Skip to main content
Erschienen in: European Radiology 9/2013

01.09.2013 | GASTROINTESTINAL

A prospective feasibility study of sub-millisievert abdominopelvic CT using iterative reconstruction in Crohn’s disease

verfasst von: Siobhan B O’Neill, Patrick D Mc Laughlin, Lee Crush, Owen J O’Connor, Sebastian R Mc Williams, Orla Craig, Anne Marie Mc Garrigle, Fiona O’Neill, Jackie Bye, Max F. Ryan, Fergus Shanahan, Michael M Maher

Erschienen in: European Radiology | Ausgabe 9/2013

Einloggen, um Zugang zu erhalten

Abstract

Objective

Iterative reconstruction (IR) allows diagnostic CT imaging with less radiation exposure than filtered back projection (FBP). We studied an IR low-dose CT abdomen/pelvis (LDCTAP) protocol, designed to image at an effective dose (ED) approximating 1 mSv in patients with Crohn’s disease (CD).

Methods

Forty patients, mean age 37 ± 13.4 years (range 17–69), with CD underwent two synchronous CT protocols (conventional-dose (CDCTAP) and LDCTAP). CDCTAP and LDCTAP images were compared for diagnostic acceptability, yield, image quality and ED (in millisieverts). The optimal level of IR for LDCTAP was also studied.

Results

LDCTAP yielded a mean ED of 1.3 ± 0.8 mSv compared with 4.7 ± 2.9 mSv for CDCTAP, reducing ED by 73.7 ± 3.3 % (mean dose reduction, 3.5 ± 2.1 mSv; P < 0.001) and dose length product by 73.6 ± 2.6 % (P < 0.001). Sub-millisievert (0.84 mSv) imaging was performed for patients with a body mass index (BMI) less than 25 (i.e. 63 % of our cohort). LDCTAP resulted in increased image noise and reduced diagnostic acceptability compared with CDCTAP despite use of IR, but detection of extra-luminal complications was comparable.

Conclusion

Patients with suspected active CD can be adequately imaged using LDCTAP, yielding comparable information regarding extent, activity and complications of CD compared with CDCTAP, but with 74 % less dose. LDCTAP at doses equivalent to that of two abdominal radiographs represents a feasible alternative to CDCTAP.

