Skip to main content
Erschienen in: European Radiology 12/2015

01.12.2015 | Chest

C-Arm Cone-Beam CT Virtual Navigation-Guided Percutaneous Mediastinal Mass Biopsy: Diagnostic Accuracy and Complications

verfasst von: Hyungjin Kim, Chang Min Park, Sang Min Lee, Jin Mo Goo

Erschienen in: European Radiology | Ausgabe 12/2015

Einloggen, um Zugang zu erhalten

Abstract

Objectives

To assess the usefulness of C-arm cone-beam computed tomography (CBCT) virtual navigation-guided percutaneous mediastinal mass biopsy in terms of diagnostic accuracy and complication rates.

Methods

Seventy-eight CBCT virtual navigation-guided percutaneous mediastinal mass biopsies were performed in 75 patients (M:F, 38:37; mean age, 48.55 ± 18.76 years). The procedural details, diagnostic sensitivity, specificity, accuracy and complication rate were investigated.

Results

Mean lesion size was 6.80 ± 3.08 cm, skin-to-target distance was 3.67 ± 1.80 cm, core needle biopsy rate was 96.2 % (75/78), needle indwelling time was 9.29 ± 4.34 min, total procedure time was 13.26 ± 5.29 min, number of biopsy specimens obtained was 3.13 ± 1.02, number of CBCTs performed was 3.03 ± 0.68, rate of lesion border discrimination from abutting mediastinal structures on CBCT was 26.9 % (21/78), technical success rate was 100 % (78/78), estimated effective dose was 5.33 ± 4.99 mSv, and the dose area product was 12,723.68 ± 10,665.74 mGy⋅cm2. Among the 78 biopsies, 69 were malignant, 7 were benign and 2 were indeterminate. Diagnostic sensitivity, specificity and accuracy for the diagnosis of malignancies were 97.1 % (67/69), 100 % (7/7) and 97.4 % (74/76), respectively, with a complication rate of 3.85 % (3/78), all of which were small pneumothoraces.

Conclusions

CBCT virtual navigation-guided biopsy is a highly accurate and safe procedure for the evaluation of mediastinal lesions.

