Skip to main content
Erschienen in: Skeletal Radiology 4/2019

12.06.2018 | Technical Report

Modified technique for imaging the wrist and elbow in obese and claustrophobic patients using a non-open standard MRI scanner

verfasst von: Nishant Gupta, Ian Karol, Yogesh Kumar, Brian Rapillo, Neetu Soni, Daichi Hayashi

Erschienen in: Skeletal Radiology | Ausgabe 4/2019

Einloggen, um Zugang zu erhalten

Abstract

Objective

It is challenging to image extremely obese and claustrophobic patients using a standard, non-open, magnetic resonance imaging (MRI) scanner. On the other hand, installing an additional upright or open MRI scanner may not be cost-effective for most practices. Our technique with a patient in a sitting or standing position behind the standard MRI scanner may be helpful in the MR examination of the wrist/elbow in these patients using a standard wrist/elbow coil.

Material and methods

We performed wrist and elbow MRI of extremely obese and claustrophobic patients by using our modified technique with the patient sitting or standing outside the standard non-open MRI scanner. A total number of 20 cases with the following diagnosis were examined: triquetral and scaphoid bone contusions and fractures, scapholunate ligament tears, triangular fibrocartilage complex tear, and biceps tear.

Results

Comparison of image quality for diagnostic information between the standard technique and our technique showed no significant difference, which is necessary for making the diagnosis.

