01.07.2014 | Cardiac
Cardiac valve calcifications on low-dose unenhanced ungated chest computed tomography: inter-observer and inter-examination reliability, agreement and variability
verfasst von:
Robbert W. van Hamersvelt, Martin J. Willemink, Richard A. P. Takx, Anouk L. M. Eikendal, Ricardo P. J. Budde, Tim Leiner, Christian P. Mol, Ivana Isgum, Pim A. de Jong
Erschienen in:
European Radiology
|
Ausgabe 7/2014
Einloggen, um Zugang zu erhalten
Abstract
Objectives
To determine inter-observer and inter-examination variability for aortic valve calcification (AVC) and mitral valve and annulus calcification (MC) in low-dose unenhanced ungated lung cancer screening chest computed tomography (CT).
Methods
We included 578 lung cancer screening trial participants who were examined by CT twice within 3 months to follow indeterminate pulmonary nodules. On these CTs, AVC and MC were measured in cubic millimetres. One hundred CTs were examined by five observers to determine the inter-observer variability. Reliability was assessed by kappa statistics (κ) and intra-class correlation coefficients (ICCs). Variability was expressed as the mean difference ± standard deviation (SD).
Results
Inter-examination reliability was excellent for AVC (κ = 0.94, ICC = 0.96) and MC (κ = 0.95, ICC = 0.90). Inter-examination variability was 12.7 ± 118.2 mm3 for AVC and 31.5 ± 219.2 mm3 for MC. Inter-observer reliability ranged from κ = 0.68 to κ = 0.92 for AVC and from κ = 0.20 to κ = 0.66 for MC. Inter-observer ICC was 0.94 for AVC and ranged from 0.56 to 0.97 for MC. Inter-observer variability ranged from -30.5 ± 252.0 mm3 to 84.0 ± 240.5 mm3 for AVC and from -95.2 ± 210.0 mm3 to 303.7 ± 501.6 mm3 for MC.
Conclusions
AVC can be quantified with excellent reliability on ungated unenhanced low-dose chest CT, but manual detection of MC can be subject to substantial inter-observer variability. Lung cancer screening CT may be used for detection and quantification of cardiac valve calcifications.
Key points
• Low-dose unenhanced ungated chest computed tomography can detect cardiac valve calcifications.
• However, calcified cardiac valves are not reported by most radiologists.
• Inter-observer and inter-examination variability of aortic valve calcifications is sufficient for longitudinal studies.
• Volumetric measurement variability of mitral valve and annulus calcifications is substantial.