Abstract

Technological advances in the domain of digital signal processing adapted to cochlear implants (CI) are partially responsible for the ever-improving outcomes observed with this neural prosthesis. The goal of the present study was to evaluate audiometric outcomes with a new signal processing strategy implemented in Oticon Medical-Neurelec cochlear implant systems, the xDP strategy. The core of this approach is a preset-based back-end output compression system, modulating a multi-channel transfer function depending on the intensity and information content of input sounds. Twenty adult CI patients, matched for age and CI experience, were included in this study. Pure-tone thresholds and vocal audiometry scores were measured with their former signal processing strategy and with xDP. Speech perception was assessed using dissyllabic words presented in quiet, at different intensity levels: 40, 55, 70, and 85 dB SPL, and in a cocktail party noise at a signal-to-noise ratio of +10 dB. Results with the xDP strategy showed, as awaited, no major modification of pure-tone thresholds. A global increase of speech perception scores was observed after a 1-month habituation period, with significant improvements for speech perception in quiet for moderate (55 dB SPL), loud speech sounds (85 dB SPL), and speech-in-noise comprehension. Subjective signal quality assessment showed a preference for CrystalisxDP over the former strategy. These results allow the quantification of improvements provided by the xDP signal processing strategy.
Literatur
1.
Zurück zum Zitat Blamey PJ, Maat B, Başkent D, Mawman D, Burke E, Dillier N, Beynon A, Kleine-Punte A, Govaerts PJ, Skarzynski PH, Huber AM, Sterkers-Artières F, Van de Heyning P, O’Leary S, Fraysse B, Green K, Sterkers O, Venail F, Skarzynski H, Vincent C, Truy E, Dowell R, Bergeron F, Lazard DS (2015) A retrospective Multicenter Study comparing Speech Perception Outcomes for Bilateral Implantation and Bimodal rehabilitation. Ear Hear [Epub ahead of print] Blamey PJ, Maat B, Başkent D, Mawman D, Burke E, Dillier N, Beynon A, Kleine-Punte A, Govaerts PJ, Skarzynski PH, Huber AM, Sterkers-Artières F, Van de Heyning P, O’Leary S, Fraysse B, Green K, Sterkers O, Venail F, Skarzynski H, Vincent C, Truy E, Dowell R, Bergeron F, Lazard DS (2015) A retrospective Multicenter Study comparing Speech Perception Outcomes for Bilateral Implantation and Bimodal rehabilitation. Ear Hear [Epub ahead of print]
2.
Zurück zum Zitat Lazard DS, Vincent C, Venail F, Van de Heyning P, Truy E, Sterkers O, Skarzynski PH, Skarzynski H, Schauwers K, O’Leary S, Mawman D, Maat B, Kleine-Punte A, Huber AM, Green K, Govaerts PJ, Fraysse B, Dowell R, Dillier N, Burke E, Beynon A, Bergeron F, Başkent D, Artières F, Blamey PJ (2012) Pre-, per- and postoperative factors affecting performance of postlinguistically deaf adults using cochlear implants: a new conceptual model over time. PLoS One 7(11):e48739. doi:10.1371/journal.pone.0048739 CrossRefPubMedPubMedCentral Lazard DS, Vincent C, Venail F, Van de Heyning P, Truy E, Sterkers O, Skarzynski PH, Skarzynski H, Schauwers K, O’Leary S, Mawman D, Maat B, Kleine-Punte A, Huber AM, Green K, Govaerts PJ, Fraysse B, Dowell R, Dillier N, Burke E, Beynon A, Bergeron F, Başkent D, Artières F, Blamey PJ (2012) Pre-, per- and postoperative factors affecting performance of postlinguistically deaf adults using cochlear implants: a new conceptual model over time. PLoS One 7(11):e48739. doi:10.​1371/​journal.​pone.​0048739 CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Sarant JZ, Holt CM, Dowell RC, Rickards FW, Blamey PJ (2009) Spoken language development in oral preschool children with permanent childhood deafness. J Deaf Stud Deaf Educ 14(2):205–217. doi:10.1093/deafed/enn034 CrossRefPubMed Sarant JZ, Holt CM, Dowell RC, Rickards FW, Blamey PJ (2009) Spoken language development in oral preschool children with permanent childhood deafness. J Deaf Stud Deaf Educ 14(2):205–217. doi:10.​1093/​deafed/​enn034 CrossRefPubMed
4.
Zurück zum Zitat Bond M, Mealing S, Anderson R, Elston J, Weiner G, Taylor RS, Hoyle M, Liu Z, Price A, Stein K (2009) The effectiveness and cost-effectiveness of cochlear implants for severe to profound deafness in children and adults: a systematic review and economic model. Health Technol Assess 13(44):1–330. doi:10.3310/hta13440 CrossRef Bond M, Mealing S, Anderson R, Elston J, Weiner G, Taylor RS, Hoyle M, Liu Z, Price A, Stein K (2009) The effectiveness and cost-effectiveness of cochlear implants for severe to profound deafness in children and adults: a systematic review and economic model. Health Technol Assess 13(44):1–330. doi:10.​3310/​hta13440 CrossRef
5.
Zurück zum Zitat Skinner MW, Holden LK, Holden TA, Demorest ME, Fourakis MS (1997) Speech recognition at simulated soft, conversational and raised-to-loud vocal efforts by adults with cochlear implants. J Acoust Soc Am 101(6):3766–3782CrossRefPubMed Skinner MW, Holden LK, Holden TA, Demorest ME, Fourakis MS (1997) Speech recognition at simulated soft, conversational and raised-to-loud vocal efforts by adults with cochlear implants. J Acoust Soc Am 101(6):3766–3782CrossRefPubMed
