After the very successful clinical introduction of combined PET/CT imaging a decade ago, a hardware combination of PET and MR is following suit. Today, three different approaches towards integrated PET/MR have been proposed: (1) a triple-modality system with a 3T MRI and a time-of-flight PET/CT installed in adjacent rooms, (2) a tandem system with a 3T MRI and a time-of-flight PET/CT in a co-planar installation with a joint patient handling system, and (3) a fully-integrated system with a whole-body PET system mounted inside a 3T MRI system. This special issue of MAGMA brings together contributions from key experts in the field of PET/MR, PET/CT and CT. The various papers share the author’s perspectives on the state-of-the-art PET/MR imaging with any of the three approaches mentioned above. In addition to several reviews discussing advantages and challenges of combining PET and MRI for clinical diagnostics, first clinical data are also presented. We expect this special issue to nurture future improvements in hardware, clinical protocols, and efficient post-processing strategies to further assess the diagnostic value of combined PET/MR imaging. It remains to be seen whether a so-called “killer application” for PET/MRI will surface. In that case PET/MR is likely to excel in pre-clinical and selected research applications for now. This special issue helps the readers to stay on track of this exciting development.
Literatur
1.
Zurück zum Zitat Wehrl HF, Judenhofer MS, Wiehr S, Pichler BJ (2009) Pre-clinical PET/MR: technological advances and new perspectives in biomedical research. Eur J Nucl Med Mol Imaging 36(Suppl 1):S56–S68PubMedCrossRef Wehrl HF, Judenhofer MS, Wiehr S, Pichler BJ (2009) Pre-clinical PET/MR: technological advances and new perspectives in biomedical research. Eur J Nucl Med Mol Imaging 36(Suppl 1):S56–S68PubMedCrossRef
2.
Zurück zum Zitat Pichler BJ, Kolb A, Nägele T, Schlemmer HP (2010) PET/MRI: paving the way for the next generation of clinical multimodality imaging applications. J Nucl Med 51(3):333–336PubMedCrossRef Pichler BJ, Kolb A, Nägele T, Schlemmer HP (2010) PET/MRI: paving the way for the next generation of clinical multimodality imaging applications. J Nucl Med 51(3):333–336PubMedCrossRef
3.
Zurück zum Zitat Beyer T, Freudenberg LS, Czernin J, Townsend DW (2011) The future of hybrid imaging-part 3: PET/MR, small-animal imaging and beyond. Insights Imaging 2(3):235–246PubMedCrossRef Beyer T, Freudenberg LS, Czernin J, Townsend DW (2011) The future of hybrid imaging-part 3: PET/MR, small-animal imaging and beyond. Insights Imaging 2(3):235–246PubMedCrossRef
4.
Zurück zum Zitat Goyen M, Debatin JF (2009) Healthcare costs for new technologies. Eur J Nucl Med Mol Imaging 36(Suppl 1):S139–S143PubMedCrossRef Goyen M, Debatin JF (2009) Healthcare costs for new technologies. Eur J Nucl Med Mol Imaging 36(Suppl 1):S139–S143PubMedCrossRef
5.
Zurück zum Zitat Kalemis A, Delattre BM, Heinzer S (2013) Sequential whole-body PET/MR scanner: concept, clinical use, and optimisation after two years in the clinic. The manufacturer’s perspective. Magn Reson Mater Phy 26(1):5–23 Kalemis A, Delattre BM, Heinzer S (2013) Sequential whole-body PET/MR scanner: concept, clinical use, and optimisation after two years in the clinic. The manufacturer’s perspective. Magn Reson Mater Phy 26(1):5–23
6.
Zurück zum Zitat Veit-Haibach P, Kuhn FP, Wiesinger F, Delso G, von Schulthess G (2013) PET–MR imaging using a tri-modality PET/CT–MR system with a dedicated shuttle in clinical routine. Magn Reson Mater Phy 26(1):25–35 Veit-Haibach P, Kuhn FP, Wiesinger F, Delso G, von Schulthess G (2013) PET–MR imaging using a tri-modality PET/CT–MR system with a dedicated shuttle in clinical routine. Magn Reson Mater Phy 26(1):25–35
7.
