Skip to main content
Erschienen in: Pediatric Radiology 9/2015

01.08.2015 | Review

Magnetic resonance imaging acquisition techniques intended to decrease movement artefact in paediatric brain imaging: a systematic review

verfasst von: Julie Woodfield, Susan Kealey

Erschienen in: Pediatric Radiology | Ausgabe 9/2015

Einloggen, um Zugang zu erhalten

Abstract

Attaining paediatric brain images of diagnostic quality can be difficult because of young age or neurological impairment. The use of anaesthesia to reduce movement in MRI increases clinical risk and cost, while CT, though faster, exposes children to potentially harmful ionising radiation. MRI acquisition techniques that aim to decrease movement artefact may allow diagnostic paediatric brain imaging without sedation or anaesthesia. We conducted a systematic review to establish the evidence base for ultra-fast sequences and sequences using oversampling of k-space in paediatric brain MR imaging. Techniques were assessed for imaging time, occurrence of movement artefact, the need for sedation, and either image quality or diagnostic accuracy. We identified 24 relevant studies. We found that ultra-fast techniques had shorter imaging acquisition times compared to standard MRI. Techniques using oversampling of k-space required equal or longer imaging times than standard MRI. Both ultra-fast sequences and those using oversampling of k-space reduced movement artefact compared with standard MRI in unsedated children. Assessment of overall diagnostic accuracy was difficult because of the heterogeneous patient populations, imaging indications, and reporting methods of the studies. In children with shunt-treated hydrocephalus there is evidence that ultra-fast MRI is sufficient for the assessment of ventricular size.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284PubMedCrossRef Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284PubMedCrossRef
2.
Zurück zum Zitat Strauss KJ, Goske MJ, Kaste SC et al (2010) Image gently: ten steps you can take to optimize image quality and lower CT dose for pediatric patients. AJR Am J Roentgenol 194:868–873PubMedCrossRef Strauss KJ, Goske MJ, Kaste SC et al (2010) Image gently: ten steps you can take to optimize image quality and lower CT dose for pediatric patients. AJR Am J Roentgenol 194:868–873PubMedCrossRef
3.
Zurück zum Zitat Koral K, Blackburn T, Bailey AA et al (2012) Strengthening the argument for rapid brain MR imaging: estimation of reduction in lifetime attributable risk of developing fatal cancer in children with shunted hydrocephalus by instituting a rapid brain MR imaging protocol in lieu of head CT. AJNR Am J Neuroradiol 33:1851–1854PubMedCrossRef Koral K, Blackburn T, Bailey AA et al (2012) Strengthening the argument for rapid brain MR imaging: estimation of reduction in lifetime attributable risk of developing fatal cancer in children with shunted hydrocephalus by instituting a rapid brain MR imaging protocol in lieu of head CT. AJNR Am J Neuroradiol 33:1851–1854PubMedCrossRef
4.
Zurück zum Zitat Zimmerman RA, Haselgrove JC, Wang Z et al (1998) Advances in pediatric neuroimaging. Brain Dev 20:275–289PubMedCrossRef Zimmerman RA, Haselgrove JC, Wang Z et al (1998) Advances in pediatric neuroimaging. Brain Dev 20:275–289PubMedCrossRef
5.
Zurück zum Zitat Pipe JG (1999) Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 42:963–969PubMedCrossRef Pipe JG (1999) Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 42:963–969PubMedCrossRef
6.
