Skip to main content
Erschienen in: Japanese Journal of Radiology 9/2015

01.09.2015 | Original Article

Comparative study of image quality between axial T2-weighted BLADE and turbo spin-echo MRI of the upper abdomen on 3.0 T

verfasst von: Lin Zhang, ChunMei Tian, PeiYuan Wang, Liang Chen, XiJin Mao, ShanShan Wang, Xu Wang, JingMin Dong, Bin Wang

Erschienen in: Japanese Journal of Radiology | Ausgabe 9/2015

Einloggen, um Zugang zu erhalten

Abstract

Objective

To compare image quality of turbo spin-echo (TSE) with BLADE [which is also named periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER)] on magnetic resonance imaging (MRI) for upper abdomen.

Materials and methods

This study involved the retrospective evaluation of 103 patients (63 males, 40 females; age range 19–76 years; median age 53.8 years) who underwent 3.0 T MRI with both conventional TSE T2-weighted imaging (T2WI) and BLADE TSE T2WI. Two radiologists assessed respiratory motion, gastrointestinal peristalsis, and vascular pulsation artifacts, as well as the sharpness of the liver and pancreas edges. Scores for all magnetic resonance (MR) images were recorded. Wilcoxon’s rank test was used to compare hierarchical data. Cohen’s kappa coefficient was adopted to analyze interobserver consistency.

Results

Compared to TSE T2WI, BLADE TSE T2WI reduced all of the examined motion artifacts and increased the sharpness of the liver and pancreas edges (all P < 0.05). Medium to good interobserver consistency was obtained for evaluating these indicators. The scanning time of BLADE TSE T2WI was 4–16 s shorter than that of conventional TSE T2WI.

