Skip to main content
Erschienen in: European Radiology 4/2013

01.04.2013 | Urogenital

Uterine cervical carcinoma: a comparison of two- and three-dimensional T2-weighted turbo spin-echo MR imaging at 3.0 T for image quality and local-regional staging

verfasst von: Y. R. Shin, S. E. Rha, B. G. Choi, S. N. Oh, M. Y. Park, J. Y. Byun

Erschienen in: European Radiology | Ausgabe 4/2013

Einloggen, um Zugang zu erhalten

Abstract

Objective

To compare three-dimensional (3D) T2-weighted turbo spin-echo (TSE) with multiplanar two-dimensional (2D) T2-weighted TSE for the evaluation of invasive cervical carcinoma.

Methods

Seventy-five patients with cervical carcinoma underwent MRI of the pelvis at 3.0 T, using both 5-mm-thick multiplanar 2D (total acquisition time = 12 min 25 s) and 1-mm-thick coronal 3D T2-weighted TSE sequences (7 min 20 s). Quantitative analysis of signal-to-noise ratio (SNR) and qualitative analysis of image quality were performed. Local-regional staging was performed in 45 patients who underwent radical hysterectomy.

Results

The estimated SNR of cervical carcinoma and the relative tumour contrast were significantly higher on 3D imaging (P < 0.0001). Tumour conspicuity was better with the 3D sequence, but the sharpness of tumour margin was better with the 2D sequence. No significant difference in overall image quality was noted between the two sequences (P = 0.38). There were no significant differences in terms of the diagnostic accuracy, sensitivity, and specificity of parametrial invasion, vaginal invasion, and lymph node metastases.

Conclusion

Multiplanar reconstruction 3D T2-weighted imaging is largely equivalent to 2D T2-weighted imaging for overall image quality and staging accuracy of cervical carcinoma with a shorter MR data acquisition, but has limitations with regard to the sharpness of the tumour margin.