Zurück zum Zitat Iskandar BJ, Sansone JM, Medow J et al (2004) The use of quick-brain magnetic resonance imaging in the evaluation of shunt-treated hydrocephalus. J Neurosurg 101:147–151PubMed Iskandar BJ, Sansone JM, Medow J et al (2004) The use of quick-brain magnetic resonance imaging in the evaluation of shunt-treated hydrocephalus. J Neurosurg 101:147–151PubMed
7.
Zurück zum Zitat Ashley WW Jr, McKinstry RC, Leonard JR et al (2005) Use of rapid-sequence magnetic resonance imaging for evaluation of hydrocephalus in children. J Neurosurg 103:124–130PubMedCrossRef Ashley WW Jr, McKinstry RC, Leonard JR et al (2005) Use of rapid-sequence magnetic resonance imaging for evaluation of hydrocephalus in children. J Neurosurg 103:124–130PubMedCrossRef
8.
Zurück zum Zitat Missios S, Quebada PB, Forero JA et al (2008) Quick-brain magnetic resonance imaging for nonhydrocephalus indications. J Neurosurg Pediatr 2:438–444PubMedCrossRef Missios S, Quebada PB, Forero JA et al (2008) Quick-brain magnetic resonance imaging for nonhydrocephalus indications. J Neurosurg Pediatr 2:438–444PubMedCrossRef
9.
Zurück zum Zitat Tachibana Y, Niwa T, Kwee TC et al (2012) Effective performance of T(1)-weighted FLAIR imaging with BLADE in pediatric brains. Magn Reson Med Sci 11:17–26PubMedCrossRef Tachibana Y, Niwa T, Kwee TC et al (2012) Effective performance of T(1)-weighted FLAIR imaging with BLADE in pediatric brains. Magn Reson Med Sci 11:17–26PubMedCrossRef
11.
Zurück zum Zitat Moher D, Liberati A, Tetzlaff J et al (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med 6:e1000097PubMedCentralPubMedCrossRef Moher D, Liberati A, Tetzlaff J et al (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med 6:e1000097PubMedCentralPubMedCrossRef
12.
Zurück zum Zitat Moher D, Liberati A, Tetzlaff J et al (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ 339:b2535PubMedCentralPubMedCrossRef Moher D, Liberati A, Tetzlaff J et al (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ 339:b2535PubMedCentralPubMedCrossRef
13.
Zurück zum Zitat Hart AR, Smith MF, Rigby AS et al (2010) Appearances of diffuse excessive high signal intensity (DEHSI) on MR imaging following preterm birth. Pediatr Radiol 40:1390–1396PubMedCrossRef Hart AR, Smith MF, Rigby AS et al (2010) Appearances of diffuse excessive high signal intensity (DEHSI) on MR imaging following preterm birth. Pediatr Radiol 40:1390–1396PubMedCrossRef
14.
Zurück zum Zitat Singh RK, Smith JT, Wilkinson ID et al (2003) Ultrafast MR imaging in pediatric neuroradiology. Acta Radiol 44:550–557PubMedCrossRef Singh RK, Smith JT, Wilkinson ID et al (2003) Ultrafast MR imaging in pediatric neuroradiology. Acta Radiol 44:550–557PubMedCrossRef
15.
Zurück zum Zitat Penzkofer AK, Pfluger T, Pochmann Y et al (2002) MR imaging of the brain in pediatric patients: diagnostic value of HASTE sequences. AJR Am J Roentgenol 179:509–514PubMedCrossRef Penzkofer AK, Pfluger T, Pochmann Y et al (2002) MR imaging of the brain in pediatric patients: diagnostic value of HASTE sequences. AJR Am J Roentgenol 179:509–514PubMedCrossRef
16.
Zurück zum Zitat Ge Y, Korogi Y, Sugahara T et al (2001) Comparison between EPI and HASTE for ultra-fast MR imaging of the human brain. Neuroradiology 43:1046–1055PubMedCrossRef Ge Y, Korogi Y, Sugahara T et al (2001) Comparison between EPI and HASTE for ultra-fast MR imaging of the human brain. Neuroradiology 43:1046–1055PubMedCrossRef
17.
Zurück zum Zitat Ba-Ssalamaha A, Schick S, Heimberger K et al (2000) Ultrafast magnetic resonance imaging of the brain. Magn Reson Imaging 18:237–243PubMedCrossRef Ba-Ssalamaha A, Schick S, Heimberger K et al (2000) Ultrafast magnetic resonance imaging of the brain. Magn Reson Imaging 18:237–243PubMedCrossRef
18.
