UMMPerfusion: an Open Source Software Tool Towards Quantitative MRI Perfusion Analysis in Clinical Routine

verfasst von: Frank G. Zöllner, Gerald Weisser, Marcel Reich, Sven Kaiser, Stefan O. Schoenberg, Steven P. Sourbron, Lothar R. Schad

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 2/2013

Einloggen, um Zugang zu erhalten

Abstract

To develop a generic Open Source MRI perfusion analysis tool for quantitative parameter mapping to be used in a clinical workflow and methods for quality management of perfusion data. We implemented a classic, pixel-by-pixel deconvolution approach to quantify T1-weighted contrast-enhanced dynamic MR imaging (DCE-MRI) perfusion data as an OsiriX plug-in. It features parallel computing capabilities and an automated reporting scheme for quality management. Furthermore, by our implementation design, it could be easily extendable to other perfusion algorithms. Obtained results are saved as DICOM objects and directly added to the patient study. The plug-in was evaluated on ten MR perfusion data sets of the prostate and a calibration data set by comparing obtained parametric maps (plasma flow, volume of distribution, and mean transit time) to a widely used reference implementation in IDL. For all data, parametric maps could be calculated and the plug-in worked correctly and stable. On average, a deviation of 0.032 ± 0.02 ml/100 ml/min for the plasma flow, 0.004 ± 0.0007 ml/100 ml for the volume of distribution, and 0.037 ± 0.03 s for the mean transit time between our implementation and a reference implementation was observed. By using computer hardware with eight CPU cores, calculation time could be reduced by a factor of 2.5. We developed successfully an Open Source OsiriX plug-in for T1-DCE-MRI perfusion analysis in a routine quality managed clinical environment. Using model-free deconvolution, it allows for perfusion analysis in various clinical applications. By our plug-in, information about measured physiological processes can be obtained and transferred into clinical practice.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Thng CH, Koh TS, Collins DJ, Koh DM: Perfusion magnetic resonance imaging of the liver. World J Gastroenterol 16:1598–1609, 2010PubMedCrossRef Thng CH, Koh TS, Collins DJ, Koh DM: Perfusion magnetic resonance imaging of the liver. World J Gastroenterol 16:1598–1609, 2010PubMedCrossRef
2.
Zurück zum Zitat Scherr MK, Seitz M, Muller-Lisse UG, Ingrisch M, Reiser MF, Muller-Lisse UL: MR-perfusion (MRP) and diffusion-weighted imaging (DWI) in prostate cancer: quantitative and model-based gadobenate dimeglumine MRP parameters in detection of prostate cancer. Eur J Radiol 76:359–366, 2010PubMedCrossRef Scherr MK, Seitz M, Muller-Lisse UG, Ingrisch M, Reiser MF, Muller-Lisse UL: MR-perfusion (MRP) and diffusion-weighted imaging (DWI) in prostate cancer: quantitative and model-based gadobenate dimeglumine MRP parameters in detection of prostate cancer. Eur J Radiol 76:359–366, 2010PubMedCrossRef
3.
Zurück zum Zitat Attenberger UI, et al: Comprehensive MR evaluation of renal disease: added clinical value of quantified renal perfusion values over single MR angiography. J Magn Reson Imaging 31:125–133, 2010PubMedCrossRef Attenberger UI, et al: Comprehensive MR evaluation of renal disease: added clinical value of quantified renal perfusion values over single MR angiography. J Magn Reson Imaging 31:125–133, 2010PubMedCrossRef
4.
Zurück zum Zitat Bokacheva L, Rusinek H, Zhang JL, Lee VS: Assessment of renal function with dynamic contrast-enhanced MR imaging. Magn Reson Imaging Clin N Am 16:597–611, 2008. viiiPubMedCrossRef Bokacheva L, Rusinek H, Zhang JL, Lee VS: Assessment of renal function with dynamic contrast-enhanced MR imaging. Magn Reson Imaging Clin N Am 16:597–611, 2008. viiiPubMedCrossRef
5.
Zurück zum Zitat Sourbron S: Compartmental modelling for magnetic resonance renography. Z Med Phys 20:101–114, 2010PubMedCrossRef Sourbron S: Compartmental modelling for magnetic resonance renography. Z Med Phys 20:101–114, 2010PubMedCrossRef
6.
