Skip to main content
Erschienen in: Journal of Anesthesia 6/2011

01.12.2011 | Original Article

Assessment of cardiac preload status by pulse pressure variation in patients after anesthesia induction: comparison with central venous pressure and initial distribution volume of glucose

verfasst von: Zhiyong He, Hui Qiao, Wei Zhou, Yun Wang, Zhendong Xu, Xuehua Che, Jun Zhang, Weimin Liang

Erschienen in: Journal of Anesthesia | Ausgabe 6/2011

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Recognition of intraoperative hypovolemia is important for fluid management. Previous studies demonstrated functional preload parameter pulse pressure variation (PPV) could predict volume changes in response to fluid loading and loss. In this study, we examined the correlation between PPV and other two cardiac preload indicators, central venous pressure (CVP) or initial distribution volume of glucose (IDVG), in patients after anesthesia induction.

Methods

In 30 patients undergoing scheduled craniotomy surgery, we compared measurement of PPV (%) using the Ohmeda monitor method to simultaneously measure CVP and IDVG after anesthesia induction through correlation analysis and receiver operating characteristic (ROC) curves.

Results

Pulse pressure variation has negative linear correlation with IDVG (r = −0.65, P < 0.01). IDVG values (n = 13) when PPV ≥ 11% showed a significant difference compared with those (n = 17) when PPV < 11% (P < 0.001). The ROC curve showed the best cutoff value of IDVG is 122 ml/kg, equivalent to the threshold of PPV (11%) for predicting fluid responsiveness. However, there is no significant correlation between CVP in normal ranges (4–9 mmHg) and PPV (r = −0.12, P > 0.05).