Key Points

3D T2-weighted MR sequence is equivalent to 2D for cervical carcinoma staging.
Coronal 3D acquisitions can reduce the examination time.
SNR and relative tumour conspicuity were significantly higher on 3D sequences.
Reformatted 3D T2-weighted imaging had limitations in sharpness of tumour margin.
Literatur
1.
Zurück zum Zitat Engin G (2006) Cervical cancer: MR imaging findings before, during, and after radiation therapy. Eur Radiol 16:313–324PubMedCrossRef Engin G (2006) Cervical cancer: MR imaging findings before, during, and after radiation therapy. Eur Radiol 16:313–324PubMedCrossRef
2.
Zurück zum Zitat Merkle EM, Dale BM, Paulson EK (2006) Abdominal MR imaging at 3T. Magn Reson Imaging Clin N Am 14:17–26PubMedCrossRef Merkle EM, Dale BM, Paulson EK (2006) Abdominal MR imaging at 3T. Magn Reson Imaging Clin N Am 14:17–26PubMedCrossRef
4.
Zurück zum Zitat Uematsu H, Dougherty L, Takahashi M et al (2003) Abdominal imaging at 4 T MR system: a preliminary result. Eur J Radiol 47:161–163PubMedCrossRef Uematsu H, Dougherty L, Takahashi M et al (2003) Abdominal imaging at 4 T MR system: a preliminary result. Eur J Radiol 47:161–163PubMedCrossRef
5.
Zurück zum Zitat Uematsu H, Takahashi M, Dougherty L, Hatabu H (2004) High field body MR imaging: preliminary experiences. Clin Imaging 28:159–162PubMedCrossRef Uematsu H, Takahashi M, Dougherty L, Hatabu H (2004) High field body MR imaging: preliminary experiences. Clin Imaging 28:159–162PubMedCrossRef
6.
Zurück zum Zitat Martin DR, Friel HT, Danrad R, De Becker J, Hussain SM (2005) Approach to abdominal imaging at 1.5 Tesla and optimization at 3 Tesla. Magn Reson Imaging Clin N Am 13:241–254, v-viPubMedCrossRef Martin DR, Friel HT, Danrad R, De Becker J, Hussain SM (2005) Approach to abdominal imaging at 1.5 Tesla and optimization at 3 Tesla. Magn Reson Imaging Clin N Am 13:241–254, v-viPubMedCrossRef
7.
Zurück zum Zitat Pruessmann KP (2004) Parallel imaging at high field strength: synergies and joint potential. Top Magn Reson Imaging 15:237–244PubMedCrossRef Pruessmann KP (2004) Parallel imaging at high field strength: synergies and joint potential. Top Magn Reson Imaging 15:237–244PubMedCrossRef
8.
Zurück zum Zitat Lichy MP, Wietek BM, Mugler JP 3rd et al (2005) Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: initial clinical experiences. Invest Radiol 40:754–760PubMedCrossRef Lichy MP, Wietek BM, Mugler JP 3rd et al (2005) Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: initial clinical experiences. Invest Radiol 40:754–760PubMedCrossRef
9.
Zurück zum Zitat Meindl T, Wirth S, Weckbach S, Dietrich O, Reiser M, Schoenberg SO (2009) Magnetic resonance imaging of the cervical spine: comparison of 2D T2-weighted turbo spin echo, 2D T2*weighted gradient-recalled echo and 3D T2-weighted variable flip-angle turbo spin echo sequences. Eur Radiol 19:713–721PubMedCrossRef Meindl T, Wirth S, Weckbach S, Dietrich O, Reiser M, Schoenberg SO (2009) Magnetic resonance imaging of the cervical spine: comparison of 2D T2-weighted turbo spin echo, 2D T2*weighted gradient-recalled echo and 3D T2-weighted variable flip-angle turbo spin echo sequences. Eur Radiol 19:713–721PubMedCrossRef
10.
Zurück zum Zitat Rosenkrantz AB, Neil J, Kong X et al (2010) Prostate cancer: comparison of 3D T2-weighted with conventional 2D T2-weighted imaging for image quality and tumor detection. AJR Am J Roentgenol 194:446–452PubMedCrossRef Rosenkrantz AB, Neil J, Kong X et al (2010) Prostate cancer: comparison of 3D T2-weighted with conventional 2D T2-weighted imaging for image quality and tumor detection. AJR Am J Roentgenol 194:446–452PubMedCrossRef
11.
Zurück zum Zitat Rosenkrantz AB, Patel JM, Babb JS, Storey P, Hecht EM (2010) Liver MRI at 3 T using a respiratory-triggered time-efficient 3D T2-weighted technique: impact on artifacts and image quality. AJR Am J Roentgenol 194:634–641PubMedCrossRef Rosenkrantz AB, Patel JM, Babb JS, Storey P, Hecht EM (2010) Liver MRI at 3 T using a respiratory-triggered time-efficient 3D T2-weighted technique: impact on artifacts and image quality. AJR Am J Roentgenol 194:634–641PubMedCrossRef
12.
Zurück zum Zitat Ristow O, Steinbach L, Sabo G et al (2009) Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee–image quality and diagnostic performance. Eur Radiol 19:1263–1272PubMedCrossRef Ristow O, Steinbach L, Sabo G et al (2009) Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee–image quality and diagnostic performance. Eur Radiol 19:1263–1272PubMedCrossRef
13.
Zurück zum Zitat Futterer JJ, Yakar D, Strijk SP, Barentsz JO (2008) Preoperative 3T MR imaging of rectal cancer: local staging accuracy using a two-dimensional and three-dimensional T2-weighted turbo spin echo sequence. Eur J Radiol 65:66–71PubMedCrossRef Futterer JJ, Yakar D, Strijk SP, Barentsz JO (2008) Preoperative 3T MR imaging of rectal cancer: local staging accuracy using a two-dimensional and three-dimensional T2-weighted turbo spin echo sequence. Eur J Radiol 65:66–71PubMedCrossRef
14.
