Abstract

Purpose

The assessment of intra-operatively acquired volumetric data is a difficult and often time-consuming task, which demands a new set of skills from the surgeons. In the case of orthopedic surgeries such as the treatment of calcaneal fractures, the correctness of the reduction of the bone fragments can be verified with the help of C-arm CT volumetric images. For an accurate intra-operative assessment of the displaced fragments, an automatic segmentation of the articular surfaces and color-coded visualization was developed.

Methods

Our automatic approach consists of three major steps: first, using adjusted standard planes intersecting the articular region, the joint space is localized with an intensity profile-based method. In a second step, the localized joint space is segmented on the Laplacian of Gaussian filtered volumetric image by a modified binary flood fill algorithm. Finally, a 3D surface model of the segmented joint space is analyzed and visualized with focus on critical displacements of the surface.

Results

A specifically designed human cadaver study consisting of ten lower legs of ten different donors was conducted to acquire 48 realistic C-arm CT images of misaligned bone fragments (steps of varying sizes) in the posterior talar articular surface of the calcaneus. The proposed algorithmic pipeline was verified by the acquired image data and showed very good results with no false positives and an overall correct displacement assessment of \(93.8\,\%\).

Conclusions

The proposed algorithmic pipeline can be easily integrated into the clinical workflow and qualifies for intra-operative usage. It showed very good results on the reference data set of the cadaver study. With the help of such an assistance system, the time-consuming process of 2D view adjustment and visual assessment of the gray value images can be greatly simplified.
Literatur
1.
Zurück zum Zitat Akhtar S, Poh C, Kitney R (2007) An MRI derived articular cartilage visualization framework. Osteoarthr Cartil 15(9):1070–1085CrossRefPubMed Akhtar S, Poh C, Kitney R (2007) An MRI derived articular cartilage visualization framework. Osteoarthr Cartil 15(9):1070–1085CrossRefPubMed
2.
Zurück zum Zitat Bahri N, Simon L, Gaida S, Schulz A, Fuchs S (2010) Impact of intraoperative 3d fluoroscopy scan in the surgical treatment of calcaneal fractures. J Bone Jt Surg Br Vol 92(SUPP II):349–349 Bahri N, Simon L, Gaida S, Schulz A, Fuchs S (2010) Impact of intraoperative 3d fluoroscopy scan in the surgical treatment of calcaneal fractures. J Bone Jt Surg Br Vol 92(SUPP II):349–349
3.
Zurück zum Zitat Brehler M, Görres J, Wolf I, Franke J, von Recum J, Grützner PA, Meinzer HP, Nabers D (2014) Automatic standard plane adjustment on mobile c-arm ct images of the calcaneus using atlas-based feature registration. In: Proc. SPIE 9036, medical imaging 2014, image-guided procedures, robotic interventions, and modeling, 90360E. doi:10.1109/CVPR.2001.990517 Brehler M, Görres J, Wolf I, Franke J, von Recum J, Grützner PA, Meinzer HP, Nabers D (2014) Automatic standard plane adjustment on mobile c-arm ct images of the calcaneus using atlas-based feature registration. In: Proc. SPIE 9036, medical imaging 2014, image-guided procedures, robotic interventions, and modeling, 90360E. doi:10.​1109/​CVPR.​2001.​990517
4.
Zurück zum Zitat Cao Q, Thawait G, Gang GJ, Zbijewski W, Reigel T, Brown T, Corner B, Demehri S, Siewerdsen JH (2015) Characterization of 3d joint space morphology using an electrostatic model (with application to osteoarthritis). Phys Med Biol 60(3):947CrossRefPubMedPubMedCentral Cao Q, Thawait G, Gang GJ, Zbijewski W, Reigel T, Brown T, Corner B, Demehri S, Siewerdsen JH (2015) Characterization of 3d joint space morphology using an electrostatic model (with application to osteoarthritis). Phys Med Biol 60(3):947CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Choi JH, McWalter EJ, Pal S, Maier A, Gold GE, Fahrig R (2013) Analysis of three-dimensional joint space of the tibiofemoral joint. In: Nuclear science symposium and medical imaging conference (NSS/MIC), 2013 IEEE, pp 1–4. IEEE Choi JH, McWalter EJ, Pal S, Maier A, Gold GE, Fahrig R (2013) Analysis of three-dimensional joint space of the tibiofemoral joint. In: Nuclear science symposium and medical imaging conference (NSS/MIC), 2013 IEEE, pp 1–4. IEEE
