasound. Eur Journ Radiol 51(Suppl):S19–S23CrossRef
49.
Zurück zum Zitat Solbiati L, Tonolini M, Cova L (2004) Monitoring RF ablation. Eur Radiol 14(Suppl 8):P34–P42PubMed Solbiati L, Tonolini M, Cova L (2004) Monitoring RF ablation. Eur Radiol 14(Suppl 8):P34–P42PubMed
50.
Zurück zum Zitat Gellermann J, Wlodarczyk W, Feussner A, Fahling H, Nadobny J, Hildebrandt B, Felix R, Wust P (2005) Methods and potentials of magnetic resonance imaging for monitoring radiofrequency hyperthermia in a hybrid system. Int J Hyperthermia 21(6):497–513PubMedCrossRef Gellermann J, Wlodarczyk W, Feussner A, Fahling H, Nadobny J, Hildebrandt B, Felix R, Wust P (2005) Methods and potentials of magnetic resonance imaging for monitoring radiofrequency hyperthermia in a hybrid system. Int J Hyperthermia 21(6):497–513PubMedCrossRef
51.
Zurück zum Zitat Lepetit-Coiffe M, Quesson B, Seror O, Dumont E, Le Bail B, Moonen CTW, Trillaud H (2006) Real-time monitoring of radiofrequency ablation of rabbit liver by respiratory-gated quantitative temperature MRI. J Magn Reson Imaging 24(1):152–159PubMedCrossRef Lepetit-Coiffe M, Quesson B, Seror O, Dumont E, Le Bail B, Moonen CTW, Trillaud H (2006) Real-time monitoring of radiofrequency ablation of rabbit liver by respiratory-gated quantitative temperature MRI. J Magn Reson Imaging 24(1):152–159PubMedCrossRef
52.
Zurück zum Zitat Rhim H, Goldberg SN, Dodd GD 3rd et al (2001) Essential techniques for successful radio-frequency thermal ablation of malignant hepatic tumors. Radiographics 21(spec no):S17–S35; discussion S36–S19PubMed Rhim H, Goldberg SN, Dodd GD 3rd et al (2001) Essential techniques for successful radio-frequency thermal ablation of malignant hepatic tumors. Radiographics 21(spec no):S17–S35; discussion S36–S19PubMed
53.
Zurück zum Zitat Aube C, Schmidt D, Brieger J et al (2004) Magnetic resonance imaging characteristics of six radiofrequency electrodes in a phantom study. J Vasc Interv Radiol 15:385–392PubMed Aube C, Schmidt D, Brieger J et al (2004) Magnetic resonance imaging characteristics of six radiofrequency electrodes in a phantom study. J Vasc Interv Radiol 15:385–392PubMed
54.
Zurück zum Zitat Demura K, Morikawa S, Murakami K, Sato K, Shiomi H, Naka S, Kurumi Y, Inubushi T, Tani T (2006) An easy-to-use microwave hyperthermia system combined with spatially resolved MR temperature maps: phantom and animal studies. J Surg Res 135(1):179–186PubMedCrossRef Demura K, Morikawa S, Murakami K, Sato K, Shiomi H, Naka S, Kurumi Y, Inubushi T, Tani T (2006) An easy-to-use microwave hyperthermia system combined with spatially resolved MR temperature maps: phantom and animal studies. J Surg Res 135(1):179–186PubMedCrossRef
55.
Zurück zum Zitat Sato K, Morikawa S, Inubushi T, Kurumi Y, Naka S, Haque HA, Demura K, Tani T (2005) Alternate biplanar MR navigation for microwave ablation of liver tumors. Magn Reson Med Sci 4(2):89–94PubMedCrossRef Sato K, Morikawa S, Inubushi T, Kurumi Y, Naka S, Haque HA, Demura K, Tani T (2005) Alternate biplanar MR navigation for microwave ablation of liver tumors. Magn Reson Med Sci 4(2):89–94PubMedCrossRef
56.
Zurück zum Zitat Lynn JG, Putman TJ (1944) Histological and cerebral lesions produced by focused ultrasound. Am J Pathol 20:637–649PubMed Lynn JG, Putman TJ (1944) Histological and cerebral lesions produced by focused ultrasound. Am J Pathol 20:637–649PubMed
57.
Zurück zum Zitat Cline HE, Schenck JF, Hynynen K, Watkins RD, Souza SP, Jolesz FA (1992) MR-guided focused ultrasound surgery. J Comput Assist Tomogr 16(6):956–965PubMedCrossRef Cline HE, Schenck JF, Hynynen K, Watkins RD, Souza SP, Jolesz FA (1992) MR-guided focused ultrasound surgery. J Comput Assist Tomogr 16(6):956–965PubMedCrossRef
58.
Zurück zum Zitat Pernot M, Aubry JF, Tanter M, Thomas JL, Fink M (2003) High power transcranial beam steering for ultrasonic brain therapy. Phys Med Biol 48(16):2577–2589PubMedCrossRef Pernot M, Aubry JF, Tanter M, Thomas JL, Fink M (2003) High power transcranial beam steering for ultrasonic brain therapy. Phys Med Biol 48(16):2577–2589PubMedCrossRef
59.
Zurück zum Zitat Hynynen K, McDannold N, Clement G, Jolesz FA, Zadicario E, Killiany R, Moore T, Rosen D (2006) Pre-clinical testing of a phased array ultrasound system for MRI-guided noninvasive surgery of the brain-a primate study. Eur J Radiol 59(2):149–156PubMedCrossRef Hynynen K, McDannold N, Clement G, Jolesz FA, Zadicario E, Killiany R, Moore T, Rosen D (2006) Pre-clinical testing of a phased array ultrasound system for MRI-guided noninvasive surgery of the brain-a primate study. Eur J Radiol 59(2):149–156PubMedCrossRef
60.