Zurück zum Zitat Kim H, Lim JS, Choi JY et al (2010) Rectal cancer: comparison of accuracy of local-regional staging with two- and three-dimensional preoperative 3.0T MR imaging. Radiology 254:485–492PubMedCrossRef Kim H, Lim JS, Choi JY et al (2010) Rectal cancer: comparison of accuracy of local-regional staging with two- and three-dimensional preoperative 3.0T MR imaging. Radiology 254:485–492PubMedCrossRef
15.
Zurück zum Zitat Agrawal G, Riherd JM, Busse RF, Hinshaw JL, Sadowski EA (2009) Evaluation of uterine anomalies: 3D FRFSE cube versus standard 2D FRFSE. AJR Am J Roentgenol 193:W558–W562PubMedCrossRef Agrawal G, Riherd JM, Busse RF, Hinshaw JL, Sadowski EA (2009) Evaluation of uterine anomalies: 3D FRFSE cube versus standard 2D FRFSE. AJR Am J Roentgenol 193:W558–W562PubMedCrossRef
16.
Zurück zum Zitat Hecht EM, Yitta S, Lim RP et al (2011) Preliminary clinical experience at 3 T with a 3D T2-weighted sequence compared with multiplanar 2D for evaluation of the female pelvis. AJR Am J Roentgenol 197:W346–W352PubMedCrossRef Hecht EM, Yitta S, Lim RP et al (2011) Preliminary clinical experience at 3 T with a 3D T2-weighted sequence compared with multiplanar 2D for evaluation of the female pelvis. AJR Am J Roentgenol 197:W346–W352PubMedCrossRef
17.
Zurück zum Zitat Proscia N, Jaffe TA, Neville AM, Wang CL, Dale BM, Merkle EM (2010) MRI of the pelvis in women: 3D versus 2D T2-weighted technique. AJR Am J Roentgenol 195:254–259PubMedCrossRef Proscia N, Jaffe TA, Neville AM, Wang CL, Dale BM, Merkle EM (2010) MRI of the pelvis in women: 3D versus 2D T2-weighted technique. AJR Am J Roentgenol 195:254–259PubMedCrossRef
18.
Zurück zum Zitat Hori M, Kim T, Onishi H et al (2011) Uterine tumors: comparison of 3D versus 2D T2-weighted turbo spin-echo MR imaging at 3.0 T–initial experience. Radiology 258:154–163PubMedCrossRef Hori M, Kim T, Onishi H et al (2011) Uterine tumors: comparison of 3D versus 2D T2-weighted turbo spin-echo MR imaging at 3.0 T–initial experience. Radiology 258:154–163PubMedCrossRef
19.
Zurück zum Zitat Pecorelli S (2009) Revised FIGO staging for carcinoma of the vulva, cervix, and endometrium. Int J Gynaecol Obstet 105:103–104PubMedCrossRef Pecorelli S (2009) Revised FIGO staging for carcinoma of the vulva, cervix, and endometrium. Int J Gynaecol Obstet 105:103–104PubMedCrossRef
20.
Zurück zum Zitat Hricak H, Gatsonis C, Coakley FV et al (2007) Early invasive cervical cancer: CT and MR imaging in preoperative evaluation - ACRIN/GOG comparative study of diagnostic performance and interobserver variability. Radiology 245:491–498PubMedCrossRef Hricak H, Gatsonis C, Coakley FV et al (2007) Early invasive cervical cancer: CT and MR imaging in preoperative evaluation - ACRIN/GOG comparative study of diagnostic performance and interobserver variability. Radiology 245:491–498PubMedCrossRef
21.
Zurück zum Zitat Sodickson A, Mortele KJ, Barish MA, Zou KH, Thibodeau S, Tempany CM (2006) Three-dimensional fast-recovery fast spin-echo MRCP: comparison with two-dimensional single-shot fast spin-echo techniques. Radiology 238:549–559PubMedCrossRef Sodickson A, Mortele KJ, Barish MA, Zou KH, Thibodeau S, Tempany CM (2006) Three-dimensional fast-recovery fast spin-echo MRCP: comparison with two-dimensional single-shot fast spin-echo techniques. Radiology 238:549–559PubMedCrossRef
22.
Zurück zum Zitat Choi SH, Kim SH, Choi HJ, Park BK, Lee HJ (2004) Preoperative magnetic resonance imaging staging of uterine cervical carcinoma: results of prospective study. J Comput Assist Tomogr 28:620–627PubMedCrossRef Choi SH, Kim SH, Choi HJ, Park BK, Lee HJ (2004) Preoperative magnetic resonance imaging staging of uterine cervical carcinoma: results of prospective study. J Comput Assist Tomogr 28:620–627PubMedCrossRef
23.
Zurück zum Zitat Selman TJ, Mann C, Zamora J, Appleyard TL, Khan K (2008) Diagnostic accuracy of tests for lymph node status in primary cervical cancer: a systematic review and meta-analysis. CMAJ 178:855–862PubMed Selman TJ, Mann C, Zamora J, Appleyard TL, Khan K (2008) Diagnostic accuracy of tests for lymph node status in primary cervical cancer: a systematic review and meta-analysis. CMAJ 178:855–862PubMed
24.
Zurück zum Zitat Togashi K, Nishimura K, Sagoh T et al (1989) Carcinoma of the cervix: staging with MR imaging. Radiology 171:245–251PubMed Togashi K, Nishimura K, Sagoh T et al (1989) Carcinoma of the cervix: staging with MR imaging. Radiology 171:245–251PubMed
25.
Zurück zum Zitat Fujiwara K, Yoden E, Asakawa T et al (2000) Negative MRI findings with invasive cervical biopsy may indicate stage IA cervical carcinoma. Gynecol Oncol 79:451–456PubMedCrossRef Fujiwara K, Yoden E, Asakawa T et al (2000) Negative MRI findings with invasive cervical biopsy may indicate stage IA cervical carcinoma. Gynecol Oncol 79:451–456PubMedCrossRef
Metadaten
Titel
Uterine cervical carcinoma: a comparison of two- and three-dimensional T2-weighted turbo spin-echo MR imaging at 3.0 T for image quality and local-regional staging
verfasst von
Y. R. Shin
S. E. Rha
B. G. Choi
S. N. Oh
M. Y. Park
J. Y. Byun
Publikationsdatum
01.04.2013
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 4/2013
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-012-2603-2

Weitere Artikel der Ausgabe 4/2013

European Radiology 4/2013 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.