Zurück zum Zitat Kinahan PE, Townsend DW, Beyer T, Sashin D (1998) Attenuation correction for a combined 3D PET/CT scanner. Med Phys 25(10):2046–2053PubMedCrossRef Kinahan PE, Townsend DW, Beyer T, Sashin D (1998) Attenuation correction for a combined 3D PET/CT scanner. Med Phys 25(10):2046–2053PubMedCrossRef
8.
Zurück zum Zitat von Schulthess GK, Burger C (2010) Integrating imaging modalities: what makes sense from a workflow perspective? Eur J Nucl Med Mol Imaging 37(5):980–990CrossRef von Schulthess GK, Burger C (2010) Integrating imaging modalities: what makes sense from a workflow perspective? Eur J Nucl Med Mol Imaging 37(5):980–990CrossRef
9.
Zurück zum Zitat Kjær A, Loft A, Law I, Berthelsen A, Borgwardt L, Löfgren J, Johnbeck C, Hansen A, Keller S, Holm S, Højgaard L (2013) PET/MRI in cancer patients: first experiences and vision from Copenhagen. Magn Reson Mater Phy 26(1):37–47 Kjær A, Loft A, Law I, Berthelsen A, Borgwardt L, Löfgren J, Johnbeck C, Hansen A, Keller S, Holm S, Højgaard L (2013) PET/MRI in cancer patients: first experiences and vision from Copenhagen. Magn Reson Mater Phy 26(1):37–47
10.
Zurück zum Zitat Platzek I, Beuthien-Baumann B, Langner J, Popp M, Schramm G, Ordemann R, Laniado M, Kotzerke J, van den Hoff J (2013) PET/MR for therapy response evaluation in malignant lymphoma: initial experience. Magn Reson Mater Phy 26(1):49–55 Platzek I, Beuthien-Baumann B, Langner J, Popp M, Schramm G, Ordemann R, Laniado M, Kotzerke J, van den Hoff J (2013) PET/MR for therapy response evaluation in malignant lymphoma: initial experience. Magn Reson Mater Phy 26(1):49–55
11.
Zurück zum Zitat Antoch G, Bockisch A (2009) Combined PET/MRI: a new dimension in whole-body oncology imaging? Eur J Nucl Med Mol Imaging 36(Suppl 1):S113–S120PubMedCrossRef Antoch G, Bockisch A (2009) Combined PET/MRI: a new dimension in whole-body oncology imaging? Eur J Nucl Med Mol Imaging 36(Suppl 1):S113–S120PubMedCrossRef
12.
Zurück zum Zitat Buchbender C, Heusner TA, Lauenstein TC, Bockisch A, Antoch G (2012) Oncologic PET/MRI, part 1: tumors of the brain, head and neck, chest, abdomen, and pelvis. J Nucl Med 53(6):928–938PubMedCrossRef Buchbender C, Heusner TA, Lauenstein TC, Bockisch A, Antoch G (2012) Oncologic PET/MRI, part 1: tumors of the brain, head and neck, chest, abdomen, and pelvis. J Nucl Med 53(6):928–938PubMedCrossRef
13.
Zurück zum Zitat Buchbender C, Heusner TA, Lauenstein TC, Bockisch A, Antoch G (2012) Oncologic PET/MRI, part 2: bone tumors, soft-tissue tumors, melanoma, and lymphoma. J Nucl Med 53(8):1244–1252PubMedCrossRef Buchbender C, Heusner TA, Lauenstein TC, Bockisch A, Antoch G (2012) Oncologic PET/MRI, part 2: bone tumors, soft-tissue tumors, melanoma, and lymphoma. J Nucl Med 53(8):1244–1252PubMedCrossRef
14.
Zurück zum Zitat Vargas MI, Becker M, Garibotto V, Heinzer S, Loubeyre P, Gariani J, Lovblad K, Vallée JP, Ratib O (2013) Approaches for the optimization of MR protocols in clinical hybrid PET/MRI studies. Magn Reson Mater Phy 26(1):57–69 Vargas MI, Becker M, Garibotto V, Heinzer S, Loubeyre P, Gariani J, Lovblad K, Vallée JP, Ratib O (2013) Approaches for the optimization of MR protocols in clinical hybrid PET/MRI studies. Magn Reson Mater Phy 26(1):57–69
15.