Conclusion

As an indicator of cardiac preload, PPV has a negative linear correlation with IDVG in patients after anesthesia induction. It does not correlate well with CVP in the normal range. Our results imply that an individual PPV, not CVP, is equivalent to IDVG in assessing volume status after induction.
Literatur
1.
Zurück zum Zitat Boldt J, Lenz M, Kumle B, Papsdorf M. Volume replacement strategies on intensive care units: results from a postal survey. Intensive Care Med. 1998;24:147–51.PubMedCrossRef Boldt J, Lenz M, Kumle B, Papsdorf M. Volume replacement strategies on intensive care units: results from a postal survey. Intensive Care Med. 1998;24:147–51.PubMedCrossRef
2.
Zurück zum Zitat Ishihara H, Suzuki A, Okawa H, Sakai I, Tsubo T, Matsuki A. The initial distribution volume of glucose rather than indocyanine green derived plasma volume is correlated with cardiac output following major surgery. Intensive Care Med. 2000;26:1441–8.PubMedCrossRef Ishihara H, Suzuki A, Okawa H, Sakai I, Tsubo T, Matsuki A. The initial distribution volume of glucose rather than indocyanine green derived plasma volume is correlated with cardiac output following major surgery. Intensive Care Med. 2000;26:1441–8.PubMedCrossRef
3.
Zurück zum Zitat Suzuki A, Ishihara H, Okawa H, Tsubo T, Matsuki A. Can initial distribution volume of glucose predict hypovolemic hypotension after radical surgery for esophageal cancer? Anesth Analg. 2001;92:1146–51.PubMedCrossRef Suzuki A, Ishihara H, Okawa H, Tsubo T, Matsuki A. Can initial distribution volume of glucose predict hypovolemic hypotension after radical surgery for esophageal cancer? Anesth Analg. 2001;92:1146–51.PubMedCrossRef
4.
Zurück zum Zitat Orban JC, Blasin-Chadoutaud A, Zolfaghari P, Ishihara H, Grimaud D, Ichai C. Hypovolaemic hypotension after abdominal aortic surgery is predicted by initial distribution volume of glucose. Eur J Anaesthesiol. 2010;27:364–8.PubMedCrossRef Orban JC, Blasin-Chadoutaud A, Zolfaghari P, Ishihara H, Grimaud D, Ichai C. Hypovolaemic hypotension after abdominal aortic surgery is predicted by initial distribution volume of glucose. Eur J Anaesthesiol. 2010;27:364–8.PubMedCrossRef
5.
Zurück zum Zitat Hofer CK, Müller SM, Furrer L, Klaghofer R, Genoni M, Zollinger A. Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest. 2005;128:848–54.PubMedCrossRef Hofer CK, Müller SM, Furrer L, Klaghofer R, Genoni M, Zollinger A. Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest. 2005;128:848–54.PubMedCrossRef
6.
Zurück zum Zitat Kramer A, Zygun D, Hawes H, Easton P, Ferland A. Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery. Chest. 2004;126:1563–8.PubMedCrossRef Kramer A, Zygun D, Hawes H, Easton P, Ferland A. Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery. Chest. 2004;126:1563–8.PubMedCrossRef
7.
Zurück zum Zitat Pestel GJ, Hiltebrand LB, Fukui K, Cohen D, Hager H, Kurz AM. Assessing intravascular volume by difference in pulse pressure in pigs submitted to graded hemorrhage. Shock. 2006;26:391–5.PubMedCrossRef Pestel GJ, Hiltebrand LB, Fukui K, Cohen D, Hager H, Kurz AM. Assessing intravascular volume by difference in pulse pressure in pigs submitted to graded hemorrhage. Shock. 2006;26:391–5.PubMedCrossRef
8.
Zurück zum Zitat Mutoh T, Ishikawa T, Nishino K, Yasui N. Evaluation of the FloTrac uncalibrated continuous cardiac output system for perioperative hemodynamic monitoring after subarachnoid hemorrhage. J Neurosurg Anesthesiol. 2009;21:218–25.PubMedCrossRef Mutoh T, Ishikawa T, Nishino K, Yasui N. Evaluation of the FloTrac uncalibrated continuous cardiac output system for perioperative hemodynamic monitoring after subarachnoid hemorrhage. J Neurosurg Anesthesiol. 2009;21:218–25.PubMedCrossRef
9.
Zurück zum Zitat Durga P, Jonnavittula N, Muthuchellappan R, Ramachandran G. Measurement of systolic pressure variation during graded volume loss using simple tools on Datex Ohmeda S/5 monitor. J Neurosurg Anesth. 2009;21:161–4.CrossRef Durga P, Jonnavittula N, Muthuchellappan R, Ramachandran G. Measurement of systolic pressure variation during graded volume loss using simple tools on Datex Ohmeda S/5 monitor. J Neurosurg Anesth. 2009;21:161–4.CrossRef
10.