6.
Zurück zum Zitat Zeng FG, Galvin JJ (1999) Amplitude compression and phoneme recognition in cochlear implant listeners. Ear Hear 20(1):60–74CrossRefPubMed Zeng FG, Galvin JJ (1999) Amplitude compression and phoneme recognition in cochlear implant listeners. Ear Hear 20(1):60–74CrossRefPubMed
7.
Zurück zum Zitat Hornsby BW, Ricketts TA (2001) The effects of compression ratio, signal-to-noise ratio, and level on speech recognition in normal-hearing listeners. J Acoust Soc Am 109(6):2964–2973CrossRefPubMed Hornsby BW, Ricketts TA (2001) The effects of compression ratio, signal-to-noise ratio, and level on speech recognition in normal-hearing listeners. J Acoust Soc Am 109(6):2964–2973CrossRefPubMed
8.
Zurück zum Zitat Neuman AC, Bakke MH, Hellman S, Levitt H (1994) Effect of compression ratio in a slow-acting compression hearing aid: paired-comparison judgments of sound quality. J Acoust Soc Am 96(3):1471–1478CrossRefPubMed Neuman AC, Bakke MH, Hellman S, Levitt H (1994) Effect of compression ratio in a slow-acting compression hearing aid: paired-comparison judgments of sound quality. J Acoust Soc Am 96(3):1471–1478CrossRefPubMed
9.
Zurück zum Zitat Neuman AC, Bakke MH, Mackersie C, Hellman S, Levitt H (1998) The effect of compression ratio and release time on the categorical rating of sound quality. J Acoust Soc Am 103(5 Pt 1):2273–2281CrossRefPubMed Neuman AC, Bakke MH, Mackersie C, Hellman S, Levitt H (1998) The effect of compression ratio and release time on the categorical rating of sound quality. J Acoust Soc Am 103(5 Pt 1):2273–2281CrossRefPubMed
10.
Zurück zum Zitat Beranek LL (1947) The design of speech communication systems. Proc Inst Radio Eng 35:880–890 Beranek LL (1947) The design of speech communication systems. Proc Inst Radio Eng 35:880–890
11.
Zurück zum Zitat Dunn HK, White SD (1940) Statistical measurements on conversational speech. J Acoust Soc Am 11:278–288CrossRef Dunn HK, White SD (1940) Statistical measurements on conversational speech. J Acoust Soc Am 11:278–288CrossRef
12.
Zurück zum Zitat Fletcher H (1953) Speech and Hearing in Communication. Van Nostrand, Princeton Fletcher H (1953) Speech and Hearing in Communication. Van Nostrand, Princeton
13.
Zurück zum Zitat Zeng FG, Grant G, Niparko J, Galvin J, Shannon R, Opie J, Segel P (2002) Speech dynamic range and its effect on cochlear implant performance. J Acoust Soc Am 111(1 Pt 1):377–386CrossRefPubMed Zeng FG, Grant G, Niparko J, Galvin J, Shannon R, Opie J, Segel P (2002) Speech dynamic range and its effect on cochlear implant performance. J Acoust Soc Am 111(1 Pt 1):377–386CrossRefPubMed
14.
Zurück zum Zitat Loizou PC (1998) Mimicking the human ear. IEEE Signal Proc Mag 15(5):101–130CrossRef Loizou PC (1998) Mimicking the human ear. IEEE Signal Proc Mag 15(5):101–130CrossRef
15.
Zurück zum Zitat Van Hoesel R, Ramsden R, Odriscoll M (2002) Sound-direction identification, interaural time delay discrimination, and speech intelligibility advantages in noise for a bilateral cochlear implant user. Ear Hear 23(2):137–149CrossRefPubMed Van Hoesel R, Ramsden R, Odriscoll M (2002) Sound-direction identification, interaural time delay discrimination, and speech intelligibility advantages in noise for a bilateral cochlear implant user. Ear Hear 23(2):137–149CrossRefPubMed
16.
Zurück zum Zitat Boyle PJ, Büchner A, Stone MA, Lenarz T, Moore BCJ (2009) Comparison of dual-time-constant and fast acting automatic gain control (AGC) systems in cochlear implants. Int J Audiol 48(4):211–221CrossRefPubMed Boyle PJ, Büchner A, Stone MA, Lenarz T, Moore BCJ (2009) Comparison of dual-time-constant and fast acting automatic gain control (AGC) systems in cochlear implants. Int J Audiol 48(4):211–221CrossRefPubMed
17.
Zurück zum Zitat Moore BCJ (2008) The choice of compression speed in hearing aids: theoretical and practical considerations and the role of individual differences. Trends Amp 12(2):103–112CrossRef Moore BCJ (2008) The choice of compression speed in hearing aids: theoretical and practical considerations and the role of individual differences. Trends Amp 12(2):103–112CrossRef
18.
Zurück zum Zitat Stone MA, Moore BCJ (2007) Quantifying the effects of fast-acting compression on the envelope of speech. J Acoust Soc Am 121(3):1654–1664CrossRefPubMed Stone MA, Moore BCJ (2007) Quantifying the effects of fast-acting compression on the envelope of speech. J Acoust Soc Am 121(3):1654–1664CrossRefPubMed
19.
Zurück zum Zitat Stone MA, Moore BCJ (2008) Effects of spectro-temporal modulation changes produced by multi-channel compression on Intelligibility in a competing-speech task. J Acoust Soc Am 123(2):1063–1076. doi:10.1121/1.2821969 CrossRefPubMed Stone MA, Moore BCJ (2008) Effects of spectro-temporal modulation changes produced by multi-channel compression on Intelligibility in a competing-speech task. J Acoust Soc Am 123(2):1063–1076. doi:10.​1121/​1.​2821969 CrossRefPubMed
20.