Zurück zum Zitat Cho ZH, Son YD, Choi EJ, Kim HK, Kim JH, Lee SY, Ogawa S, Kim YB (2013) In-vivo human brain molecular imaging with a brain-dedicated PET/MRI system. Magn Reson Mater Phy 26(1):71–79 Cho ZH, Son YD, Choi EJ, Kim HK, Kim JH, Lee SY, Ogawa S, Kim YB (2013) In-vivo human brain molecular imaging with a brain-dedicated PET/MRI system. Magn Reson Mater Phy 26(1):71–79
16.
Zurück zum Zitat van Velden FH, Kloet RW, van Berckel BN, Buijs FL, Luurtsema G, Lammertsma AA, Boellaard R (2009) HRRT versus HR+ human brain PET studies: an inter scanner test–retest study. J Nucl Med 50(5):693–702PubMedCrossRef van Velden FH, Kloet RW, van Berckel BN, Buijs FL, Luurtsema G, Lammertsma AA, Boellaard R (2009) HRRT versus HR+ human brain PET studies: an inter scanner test–retest study. J Nucl Med 50(5):693–702PubMedCrossRef
17.
Zurück zum Zitat Wahl RL, Quint LE, Cieslak RD, Aisen AM, Koeppe RA, Meyer CR (1993) “Anatometabolic” tumor imaging: fusion of FDG PET with CT or MRI to localize foci of increased activity. J Nucl Med 34(7):1190–1197PubMed Wahl RL, Quint LE, Cieslak RD, Aisen AM, Koeppe RA, Meyer CR (1993) “Anatometabolic” tumor imaging: fusion of FDG PET with CT or MRI to localize foci of increased activity. J Nucl Med 34(7):1190–1197PubMed
18.
Zurück zum Zitat Keereman V, Mollet P, Berker Y, Schulz V, Vandenberghe S (2013) Challenges and current methods for attenuation correction in PET/MR. Magn Reson Mater Phy 26(1):81–98 Keereman V, Mollet P, Berker Y, Schulz V, Vandenberghe S (2013) Challenges and current methods for attenuation correction in PET/MR. Magn Reson Mater Phy 26(1):81–98
19.
Zurück zum Zitat Wagenknecht G, Kaiser HJ, Mottaghy FM, Herzog H (2013) MRI for attenuation correction in PET: methods and challenges. Magn Reson Mater Phy 26(1):99–113 Wagenknecht G, Kaiser HJ, Mottaghy FM, Herzog H (2013) MRI for attenuation correction in PET: methods and challenges. Magn Reson Mater Phy 26(1):99–113
20.
Zurück zum Zitat Hofmann M, Pichler B, Schölkopf B, Beyer T (2009) Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques. Eur J Nucl Med Mol Imaging 36(Suppl 1):S93–S104PubMedCrossRef Hofmann M, Pichler B, Schölkopf B, Beyer T (2009) Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques. Eur J Nucl Med Mol Imaging 36(Suppl 1):S93–S104PubMedCrossRef
21.
Zurück zum Zitat Schramm G, Langner J, Hofheinz F, Petr J, Beuthien-Baumann B, Platzek I, Steinbach J, Kotzerke J, van den Hoff J (2013) Quantitative accuracy of attenuation correction in the Philips Ingenuity TF whole-body PET/MR system: a direct comparison with transmission-based attenuation correction. Magn Reson Mater Phy 26(1):115–126CrossRef Schramm G, Langner J, Hofheinz F, Petr J, Beuthien-Baumann B, Platzek I, Steinbach J, Kotzerke J, van den Hoff J (2013) Quantitative accuracy of attenuation correction in the Philips Ingenuity TF whole-body PET/MR system: a direct comparison with transmission-based attenuation correction. Magn Reson Mater Phy 26(1):115–126CrossRef
22.
