Skip to main content
Erschienen in: European Radiology 5/2015

01.05.2015 | Interventional

Preliminary clinical experience with a dedicated interventional robotic system for CT-guided biopsies of lung lesions: a comparison with the conventional manual technique

verfasst von: Michele Anzidei, Renato Argirò, Andrea Porfiri, Fabrizio Boni, Marco Anile, Fulvio Zaccagna, Domenico Vitolo, Luca Saba, Alessandro Napoli, Andrea Leonardi, Flavia Longo, Federico Venuta, Mario Bezzi, Carlo Catalano

Erschienen in: European Radiology | Ausgabe 5/2015

Einloggen, um Zugang zu erhalten

Abstract

Objective

Evaluate the performance of a robotic system for CT-guided lung biopsy in comparison to the conventional manual technique.

Materials and methods

One hundred patients referred for CT-guided lung biopsy were randomly assigned to group A (robot-assisted procedure) or group B (conventional procedure). Size, distance from entry point and position in lung of target lesions were evaluated to assess homogeneity differences between the two groups. Procedure duration, dose length product (DLP), precision of needle positioning, diagnostic performance of the biopsy and rate of complications were evaluated to assess the clinical performance of the robotic system as compared to the conventional technique.

Results

All biopsies were successfully performed. The size (p = 0.41), distance from entry point (p = 0.86) and position in lung (p = 0.32) of target lesions were similar in both groups (p = 0.05). Procedure duration and radiation dose were significantly reduced in group A as compared to group B (p = 0.001). Precision of needle positioning, diagnostic performance of the biopsy and rate of complications were similar in both groups (p = 0.05).

Conclusion

Robot-assisted CT-guided lung biopsy can be performed safely and with high diagnostic accuracy, reducing procedure duration and radiation dose in comparison to the conventional manual technique.