Zurück zum Zitat Spahr AJ, Dorman MF, Loiselle LH (2007) Performance of patients using different cochlear implant systems: effects of input dynamic range. Ear Hear 28(2):260–275CrossRefPubMed Spahr AJ, Dorman MF, Loiselle LH (2007) Performance of patients using different cochlear implant systems: effects of input dynamic range. Ear Hear 28(2):260–275CrossRefPubMed
21.
Zurück zum Zitat Cox RM, Matesich JS, Moore JN (1988) Distributions of short-term rms levels in conversational speech. J Acoust Soc Am 84(3):1100–1104CrossRefPubMed Cox RM, Matesich JS, Moore JN (1988) Distributions of short-term rms levels in conversational speech. J Acoust Soc Am 84(3):1100–1104CrossRefPubMed
22.
Zurück zum Zitat Pavlovic CV (1993) Problems in the prediction of speech recognition performance of normal-hearing and hearing-impaired individuals. In Studebaker GA, Hochberg I (eds) Acoustical factors affecting hearing aid performance, 2nd ed. Boston, pp 221–234 Pavlovic CV (1993) Problems in the prediction of speech recognition performance of normal-hearing and hearing-impaired individuals. In Studebaker GA, Hochberg I (eds) Acoustical factors affecting hearing aid performance, 2nd ed. Boston, pp 221–234
23.
Zurück zum Zitat Boothroyd A, Erickson FN, Medwetsky L (1994) The hearing aid input: a phonemic approach to assessing the spectral distribution of speech. Ear Hear 15(6):432–442CrossRefPubMed Boothroyd A, Erickson FN, Medwetsky L (1994) The hearing aid input: a phonemic approach to assessing the spectral distribution of speech. Ear Hear 15(6):432–442CrossRefPubMed
24.
Zurück zum Zitat Stobich B, Zierhofer CM, Hochmair ES (1999) Influence of automatic gain control parameter settings on speech understanding of cochlear implant users employing the continuous interleaved sampling strategy. Ear Hear 20(2):104–116CrossRefPubMed Stobich B, Zierhofer CM, Hochmair ES (1999) Influence of automatic gain control parameter settings on speech understanding of cochlear implant users employing the continuous interleaved sampling strategy. Ear Hear 20(2):104–116CrossRefPubMed
25.
Zurück zum Zitat Eddington D (1999) Speech processors for auditory prostheses. NIDCD Contract N01-DC-6-2100, Final Progress Report Eddington D (1999) Speech processors for auditory prostheses. NIDCD Contract N01-DC-6-2100, Final Progress Report
26.
Zurück zum Zitat Studebaker GA, Sherbecoe RL, McDaniel DM, Gwaltney CA (1999) Monosyllabic word recognition at higher-than-normal speech and noise levels. J Acoust Soc Am 105(4):2431–2444CrossRefPubMed Studebaker GA, Sherbecoe RL, McDaniel DM, Gwaltney CA (1999) Monosyllabic word recognition at higher-than-normal speech and noise levels. J Acoust Soc Am 105(4):2431–2444CrossRefPubMed
28.
Zurück zum Zitat Moore BC, Glasberg BR (1988) A comparison of four methods of implementing automatic gain control (AGC) in hearing aids. Br J Audiol 22(2):93–104CrossRefPubMed Moore BC, Glasberg BR (1988) A comparison of four methods of implementing automatic gain control (AGC) in hearing aids. Br J Audiol 22(2):93–104CrossRefPubMed
29.
Zurück zum Zitat Léger AC, Moore BC, Gnansia D, Lorenzi C (2012) Effects of spectral smearing on the identification of speech in noise filtered into low- and mid-frequency regions. J Acoust Soc Am 131(5):4114–4123. doi:10.1121/1.3699265 CrossRefPubMed Léger AC, Moore BC, Gnansia D, Lorenzi C (2012) Effects of spectral smearing on the identification of speech in noise filtered into low- and mid-frequency regions. J Acoust Soc Am 131(5):4114–4123. doi:10.​1121/​1.​3699265 CrossRefPubMed
30.
Zurück zum Zitat Studebaker GA (1985) A “rationalized” arcsine transform. J Speech Hear Res 28(3):455–462CrossRefPubMed Studebaker GA (1985) A “rationalized” arcsine transform. J Speech Hear Res 28(3):455–462CrossRefPubMed
31.
Zurück zum Zitat Studebaker GA, McDaniel DM, Sherbecoe RL (1995) Evaluating relative speech recognition performance using the proficiency factor and rationalized arcsine differences. J Am Acad Audiol 6(2):173–182PubMed Studebaker GA, McDaniel DM, Sherbecoe RL (1995) Evaluating relative speech recognition performance using the proficiency factor and rationalized arcsine differences. J Am Acad Audiol 6(2):173–182PubMed
32.
Zurück zum Zitat Lorenzi C, Sibellas J, Füllgrabe C, Gallégo S, Fugain C, Meyer B (2004) Effects of amplitude compression on first- and second-order modulation detection thresholds in cochlear implant listeners. Int J Audiol 43(5):264–270CrossRefPubMed Lorenzi C, Sibellas J, Füllgrabe C, Gallégo S, Fugain C, Meyer B (2004) Effects of amplitude compression on first- and second-order modulation detection thresholds in cochlear implant listeners. Int J Audiol 43(5):264–270CrossRefPubMed
Metadaten
Titel
Clinical evaluation of the xDP output compression strategy for cochlear implants
verfasst von
Alexis Bozorg-Grayeli
Nicolas Guevara
Jean-Pierre Bebear
Marine Ardoint
Sonia Saaï
Michel Hoen
Dan Gnansia
Philippe Romanet
Jean-Pierre Lavieille
Publikationsdatum
17.10.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Archives of Oto-Rhino-Laryngology / Ausgabe 9/2016
Print ISSN: 0937-4477
Elektronische ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-015-3796-1