Key points

Radiation dose is a concern when imaging patients with Crohn’s disease.
New techniques allow low-dose abdominopelvic CT with acceptable image quality.
Using hybrid iterative reconstruction, its diagnostic yield compares well with that of conventional CT.
Sub-millisievert CT of patients with Crohn’s disease appears technically and clinically feasible.
Literatur
1.
Zurück zum Zitat Huprick JE, Rosen MP, Fidler JL et al (2010) ACR appropriateness criteria on Crohn’s disease. J Am Coll Radiol 7:94–102CrossRef Huprick JE, Rosen MP, Fidler JL et al (2010) ACR appropriateness criteria on Crohn’s disease. J Am Coll Radiol 7:94–102CrossRef
2.
Zurück zum Zitat Schreyer SG, Seitz J, Feuerbach S et al (2004) Modern imaging using computer tomography and magnetic resonance imaging for inflammatory bowel disease (IBD). Inflamm Bowel Dis 10:45–54PubMedCrossRef Schreyer SG, Seitz J, Feuerbach S et al (2004) Modern imaging using computer tomography and magnetic resonance imaging for inflammatory bowel disease (IBD). Inflamm Bowel Dis 10:45–54PubMedCrossRef
3.
Zurück zum Zitat Desmond AN, O’ Regan K, Curran C et al (2008) Crohn’s disease: factors associated with exposure to high levels of diagnostic radiation. Gut 57:1524–9PubMedCrossRef Desmond AN, O’ Regan K, Curran C et al (2008) Crohn’s disease: factors associated with exposure to high levels of diagnostic radiation. Gut 57:1524–9PubMedCrossRef
4.
Zurück zum Zitat Cardis E, Vrijheid M, Blettner M et al (2007) The 15-country collaborative study of cancer risk among radiation workers in the nuclear industry: estimates of radiation-related cancer risks. Radiat Res 167:396–416PubMedCrossRef Cardis E, Vrijheid M, Blettner M et al (2007) The 15-country collaborative study of cancer risk among radiation workers in the nuclear industry: estimates of radiation-related cancer risks. Radiat Res 167:396–416PubMedCrossRef
5.
Zurück zum Zitat Mettler FA Jr, Huda W, Yoshizumi TT et al (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248:254–63PubMedCrossRef Mettler FA Jr, Huda W, Yoshizumi TT et al (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248:254–63PubMedCrossRef
6.
Zurück zum Zitat Leyendecker JR, Bloomfeld RS, DiSantis DJ et al (2009) MR enterography in the management of patients with Crohn disease. Radiographics 29:1827–46PubMedCrossRef Leyendecker JR, Bloomfeld RS, DiSantis DJ et al (2009) MR enterography in the management of patients with Crohn disease. Radiographics 29:1827–46PubMedCrossRef
7.
Zurück zum Zitat Fidler JL, Guimaraes L, Einstein DM (2009) MR imaging of the small bowel. Radiographics 29:1811–25PubMedCrossRef Fidler JL, Guimaraes L, Einstein DM (2009) MR imaging of the small bowel. Radiographics 29:1811–25PubMedCrossRef
8.
Zurück zum Zitat Prassopoulos P, Papanikolaou N, Grammatikakis J et al (2001) MR enteroclysis imaging of Crohn disease. Radiographics 21 Spec No:S161–72 Prassopoulos P, Papanikolaou N, Grammatikakis J et al (2001) MR enteroclysis imaging of Crohn disease. Radiographics 21 Spec No:S161–72
9.
Zurück zum Zitat Van Assche G, Dignass A, Panes J et al (2010) The second European evidence-based consensus on the diagnosis and management of Crohn’s disease: definitions and diagnosis. J Crohns Colitis 4:7–27PubMedCrossRef Van Assche G, Dignass A, Panes J et al (2010) The second European evidence-based consensus on the diagnosis and management of Crohn’s disease: definitions and diagnosis. J Crohns Colitis 4:7–27PubMedCrossRef
10.
Zurück zum Zitat McCollough CH, Primak AN, Braun N et al (2009) Strategies for reducing radiation dose in CT. Radiol Clin North Am 194:191–9 McCollough CH, Primak AN, Braun N et al (2009) Strategies for reducing radiation dose in CT. Radiol Clin North Am 194:191–9
11.
Zurück zum Zitat Fleischmann D, Boas FE (2011) Computed tomography – old ideas and new technology. Eur Radiol 21:510–7PubMedCrossRef Fleischmann D, Boas FE (2011) Computed tomography – old ideas and new technology. Eur Radiol 21:510–7PubMedCrossRef
12.
Zurück zum Zitat Silva AC, Lawder HJ, Hara A (2010) Innovations in CT dose reduction strategy: application of adaptive statistical iterative reconstruction algorithm. AJR AM J Roentgenol 194:191–9PubMedCrossRef Silva AC, Lawder HJ, Hara A (2010) Innovations in CT dose reduction strategy: application of adaptive statistical iterative reconstruction algorithm. AJR AM J Roentgenol 194:191–9PubMedCrossRef
13.