Conclusion

Compared to TSE sequence, the BLADE technique can reduce the respiratory motion, gastrointestinal peristalsis, and vascular pulsation artifacts, while decreasing the scanning time and improving the anatomic detail and image quality.
Literatur
2.
Zurück zum Zitat Bayramoglu S, Kilickesmez O, Cimilli T, Kayhan A, Yirik G, Islim F, et al. T2-weighted MRI of the upper abdomen: comparison of four fat-suppressed T2-weighted sequences including PROPELLER (BLADE) technique. Acad Radiol. 2010;17(3):368–74.CrossRefPubMed Bayramoglu S, Kilickesmez O, Cimilli T, Kayhan A, Yirik G, Islim F, et al. T2-weighted MRI of the upper abdomen: comparison of four fat-suppressed T2-weighted sequences including PROPELLER (BLADE) technique. Acad Radiol. 2010;17(3):368–74.CrossRefPubMed
3.
Zurück zum Zitat Chang KJ, Kamel IR, Macura KJ, Bluemke DA. 3.0-T MR imaging of the abdomen: comparison with 1.5 T. Radiographics. 2008;28(7):1983–98.CrossRefPubMed Chang KJ, Kamel IR, Macura KJ, Bluemke DA. 3.0-T MR imaging of the abdomen: comparison with 1.5 T. Radiographics. 2008;28(7):1983–98.CrossRefPubMed
4.
Zurück zum Zitat Mirowitz SA. Diagnostic pitfalls and artifacts in abdominal MR imaging: a review. Radiology. 1998;208(3):577–89.CrossRefPubMed Mirowitz SA. Diagnostic pitfalls and artifacts in abdominal MR imaging: a review. Radiology. 1998;208(3):577–89.CrossRefPubMed
5.
Zurück zum Zitat Pipe JG. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med. 1999;42(5):963–9.CrossRefPubMed Pipe JG. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med. 1999;42(5):963–9.CrossRefPubMed
6.
Zurück zum Zitat Huang TY, Tseng YS, Tang YW, Lin YR. Optimization of PROPELLER reconstruction for free-breathing T1-weighted cardiac imaging. Med Phys. 2012;39(8):4896–902.CrossRefPubMed Huang TY, Tseng YS, Tang YW, Lin YR. Optimization of PROPELLER reconstruction for free-breathing T1-weighted cardiac imaging. Med Phys. 2012;39(8):4896–902.CrossRefPubMed
7.
Zurück zum Zitat Hirokawa Y, Isoda H, Maetani YS, Arizono S, Shimada K, Togashi K. MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and prospective acquisition correction (PACE) technique. AJR Am J Roentgenol. 2008;191(4):1154–8.CrossRefPubMed Hirokawa Y, Isoda H, Maetani YS, Arizono S, Shimada K, Togashi K. MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and prospective acquisition correction (PACE) technique. AJR Am J Roentgenol. 2008;191(4):1154–8.CrossRefPubMed
8.
Zurück zum Zitat Junping W, Tongguo S, Yunting Z, Chunshui Y, Renju B. Discrimination of axillary metastatic from nonmetastatic lymph nodes with PROPELLER diffusion-weighted MR imaging in a metastatic breast cancer model and its correlation with cellularity. J Magn Reson Imaging. 2012;36(3):624–31.CrossRefPubMed Junping W, Tongguo S, Yunting Z, Chunshui Y, Renju B. Discrimination of axillary metastatic from nonmetastatic lymph nodes with PROPELLER diffusion-weighted MR imaging in a metastatic breast cancer model and its correlation with cellularity. J Magn Reson Imaging. 2012;36(3):624–31.CrossRefPubMed
9.
Zurück zum Zitat Tan H, Hoge WS, Hamilton CA, Gunther M, Kraft RA. 3D GRASE PROPELLER: improved image acquisition technique for arterial spin labeling perfusion imaging. Magn Reson Med. 2011;66(1):168–73.PubMedCentralCrossRefPubMed Tan H, Hoge WS, Hamilton CA, Gunther M, Kraft RA. 3D GRASE PROPELLER: improved image acquisition technique for arterial spin labeling perfusion imaging. Magn Reson Med. 2011;66(1):168–73.PubMedCentralCrossRefPubMed
10.
Zurück zum Zitat Holmes JH, Beatty PJ, Rowley HA, Li Z, Gaddipati A, Zhao X, et al. Improved motion correction capabilities for fast spin echo T1 FLAIR propeller using non-cartesian external calibration data driven parallel imaging. Magn Reson Med. 2012;68(6):1856–65.CrossRefPubMed Holmes JH, Beatty PJ, Rowley HA, Li Z, Gaddipati A, Zhao X, et al. Improved motion correction capabilities for fast spin echo T1 FLAIR propeller using non-cartesian external calibration data driven parallel imaging. Magn Reson Med. 2012;68(6):1856–65.CrossRefPubMed
11.
Zurück zum Zitat Darge K, Anupindi SA, Jaramillo D. MR imaging of the abdomen and pelvis in infants, children, and adolescents. Radiology. 2011;261(1):12–29.CrossRefPubMed Darge K, Anupindi SA, Jaramillo D. MR imaging of the abdomen and pelvis in infants, children, and adolescents. Radiology. 2011;261(1):12–29.CrossRefPubMed
12.
Zurück zum Zitat Aksoy M, Skare S, Holdsworth S, Bammer R. Effects of motion and b-matrix correction for high resolution DTI with short-axis PROPELLER-EPI. NMR Biomed. 2010;23(7):794–802.PubMedCentralCrossRefPubMed Aksoy M, Skare S, Holdsworth S, Bammer R. Effects of motion and b-matrix correction for high resolution DTI with short-axis PROPELLER-EPI. NMR Biomed. 2010;23(7):794–802.PubMedCentralCrossRefPubMed
13.