Zurück zum Zitat Sourbron SP, Buckley DL: Tracer kinetic modelling in MRI: estimating perfusion and capillary permeability. Phys Med Biol 57:R1–R33, 2012PubMedCrossRef Sourbron SP, Buckley DL: Tracer kinetic modelling in MRI: estimating perfusion and capillary permeability. Phys Med Biol 57:R1–R33, 2012PubMedCrossRef
7.
Zurück zum Zitat Thompson G, Mills SJ, Stivaros SM, Jackson A: Imaging of brain tumors: perfusion/permeability. Neuroimaging Clin N Am 20:337–353, 2010PubMedCrossRef Thompson G, Mills SJ, Stivaros SM, Jackson A: Imaging of brain tumors: perfusion/permeability. Neuroimaging Clin N Am 20:337–353, 2010PubMedCrossRef
8.
Zurück zum Zitat Tofts PS, et al: Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols. J Magn Reson Imaging 10:223–232, 1999PubMedCrossRef Tofts PS, et al: Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols. J Magn Reson Imaging 10:223–232, 1999PubMedCrossRef
9.
Zurück zum Zitat Ostergaard L: Principles of cerebral perfusion imaging by bolus tracking. J Magn Reson Imaging 22:710–717, 2005PubMedCrossRef Ostergaard L: Principles of cerebral perfusion imaging by bolus tracking. J Magn Reson Imaging 22:710–717, 2005PubMedCrossRef
10.
Zurück zum Zitat Buckley DL, Shurrab AAE, Cheung CM, Jones AP, Mamtora H, Kalra PA: Measurement of single kidney function using dynamic contrast-enhanced MRI: comparison of two models in human subjects. J Magn Reson Imaging 24:1117–1123, 2006PubMedCrossRef Buckley DL, Shurrab AAE, Cheung CM, Jones AP, Mamtora H, Kalra PA: Measurement of single kidney function using dynamic contrast-enhanced MRI: comparison of two models in human subjects. J Magn Reson Imaging 24:1117–1123, 2006PubMedCrossRef
11.
Zurück zum Zitat Attenberger U, et al.: Clinical Value of MR-Based Quantification of Renal Perfusion Parameters with a Separable Two-Compartment Model. Proceedings 16th Scientific Meeting, International Society for Magnetic Resonance in Medicine, Toronto:3680, 2008 Attenberger U, et al.: Clinical Value of MR-Based Quantification of Renal Perfusion Parameters with a Separable Two-Compartment Model. Proceedings 16th Scientific Meeting, International Society for Magnetic Resonance in Medicine, Toronto:3680, 2008
12.
Zurück zum Zitat Miller WL, Hodge DO, Tointon SK, Rodeheffer RJ, Nelson SM, Gibbons RJ: Relationship of myocardial perfusion imaging findings to outcome of patients with heart failure and suspected ischemic heart disease. Am Heart J 147:714–720, 2004PubMedCrossRef Miller WL, Hodge DO, Tointon SK, Rodeheffer RJ, Nelson SM, Gibbons RJ: Relationship of myocardial perfusion imaging findings to outcome of patients with heart failure and suspected ischemic heart disease. Am Heart J 147:714–720, 2004PubMedCrossRef
13.
Zurück zum Zitat Futterer JJ, et al: Prostate cancer: local staging at 3-T endorectal MR imaging–early experience. Radiology 238:184–191, 2006PubMedCrossRef Futterer JJ, et al: Prostate cancer: local staging at 3-T endorectal MR imaging–early experience. Radiology 238:184–191, 2006PubMedCrossRef
14.
Zurück zum Zitat Futterer JJ, et al: Prostate cancer localization with dynamic contrast-enhanced MR imaging and proton MR spectroscopic imaging. Radiology 241:449–458, 2006PubMedCrossRef Futterer JJ, et al: Prostate cancer localization with dynamic contrast-enhanced MR imaging and proton MR spectroscopic imaging. Radiology 241:449–458, 2006PubMedCrossRef
15.