Conclusions

Our technique enables wrist and elbow imaging of extremely obese and claustrophobic patients who cannot otherwise be imaged using a standard MRI scanner without compromising the image quality that is essential for making a diagnosis.
Literatur
1.
Zurück zum Zitat Enders J, Zimmermann E, Rief M, Martus P, Klingebiel R, Asbach P, et al. Reduction of claustrophobia during magnetic resonance imaging: methods and design of the “CLAUSTRO” randomized controlled trial. BMC Med Imaging. 2011;11:4:1–15. Enders J, Zimmermann E, Rief M, Martus P, Klingebiel R, Asbach P, et al. Reduction of claustrophobia during magnetic resonance imaging: methods and design of the “CLAUSTRO” randomized controlled trial. BMC Med Imaging. 2011;11:4:1–15.
2.
Zurück zum Zitat Dewey M, Schink T, Dewey CF. Claustrophobia during magnetic resonance imaging: cohort study in over 55,000 patients. J Magn Reson Imaging. 2007;26:1322–7.CrossRefPubMed Dewey M, Schink T, Dewey CF. Claustrophobia during magnetic resonance imaging: cohort study in over 55,000 patients. J Magn Reson Imaging. 2007;26:1322–7.CrossRefPubMed
3.
4.
Zurück zum Zitat Munn Z, Jordan Z. Interventions to reduce anxiety, distress and the need for sedation in adult patients undergoing magnetic resonance imaging: a systematic review. Int J Evid Based Healthc. 2013;11:265–74.CrossRefPubMed Munn Z, Jordan Z. Interventions to reduce anxiety, distress and the need for sedation in adult patients undergoing magnetic resonance imaging: a systematic review. Int J Evid Based Healthc. 2013;11:265–74.CrossRefPubMed
5.
Zurück zum Zitat Rothschild PA, Domesek JM, Eastham ME, Kaufman L. MR imaging of excessively obese patients: the use of an open permanent magnet. Magn Reson Imaging. 1991;9:151–4.CrossRefPubMed Rothschild PA, Domesek JM, Eastham ME, Kaufman L. MR imaging of excessively obese patients: the use of an open permanent magnet. Magn Reson Imaging. 1991;9:151–4.CrossRefPubMed
6.
Zurück zum Zitat Buckley O, Ward E, Ryan A, Colin W, Snow A, Torreggiani WC. European obesity and the radiology department. What can we do to help? Eur Radiol. 2009;19:298–309.CrossRefPubMed Buckley O, Ward E, Ryan A, Colin W, Snow A, Torreggiani WC. European obesity and the radiology department. What can we do to help? Eur Radiol. 2009;19:298–309.CrossRefPubMed
7.
Zurück zum Zitat Merl T, Scholz M, Gerhardt P, Langer M, Laubenberger J, Weiss HD, et al. Results of a prospective multicenter study for evaluation of the diagnostic quality of an open whole-body low-field MRI unit. A comparison with high-field MRI measured by the applicable gold standard. Eur J Radiol. 1999;30:43–53.CrossRefPubMed Merl T, Scholz M, Gerhardt P, Langer M, Laubenberger J, Weiss HD, et al. Results of a prospective multicenter study for evaluation of the diagnostic quality of an open whole-body low-field MRI unit. A comparison with high-field MRI measured by the applicable gold standard. Eur J Radiol. 1999;30:43–53.CrossRefPubMed
8.
Zurück zum Zitat Hailey D. Open magnetic resonance imaging (MRI) scanners. Issues Emerg Health Technol. 2006:(92)1–4. Hailey D. Open magnetic resonance imaging (MRI) scanners. Issues Emerg Health Technol. 2006:(92)1–4.
9.
Zurück zum Zitat Hunt CH, Wood CP, Lane JI, Bolster BD, Bernstein MA, Witte RJ. Wide, short bore magnetic resonance at 1.5 T: reducing the failure rate in claustrophobic patients. Clin Neuroradiol. 2011;21:141–4.CrossRefPubMed Hunt CH, Wood CP, Lane JI, Bolster BD, Bernstein MA, Witte RJ. Wide, short bore magnetic resonance at 1.5 T: reducing the failure rate in claustrophobic patients. Clin Neuroradiol. 2011;21:141–4.CrossRefPubMed
10.
Zurück zum Zitat Heuck A, Bonél H, Huber A, Müller-Lisse GU, Sittek H, Reiser M. Akzeptanz von Hochfeld-Ganzkörper-MR-Geräten, offenem MR-System und dediziertem Extremitätenscanner durch die Patienten. Radiologe. 1997;37:778–84.CrossRefPubMed Heuck A, Bonél H, Huber A, Müller-Lisse GU, Sittek H, Reiser M. Akzeptanz von Hochfeld-Ganzkörper-MR-Geräten, offenem MR-System und dediziertem Extremitätenscanner durch die Patienten. Radiologe. 1997;37:778–84.CrossRefPubMed
11.
Zurück zum Zitat Bangard C, Paszek J, Berg F, Eyl G, Kessler J, Lackner K, et al. MR imaging of claustrophobic patients in an open 1.0T scanner: motion artifacts and patient acceptability compared with closed bore magnets. Eur J Radiol. 2007;64:152–7.CrossRefPubMed Bangard C, Paszek J, Berg F, Eyl G, Kessler J, Lackner K, et al. MR imaging of claustrophobic patients in an open 1.0T scanner: motion artifacts and patient acceptability compared with closed bore magnets. Eur J Radiol. 2007;64:152–7.CrossRefPubMed
12.
Zurück zum Zitat Dantendorfer K, Wimberger D, Katschnig H, Imhoff H. Claustrophobia in MRI scanners. Lancet. 1991;338:761–2.CrossRefPubMed Dantendorfer K, Wimberger D, Katschnig H, Imhoff H. Claustrophobia in MRI scanners. Lancet. 1991;338:761–2.CrossRefPubMed
Metadaten
Titel
Modified technique for imaging the wrist and elbow in obese and claustrophobic patients using a non-open standard MRI scanner
verfasst von
Nishant Gupta
Ian Karol
Yogesh Kumar
Brian Rapillo
Neetu Soni
Daichi Hayashi
Publikationsdatum
12.06.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Skeletal Radiology / Ausgabe 4/2019
Print ISSN: 0364-2348
Elektronische ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-018-2988-3

Weitere Artikel der Ausgabe 4/2019

Skeletal Radiology 4/2019 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.