Key Points

CBCT virtual navigation-guided percutaneous mediastinal biopsy is highly accurate
CBCT virtual navigation-guided percutaneous mediastinal biopsy is a safe procedure
Mediastinal vascular injury can be avoided under CBCT virtual navigation guidance
Literatur
1.
Zurück zum Zitat Gupta S, Seaberg K, Wallace MJ et al (2005) Imaging-guided percutaneous biopsy of mediastinal lesions: different approaches and anatomic considerations. Radiographics 25:763–786CrossRefPubMed Gupta S, Seaberg K, Wallace MJ et al (2005) Imaging-guided percutaneous biopsy of mediastinal lesions: different approaches and anatomic considerations. Radiographics 25:763–786CrossRefPubMed
2.
Zurück zum Zitat de Jiao C, Li TF, Han XW et al (2014) Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions. Diagn Interv Radiol 20:470–474PubMedCentralCrossRef de Jiao C, Li TF, Han XW et al (2014) Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions. Diagn Interv Radiol 20:470–474PubMedCentralCrossRef
3.
Zurück zum Zitat Carlson SK, Felmlee JP, Bender CE et al (2005) CT fluoroscopy-guided biopsy of the lung or upper abdomen with a breath-hold monitoring and feedback system: a prospective randomized controlled clinical trial. Radiology 237:701–708CrossRefPubMed Carlson SK, Felmlee JP, Bender CE et al (2005) CT fluoroscopy-guided biopsy of the lung or upper abdomen with a breath-hold monitoring and feedback system: a prospective randomized controlled clinical trial. Radiology 237:701–708CrossRefPubMed
4.
Zurück zum Zitat Choi JW, Park CM, Goo JM et al (2012) C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (≤20 mm) lung nodules: diagnostic accuracy and complications in 161 patients. AJR Am J Roentgenol 199:W322–W330CrossRefPubMed Choi JW, Park CM, Goo JM et al (2012) C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (≤20 mm) lung nodules: diagnostic accuracy and complications in 161 patients. AJR Am J Roentgenol 199:W322–W330CrossRefPubMed
5.
Zurück zum Zitat Yankelevitz DF, Vazquez M, Henschke CI (2000) Special techniques in transthoracic needle biopsy of pulmonary nodules. Radiol Clin N Am 38:267–279CrossRefPubMed Yankelevitz DF, Vazquez M, Henschke CI (2000) Special techniques in transthoracic needle biopsy of pulmonary nodules. Radiol Clin N Am 38:267–279CrossRefPubMed
6.
Zurück zum Zitat Nawfel RD, Judy PF, Silverman SG, Hooton S, Tuncali K, Adams DF (2000) Patient and personnel exposure during CT fluoroscopy-guided interventional procedures. Radiology 216:180–184CrossRefPubMed Nawfel RD, Judy PF, Silverman SG, Hooton S, Tuncali K, Adams DF (2000) Patient and personnel exposure during CT fluoroscopy-guided interventional procedures. Radiology 216:180–184CrossRefPubMed
7.
Zurück zum Zitat Wallace MJ, Kuo MD, Glaiberman C et al (2009) Three-dimensional C-arm cone-beam CT: applications in the interventional suite. J Vasc Interv Radiol 20:S523–S537CrossRefPubMed Wallace MJ, Kuo MD, Glaiberman C et al (2009) Three-dimensional C-arm cone-beam CT: applications in the interventional suite. J Vasc Interv Radiol 20:S523–S537CrossRefPubMed
8.
Zurück zum Zitat Choo JY, Park CM, Lee NK, Lee SM, Lee HJ, Goo JM (2013) Percutaneous transthoracic needle biopsy of small (≤1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance. Eur Radiol 23:712–719CrossRefPubMed Choo JY, Park CM, Lee NK, Lee SM, Lee HJ, Goo JM (2013) Percutaneous transthoracic needle biopsy of small (≤1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance. Eur Radiol 23:712–719CrossRefPubMed
9.
Zurück zum Zitat Braak SJ, Herder GJ, van Heesewijk JP, van Strijen MJ (2012) Pulmonary masses: initial results of cone-beam CT guidance with needle planning software for percutaneous lung biopsy. Cardiovasc Intervent Radiol 35:1414–1421CrossRefPubMed Braak SJ, Herder GJ, van Heesewijk JP, van Strijen MJ (2012) Pulmonary masses: initial results of cone-beam CT guidance with needle planning software for percutaneous lung biopsy. Cardiovasc Intervent Radiol 35:1414–1421CrossRefPubMed
10.
Zurück zum Zitat Cheung JY, Kim Y, Shim SS, Lim SM (2011) Combined fluoroscopy- and CT-guided transthoracic needle biopsy using a C-arm cone-beam CT system: comparison with fluoroscopy-guided biopsy. Korean J Radiol 12:89–96PubMedCentralCrossRefPubMed Cheung JY, Kim Y, Shim SS, Lim SM (2011) Combined fluoroscopy- and CT-guided transthoracic needle biopsy using a C-arm cone-beam CT system: comparison with fluoroscopy-guided biopsy. Korean J Radiol 12:89–96PubMedCentralCrossRefPubMed
11.