Zurück zum Zitat Lane BF, Vandermeer FQ, Oz RC, Irwin EW, McMillan AB, Wong-You-Cheong JJ. Comparison of sagittal T2-weighted BLADE and fast spin-echo MRI of the female pelvis for motion artifact and lesion detection. AJR Am J Roentgenol. 2011;197(2):W307–13.CrossRefPubMed Lane BF, Vandermeer FQ, Oz RC, Irwin EW, McMillan AB, Wong-You-Cheong JJ. Comparison of sagittal T2-weighted BLADE and fast spin-echo MRI of the female pelvis for motion artifact and lesion detection. AJR Am J Roentgenol. 2011;197(2):W307–13.CrossRefPubMed
14.
Zurück zum Zitat Froehlich JM, Metens T, Chilla B, Hauser N, Klarhoefer M, Kubik-Huch RA. Should less motion sensitive T2-weighted BLADE TSE replace cartesian TSE for female pelvic MRI? Insights Imaging. 2012;3(6):611–8.PubMedCentralCrossRefPubMed Froehlich JM, Metens T, Chilla B, Hauser N, Klarhoefer M, Kubik-Huch RA. Should less motion sensitive T2-weighted BLADE TSE replace cartesian TSE for female pelvic MRI? Insights Imaging. 2012;3(6):611–8.PubMedCentralCrossRefPubMed
15.
Zurück zum Zitat Fujimoto K, Koyama T, Tamai K, Morisawa N, Okada T, Togashi K. BLADE acquisition method improves T2-weighted MR images of the female pelvis compared with a standard fast spin-echo sequence. Eur J Radiol. 2011;80(3):796–801.CrossRefPubMed Fujimoto K, Koyama T, Tamai K, Morisawa N, Okada T, Togashi K. BLADE acquisition method improves T2-weighted MR images of the female pelvis compared with a standard fast spin-echo sequence. Eur J Radiol. 2011;80(3):796–801.CrossRefPubMed
16.
Zurück zum Zitat Dietrich TJ, Ulbrich EJ, Zanetti M, Fucentese SF, Pfirrmann CW. PROPELLER technique to improve image quality of MRI of the shoulder. AJR Am J Roentgenol. 2011;197(6):W1093–100.CrossRefPubMed Dietrich TJ, Ulbrich EJ, Zanetti M, Fucentese SF, Pfirrmann CW. PROPELLER technique to improve image quality of MRI of the shoulder. AJR Am J Roentgenol. 2011;197(6):W1093–100.CrossRefPubMed
17.
Zurück zum Zitat Jin N, Guo Y, Zhang Z, Zhang L, Lu G, Larson AC. GESFIDE-PROPELLER approach for simultaneous R2 and R2* measurements in the abdomen. Magn Reson Imaging. 2013;31(10):1760–5.PubMedCentralCrossRefPubMed Jin N, Guo Y, Zhang Z, Zhang L, Lu G, Larson AC. GESFIDE-PROPELLER approach for simultaneous R2 and R2* measurements in the abdomen. Magn Reson Imaging. 2013;31(10):1760–5.PubMedCentralCrossRefPubMed
18.
Zurück zum Zitat Yamaguchi M, Mitsuda M, Ezawa K, Nakagami R, Furuta T, Sekine N, et al. Artifact-reduced simultaneous MRI of multiple rats with liver cancer using PROPELLER. J Magn Reson Imaging. 2013;38(1):225–30.CrossRefPubMed Yamaguchi M, Mitsuda M, Ezawa K, Nakagami R, Furuta T, Sekine N, et al. Artifact-reduced simultaneous MRI of multiple rats with liver cancer using PROPELLER. J Magn Reson Imaging. 2013;38(1):225–30.CrossRefPubMed
19.
Zurück zum Zitat Mateos-Fernandez M, Mas-Estelles F, de Paula-Vernetta C, Guzman-Calvete A, Villanueva-Marti R, Morera-Perez C. The role of diffusion-weighted magnetic resonance imaging in cholesteatoma diagnosis and follow-up. Study with the diffusion PROPELLER technique. Acta Otorrinolaringol Esp. 2012;63(6):436–42.CrossRefPubMed Mateos-Fernandez M, Mas-Estelles F, de Paula-Vernetta C, Guzman-Calvete A, Villanueva-Marti R, Morera-Perez C. The role of diffusion-weighted magnetic resonance imaging in cholesteatoma diagnosis and follow-up. Study with the diffusion PROPELLER technique. Acta Otorrinolaringol Esp. 2012;63(6):436–42.CrossRefPubMed
20.
Zurück zum Zitat Henrik HJ, Kramer H, et al. Renal T2-weighted turbo-spin-echo imaging with BLADE at 3.0 Tesla: initial experience. JMRI. 2008;27(1):148–53.CrossRef Henrik HJ, Kramer H, et al. Renal T2-weighted turbo-spin-echo imaging with BLADE at 3.0 Tesla: initial experience. JMRI. 2008;27(1):148–53.CrossRef
21.
Zurück zum Zitat Lavdas E, Topalzikis T, Mavroidis P, Kyriakis I, Roka V, Kostopoulos S, et al. Comparison of PD BLADE with fat saturation (FS), PD FS and T2 3D DESS with water excitation (WE) in detecting articular knee cartilage defects. Magn Reson Imaging. 2013;31(8):1255–62.CrossRefPubMed Lavdas E, Topalzikis T, Mavroidis P, Kyriakis I, Roka V, Kostopoulos S, et al. Comparison of PD BLADE with fat saturation (FS), PD FS and T2 3D DESS with water excitation (WE) in detecting articular knee cartilage defects. Magn Reson Imaging. 2013;31(8):1255–62.CrossRefPubMed
Metadaten
Titel
Comparative study of image quality between axial T2-weighted BLADE and turbo spin-echo MRI of the upper abdomen on 3.0 T
verfasst von
Lin Zhang
ChunMei Tian
PeiYuan Wang
Liang Chen
XiJin Mao
ShanShan Wang
Xu Wang
JingMin Dong
Bin Wang
Publikationsdatum
01.09.2015
Verlag
Springer Japan
Erschienen in
Japanese Journal of Radiology / Ausgabe 9/2015
Print ISSN: 1867-1071
Elektronische ISSN: 1867-108X
DOI
https://doi.org/10.1007/s11604-015-0463-9

Weitere Artikel der Ausgabe 9/2015

Japanese Journal of Radiology 9/2015 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.