Skip to main content
Erschienen in: European Radiology 6/2008

01.06.2008 | Chest

CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

verfasst von: Christian Billich, Rainer Muche, Gerhard Brenner, Stefan A. Schmidt, Stefan Krüger, Hans-Jürgen Brambs, Sandra Pauls

Erschienen in: European Radiology | Ausgabe 6/2008

Einloggen, um Zugang zu erhalten

Abstract

This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n = 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P = 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax.
Literatur
1.
Zurück zum Zitat Westcott JL (1988) Percutaneous transthoracic needle biopsy. Radiology 169:593–601PubMed Westcott JL (1988) Percutaneous transthoracic needle biopsy. Radiology 169:593–601PubMed
2.
Zurück zum Zitat van Sonnenberg E, Casola G, Ho M, Neff CC, Varney RR, Wittich GR, Christensen R, Friedman PJ (1988) Difficult thoracic lesions: CT-guided biopsy experience in 150 cases. Radiology 167:457–461 van Sonnenberg E, Casola G, Ho M, Neff CC, Varney RR, Wittich GR, Christensen R, Friedman PJ (1988) Difficult thoracic lesions: CT-guided biopsy experience in 150 cases. Radiology 167:457–461
3.
Zurück zum Zitat Klein JS, Salomon G, Stewart EA (1996) Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle, results in 122 patients. Radiology 198:715–720PubMed Klein JS, Salomon G, Stewart EA (1996) Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle, results in 122 patients. Radiology 198:715–720PubMed
4.
Zurück zum Zitat Laurent F, Michel P, Latrabe V, Tunon de Lara M, Marthan R (1999) Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors. AJR 172:1049–1053PubMed Laurent F, Michel P, Latrabe V, Tunon de Lara M, Marthan R (1999) Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors. AJR 172:1049–1053PubMed
5.
Zurück zum Zitat Ko JP, Shepard J-AO, Drucker EA, Aquino SL, Sharma A, Sabloff B, Halpern E, McLoud TC (2001) Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors? Radiology 218:491–496PubMed Ko JP, Shepard J-AO, Drucker EA, Aquino SL, Sharma A, Sabloff B, Halpern E, McLoud TC (2001) Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors? Radiology 218:491–496PubMed
6.
Zurück zum Zitat Anderson JM, Murchison J, Patel D (2003) CT-guided lung biopsy: factors influencing diagnostic yield and complication rate. Clin Radiol 58:791–797PubMedCrossRef Anderson JM, Murchison J, Patel D (2003) CT-guided lung biopsy: factors influencing diagnostic yield and complication rate. Clin Radiol 58:791–797PubMedCrossRef
7.
Zurück zum Zitat Choi C-M, UM S-W, Yoo C-G, Kim YW, Han SK, Shim Y-S, Lee C-T (2004) Incidence and risk factors of delayed pneumothorax after transthoracic needle biopsy of the lung. Chest 126:1516–1521PubMedCrossRef Choi C-M, UM S-W, Yoo C-G, Kim YW, Han SK, Shim Y-S, Lee C-T (2004) Incidence and risk factors of delayed pneumothorax after transthoracic needle biopsy of the lung. Chest 126:1516–1521PubMedCrossRef
8.
Zurück zum Zitat Yeow KM, Su IH, Pan KT, Tsay P-K, Lui K-W, Cheung Y-C, Chou ASB (2004) Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest 126:748–754PubMedCrossRef Yeow KM, Su IH, Pan KT, Tsay P-K, Lui K-W, Cheung Y-C, Chou ASB (2004) Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest 126:748–754PubMedCrossRef
9.
Zurück zum Zitat Bourgouin PM, Shepard JA, McLoud TC, Spizarny DL, Dedrick CG (1988) Transthoracic needle aspiration biopsy: evaluation of the blood patch technique. Radiology 166:93–97PubMed Bourgouin PM, Shepard JA, McLoud TC, Spizarny DL, Dedrick CG (1988) Transthoracic needle aspiration biopsy: evaluation of the blood patch technique. Radiology 166:93–97PubMed
10.
Zurück zum Zitat Surprenant EL (1988) Transthoracic needle aspiration biopsy: evaluation of the blood patch technique. Radiology 168:285PubMed Surprenant EL (1988) Transthoracic needle aspiration biopsy: evaluation of the blood patch technique. Radiology 168:285PubMed
11.
Zurück zum Zitat Herman SJ, Weisbrod GL (1990) Usefulness of blood patch technique after transthoracic needle aspiration biopsy. Radiology 176:395–397PubMed Herman SJ, Weisbrod GL (1990) Usefulness of blood patch technique after transthoracic needle aspiration biopsy. Radiology 176:395–397PubMed
12.
Zurück zum Zitat Lang EK, Ghavami R, Schreiner VC, Archibald S, Ramirez J (2000) Autologous blood clot seal to prevent pneumothorax at CT-guided lung biopsy. Radiology 216:93–96PubMed Lang EK, Ghavami R, Schreiner VC, Archibald S, Ramirez J (2000) Autologous blood clot seal to prevent pneumothorax at CT-guided lung biopsy. Radiology 216:93–96PubMed