Zurück zum Zitat Choi MJ, Kim Y, Hong YS, Shim SS, Lim SM, Lee JK (2012) Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety. Br J Radiol 85:e182–e187PubMedCentralCrossRefPubMed Choi MJ, Kim Y, Hong YS, Shim SS, Lim SM, Lee JK (2012) Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety. Br J Radiol 85:e182–e187PubMedCentralCrossRefPubMed
12.
Zurück zum Zitat Hwang HS, Chung MJ, Lee JW, Shin SW, Lee KS (2010) C-arm cone-beam CT-guided percutaneous transthoracic lung biopsy: usefulness in evaluation of small pulmonary nodules. AJR Am J Roentgenol 195:W400–W407CrossRefPubMed Hwang HS, Chung MJ, Lee JW, Shin SW, Lee KS (2010) C-arm cone-beam CT-guided percutaneous transthoracic lung biopsy: usefulness in evaluation of small pulmonary nodules. AJR Am J Roentgenol 195:W400–W407CrossRefPubMed
13.
Zurück zum Zitat Jin KN, Park CM, Goo JM et al (2010) Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems. Eur Radiol 20:2108–2115CrossRefPubMed Jin KN, Park CM, Goo JM et al (2010) Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems. Eur Radiol 20:2108–2115CrossRefPubMed
14.
Zurück zum Zitat Lee SM, Park CM, Lee KH, Bahn YE, Kim JI, Goo JM (2014) C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients. Radiology 271:291–300CrossRefPubMed Lee SM, Park CM, Lee KH, Bahn YE, Kim JI, Goo JM (2014) C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients. Radiology 271:291–300CrossRefPubMed
15.
Zurück zum Zitat Lee WJ, Chong S, Seo JS, Shim HJ (2012) Transthoracic fine-needle aspiration biopsy of the lungs using a C-arm cone-beam CT system: diagnostic accuracy and post-procedural complications. Br J Radiol 85:e217–e222PubMedCentralCrossRefPubMed Lee WJ, Chong S, Seo JS, Shim HJ (2012) Transthoracic fine-needle aspiration biopsy of the lungs using a C-arm cone-beam CT system: diagnostic accuracy and post-procedural complications. Br J Radiol 85:e217–e222PubMedCentralCrossRefPubMed
16.
Zurück zum Zitat Kim JI, Park CM, Lee SM, Goo JM (2015) Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients. Eur Radiol. doi:10.1007/s00330-015-3601-y Kim JI, Park CM, Lee SM, Goo JM (2015) Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients. Eur Radiol. doi:10.​1007/​s00330-015-3601-y
17.
Zurück zum Zitat Carrafiello G, Fontana F, Mangini M et al (2012) Initial experience with percutaneous biopsies of bone lesions using XperGuide cone-beam CT (CBCT): technical note. Radiol Med 117:1386–1397CrossRefPubMed Carrafiello G, Fontana F, Mangini M et al (2012) Initial experience with percutaneous biopsies of bone lesions using XperGuide cone-beam CT (CBCT): technical note. Radiol Med 117:1386–1397CrossRefPubMed
18.
Zurück zum Zitat Leschka SC, Babic D, El Shikh S, Wossmann C, Schumacher M, Taschner CA (2012) C-arm cone beam computed tomography needle path overlay for image-guided procedures of the spine and pelvis. Neuroradiology 54:215–223CrossRefPubMed Leschka SC, Babic D, El Shikh S, Wossmann C, Schumacher M, Taschner CA (2012) C-arm cone beam computed tomography needle path overlay for image-guided procedures of the spine and pelvis. Neuroradiology 54:215–223CrossRefPubMed
19.
Zurück zum Zitat Whitten CR, Khan S, Munneke GJ, Grubnic S (2007) A diagnostic approach to mediastinal abnormalities. Radiographics 27:657–671CrossRefPubMed Whitten CR, Khan S, Munneke GJ, Grubnic S (2007) A diagnostic approach to mediastinal abnormalities. Radiographics 27:657–671CrossRefPubMed
20.
Zurück zum Zitat Riedel RF, Burfeind WR Jr (2006) Thymoma: benign appearance, malignant potential. Oncologist 11:887–894CrossRefPubMed Riedel RF, Burfeind WR Jr (2006) Thymoma: benign appearance, malignant potential. Oncologist 11:887–894CrossRefPubMed
21.
Zurück zum Zitat Suster S, Moran CA (2006) Thymoma classification: current status and future trends. Am J Clin Pathol 125:542–554CrossRefPubMed Suster S, Moran CA (2006) Thymoma classification: current status and future trends. Am J Clin Pathol 125:542–554CrossRefPubMed
22.
Zurück zum Zitat Gupta S, Wallace MJ, Morello FA Jr, Ahrar K, Hicks ME (2002) CT-guided percutaneous needle biopsy of intrathoracic lesions by using the transsternal approach: experience in 37 patients. Radiology 222:57–62CrossRefPubMed Gupta S, Wallace MJ, Morello FA Jr, Ahrar K, Hicks ME (2002) CT-guided percutaneous needle biopsy of intrathoracic lesions by using the transsternal approach: experience in 37 patients. Radiology 222:57–62CrossRefPubMed
23.
Zurück zum Zitat Hagberg H, Ahlstrom HK, Magnusson A, Sundstrom C, Astrom GK (2000) Value of transsternal core biopsy in patients with a newly diagnosed mediastinal mass. Acta Oncol 39:195–198CrossRefPubMed Hagberg H, Ahlstrom HK, Magnusson A, Sundstrom C, Astrom GK (2000) Value of transsternal core biopsy in patients with a newly diagnosed mediastinal mass. Acta Oncol 39:195–198CrossRefPubMed