Zurück zum Zitat Larsson A, Johansson A, Axelsson J, Nyholm T, Asklund T, Riklund K, Karlsson M (2013) Evaluation of an attenuation correction method for PET/MR imaging of the head based on substitute CT images. Magn Reson Mater Phy 26(1):127–136 Larsson A, Johansson A, Axelsson J, Nyholm T, Asklund T, Riklund K, Karlsson M (2013) Evaluation of an attenuation correction method for PET/MR imaging of the head based on substitute CT images. Magn Reson Mater Phy 26(1):127–136
23.
Zurück zum Zitat Pietrzyk U, Herzog H (2013) Does PET/MR in human brain imaging provide optimal registration? A critical reflection. Magn Reson Mater Phy 26(1):137–147 Pietrzyk U, Herzog H (2013) Does PET/MR in human brain imaging provide optimal registration? A critical reflection. Magn Reson Mater Phy 26(1):137–147
24.
Zurück zum Zitat Gillings N (2013) Radiotracers for positron emission tomography imaging. Magn Reson Mater Phy 26(1):149–158 Gillings N (2013) Radiotracers for positron emission tomography imaging. Magn Reson Mater Phy 26(1):149–158
25.
Zurück zum Zitat Sattler B, Jochimsen T, Barthel H, Sommerfeld K, Stumpp P, Hoffmann KT, Gutberlet M, Villringer A, Kahn T, Sabri O (2013) Physical and organizational provision for installation, regulatory requirements and implementation of a simultaneous hybrid PET/MR-imaging system in an integrated research and clinical setting. Magn Reson Mater Phy 26(1):159–171 Sattler B, Jochimsen T, Barthel H, Sommerfeld K, Stumpp P, Hoffmann KT, Gutberlet M, Villringer A, Kahn T, Sabri O (2013) Physical and organizational provision for installation, regulatory requirements and implementation of a simultaneous hybrid PET/MR-imaging system in an integrated research and clinical setting. Magn Reson Mater Phy 26(1):159–171
26.
Zurück zum Zitat Keller SH, Holm S, Hansen AE, Sattler B, Andersen F, Klausen TL, Højgaard L, Kjær A, Beyer T (2013) Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI. Magn Reson Mater Phy 26(1):173–181 Keller SH, Holm S, Hansen AE, Sattler B, Andersen F, Klausen TL, Højgaard L, Kjær A, Beyer T (2013) Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI. Magn Reson Mater Phy 26(1):173–181
27.
Zurück zum Zitat Brix G, Nekolla EA, Nosske D, Griebel J (2009) Risks and safety aspects related to PET/MR examinations. Eur J Nucl Med Mol Imaging 36(Suppl 1):S131–S138PubMedCrossRef Brix G, Nekolla EA, Nosske D, Griebel J (2009) Risks and safety aspects related to PET/MR examinations. Eur J Nucl Med Mol Imaging 36(Suppl 1):S131–S138PubMedCrossRef
28.
Zurück zum Zitat Moser E, Stadlbauer A, Windischberger C, Quick HH, Ladd ME (2009) Magnetic resonance imaging methodology. Eur J Nucl Med Mol Imaging 36(Suppl 1):S30–S41PubMedCrossRef Moser E, Stadlbauer A, Windischberger C, Quick HH, Ladd ME (2009) Magnetic resonance imaging methodology. Eur J Nucl Med Mol Imaging 36(Suppl 1):S30–S41PubMedCrossRef
29.
Zurück zum Zitat Moser E, Stahlberg F, Ladd ME, Trattnig S (2012) 7-T MR—from research to clinical applications? NMR Biomed 25(5):695–716PubMedCrossRef Moser E, Stahlberg F, Ladd ME, Trattnig S (2012) 7-T MR—from research to clinical applications? NMR Biomed 25(5):695–716PubMedCrossRef
Metadaten
Titel
MR/PET or PET/MRI: does it matter?
verfasst von
Thomas Beyer
Ewald Moser
Publikationsdatum
01.02.2013
Verlag
Springer-Verlag
Erschienen in
Magnetic Resonance Materials in Physics, Biology and Medicine / Ausgabe 1/2013
Print ISSN: 0968-5243
Elektronische ISSN: 1352-8661
DOI
https://doi.org/10.1007/s10334-012-0365-0

Weitere Artikel der Ausgabe 1/2013

Magnetic Resonance Materials in Physics, Biology and Medicine 1/2013 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.