Zurück zum Zitat Litjens GJS, Vos PC, Barentsz JO, Karssemeijer N, Huisman HJ: Automatic computer aided detection of abnormalities in multi-parametric prostate MRI. SPIE, Orlando, 2011 Litjens GJS, Vos PC, Barentsz JO, Karssemeijer N, Huisman HJ: Automatic computer aided detection of abnormalities in multi-parametric prostate MRI. SPIE, Orlando, 2011
16.
Zurück zum Zitat Weidner AM, et al: Value of multiparametric prostate MRI of the peripheral zone. Z Med Phys 21:198–205, 2011PubMedCrossRef Weidner AM, et al: Value of multiparametric prostate MRI of the peripheral zone. Z Med Phys 21:198–205, 2011PubMedCrossRef
18.
Zurück zum Zitat Grenier N, et al: Measurement of glomerular filtration rate with magnetic resonance imaging: principles, limitations, and expectations. Semin Nucl Med 38:47–55, 2008PubMedCrossRef Grenier N, et al: Measurement of glomerular filtration rate with magnetic resonance imaging: principles, limitations, and expectations. Semin Nucl Med 38:47–55, 2008PubMedCrossRef
20.
Zurück zum Zitat Cutajar M, Mendichovszky IA, Tofts PS, Gordon I: The importance of AIF ROI selection in DCE-MRI renography: reproducibility and variability of renal perfusion and filtration. Eur J Radiol 74:e154–e160, 2010PubMedCrossRef Cutajar M, Mendichovszky IA, Tofts PS, Gordon I: The importance of AIF ROI selection in DCE-MRI renography: reproducibility and variability of renal perfusion and filtration. Eur J Radiol 74:e154–e160, 2010PubMedCrossRef
21.
Zurück zum Zitat Zöllner FG, et al: Assessment of 3D DCE-MRI of the kidneys using non-rigid image registration and segmentation of voxel time courses. Comput Med Imaging Graph 33:171–181, 2009PubMedCrossRef Zöllner FG, et al: Assessment of 3D DCE-MRI of the kidneys using non-rigid image registration and segmentation of voxel time courses. Comput Med Imaging Graph 33:171–181, 2009PubMedCrossRef
22.
Zurück zum Zitat Lietzmann F, Zöllner FG, Michaely HJ, Schad LR: Untersuchung von selbstnavigierenden MR-Sequenzen für die Perfusionsbildgebung der Nieren. Z Med Phys 20:124–133, 2010PubMedCrossRef Lietzmann F, Zöllner FG, Michaely HJ, Schad LR: Untersuchung von selbstnavigierenden MR-Sequenzen für die Perfusionsbildgebung der Nieren. Z Med Phys 20:124–133, 2010PubMedCrossRef
23.
Zurück zum Zitat Kosior JC, Frayne R: PerfTool: a software platform for investigating bolus-tracking perfusion imaging quantification strategies. J Magn Reson Imaging 25:653–659, 2007PubMedCrossRef Kosior JC, Frayne R: PerfTool: a software platform for investigating bolus-tracking perfusion imaging quantification strategies. J Magn Reson Imaging 25:653–659, 2007PubMedCrossRef
24.
Zurück zum Zitat Sourbron S, Biffar A, Ingrisch M, Fierens Y, Luypaert R: PMI: platform for research in medical imaging. Magn Reson Mater Phy 22:539, 2009 Sourbron S, Biffar A, Ingrisch M, Fierens Y, Luypaert R: PMI: platform for research in medical imaging. Magn Reson Mater Phy 22:539, 2009
25.
Zurück zum Zitat Wittsack HJ, Ritzl A, Modder U: User friendly analysis of MR investigations of the cerebral perfusion: Windows(R)-based image processing. Rofo 174:742–746, 2002PubMedCrossRef Wittsack HJ, Ritzl A, Modder U: User friendly analysis of MR investigations of the cerebral perfusion: Windows(R)-based image processing. Rofo 174:742–746, 2002PubMedCrossRef
26.
Zurück zum Zitat Ferl GZ: DATforDCEMRI: an R package for deconvolution analysis and visualization of DCE-MRI data. J Stat Softw 44:1–18, 2011 Ferl GZ: DATforDCEMRI: an R package for deconvolution analysis and visualization of DCE-MRI data. J Stat Softw 44:1–18, 2011
27.