Weitere Artikel der Ausgabe 9/2016

European Archives of Oto-Rhino-Laryngology 9/2016 Zur Ausgabe

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

HNO-Op. auch mit über 90?

16.04.2024 HNO-Chirurgie Nachrichten

Mit Blick auf das Risiko für Komplikationen nach elektiven Eingriffen im HNO-Bereich scheint das Alter der Patienten kein ausschlaggebender Faktor zu sein. Entscheidend ist offenbar, wie fit die Betroffenen tatsächlich sind.

Intrakapsuläre Tonsillektomie gewinnt an Boden

16.04.2024 Tonsillektomie Nachrichten

Gegenüber der vollständigen Entfernung der Gaumenmandeln hat die intrakapsuläre Tonsillektomie einige Vorteile, wie HNO-Fachleute aus den USA hervorheben. Sie haben die aktuelle Literatur zu dem Verfahren gesichtet.

Bilateraler Hörsturz hat eine schlechte Prognose

15.04.2024 Hörsturz Nachrichten

Die Mehrzahl der Menschen mit Hörsturz ist einseitig betroffen, doch auch ein beidseitiger Hörsturz ist möglich. Wie häufig solche Fälle sind und wie sich ihr Verlauf darstellt, hat eine HNO-Expertenrunde aus den USA untersucht.

Update HNO

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.