Key Points

CT-guided biopsy is the main procedure to obtain diagnosis in lung tumours.
The robotic device facilitates percutaneous needle placement under CT guidance.
Robot-assisted CT-guided lung biopsy reduces procedure duration and radiation dose.
Literatur
1.
Zurück zum Zitat MacMahon H, Austin JH, Gamsu G, Herold CJ, Jett JR, Naidich DP, Patz EF Jr, Swensen SJ, Fleischner Society (2005) Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society. Radiology 237:395–400CrossRefPubMed MacMahon H, Austin JH, Gamsu G, Herold CJ, Jett JR, Naidich DP, Patz EF Jr, Swensen SJ, Fleischner Society (2005) Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society. Radiology 237:395–400CrossRefPubMed
2.
Zurück zum Zitat Naidich DP, Bankier AA, MacMahon H, Schaefer-Prokop CM, Pistolesi M, Goo JM, Macchiarini P, Crapo JD, Herold CJ, Austin JH, Travis WD (2013) Recommendations for the management of subsolid pulmonari nodules detected at CT: a statement from the Fleischner Society. Radiology 266:304–317CrossRefPubMed Naidich DP, Bankier AA, MacMahon H, Schaefer-Prokop CM, Pistolesi M, Goo JM, Macchiarini P, Crapo JD, Herold CJ, Austin JH, Travis WD (2013) Recommendations for the management of subsolid pulmonari nodules detected at CT: a statement from the Fleischner Society. Radiology 266:304–317CrossRefPubMed
3.
Zurück zum Zitat Gould MK, Donington J, Lynch WR, Mazzone PJ, Midthun DE, Naidich DP, Wiener RS (2013) Evaluation of individuals with pulmonary nodules: when is it lung cancer? Diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest 143:e93S–e120SCrossRefPubMedCentralPubMed Gould MK, Donington J, Lynch WR, Mazzone PJ, Midthun DE, Naidich DP, Wiener RS (2013) Evaluation of individuals with pulmonary nodules: when is it lung cancer? Diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest 143:e93S–e120SCrossRefPubMedCentralPubMed
4.
Zurück zum Zitat Tuna T, Ozkaya S, Dirican A, Findik S, Atici AG, Erkan L (2013) Diagnostic efficacy of computed tomography-guided transthoracic needle aspiration and biopsy in patients with pulmonary disease. Onco Targets Ther 6:1553–1557PubMedCentralPubMed Tuna T, Ozkaya S, Dirican A, Findik S, Atici AG, Erkan L (2013) Diagnostic efficacy of computed tomography-guided transthoracic needle aspiration and biopsy in patients with pulmonary disease. Onco Targets Ther 6:1553–1557PubMedCentralPubMed
6.
Zurück zum Zitat Kim GR, Hur J, Lee SM, Lee HJ, Hong YJ, Nam JE, Kim HS, Kim YJ, Choi BW, Kim TH, Choe KO (2011) CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance. Eur Radiol 21:232–239CrossRefPubMed Kim GR, Hur J, Lee SM, Lee HJ, Hong YJ, Nam JE, Kim HS, Kim YJ, Choi BW, Kim TH, Choe KO (2011) CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance. Eur Radiol 21:232–239CrossRefPubMed
7.
Zurück zum Zitat Prosch H, Stadler A, Schilling M, Bürklin S, Eisenhuber E, Schober E, Mostbeck G (2012) CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: accuracy, complications and radiation dose. Eur J Radiol 81:1029–1033CrossRefPubMed Prosch H, Stadler A, Schilling M, Bürklin S, Eisenhuber E, Schober E, Mostbeck G (2012) CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: accuracy, complications and radiation dose. Eur J Radiol 81:1029–1033CrossRefPubMed
9.
Zurück zum Zitat Grasso RF, Faiella E, Luppi G, Schena E, Giurazza F, Del Vescovo R, D'Agostino F, Cazzato RL, Beomonte Zobel B (2013) Percutaneous lung biopsy: comparison between an augmented reality CT navigation system and standard CT-guided technique. Int J Comput Assist Radiol Surg 8:837–848CrossRefPubMed Grasso RF, Faiella E, Luppi G, Schena E, Giurazza F, Del Vescovo R, D'Agostino F, Cazzato RL, Beomonte Zobel B (2013) Percutaneous lung biopsy: comparison between an augmented reality CT navigation system and standard CT-guided technique. Int J Comput Assist Radiol Surg 8:837–848CrossRefPubMed
10.
Zurück zum Zitat Kettenbach J, Kronreif G, Melzer A, Fichtinger G, Stoianovici D, Cleary K (2007) Ultrasound-, CT- and MR-guided robot-assisted interventions. In: Neri E, Caramella D, Bartolozzi C (eds) Image processing in radiology: current applications. Springer, Heidelberg, pp 391–404 Kettenbach J, Kronreif G, Melzer A, Fichtinger G, Stoianovici D, Cleary K (2007) Ultrasound-, CT- and MR-guided robot-assisted interventions. In: Neri E, Caramella D, Bartolozzi C (eds) Image processing in radiology: current applications. Springer, Heidelberg, pp 391–404