Zurück zum Zitat Whitcher B, Schmid VJ: Quantitative analysis of dynamic contrast-enhanced and diffusion-weighted magnetic resonance imaging for oncology in R. J Stat Softw 44:1–29, 2011 Whitcher B, Schmid VJ: Quantitative analysis of dynamic contrast-enhanced and diffusion-weighted magnetic resonance imaging for oncology in R. J Stat Softw 44:1–29, 2011
28.
Zurück zum Zitat Puech P, Betrouni N, Makni N, Dewalle AS, Villers A, Lemaitre L: Computer-assisted diagnosis of prostate cancer using DCE-MRI data: design, implementation and preliminary results. Int J Comput Assist Radiol Surg 4:1–10, 2009PubMedCrossRef Puech P, Betrouni N, Makni N, Dewalle AS, Villers A, Lemaitre L: Computer-assisted diagnosis of prostate cancer using DCE-MRI data: design, implementation and preliminary results. Int J Comput Assist Radiol Surg 4:1–10, 2009PubMedCrossRef
29.
Zurück zum Zitat Caban JJ, Joshi A, Nagy P: Rapid development of medical imaging tools with open-source libraries. J Digit Imaging 20(Suppl 1):83–93, 2007PubMedCrossRef Caban JJ, Joshi A, Nagy P: Rapid development of medical imaging tools with open-source libraries. J Digit Imaging 20(Suppl 1):83–93, 2007PubMedCrossRef
30.
Zurück zum Zitat Sourbron S, Dujardin M, Makkat S, Luypaert R: Pixel-by-pixel deconvolution of bolus-tracking data: optimization and implementation. Phys Med Biol 52:429–447, 2007PubMedCrossRef Sourbron S, Dujardin M, Makkat S, Luypaert R: Pixel-by-pixel deconvolution of bolus-tracking data: optimization and implementation. Phys Med Biol 52:429–447, 2007PubMedCrossRef
31.
Zurück zum Zitat Østergaard L, Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR: High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: mathematical approach and statistical analysis. Magn Reson Med 36:715–725, 1996PubMedCrossRef Østergaard L, Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR: High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: mathematical approach and statistical analysis. Magn Reson Med 36:715–725, 1996PubMedCrossRef
32.
Zurück zum Zitat Sourbron S, Luypaert R, Morhard D, Seelos K, Reiser M, Peller M: Deconvolution of bolus-tracking data: a comparison of discretization methods. Phys Med Biol 52:6761–6778, 2007PubMedCrossRef Sourbron S, Luypaert R, Morhard D, Seelos K, Reiser M, Peller M: Deconvolution of bolus-tracking data: a comparison of discretization methods. Phys Med Biol 52:6761–6778, 2007PubMedCrossRef
33.
Zurück zum Zitat Rosset A, Spadola L, Ratib O: OsiriX: an open-source software for navigating in multidimensional DICOM images. J Digit Imaging 17:205–216, 2004PubMedCrossRef Rosset A, Spadola L, Ratib O: OsiriX: an open-source software for navigating in multidimensional DICOM images. J Digit Imaging 17:205–216, 2004PubMedCrossRef
34.
Zurück zum Zitat Jalbert F, Paoli JR: Osirix: free and open-source software for medical imagery. Rev Stomatol Chir 109:53–55, 2008CrossRef Jalbert F, Paoli JR: Osirix: free and open-source software for medical imagery. Rev Stomatol Chir 109:53–55, 2008CrossRef
35.
Zurück zum Zitat Rosset A, Spadola L, Pysher L, Ratib O: Informatics in radiology (infoRAD)—navigating the fifth dimension: innovative interface for multidimensional multimodality image navigation. Radiographics 26:299–308, 2006PubMedCrossRef Rosset A, Spadola L, Pysher L, Ratib O: Informatics in radiology (infoRAD)—navigating the fifth dimension: innovative interface for multidimensional multimodality image navigation. Radiographics 26:299–308, 2006PubMedCrossRef
37.
Zurück zum Zitat Ratib O, Rosset A, Heuberger J: Open Source software and social networks: disruptive alternatives for medical imaging. Eur J Radiol 78:259–265, 2011PubMedCrossRef Ratib O, Rosset A, Heuberger J: Open Source software and social networks: disruptive alternatives for medical imaging. Eur J Radiol 78:259–265, 2011PubMedCrossRef
38.