6.
Zurück zum Zitat Daly M, Siewerdsen J, Moseley D, Jaffray D, Irish J (2006) Intraoperative cone-beam ct for guidance of head and neck surgery: assessment of dose and image quality using a c-arm prototype. Med Phys 33(10):3767–3780CrossRefPubMed Daly M, Siewerdsen J, Moseley D, Jaffray D, Irish J (2006) Intraoperative cone-beam ct for guidance of head and neck surgery: assessment of dose and image quality using a c-arm prototype. Med Phys 33(10):3767–3780CrossRefPubMed
7.
Zurück zum Zitat Franke J, Wendl K, Suda AJ, Giese T, Grützner PA, von Recum J (2014) Intraoperative three-dimensional imaging in the treatment of calcaneal fractures. J Bone Jt Surg JBJS 96(9):e72. doi:10.2106/JBJS.L.01220 CrossRef Franke J, Wendl K, Suda AJ, Giese T, Grützner PA, von Recum J (2014) Intraoperative three-dimensional imaging in the treatment of calcaneal fractures. J Bone Jt Surg JBJS 96(9):e72. doi:10.​2106/​JBJS.​L.​01220 CrossRef
9.
Zurück zum Zitat Görres J, Brehler M, Franke J, Barth K, Vetter SY, Córdova A, Grützner PA, Meinzer HP, Wolf I, Nabers D (2014) Intraoperative detection and localization of cylindrical implants in cone-beam ct image data. Int J Comput Assist Radiol Surg 9:1–13CrossRef Görres J, Brehler M, Franke J, Barth K, Vetter SY, Córdova A, Grützner PA, Meinzer HP, Wolf I, Nabers D (2014) Intraoperative detection and localization of cylindrical implants in cone-beam ct image data. Int J Comput Assist Radiol Surg 9:1–13CrossRef
10.
Zurück zum Zitat Kalinosky B, Sabol JM, Piacsek K, Heckel B, Schmidt TG (2011) Quantifying the tibiofemoral joint space using x-ray tomosynthesis. Med Phys 38(12):6672–6682CrossRefPubMed Kalinosky B, Sabol JM, Piacsek K, Heckel B, Schmidt TG (2011) Quantifying the tibiofemoral joint space using x-ray tomosynthesis. Med Phys 38(12):6672–6682CrossRefPubMed
11.
Zurück zum Zitat Mehling I, Rittstieg P, Mehling A, Küchle R, Müller L, Rommens P (2013) Intraoperative c-arm ct imaging in angular stable plate osteosynthesis of distal radius fractures. J Hand Surg Eur Vol 38(7):751–757CrossRefPubMed Mehling I, Rittstieg P, Mehling A, Küchle R, Müller L, Rommens P (2013) Intraoperative c-arm ct imaging in angular stable plate osteosynthesis of distal radius fractures. J Hand Surg Eur Vol 38(7):751–757CrossRefPubMed
12.
Zurück zum Zitat Nolden M, Zelzer S, Seitel A, Wald D, Müller M, Franz AM, Maleike D, Fangerau M, Baumhauer M, Maier-Hein L, Maier-Hein KH, Meinzer HP, Wolf I (2013) The medical imaging interaction toolkit: challenges and advances. Int J Comput Assist Radiol Surg 8(4):607–620. doi:10.1007/s11548-013-0840-8 CrossRefPubMed Nolden M, Zelzer S, Seitel A, Wald D, Müller M, Franz AM, Maleike D, Fangerau M, Baumhauer M, Maier-Hein L, Maier-Hein KH, Meinzer HP, Wolf I (2013) The medical imaging interaction toolkit: challenges and advances. Int J Comput Assist Radiol Surg 8(4):607–620. doi:10.​1007/​s11548-013-0840-8 CrossRefPubMed
13.
Zurück zum Zitat Rockwood C, Bucholz R, Green D, Court-Brown C, Heckman J, Tornetta P (2010) Rockwood and Green’s fractures in adults. No. Bd. 1 in Fractures in Adults. Wolters Kluwer Health/Lippincott Williams & Wilkins, Philadelphia Rockwood C, Bucholz R, Green D, Court-Brown C, Heckman J, Tornetta P (2010) Rockwood and Green’s fractures in adults. No. Bd. 1 in Fractures in Adults. Wolters Kluwer Health/Lippincott Williams & Wilkins, Philadelphia
14.
Zurück zum Zitat Saxena A (2012) International advances in foot and ankle surgery. springer, New YorkCrossRef Saxena A (2012) International advances in foot and ankle surgery. springer, New YorkCrossRef
15.