Zurück zum Zitat Ram Z, Cohen ZR, Harnof S, Tal S, Faibel M, Nass D, Maier SE, Hadani M, Mardor Y (2006) Magnetic resonance imaging-guided, high-intensity focused ultrasound for brain tumor therapy. Neurosurgery 59(5):949–955PubMed Ram Z, Cohen ZR, Harnof S, Tal S, Faibel M, Nass D, Maier SE, Hadani M, Mardor Y (2006) Magnetic resonance imaging-guided, high-intensity focused ultrasound for brain tumor therapy. Neurosurgery 59(5):949–955PubMed
61.
Zurück zum Zitat Denis de Senneville B, Mougenot C, Moonen CTW (2007) Real time adaptive methods for treatment of mobile organs by MRI controlled high intensity focused ultrasound. Magn Reson Med 57(2):319–330CrossRef Denis de Senneville B, Mougenot C, Moonen CTW (2007) Real time adaptive methods for treatment of mobile organs by MRI controlled high intensity focused ultrasound. Magn Reson Med 57(2):319–330CrossRef
62.
Zurück zum Zitat Bennett WR (1962) Electrical noise. McGraw Hill, New-York Bennett WR (1962) Electrical noise. McGraw Hill, New-York
63.
Zurück zum Zitat Gudbjartsson H, Patz S (1995) The rician distribution of noisy MRI data. Magn Reson Med 34:910–914PubMedCrossRef Gudbjartsson H, Patz S (1995) The rician distribution of noisy MRI data. Magn Reson Med 34:910–914PubMedCrossRef
64.
Zurück zum Zitat Sijbers J, den Dekker AJ (2004) Maximum likelihood estimation of signal amplitude and noise variance from MR data. Magn Reson Med 51:589–594CrossRef Sijbers J, den Dekker AJ (2004) Maximum likelihood estimation of signal amplitude and noise variance from MR data. Magn Reson Med 51:589–594CrossRef
65.
Zurück zum Zitat De Poorter J, De Wagter C, De Deene Y, Thomson C, Stahlberg F, Achten E (1994) The proton resonance frequency shift method compared with molecular diffusion for quantitative measurement of two dimensional time dependent temperature distribution in phantom. J Magn Reson 103:234–241CrossRef De Poorter J, De Wagter C, De Deene Y, Thomson C, Stahlberg F, Achten E (1994) The proton resonance frequency shift method compared with molecular diffusion for quantitative measurement of two dimensional time dependent temperature distribution in phantom. J Magn Reson 103:234–241CrossRef
66.
Zurück zum Zitat Young IR, Hajnal JV, Roberts IG, Ling JX, Hill-Cottingham RJ, Oatridge A et al (1996) An evaluation of the effects of susceptibility changes on the water chemical shift method of temperature measurement in human peripheral muscle. Magn Reson Med 36(3):366–374PubMedCrossRef Young IR, Hajnal JV, Roberts IG, Ling JX, Hill-Cottingham RJ, Oatridge A et al (1996) An evaluation of the effects of susceptibility changes on the water chemical shift method of temperature measurement in human peripheral muscle. Magn Reson Med 36(3):366–374PubMedCrossRef
67.
Zurück zum Zitat Mougenot C, Salomir R, Palussière J, Grenier N, Moonen CTW (2004) Automatic spatial and temporal temperature control for MR-guided focused ultrasound using fast 3D MR thermometry and multispiral trajectory of the focal point. Magn Reson Med 52:1005–1015PubMedCrossRef Mougenot C, Salomir R, Palussière J, Grenier N, Moonen CTW (2004) Automatic spatial and temporal temperature control for MR-guided focused ultrasound using fast 3D MR thermometry and multispiral trajectory of the focal point. Magn Reson Med 52:1005–1015PubMedCrossRef
68.
Zurück zum Zitat Kennedy JE, ter Haar GR, Cranston D (2003) High intensity focused ultrasound: surgery of the future? Br J Radiol 76(909):590–599PubMedCrossRef Kennedy JE, ter Haar GR, Cranston D (2003) High intensity focused ultrasound: surgery of the future? Br J Radiol 76(909):590–599PubMedCrossRef
69.
Zurück zum Zitat Scheffler K (2004) Fast frequency mapping with balanced SSFP: theory and application to proton-resonance frequency shift thermometry. Magn Reson Med 51(6):1205–1211PubMedCrossRef Scheffler K (2004) Fast frequency mapping with balanced SSFP: theory and application to proton-resonance frequency shift thermometry. Magn Reson Med 51(6):1205–1211PubMedCrossRef
70.
Zurück zum Zitat Riederer SJ (1996) Recent technical advances in MR imaging of the abdomen. J Magn Reson Imaging 6:822–832PubMedCrossRef Riederer SJ (1996) Recent technical advances in MR imaging of the abdomen. J Magn Reson Imaging 6:822–832PubMedCrossRef
Metadaten
Titel
MR thermometry for monitoring tumor ablation
verfasst von
Baudouin Denis de Senneville
Charles Mougenot
Bruno Quesson
Iulius Dragonu
Nicolas Grenier
Chrit T. W. Moonen
Publikationsdatum
01.09.2007
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 9/2007
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-007-0646-6

Weitere Artikel der Ausgabe 9/2007

European Radiology 9/2007 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.