Zurück zum Zitat Vetter S: Optimising an OsiriX Plug-in for Perfusion Analysis of MR Images Applied University Mannheim, Faculty of Computer Science, Bachelor of Science, Bachelor’s Thesis (24.9.2010 2010) Vetter S: Optimising an OsiriX Plug-in for Perfusion Analysis of MR Images Applied University Mannheim, Faculty of Computer Science, Bachelor of Science, Bachelor’s Thesis (24.9.2010 2010)
40.
Zurück zum Zitat Weidenhagen R, Meirnarakis G, Jauch KW, Becker CR, Kopp R: OsiriX. An open-source solution for planning aorta stent grafts. Gefässchirurgie 13:278–290, 2008CrossRef Weidenhagen R, Meirnarakis G, Jauch KW, Becker CR, Kopp R: OsiriX. An open-source solution for planning aorta stent grafts. Gefässchirurgie 13:278–290, 2008CrossRef
41.
Zurück zum Zitat Yamauchi T, et al: Efficacy and reliability of highly functional open source DICOM software (OsiriX) in spine surgery. J Clin Neurosci 17:756–759, 2010PubMedCrossRef Yamauchi T, et al: Efficacy and reliability of highly functional open source DICOM software (OsiriX) in spine surgery. J Clin Neurosci 17:756–759, 2010PubMedCrossRef
42.
Zurück zum Zitat Calamante F, Gadian DG, Connelly A: Quantification of perfusion using bolus tracking magnetic resonance imaging in stroke: assumptions, limitations, and potential implications for clinical use. Stroke 33:1146–1151, 2002PubMedCrossRef Calamante F, Gadian DG, Connelly A: Quantification of perfusion using bolus tracking magnetic resonance imaging in stroke: assumptions, limitations, and potential implications for clinical use. Stroke 33:1146–1151, 2002PubMedCrossRef
43.
Zurück zum Zitat Jerosch-Herold M, Seethamraju RT, Swingen CM, Wilke NM, Stillman AE: Analysis of myocardial perfusion MRI. J Magn Reson Imaging 19:758–770, 2004PubMedCrossRef Jerosch-Herold M, Seethamraju RT, Swingen CM, Wilke NM, Stillman AE: Analysis of myocardial perfusion MRI. J Magn Reson Imaging 19:758–770, 2004PubMedCrossRef
44.
Zurück zum Zitat Ali B, Hsiao E, Di Carli MF: Combined anatomic and perfusion imaging of the heart. Curr Cardiol Rep 12:90–97, 2010PubMedCrossRef Ali B, Hsiao E, Di Carli MF: Combined anatomic and perfusion imaging of the heart. Curr Cardiol Rep 12:90–97, 2010PubMedCrossRef
45.
Zurück zum Zitat Ohno Y, et al: Primary pulmonary hypertension: 3D dynamic perfusion MRI for quantitative analysis of regional pulmonary perfusion. AJR Am J Roentgenol 188:48–56, 2007PubMedCrossRef Ohno Y, et al: Primary pulmonary hypertension: 3D dynamic perfusion MRI for quantitative analysis of regional pulmonary perfusion. AJR Am J Roentgenol 188:48–56, 2007PubMedCrossRef
46.
Zurück zum Zitat Zöllner FG, Zahn K, Schaible T, Schoenberg SO, Schad LR, Neff KW: Quantitative pulmonary perfusion imaging at 3.0 T of 2-year-old children after congenital diaphragmatic hernia repair: initial results. Eur Radiol, 2012. doi:10.1007/s00330-012-2528-9 Zöllner FG, Zahn K, Schaible T, Schoenberg SO, Schad LR, Neff KW: Quantitative pulmonary perfusion imaging at 3.0 T of 2-year-old children after congenital diaphragmatic hernia repair: initial results. Eur Radiol, 2012. doi:10.​1007/​s00330-012-2528-9
47.