Zurück zum Zitat Desai GS, Uppot RN, Yu EW et al (2012) Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults. Eur Radiol 22:1631–40PubMedCrossRef Desai GS, Uppot RN, Yu EW et al (2012) Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults. Eur Radiol 22:1631–40PubMedCrossRef
14.
Zurück zum Zitat Mitsumori LM, Shuman WP, Busey JM et al (2012) Adaptive statistical iterative reconstruction versus filtered back projection in the same patient: 64 channel liver CT image quality and patient radiation dose. Eur Radiol 22:138–43PubMedCrossRef Mitsumori LM, Shuman WP, Busey JM et al (2012) Adaptive statistical iterative reconstruction versus filtered back projection in the same patient: 64 channel liver CT image quality and patient radiation dose. Eur Radiol 22:138–43PubMedCrossRef
15.
Zurück zum Zitat Winklehner A, Karlo C, Puippe G et al (2011) Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential. Eur Radiol 21:2521–6PubMedCrossRef Winklehner A, Karlo C, Puippe G et al (2011) Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential. Eur Radiol 21:2521–6PubMedCrossRef
16.
Zurück zum Zitat Desmond AN, O’Regan K, Malik N et al (2012) Selection of symptomatic patients with Crohn’s disease for abdominopelvic computed tomography: role of serum C-reactive protein. Can Assoc Radiol J 63:267–74PubMedCrossRef Desmond AN, O’Regan K, Malik N et al (2012) Selection of symptomatic patients with Crohn’s disease for abdominopelvic computed tomography: role of serum C-reactive protein. Can Assoc Radiol J 63:267–74PubMedCrossRef
17.
Zurück zum Zitat Bongartz G, Golding SJ, Jurik AG et al (2000) European guidelines on quality criteria for computed tomography, EUR 16262. The European Commission’s Study Group on Development of Quality Criteria for Computed Tomography. Office for Official Publications of the European Communities, Luxembourg Bongartz G, Golding SJ, Jurik AG et al (2000) European guidelines on quality criteria for computed tomography, EUR 16262. The European Commission’s Study Group on Development of Quality Criteria for Computed Tomography. Office for Official Publications of the European Communities, Luxembourg
18.
Zurück zum Zitat Bongartz G, Golding SJ, Jurik AG et al (2004) 2004 CT quality criteria. Office for Official Publications of the European Communities, Luxembourg Bongartz G, Golding SJ, Jurik AG et al (2004) 2004 CT quality criteria. Office for Official Publications of the European Communities, Luxembourg
19.
Zurück zum Zitat Prakash P, Kalra MK, Kambadakone AK et al (2010) Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique. Invest Radiol 45:202–10PubMedCrossRef Prakash P, Kalra MK, Kambadakone AK et al (2010) Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique. Invest Radiol 45:202–10PubMedCrossRef
20.
Zurück zum Zitat Singh S, Kalra MK, Hsieh J et al (2010) Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques. Radiology 257:373–83PubMedCrossRef Singh S, Kalra MK, Hsieh J et al (2010) Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques. Radiology 257:373–83PubMedCrossRef
21.
Zurück zum Zitat Kalra MK, Rizzo S, Maher MM et al (2005) Chest CT performed with z-axis modulation: scanning protocol and radiation dose. Radiology 237:303–8PubMedCrossRef Kalra MK, Rizzo S, Maher MM et al (2005) Chest CT performed with z-axis modulation: scanning protocol and radiation dose. Radiology 237:303–8PubMedCrossRef
22.
Zurück zum Zitat Kalra MK, Maher MM, Kamath RS et al (2004) 16-slice multidetector-row CT of the abdomen and pelvis: a study for optimization of z-axis modulation technique in 153 subjects. Radiology 233:241–249PubMedCrossRef Kalra MK, Maher MM, Kamath RS et al (2004) 16-slice multidetector-row CT of the abdomen and pelvis: a study for optimization of z-axis modulation technique in 153 subjects. Radiology 233:241–249PubMedCrossRef
23.
Zurück zum Zitat Kalra MK, Maher MM, Toth TL et al (2004) Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis. Radiology 232:347–53PubMedCrossRef Kalra MK, Maher MM, Toth TL et al (2004) Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis. Radiology 232:347–53PubMedCrossRef
24.
Zurück zum Zitat Marin D, Nelson RC, Schindera ST et al (2010) Low-tube voltage, high tube current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm – initial clinical experience. Radiology 254:145–53PubMedCrossRef Marin D, Nelson RC, Schindera ST et al (2010) Low-tube voltage, high tube current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm – initial clinical experience. Radiology 254:145–53PubMedCrossRef