11.
Zurück zum Zitat Koethe Y, Xu S, Velusamy G, Wood BJ, Venkatesan AM (2014) Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study. Eur Radiol 24(3):723–730 Koethe Y, Xu S, Velusamy G, Wood BJ, Venkatesan AM (2014) Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study. Eur Radiol 24(3):723–730
12.
Zurück zum Zitat Abdullah BJ, Yeong CH, Goh KL, Yoong BK, Ho GF, Yim CC, Kulkarni A (2014) Robot-assisted radiofrequency ablation of primary and secondary liver tumours: early experience. Eur Radiol 24:79–85CrossRefPubMedCentralPubMed Abdullah BJ, Yeong CH, Goh KL, Yoong BK, Ho GF, Yim CC, Kulkarni A (2014) Robot-assisted radiofrequency ablation of primary and secondary liver tumours: early experience. Eur Radiol 24:79–85CrossRefPubMedCentralPubMed
13.
Zurück zum Zitat Sacks D, McClenny TE, Cardella JF, Lewis CA (2003) Society of Interventional Radiology clinical practice guidelines. J Vasc Interv Radiol 14:S199–S202CrossRefPubMed Sacks D, McClenny TE, Cardella JF, Lewis CA (2003) Society of Interventional Radiology clinical practice guidelines. J Vasc Interv Radiol 14:S199–S202CrossRefPubMed
14.
Zurück zum Zitat von Jako CR, Zuk Y, Zur O, Gilboa P (2013) A novel accurate minioptical tracking system for percutaneous needle placement. IEEE Trans Biomed Eng 60:2222–2225CrossRef von Jako CR, Zuk Y, Zur O, Gilboa P (2013) A novel accurate minioptical tracking system for percutaneous needle placement. IEEE Trans Biomed Eng 60:2222–2225CrossRef
15.
Zurück zum Zitat Krücker J, Xu S, Glossop N, Viswanathan A, Borgert J, Schulz H, Wood BJ (2007) Electromagnetic tracking for thermal ablation and biopsy guidance: clinical evaluation of spatial accuracy. J Vasc Interv Radiol 18:1141–1150CrossRefPubMedCentralPubMed Krücker J, Xu S, Glossop N, Viswanathan A, Borgert J, Schulz H, Wood BJ (2007) Electromagnetic tracking for thermal ablation and biopsy guidance: clinical evaluation of spatial accuracy. J Vasc Interv Radiol 18:1141–1150CrossRefPubMedCentralPubMed
16.
Zurück zum Zitat Tovar-Arriaga S, Tita R, Pedraza-Ortega JC, Gorrostieta E, Kalender WA (2011) Development of a robotic FD-CT-guided navigation system for needle placement-preliminary accuracy tests. Int J Med Robot 7:225–236CrossRefPubMed Tovar-Arriaga S, Tita R, Pedraza-Ortega JC, Gorrostieta E, Kalender WA (2011) Development of a robotic FD-CT-guided navigation system for needle placement-preliminary accuracy tests. Int J Med Robot 7:225–236CrossRefPubMed
17.
Zurück zum Zitat Yanof J, Haaga J, Klahr P (2001) CT-integrated robot for interventional procedures: preliminary experiment and computer human interfaces. Comput Aided Surg 6:352–359CrossRefPubMed Yanof J, Haaga J, Klahr P (2001) CT-integrated robot for interventional procedures: preliminary experiment and computer human interfaces. Comput Aided Surg 6:352–359CrossRefPubMed
18.
Zurück zum Zitat Schulz B, Eichler K, Siebenhandl P et al (2012) Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study. Eur Radiol 23:198–204CrossRefPubMed Schulz B, Eichler K, Siebenhandl P et al (2012) Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study. Eur Radiol 23:198–204CrossRefPubMed
19.
Zurück zum Zitat Su L-M, Stoianovici D, Jarrett TW et al (2002) Robotic percutaneous access to the kidney: comparison with standard manual access. J Endourol 16:471–475CrossRefPubMed Su L-M, Stoianovici D, Jarrett TW et al (2002) Robotic percutaneous access to the kidney: comparison with standard manual access. J Endourol 16:471–475CrossRefPubMed
Metadaten
Titel
Preliminary clinical experience with a dedicated interventional robotic system for CT-guided biopsies of lung lesions: a comparison with the conventional manual technique
verfasst von
Michele Anzidei
Renato Argirò
Andrea Porfiri
Fabrizio Boni
Marco Anile
Fulvio Zaccagna
Domenico Vitolo
Luca Saba
Alessandro Napoli
Andrea Leonardi
Flavia Longo
Federico Venuta
Mario Bezzi
Carlo Catalano
Publikationsdatum
01.05.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 5/2015
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-014-3508-z

Weitere Artikel der Ausgabe 5/2015

European Radiology 5/2015 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.