Zurück zum Zitat Sugahara T, Korogi Y, Hirai T et al (1997) Comparison of HASTE and segmented-HASTE sequences with a T2-weighted fast spin-echo sequence in the screening evaluation of the brain. AJR Am J Roentgenol 169:1401–1410PubMedCrossRef Sugahara T, Korogi Y, Hirai T et al (1997) Comparison of HASTE and segmented-HASTE sequences with a T2-weighted fast spin-echo sequence in the screening evaluation of the brain. AJR Am J Roentgenol 169:1401–1410PubMedCrossRef
19.
Zurück zum Zitat Patel DM, Tubbs RS, Pate G et al (2014) Fast-sequence MRI studies for surveillance imaging in pediatric hydrocephalus. J Neurosurg Pediatr 13:440–447PubMedCrossRef Patel DM, Tubbs RS, Pate G et al (2014) Fast-sequence MRI studies for surveillance imaging in pediatric hydrocephalus. J Neurosurg Pediatr 13:440–447PubMedCrossRef
20.
Zurück zum Zitat Rozovsky K, Ventureyra EC, Miller E (2013) Fast-brain MRI in children is quick, without sedation, and radiation-free, but beware of limitations. J Clin Neurosci 20:400–405PubMedCrossRef Rozovsky K, Ventureyra EC, Miller E (2013) Fast-brain MRI in children is quick, without sedation, and radiation-free, but beware of limitations. J Clin Neurosci 20:400–405PubMedCrossRef
21.
Zurück zum Zitat Niederhauser BD, McDonald RJ, Eckel LJ et al (2013) Retrospective review of rapid pediatric brain MR imaging at an academic institution including practice trends and factors affecting scan times. AJNR Am J Neuroradiol 34:1836–1840PubMedCrossRef Niederhauser BD, McDonald RJ, Eckel LJ et al (2013) Retrospective review of rapid pediatric brain MR imaging at an academic institution including practice trends and factors affecting scan times. AJNR Am J Neuroradiol 34:1836–1840PubMedCrossRef
22.
Zurück zum Zitat O’Neill BR, Pruthi S, Bains H et al (2013) Rapid sequence magnetic resonance imaging in the assessment of children with hydrocephalus. World Neurosurg 80:e307–312PubMedCrossRef O’Neill BR, Pruthi S, Bains H et al (2013) Rapid sequence magnetic resonance imaging in the assessment of children with hydrocephalus. World Neurosurg 80:e307–312PubMedCrossRef
23.
Zurück zum Zitat Wait SD, Lingo R, Boop FA et al (2012) Eight-second MRI scan for evaluation of shunted hydrocephalus. Childs Nerv Syst 28:1237–1241PubMedCrossRef Wait SD, Lingo R, Boop FA et al (2012) Eight-second MRI scan for evaluation of shunted hydrocephalus. Childs Nerv Syst 28:1237–1241PubMedCrossRef
24.
Zurück zum Zitat Miller JH, Walkiewicz T, Towbin RB et al (2010) Improved delineation of ventricular shunt catheters using fast steady-state gradient recalled-echo sequences in a rapid brain MR imaging protocol in nonsedated pediatric patients. AJNR Am J Neuroradiol 31:430–435PubMedCrossRef Miller JH, Walkiewicz T, Towbin RB et al (2010) Improved delineation of ventricular shunt catheters using fast steady-state gradient recalled-echo sequences in a rapid brain MR imaging protocol in nonsedated pediatric patients. AJNR Am J Neuroradiol 31:430–435PubMedCrossRef
25.
Zurück zum Zitat Griffiths PD, Wilkinson ID, Patel MC et al (2000) Acute neuromedical and neurosurgical admissions. Standard and ultrafast MR imaging of the brain compared with cranial CT. Acta Radiol 41:401–409PubMed Griffiths PD, Wilkinson ID, Patel MC et al (2000) Acute neuromedical and neurosurgical admissions. Standard and ultrafast MR imaging of the brain compared with cranial CT. Acta Radiol 41:401–409PubMed
26.
Zurück zum Zitat Boyle TP, Paldino MJ, Kimia AA et al (2014) Comparison of rapid cranial MRI to CT for ventricular shunt malfunction. Pediatrics 134:e47–54PubMedCrossRef Boyle TP, Paldino MJ, Kimia AA et al (2014) Comparison of rapid cranial MRI to CT for ventricular shunt malfunction. Pediatrics 134:e47–54PubMedCrossRef