13.
Zurück zum Zitat Moore EH, Shelton DK, Wisner ER, Richardson ML, Bishop DM, Brock JM (1995) Needle aspiration lung biopsy: reevaluation of the blood patch technique in an equine model. Radiology 196:183–186PubMed Moore EH, Shelton DK, Wisner ER, Richardson ML, Bishop DM, Brock JM (1995) Needle aspiration lung biopsy: reevaluation of the blood patch technique in an equine model. Radiology 196:183–186PubMed
14.
Zurück zum Zitat Engeler CE, Hunter DW, Castaneda-Zuniga W, Tashijian JH, Yedlicka JW, Amplatz K (1992) Pneumothorax after lung biopsy: prevention with transpleural placement of compressed collagen foam plugs. Radiology 184:787–789PubMed Engeler CE, Hunter DW, Castaneda-Zuniga W, Tashijian JH, Yedlicka JW, Amplatz K (1992) Pneumothorax after lung biopsy: prevention with transpleural placement of compressed collagen foam plugs. Radiology 184:787–789PubMed
15.
Zurück zum Zitat Petsas T, Siamblis D, Giannakenas C, Tepetes K, Dougenis D, Spiropoulos K, Fezoulis I, Dimopoulos I (1995) Fibrin glue for sealing the needle tract after percutaneous lung biopsy using a coaxial system: part II – clinical study. Cardiovasc Intervent Radiol 18:378–382PubMedCrossRef Petsas T, Siamblis D, Giannakenas C, Tepetes K, Dougenis D, Spiropoulos K, Fezoulis I, Dimopoulos I (1995) Fibrin glue for sealing the needle tract after percutaneous lung biopsy using a coaxial system: part II – clinical study. Cardiovasc Intervent Radiol 18:378–382PubMedCrossRef
16.
Zurück zum Zitat Skupin A, Gomez F, Husain M, Skupin C, Bigman O (1987) Complications of transthoracic needle biopsy decreased with isobutyl 2-cyanoacrylate: a pilot study. Ann Thorac Surg 43:406–408PubMedCrossRef Skupin A, Gomez F, Husain M, Skupin C, Bigman O (1987) Complications of transthoracic needle biopsy decreased with isobutyl 2-cyanoacrylate: a pilot study. Ann Thorac Surg 43:406–408PubMedCrossRef
17.
Zurück zum Zitat Haaga JR, Alfidi RJ (1976) Precise biopsy localisation by computer tomography. Radiology 118:603–607PubMed Haaga JR, Alfidi RJ (1976) Precise biopsy localisation by computer tomography. Radiology 118:603–607PubMed
18.
Zurück zum Zitat Brown KT, Brody LA, Getrajdman GI, Napp TE (1997) Outpatient treatment of iatrogenic pneumothorax after needle biopsy. Radiology 205:249–253PubMed Brown KT, Brody LA, Getrajdman GI, Napp TE (1997) Outpatient treatment of iatrogenic pneumothorax after needle biopsy. Radiology 205:249–253PubMed
19.
Zurück zum Zitat Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD (2003) CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 229:475–481PubMedCrossRef Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD (2003) CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 229:475–481PubMedCrossRef
20.
Zurück zum Zitat Gupta S, Krishnamurthy S, Broemeling LD, Morello FA, Wallace MJ, Ahrar K, Madoff DC, Murthy R, Hicks ME (2005) Small (≤2 cm) subpleural pulmonary lesions: short versus long-needle-path CT-guided biopsy-comparison of diagnostic yields and complications. Radiology 234:631–637PubMedCrossRef Gupta S, Krishnamurthy S, Broemeling LD, Morello FA, Wallace MJ, Ahrar K, Madoff DC, Murthy R, Hicks ME (2005) Small (≤2 cm) subpleural pulmonary lesions: short versus long-needle-path CT-guided biopsy-comparison of diagnostic yields and complications. Radiology 234:631–637PubMedCrossRef
21.
Zurück zum Zitat Moore EH (1998) Technical aspects of needle aspiration lung biopsy: a personal perspective. Radiology 208:303–318PubMed Moore EH (1998) Technical aspects of needle aspiration lung biopsy: a personal perspective. Radiology 208:303–318PubMed
22.
Zurück zum Zitat Swischuk JL, Castaneda F, Patel JC, Li R, Fraser KW, Brady TM, Bertino RE (1998) Percutaneous transthoracic needle biopsy of the lung: review of 612 lesions. J Vasc Interv Radiol 9:347–352PubMedCrossRef Swischuk JL, Castaneda F, Patel JC, Li R, Fraser KW, Brady TM, Bertino RE (1998) Percutaneous transthoracic needle biopsy of the lung: review of 612 lesions. J Vasc Interv Radiol 9:347–352PubMedCrossRef
Metadaten
Titel
CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track
verfasst von
Christian Billich
Rainer Muche
Gerhard Brenner
Stefan A. Schmidt
Stefan Krüger
Hans-Jürgen Brambs
Sandra Pauls
Publikationsdatum
01.06.2008
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 6/2008
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-0872-6

Weitere Artikel der Ausgabe 6/2008

European Radiology 6/2008 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.