Skip to main content
Erschienen in: Forensic Science, Medicine and Pathology 1/2012

01.03.2012 | Images in Forensics

Precise wound track measurement requires cat scan with object in situ: how accurate is post-mortem dissection and evaluation?

verfasst von: Carl Winskog

Erschienen in: Forensic Science, Medicine and Pathology | Ausgabe 1/2012

Einloggen, um Zugang zu erhalten

Excerpt

A middle-aged man committed suicide by stabbing and cutting himself repeatedly. The case was initially treated as suspicious as he was found naked in the forest not far from his home with multiple injuries to the neck, extremities and chest and with a kitchen knife still located in the chest. The kitchen knife was inserted to the full length of the blade with only the handle visible. However, the events leading up to his discovery together with the results from the autopsy did support suicide as the manner of death. The deceased was transported to the National Board of Forensic Medicine department in Linköping, Sweden, for examination. Computer assisted tomography (CT) was performed according to standard practice [1] with 3D volume rendering performed on the image material acquired. The position of the knife could clearly be seen on the CT images and the material from the digital autopsy also showed heart and lungs pushed over to the right side of the chest cavity. The angle and depth of the knife were measured at 45° (from the sagittal plane) and 19 cm. Angle and depth are clearly visible in the images (Fig. 1). An autopsy was performed and the injuries were documented. When the knife was removed the heart and lung regained its original position in the chest cavity thereby altering and concealing the position of the organs as seen on the CT image (Fig. 1). The depth of the new virtual wound track was estimated to 10 cm and the angle was straight in (0° from the sagittal plane) from front to back.
Literatur
1.
Zurück zum Zitat Ljung P, Winskog C, Persson A, Lundström C, Ynnerman A. Full Body virtual autopsies using a State-of-the-art volume rendering pipeline. IEEE Trans Vis Comput Graph (Proc vis 2006). 2006;12:869–76. Ljung P, Winskog C, Persson A, Lundström C, Ynnerman A. Full Body virtual autopsies using a State-of-the-art volume rendering pipeline. IEEE Trans Vis Comput Graph (Proc vis 2006). 2006;12:869–76.
2.
Zurück zum Zitat Jones S, Nokes L, Leadbeatter S. The mechanics of stab wounding. Forensic Sci Int. 1994;67:59–63.PubMedCrossRef Jones S, Nokes L, Leadbeatter S. The mechanics of stab wounding. Forensic Sci Int. 1994;67:59–63.PubMedCrossRef
3.
Zurück zum Zitat Sauko P, Knight B. Knight’s forensic pathology. 3rd ed. London: Edward Arnold Ltd; 2004. Sauko P, Knight B. Knight’s forensic pathology. 3rd ed. London: Edward Arnold Ltd; 2004.
Metadaten
Titel
Precise wound track measurement requires cat scan with object in situ: how accurate is post-mortem dissection and evaluation?
verfasst von
Carl Winskog
Publikationsdatum
01.03.2012
Verlag
Springer US
Erschienen in
Forensic Science, Medicine and Pathology / Ausgabe 1/2012
Print ISSN: 1547-769X
Elektronische ISSN: 1556-2891
DOI
https://doi.org/10.1007/s12024-011-9230-0

Weitere Artikel der Ausgabe 1/2012

Forensic Science, Medicine and Pathology 1/2012 Zur Ausgabe

Neu im Fachgebiet Pathologie

Molekularpathologische Untersuchungen im Wandel der Zeit

Open Access Biomarker Leitthema

Um auch an kleinen Gewebeproben zuverlässige und reproduzierbare Ergebnisse zu gewährleisten ist eine strenge Qualitätskontrolle in jedem Schritt des Arbeitsablaufs erforderlich. Eine nicht ordnungsgemäße Prüfung oder Behandlung des …

Vergleichende Pathologie in der onkologischen Forschung

Pathologie Leitthema

Die vergleichende experimentelle Pathologie („comparative experimental pathology“) ist ein Fachbereich an der Schnittstelle von Human- und Veterinärmedizin. Sie widmet sich der vergleichenden Erforschung von Gemeinsamkeiten und Unterschieden von …

Gastrointestinale Stromatumoren

Open Access GIST CME-Artikel

Gastrointestinale Stromatumoren (GIST) stellen seit über 20 Jahren ein Paradigma für die zielgerichtete Therapie mit Tyrosinkinaseinhibitoren dar. Eine elementare Voraussetzung für eine mögliche neoadjuvante oder adjuvante Behandlung bei …

Personalisierte Medizin in der Onkologie

Aufgrund des erheblichen technologischen Fortschritts in der molekularen und genetischen Diagnostik sowie zunehmender Erkenntnisse über die molekulare Pathogenese von Krankheiten hat in den letzten zwei Jahrzehnten ein grundlegender …