Zurück zum Zitat Schafer S, Nithiananthan S, Mirota D, Uneri A, Stayman J, Zbijewski W, Schmidgunst C, Kleinszig G, Khanna A, Siewerdsen J (2011) mobile C-arm cone-beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance. Med Phys 38(8):4563–4574CrossRefPubMedPubMedCentral Schafer S, Nithiananthan S, Mirota D, Uneri A, Stayman J, Zbijewski W, Schmidgunst C, Kleinszig G, Khanna A, Siewerdsen J (2011) mobile C-arm cone-beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance. Med Phys 38(8):4563–4574CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Valette S, Chassery JM (2004) Approximated centroidal voronoi diagrams for uniform polygonal mesh coarsening. In: Computer graphics forum, vol. 23, pp 381–389. Wiley Online Library Valette S, Chassery JM (2004) Approximated centroidal voronoi diagrams for uniform polygonal mesh coarsening. In: Computer graphics forum, vol. 23, pp 381–389. Wiley Online Library
17.
Zurück zum Zitat Valette S, Chassery JM, Prost R (2008) Generic remeshing of 3d triangular meshes with metric-dependent discrete Voronoi diagrams. Vis Comput Graph IEEE Trans 14(2):369–381CrossRef Valette S, Chassery JM, Prost R (2008) Generic remeshing of 3d triangular meshes with metric-dependent discrete Voronoi diagrams. Vis Comput Graph IEEE Trans 14(2):369–381CrossRef
18.
Zurück zum Zitat Von Recum J, Wendl K, Vock B, Grützner PA, Franke J (2012) Intraoperative 3d c-arm imaging: state of the art. Der Unfallchirurg 115(3):196–201. doi:10.1007/s00113-011-2119-2 Von Recum J, Wendl K, Vock B, Grützner PA, Franke J (2012) Intraoperative 3d c-arm imaging: state of the art. Der Unfallchirurg 115(3):196–201. doi:10.​1007/​s00113-011-2119-2
19.
Zurück zum Zitat Wirth S, Euler E, Linsenmaier U, Heining SM, Kotsianos D, Pfeifer KJ, Mutschler W, Reiser M (2004) C-arm-based mobile computed tomography: a comparison with established imaging on the basis of simulated treatments of talus neck fractures in a cadaveric study. Comput Aided Surg 9(1–2):27–38CrossRefPubMed Wirth S, Euler E, Linsenmaier U, Heining SM, Kotsianos D, Pfeifer KJ, Mutschler W, Reiser M (2004) C-arm-based mobile computed tomography: a comparison with established imaging on the basis of simulated treatments of talus neck fractures in a cadaveric study. Comput Aided Surg 9(1–2):27–38CrossRefPubMed
20.
Zurück zum Zitat Yang Z, Fripp J, Chandra SS, Neubert A, Xia Y, Strudwick M, Paproki A, Engstrom C, Crozier S (2015) Automatic bone segmentation and bone-cartilage interface extraction for the shoulder joint from magnetic resonance images. Phys Med Biol 60(4):1441CrossRefPubMed Yang Z, Fripp J, Chandra SS, Neubert A, Xia Y, Strudwick M, Paproki A, Engstrom C, Crozier S (2015) Automatic bone segmentation and bone-cartilage interface extraction for the shoulder joint from magnetic resonance images. Phys Med Biol 60(4):1441CrossRefPubMed
21.
Zurück zum Zitat Yin Y, Zhang X, Williams R, Wu X, Anderson DD, Sonka M (2010) Logismos—layered optimal graph image segmentation of multiple objects and surfaces: cartilage segmentation in the knee joint. Med Imaging IEEE Trans 29(12):2023–2037CrossRef Yin Y, Zhang X, Williams R, Wu X, Anderson DD, Sonka M (2010) Logismos—layered optimal graph image segmentation of multiple objects and surfaces: cartilage segmentation in the knee joint. Med Imaging IEEE Trans 29(12):2023–2037CrossRef
22.
Zurück zum Zitat Zheng Y, John M, Liao R, Boese J, Kirschstein U, Georgescu B, Zhou SK, Kempfert J, Walther T, Brockmann G, Comaniciu D (2010) Automatic aorta segmentation and valve landmark detection in c-arm ct: application to aortic valve implantation. In: Medical image computing and computer-assisted intervention—MICCAI 2010, pp 476–483. Springer Zheng Y, John M, Liao R, Boese J, Kirschstein U, Georgescu B, Zhou SK, Kempfert J, Walther T, Brockmann G, Comaniciu D (2010) Automatic aorta segmentation and valve landmark detection in c-arm ct: application to aortic valve implantation. In: Medical image computing and computer-assisted intervention—MICCAI 2010, pp 476–483. Springer
Metadaten
Titel
Intra-operative assessment of fractured articular surfaces in cone beam CT image data
verfasst von
Michael Brehler
Joseph Görres
Sven Y. Vetter
Jochen Franke
Paul A. Grützner
Hans-Peter Meinzer
Ivo Wolf
Publikationsdatum
01.04.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 4/2016
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-015-1304-0

Weitere Artikel der Ausgabe 4/2016

International Journal of Computer Assisted Radiology and Surgery 4/2016 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.