25.
Zurück zum Zitat Nakayama Y, Awai K, Funama Y et al (2006) Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography. AJR Am J Roentgenol 187:W490–7PubMedCrossRef Nakayama Y, Awai K, Funama Y et al (2006) Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography. AJR Am J Roentgenol 187:W490–7PubMedCrossRef
26.
Zurück zum Zitat Jackson VP, Cushing T, Abujudeh HH et al (2009) RADPEER scoring white paper. J Am Coll Radiol 6:21–5PubMedCrossRef Jackson VP, Cushing T, Abujudeh HH et al (2009) RADPEER scoring white paper. J Am Coll Radiol 6:21–5PubMedCrossRef
27.
Zurück zum Zitat Brenner DJ, Hall EJ (2007) Computed tomography – an increasing source of radiation exposure. N Engl J Med 357:2277–84PubMedCrossRef Brenner DJ, Hall EJ (2007) Computed tomography – an increasing source of radiation exposure. N Engl J Med 357:2277–84PubMedCrossRef
28.
Zurück zum Zitat Kinsella SM, Coyle JP, Long EB et al (2010) Maintenance haemodialysis patients have high cumulative radiation exposure. Kidney Int 78:789–93PubMedCrossRef Kinsella SM, Coyle JP, Long EB et al (2010) Maintenance haemodialysis patients have high cumulative radiation exposure. Kidney Int 78:789–93PubMedCrossRef
29.
Zurück zum Zitat O’Connell OJ, McWilliams S, McGarrigle A et al (2012) Radiologic imaging in cystic fibrosis: cumulative effective dose and changing trends over 2 decades. Chest 141:1575–83PubMedCrossRef O’Connell OJ, McWilliams S, McGarrigle A et al (2012) Radiologic imaging in cystic fibrosis: cumulative effective dose and changing trends over 2 decades. Chest 141:1575–83PubMedCrossRef
30.
Zurück zum Zitat O’Regan K, O’Connor OJ, O’Neill SB et al (2012) Plain abdominal radiographs in patients with Crohn’s disease: radiological findings and diagnostic value. Clin Radiol 67:774–81PubMedCrossRef O’Regan K, O’Connor OJ, O’Neill SB et al (2012) Plain abdominal radiographs in patients with Crohn’s disease: radiological findings and diagnostic value. Clin Radiol 67:774–81PubMedCrossRef
31.
Zurück zum Zitat Flicek KT, Hara AK, Silva AC et al (2010) Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study. AJR Am J Roentgenol 195:126–31PubMedCrossRef Flicek KT, Hara AK, Silva AC et al (2010) Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study. AJR Am J Roentgenol 195:126–31PubMedCrossRef
32.
Zurück zum Zitat Hara AK, Paden RG, Silva AC et al (2009) Iterative reconstruction techniques for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193:764–71PubMedCrossRef Hara AK, Paden RG, Silva AC et al (2009) Iterative reconstruction techniques for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193:764–71PubMedCrossRef
33.
Zurück zum Zitat May MS, Wust W, Brand M et al (2011) Dose reduction in abdominal computed tomography: intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography. Invest Radiol 46:465–70PubMedCrossRef May MS, Wust W, Brand M et al (2011) Dose reduction in abdominal computed tomography: intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography. Invest Radiol 46:465–70PubMedCrossRef
34.
Zurück zum Zitat Sagara Y, Hara AK, Pavlicek W et al (2010) Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients. AJR Am J Roentgenol 195:713–9PubMedCrossRef Sagara Y, Hara AK, Pavlicek W et al (2010) Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients. AJR Am J Roentgenol 195:713–9PubMedCrossRef
35.
Zurück zum Zitat Schindera ST, Nelson RC, DeLong DM et al (2007) Multi-detector row CT of the small bowel: peak enhancement temporal window—initial experience. Radiology 243:438–44PubMedCrossRef Schindera ST, Nelson RC, DeLong DM et al (2007) Multi-detector row CT of the small bowel: peak enhancement temporal window—initial experience. Radiology 243:438–44PubMedCrossRef
Metadaten
Titel
A prospective feasibility study of sub-millisievert abdominopelvic CT using iterative reconstruction in Crohn’s disease
verfasst von
Siobhan B O’Neill
Patrick D Mc Laughlin
Lee Crush
Owen J O’Connor
Sebastian R Mc Williams
Orla Craig
Anne Marie Mc Garrigle
Fiona O’Neill
Jackie Bye
Max F. Ryan
Fergus Shanahan
Michael M Maher
Publikationsdatum
01.09.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 9/2013
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-013-2858-2

Weitere Artikel der Ausgabe 9/2013

European Radiology 9/2013 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.