Zurück zum Zitat Makkat S, Luypaert R, Sourbron S, Stadnik T, De Mey J: Quantification of perfusion and permeability in breast tumors with a deconvolution-based analysis of second-bolus T1-DCE data. J Magn Reson Imaging 25:1159–1167, 2007PubMedCrossRef Makkat S, Luypaert R, Sourbron S, Stadnik T, De Mey J: Quantification of perfusion and permeability in breast tumors with a deconvolution-based analysis of second-bolus T1-DCE data. J Magn Reson Imaging 25:1159–1167, 2007PubMedCrossRef
48.
Zurück zum Zitat Aumann S, et al: Quantification of renal perfusion using an intravascular contrast agent (part 1): results in a canine model. Magn Reson Med 49:276–287, 2003PubMedCrossRef Aumann S, et al: Quantification of renal perfusion using an intravascular contrast agent (part 1): results in a canine model. Magn Reson Med 49:276–287, 2003PubMedCrossRef
49.
Zurück zum Zitat Eastwood JD, et al: CT perfusion scanning with deconvolution analysis: pilot study in patients with acute middle cerebral artery stroke. Radiology 222:227–236, 2002PubMedCrossRef Eastwood JD, et al: CT perfusion scanning with deconvolution analysis: pilot study in patients with acute middle cerebral artery stroke. Radiology 222:227–236, 2002PubMedCrossRef
50.
Zurück zum Zitat Bisdas S, et al: A comparison of tumour perfusion assessed by deconvolution-based analysis of dynamic contrast-enhanced CT and MR imaging in patients with squamous cell carcinoma of the upper aerodigestive tract. Eur Radiol 18:843–850, 2008PubMedCrossRef Bisdas S, et al: A comparison of tumour perfusion assessed by deconvolution-based analysis of dynamic contrast-enhanced CT and MR imaging in patients with squamous cell carcinoma of the upper aerodigestive tract. Eur Radiol 18:843–850, 2008PubMedCrossRef
51.
Zurück zum Zitat Sourbron S, Ingrisch M, Siefert A, Reiser M, Herrmann K: Quantification of cerebral blood flow, cerebral blood volume, and blood–brain-barrier leakage with DCE-MRI. Magn Reson Med 62:205–217, 2009PubMedCrossRef Sourbron S, Ingrisch M, Siefert A, Reiser M, Herrmann K: Quantification of cerebral blood flow, cerebral blood volume, and blood–brain-barrier leakage with DCE-MRI. Magn Reson Med 62:205–217, 2009PubMedCrossRef
52.
Zurück zum Zitat Padhani AR: Dynamic contrast-enhanced MRI in clinical oncology: current status and future directions. J Magn Reson Imaging 16:407–422, 2002PubMedCrossRef Padhani AR: Dynamic contrast-enhanced MRI in clinical oncology: current status and future directions. J Magn Reson Imaging 16:407–422, 2002PubMedCrossRef
53.
Zurück zum Zitat Lietzmann F, Zöllner FG, Attenberger UI, Haneder S, Michaely HJ, Schad LR: DCE-MRI of the human kidney using BLADE: a feasibility study in healthy volunteers. J Magn Reson Imaging 35:868–874, 2011PubMedCrossRef Lietzmann F, Zöllner FG, Attenberger UI, Haneder S, Michaely HJ, Schad LR: DCE-MRI of the human kidney using BLADE: a feasibility study in healthy volunteers. J Magn Reson Imaging 35:868–874, 2011PubMedCrossRef
54.
Zurück zum Zitat Hansen PC: Rank-Deficient and Discrete Ill-Posed Problems: Numerical Aspects of Linear Inversion. SIAM, Philadelphia, 1998CrossRef Hansen PC: Rank-Deficient and Discrete Ill-Posed Problems: Numerical Aspects of Linear Inversion. SIAM, Philadelphia, 1998CrossRef
Metadaten
Titel
UMMPerfusion: an Open Source Software Tool Towards Quantitative MRI Perfusion Analysis in Clinical Routine
verfasst von
Frank G. Zöllner
Gerald Weisser
Marcel Reich
Sven Kaiser
Stefan O. Schoenberg
Steven P. Sourbron
Lothar R. Schad
Publikationsdatum
01.04.2013
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 2/2013
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-012-9510-6

Weitere Artikel der Ausgabe 2/2013

Journal of Digital Imaging 2/2013 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.