27.
Zurück zum Zitat Von Kalle T, Blank B, Fabig-Moritz C et al (2009) Reduced artefacts and improved assessment of hyperintense brain lesions with BLADE MR imaging in patients with neurofibromatosis type 1. Pediatr Radiol 39:1216–1222CrossRef Von Kalle T, Blank B, Fabig-Moritz C et al (2009) Reduced artefacts and improved assessment of hyperintense brain lesions with BLADE MR imaging in patients with neurofibromatosis type 1. Pediatr Radiol 39:1216–1222CrossRef
28.
Zurück zum Zitat Vertinsky AT, Rubesova E, Krasnokutsky MV et al (2009) Performance of PROPELLER relative to standard FSE T2-weighted imaging in pediatric brain MRI. Pediatr Radiol 39:1038–1047PubMedCrossRef Vertinsky AT, Rubesova E, Krasnokutsky MV et al (2009) Performance of PROPELLER relative to standard FSE T2-weighted imaging in pediatric brain MRI. Pediatr Radiol 39:1038–1047PubMedCrossRef
29.
Zurück zum Zitat Alkan O, Kizilkilic O, Yildirim T et al (2009) Comparison of contrast-enhanced T1-weighted FLAIR with BLADE, and spin-echo T1-weighted sequences in intracranial MRI. Diagn Interv Radiol 15:75–80PubMed Alkan O, Kizilkilic O, Yildirim T et al (2009) Comparison of contrast-enhanced T1-weighted FLAIR with BLADE, and spin-echo T1-weighted sequences in intracranial MRI. Diagn Interv Radiol 15:75–80PubMed
30.
Zurück zum Zitat Alibek S, Adamietz B, Cavallaro A et al (2008) Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient? Acad Radiol 15:986–995PubMedCrossRef Alibek S, Adamietz B, Cavallaro A et al (2008) Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient? Acad Radiol 15:986–995PubMedCrossRef
31.
Zurück zum Zitat Forbes KP, Pipe JG, Bird CR et al (2001) PROPELLER MRI: clinical testing of a novel technique for quantification and compensation of head motion. J Magn Reson Imaging 14:215–222PubMedCrossRef Forbes KP, Pipe JG, Bird CR et al (2001) PROPELLER MRI: clinical testing of a novel technique for quantification and compensation of head motion. J Magn Reson Imaging 14:215–222PubMedCrossRef
32.
Zurück zum Zitat Forbes KP, Pipe JG, Karis JP et al (2003) Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences. AJNR Am J Neuroradiol 24:794–798PubMed Forbes KP, Pipe JG, Karis JP et al (2003) Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences. AJNR Am J Neuroradiol 24:794–798PubMed
33.
Zurück zum Zitat Levine D, Zuo C, Faro CB et al (2001) Potential heating effect in the gravid uterus during MR HASTE imaging. J Magn Reson Imaging 13:856–861PubMedCrossRef Levine D, Zuo C, Faro CB et al (2001) Potential heating effect in the gravid uterus during MR HASTE imaging. J Magn Reson Imaging 13:856–861PubMedCrossRef
34.
Zurück zum Zitat Wang FN, Huang TY, Lin FH et al (2005) PROPELLER EPI: an MRI technique suitable for diffusion tensor imaging at high field strength with reduced geometric distortions. Magn Reson Med 54:1232–1240PubMedCentralPubMedCrossRef Wang FN, Huang TY, Lin FH et al (2005) PROPELLER EPI: an MRI technique suitable for diffusion tensor imaging at high field strength with reduced geometric distortions. Magn Reson Med 54:1232–1240PubMedCentralPubMedCrossRef
Metadaten
Titel
Magnetic resonance imaging acquisition techniques intended to decrease movement artefact in paediatric brain imaging: a systematic review
verfasst von
Julie Woodfield
Susan Kealey
Publikationsdatum
01.08.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Pediatric Radiology / Ausgabe 9/2015
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-015-3333-9

Weitere Artikel der Ausgabe 9/2015

Pediatric Radiology 9/2015 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.