Zurück zum Zitat Qiao H, Zhang J, Liang WM. Validity of pulse pressure and systolic blood pressure variation data obtained from a Datex Ohmeda S/5 monitor for predicting fluid responsiveness during surgery. J Neurosurg Anesthesiol. 2010;22:316–22.PubMedCrossRef Qiao H, Zhang J, Liang WM. Validity of pulse pressure and systolic blood pressure variation data obtained from a Datex Ohmeda S/5 monitor for predicting fluid responsiveness during surgery. J Neurosurg Anesthesiol. 2010;22:316–22.PubMedCrossRef
11.
Zurück zum Zitat Ishihara H, Shimodate Y, Koh H, Isozaki K, Tsubo T, Matsuki A. The initial distribution volume of glucose and cardiac output in the critically ill. Can J Anaesth. 1993;40:28–31.PubMedCrossRef Ishihara H, Shimodate Y, Koh H, Isozaki K, Tsubo T, Matsuki A. The initial distribution volume of glucose and cardiac output in the critically ill. Can J Anaesth. 1993;40:28–31.PubMedCrossRef
12.
Zurück zum Zitat Hirota K, Ishihara H, Tsubo T, Matsuki A. Estimation of the initial distribution volume of glucose by an incremental plasma glucose level at 3 min after i.v. glucose in humans. Br J Clin Pharmacol. 1999;47:361–4.PubMedCrossRef Hirota K, Ishihara H, Tsubo T, Matsuki A. Estimation of the initial distribution volume of glucose by an incremental plasma glucose level at 3 min after i.v. glucose in humans. Br J Clin Pharmacol. 1999;47:361–4.PubMedCrossRef
13.
Zurück zum Zitat Bamboat ZM, Bordeianou L. Perioperative fluid management. Clin Colon Rectal Surg. 2009;22:28–33.PubMedCrossRef Bamboat ZM, Bordeianou L. Perioperative fluid management. Clin Colon Rectal Surg. 2009;22:28–33.PubMedCrossRef
14.
Zurück zum Zitat Cannesson M. Arterial pressure variation and goal-directed fluid therapy. J Cardiothorac Vasc Anesth. 2010;24:487–97.PubMedCrossRef Cannesson M. Arterial pressure variation and goal-directed fluid therapy. J Cardiothorac Vasc Anesth. 2010;24:487–97.PubMedCrossRef
15.
Zurück zum Zitat Jacob M, Chappell D, Conzen P, Finsterer U, Rehm M. Blood volume is normal after pre-operative overnight fasting. Acta Anaesthesiol Scand. 2008;52:522–9.PubMedCrossRef Jacob M, Chappell D, Conzen P, Finsterer U, Rehm M. Blood volume is normal after pre-operative overnight fasting. Acta Anaesthesiol Scand. 2008;52:522–9.PubMedCrossRef
16.
Zurück zum Zitat Brock H, Rapf B, Necek S, Gabriel C, Peterlik C, Pölz W, Schimetta W, Bergmann H. Vergleichende untersuchungen zur postoperativen volumentherapie bei kardiochirurgischen patienten. Anaesthesist. 1995;44:486–92.PubMedCrossRef Brock H, Rapf B, Necek S, Gabriel C, Peterlik C, Pölz W, Schimetta W, Bergmann H. Vergleichende untersuchungen zur postoperativen volumentherapie bei kardiochirurgischen patienten. Anaesthesist. 1995;44:486–92.PubMedCrossRef
17.
Zurück zum Zitat Shippy CR, Appel PL, Shoemaker WL. Reliability of clinical monitoring to assess blood volume in critically ill patients. Crit Care Med. 1984;12:107–12.PubMedCrossRef Shippy CR, Appel PL, Shoemaker WL. Reliability of clinical monitoring to assess blood volume in critically ill patients. Crit Care Med. 1984;12:107–12.PubMedCrossRef
18.
Zurück zum Zitat Sakka SG, Bredle DL, Reinhart K, Meier-Hellmann A. Comparison between intrathoracic blood volume and cardiac filling pressures in the early phase of hemodynamic instability of patients with septic shock. J Crit Care. 1999;14:78–83.PubMedCrossRef Sakka SG, Bredle DL, Reinhart K, Meier-Hellmann A. Comparison between intrathoracic blood volume and cardiac filling pressures in the early phase of hemodynamic instability of patients with septic shock. J Crit Care. 1999;14:78–83.PubMedCrossRef
19.
Zurück zum Zitat Kumar A, Anel R, Bunnell E, Habet K, Zanotti S, Marshall S, Neumann A, Ali A, Cheang M, Kavinsky C, Parrillo JE. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med. 2004;32:691–9.PubMedCrossRef Kumar A, Anel R, Bunnell E, Habet K, Zanotti S, Marshall S, Neumann A, Ali A, Cheang M, Kavinsky C, Parrillo JE. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med. 2004;32:691–9.PubMedCrossRef
20.
Zurück zum Zitat Marik PE. Techniques for assessment of intravascular volume in critically ill patients. J Intensive Care Med. 2009;24:329–37.PubMedCrossRef Marik PE. Techniques for assessment of intravascular volume in critically ill patients. J Intensive Care Med. 2009;24:329–37.PubMedCrossRef
21.