24.
Zurück zum Zitat Kulkarni S, Kulkarni A, Roy D, Thakur MH (2008) Percutaneous computed tomography-guided core biopsy for the diagnosis of mediastinal masses. Ann Thorac Med 3:13–17PubMedCentralCrossRefPubMed Kulkarni S, Kulkarni A, Roy D, Thakur MH (2008) Percutaneous computed tomography-guided core biopsy for the diagnosis of mediastinal masses. Ann Thorac Med 3:13–17PubMedCentralCrossRefPubMed
25.
Zurück zum Zitat Lin ZY, Li YG (2009) Artificial pneumothorax with position adjustment for computed tomography-guided percutaneous core biopsy of mediastinum lesions. Ann Thorac Surg 87:920–924CrossRefPubMed Lin ZY, Li YG (2009) Artificial pneumothorax with position adjustment for computed tomography-guided percutaneous core biopsy of mediastinum lesions. Ann Thorac Surg 87:920–924CrossRefPubMed
26.
Zurück zum Zitat Priola AM, Priola SM, Cataldi A et al (2008) CT-guided percutaneous transthoracic biopsy in the diagnosis of mediastinal masses: evaluation of 73 procedures. Radiol Med 113:3–15CrossRefPubMed Priola AM, Priola SM, Cataldi A et al (2008) CT-guided percutaneous transthoracic biopsy in the diagnosis of mediastinal masses: evaluation of 73 procedures. Radiol Med 113:3–15CrossRefPubMed
27.
Zurück zum Zitat Zwischenberger JB, Savage C, Alpard SK, Anderson CM, Marroquin S, Goodacre BW (2002) Mediastinal transthoracic needle and core lymph node biopsy: should it replace mediastinoscopy? Chest 121:1165–1170CrossRefPubMed Zwischenberger JB, Savage C, Alpard SK, Anderson CM, Marroquin S, Goodacre BW (2002) Mediastinal transthoracic needle and core lymph node biopsy: should it replace mediastinoscopy? Chest 121:1165–1170CrossRefPubMed
28.
Zurück zum Zitat Busser WM, Braak SJ, Futterer JJ et al (2013) Cone beam CT guidance provides superior accuracy for complex needle paths compared with CT guidance. Br J Radiol 86:20130310PubMedCentralCrossRefPubMed Busser WM, Braak SJ, Futterer JJ et al (2013) Cone beam CT guidance provides superior accuracy for complex needle paths compared with CT guidance. Br J Radiol 86:20130310PubMedCentralCrossRefPubMed
29.
Zurück zum Zitat Greif J, Staroselsky AN, Gernjac M et al (1999) Percutaneous core needle biopsy in the diagnosis of mediastinal tumors. Lung Cancer 25:169–173CrossRefPubMed Greif J, Staroselsky AN, Gernjac M et al (1999) Percutaneous core needle biopsy in the diagnosis of mediastinal tumors. Lung Cancer 25:169–173CrossRefPubMed
30.
Zurück zum Zitat Sklair-Levy M, Polliack A, Shaham D et al (2000) CT-guided core-needle biopsy in the diagnosis of mediastinal lymphoma. Eur Radiol 10:714–718CrossRefPubMed Sklair-Levy M, Polliack A, Shaham D et al (2000) CT-guided core-needle biopsy in the diagnosis of mediastinal lymphoma. Eur Radiol 10:714–718CrossRefPubMed
31.
Zurück zum Zitat Zinzani PL, Corneli G, Cancellieri A et al (1999) Core needle biopsy is effective in the initial diagnosis of mediastinal lymphoma. Haematologica 84:600–603PubMed Zinzani PL, Corneli G, Cancellieri A et al (1999) Core needle biopsy is effective in the initial diagnosis of mediastinal lymphoma. Haematologica 84:600–603PubMed
32.
Zurück zum Zitat Schegerer AA, Lechel U, Ritter M, Weisser G, Fink C, Brix G (2014) Dose and image quality of cone-beam computed tomography as compared with conventional multislice computed tomography in abdominal imaging. Investig Radiol 49:675–684CrossRef Schegerer AA, Lechel U, Ritter M, Weisser G, Fink C, Brix G (2014) Dose and image quality of cone-beam computed tomography as compared with conventional multislice computed tomography in abdominal imaging. Investig Radiol 49:675–684CrossRef
33.
Zurück zum Zitat Lee CH, Goo JM, Ye HJ et al (2008) Radiation dose modulation techniques in the multidetector CT era: from basics to practice. Radiographics 28:1451–1459CrossRefPubMed Lee CH, Goo JM, Ye HJ et al (2008) Radiation dose modulation techniques in the multidetector CT era: from basics to practice. Radiographics 28:1451–1459CrossRefPubMed
Metadaten
Titel
C-Arm Cone-Beam CT Virtual Navigation-Guided Percutaneous Mediastinal Mass Biopsy: Diagnostic Accuracy and Complications
verfasst von
Hyungjin Kim
Chang Min Park
Sang Min Lee
Jin Mo Goo
Publikationsdatum
01.12.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 12/2015
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-015-3762-8

Weitere Artikel der Ausgabe 12/2015

European Radiology 12/2015 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.