Zurück zum Zitat Cavallaro F, Sandroni C, Antonelli M. Functional hemodynamic monitoring and dynamic indices of fluid responsiveness. Minerva Anestesiol. 2008;74:123–35.PubMed Cavallaro F, Sandroni C, Antonelli M. Functional hemodynamic monitoring and dynamic indices of fluid responsiveness. Minerva Anestesiol. 2008;74:123–35.PubMed
22.
Zurück zum Zitat Wyffels PA, Sergeant P, Wouters PF. The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery. Anaesthesia. 2009;65:704–9.CrossRef Wyffels PA, Sergeant P, Wouters PF. The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery. Anaesthesia. 2009;65:704–9.CrossRef
23.
Zurück zum Zitat Biais M, Bernard O, Ha JC, Degryse C, Sztark F. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Br J Anaesth. 2010;104:407–13.PubMedCrossRef Biais M, Bernard O, Ha JC, Degryse C, Sztark F. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Br J Anaesth. 2010;104:407–13.PubMedCrossRef
24.
Zurück zum Zitat Bliacheriene F, Machado SB, Fonseca EB, Otsuke D, Auler JO Jr, Michard F. Pulse pressure variation as a tool to detect hypovolaemia during pneumoperitoneum. Acta Anaesthesiol Scand. 2007;51:1268–72.PubMed Bliacheriene F, Machado SB, Fonseca EB, Otsuke D, Auler JO Jr, Michard F. Pulse pressure variation as a tool to detect hypovolaemia during pneumoperitoneum. Acta Anaesthesiol Scand. 2007;51:1268–72.PubMed
25.
Zurück zum Zitat Kubitz JC, Forkl S, Annecke T, Kronas N, Goetz AE, Reuter DA. Systolic pressure variation and pulse pressure variation during modifications of arterial pressure. Intensive Care Med. 2008;34:1520–4.PubMedCrossRef Kubitz JC, Forkl S, Annecke T, Kronas N, Goetz AE, Reuter DA. Systolic pressure variation and pulse pressure variation during modifications of arterial pressure. Intensive Care Med. 2008;34:1520–4.PubMedCrossRef
26.
Zurück zum Zitat Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7.PubMedCrossRef Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7.PubMedCrossRef
27.
Zurück zum Zitat Fujita Y, Yamamoto T, Sano I, Yoshioka N, Hinenoya H. A comparison of changes in cardiac preload variables during graded hypovolemia and hypervolemia in mechanically ventilated dogs. Anesth Analg. 2004;99:1780–6.PubMedCrossRef Fujita Y, Yamamoto T, Sano I, Yoshioka N, Hinenoya H. A comparison of changes in cardiac preload variables during graded hypovolemia and hypervolemia in mechanically ventilated dogs. Anesth Analg. 2004;99:1780–6.PubMedCrossRef
28.
Zurück zum Zitat Cannesson M, Slieker J, Desebbe O, Bauer C, Chiari P, Hénaine R, Lehot JJ. The ability of a novel algorithm for automatic estimation of the respiratory variations in arterial pulse pressure to monitor fluid responsiveness in the operating room. Anesth Analg. 2008;106:1195–200.PubMedCrossRef Cannesson M, Slieker J, Desebbe O, Bauer C, Chiari P, Hénaine R, Lehot JJ. The ability of a novel algorithm for automatic estimation of the respiratory variations in arterial pulse pressure to monitor fluid responsiveness in the operating room. Anesth Analg. 2008;106:1195–200.PubMedCrossRef
29.
Zurück zum Zitat Umbrello M, Formenti P, Galimberti A, Curti M, Zaniboni M, Iapichino G. On-line measurement of systolic pressure variation and pulse pressure variation on a multiparametric monitor. Intensive Care Med. 2008;34:386–7.PubMedCrossRef Umbrello M, Formenti P, Galimberti A, Curti M, Zaniboni M, Iapichino G. On-line measurement of systolic pressure variation and pulse pressure variation on a multiparametric monitor. Intensive Care Med. 2008;34:386–7.PubMedCrossRef
30.
Zurück zum Zitat Deflandre E, Bonhomme V, Hans P. Delta down compared with delta pulse pressure as an indicator of volaemia during intracranial surgery. Br J Anaesth. 2008;100:245–50.PubMedCrossRef Deflandre E, Bonhomme V, Hans P. Delta down compared with delta pulse pressure as an indicator of volaemia during intracranial surgery. Br J Anaesth. 2008;100:245–50.PubMedCrossRef
31.
Zurück zum Zitat Ishihara H, Takamura K, Iwakawa T, Tsubo T, Matsuki A. Does the initial distribution of glucose reflect the central ECF volume status in critically ill patients? Infusionther Transfus Med. 1996;23:196–201.CrossRef Ishihara H, Takamura K, Iwakawa T, Tsubo T, Matsuki A. Does the initial distribution of glucose reflect the central ECF volume status in critically ill patients? Infusionther Transfus Med. 1996;23:196–201.CrossRef
32.
Zurück zum Zitat Gabbanelli V, Pantanetti S, Donati A, Montozzi A, Carbini C, Pelaia P. Initial distribution volume of glucose as noninvasive indicator of cardiac preload: comparison with intrathoracic blood volume. Intensive Care Med. 2004;30:2067–73.PubMedCrossRef Gabbanelli V, Pantanetti S, Donati A, Montozzi A, Carbini C, Pelaia P. Initial distribution volume of glucose as noninvasive indicator of cardiac preload: comparison with intrathoracic blood volume. Intensive Care Med. 2004;30:2067–73.PubMedCrossRef
33.
Zurück zum Zitat Nakamura H, Ishihara H, Okawa H, Yatsu Y, Tsubo T, Matsuki A. Initial distribution volume of glucose is correlated with intrathoracic blood volume in hypovolaemia and following volume loading in dogs. Eur J Anaesthesiol. 2005;22:202–8.PubMed Nakamura H, Ishihara H, Okawa H, Yatsu Y, Tsubo T, Matsuki A. Initial distribution volume of glucose is correlated with intrathoracic blood volume in hypovolaemia and following volume loading in dogs. Eur J Anaesthesiol. 2005;22:202–8.PubMed
34.
Zurück zum Zitat Ishihara H, Nakamura H, Okawa H, Yatsu Y, Tsubo T, Hirota K. Comparison of initial distribution volume of glucose and intrathoracic blood volume during hemodynamically unstable states early after esophagectomy. Chest. 2005;128:1713–9.PubMedCrossRef Ishihara H, Nakamura H, Okawa H, Yatsu Y, Tsubo T, Hirota K. Comparison of initial distribution volume of glucose and intrathoracic blood volume during hemodynamically unstable states early after esophagectomy. Chest. 2005;128:1713–9.PubMedCrossRef
35.
Zurück zum Zitat Harvey M, Voss L, Sleigh J. Preload response in patients after cardiac surgery: a comparison of systolic blood pressure and systolic area variability and initial volume of distribution of glucose. Crit Care Resusc. 2003;5:171–6.PubMed Harvey M, Voss L, Sleigh J. Preload response in patients after cardiac surgery: a comparison of systolic blood pressure and systolic area variability and initial volume of distribution of glucose. Crit Care Resusc. 2003;5:171–6.PubMed
36.
Zurück zum Zitat Ishihara H. Initial distribution volume of glucose early after cardiac surgery. Anesth Analg. 2006;102:1904.PubMedCrossRef Ishihara H. Initial distribution volume of glucose early after cardiac surgery. Anesth Analg. 2006;102:1904.PubMedCrossRef
37.
38.
Zurück zum Zitat Haruna M, Kumon K, Yahagi N, Watanabe Y, Ishida Y, Kobayashi N, Aoyagi T. Blood volume measurement at the bedside using ICG pulse spectrophotometry. Anesthesiology. 1998;89:1322–8.PubMedCrossRef Haruna M, Kumon K, Yahagi N, Watanabe Y, Ishida Y, Kobayashi N, Aoyagi T. Blood volume measurement at the bedside using ICG pulse spectrophotometry. Anesthesiology. 1998;89:1322–8.PubMedCrossRef
39.
Zurück zum Zitat van Tulder L, Michaeli B, Chioléro R, Berger MM, Revelly JP. An evaluation of the initial distribution volume of glucose to assess plasma volume during a fluid challenge. Anesth Analg. 2005;101:1089–93.PubMedCrossRef van Tulder L, Michaeli B, Chioléro R, Berger MM, Revelly JP. An evaluation of the initial distribution volume of glucose to assess plasma volume during a fluid challenge. Anesth Analg. 2005;101:1089–93.PubMedCrossRef
40.
Zurück zum Zitat Rose BO, Ishihara H, Okawa H, Panning B, Piepenbrock S, Matsuki A. Repeatability of measurements of the initial distribution volume of glucose in haemodynamically stable patients. J Clin Pharm Ther. 2004;29:317–23.PubMedCrossRef Rose BO, Ishihara H, Okawa H, Panning B, Piepenbrock S, Matsuki A. Repeatability of measurements of the initial distribution volume of glucose in haemodynamically stable patients. J Clin Pharm Ther. 2004;29:317–23.PubMedCrossRef
Metadaten
Titel
Assessment of cardiac preload status by pulse pressure variation in patients after anesthesia induction: comparison with central venous pressure and initial distribution volume of glucose
verfasst von
Zhiyong He
Hui Qiao
Wei Zhou
Yun Wang
Zhendong Xu
Xuehua Che
Jun Zhang
Weimin Liang
Publikationsdatum
01.12.2011
Verlag
Springer Japan
Erschienen in
Journal of Anesthesia / Ausgabe 6/2011
Print ISSN: 0913-8668
Elektronische ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-011-1225-1

Weitere Artikel der Ausgabe 6/2011

Journal of Anesthesia 6/2011 Zur Ausgabe

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.