Abstract

To compare the image quality of dynamic lung MRI with variations of steady-state free-precession (SSFP) and gradient echo (GRE) cine techniques at 1.5 T and 3 T. Ventilated porcine lungs with simulated lesions inside a chest phantom and four healthy human subjects were assessed with SSFP (TR/TE = 2.9/1.22 ms; 3 ima/s) and GRE sequences (TR/TE = 2.34/0.96 ms; 8 ima/s) as baseline at 1.5 and 3 T. Modified SSFPs were performed with nine to ten images/s (parallel imaging factors 2 and 3). Image quality for representative structures and artifacts was ranked by three observers independently. At 1.5 T, standard SSFP achieved the best image quality with superior spatial resolution and signal, but equal temporal resolution to GRE. SSFP with improved temporal resolution was ranked second best. Further acceleration (PI factor 3) was of no benefit, but increased artifacts. At 3 T, GRE outranged SSFP imaging with high lesion signal intensity, while artifacts on SSFP images increased visibly. At 1.5 T, a modified SSFP with moderate parallel imaging (PI factor 2) was considered the best compromise of temporal and spatial resolution. At 3 T, GRE sequences remain the best choice for dynamic lung MRI.
Literatur
1.
Zurück zum Zitat Antoch G, Vogt FM, Freudenberg LS et al (2003) Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology. JAMA 290:3199–3206PubMedCrossRef Antoch G, Vogt FM, Freudenberg LS et al (2003) Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology. JAMA 290:3199–3206PubMedCrossRef
2.
Zurück zum Zitat Antoch G, Vogt FM, Bockisch A, Ruehm SG (2004) [Whole-body tumor staging: MRI or FDG-PET/CT?]. Radiologe 44:882–888PubMedCrossRef Antoch G, Vogt FM, Bockisch A, Ruehm SG (2004) [Whole-body tumor staging: MRI or FDG-PET/CT?]. Radiologe 44:882–888PubMedCrossRef
3.
Zurück zum Zitat Schmidt GP, Haug AR, Schoenberg SO, Reiser MF (2006) Whole-body MRI and PET-CT in the management of cancer patients. Eur Radiol 16:1216–1225PubMedCrossRef Schmidt GP, Haug AR, Schoenberg SO, Reiser MF (2006) Whole-body MRI and PET-CT in the management of cancer patients. Eur Radiol 16:1216–1225PubMedCrossRef
4.
Zurück zum Zitat Ghanem N, Altehoefer C, Kelly T et al (2006) Whole-body MRI in comparison to skeletal scintigraphy in detection of skeletal metastases in patients with solid tumors. In Vivo 20:173–182PubMed Ghanem N, Altehoefer C, Kelly T et al (2006) Whole-body MRI in comparison to skeletal scintigraphy in detection of skeletal metastases in patients with solid tumors. In Vivo 20:173–182PubMed
5.
Zurück zum Zitat Schafer JF, Fischmann A, Lichy M et al (2004) [Oncologic screening with whole-body MRI: possibilities and limitations]. Radiologe 44:854–863PubMedCrossRef Schafer JF, Fischmann A, Lichy M et al (2004) [Oncologic screening with whole-body MRI: possibilities and limitations]. Radiologe 44:854–863PubMedCrossRef
6.
Zurück zum Zitat Biederer J, Puderbach M, Hintze C. A Practical Approach to Lung MRI at 1.5T. Magnetom Flash. 02/2006 ed, 2007 Biederer J, Puderbach M, Hintze C. A Practical Approach to Lung MRI at 1.5T. Magnetom Flash. 02/2006 ed, 2007
7.
Zurück zum Zitat Hintze C, Biederer J, Wenz HW, Eberhardt R, Kauczor HU (2006) [MRI in staging of lung cancer.]. Radiologe 46:251–259PubMedCrossRef Hintze C, Biederer J, Wenz HW, Eberhardt R, Kauczor HU (2006) [MRI in staging of lung cancer.]. Radiologe 46:251–259PubMedCrossRef
8.
Zurück zum Zitat Eibel R, Herzog P, Dietrich O et al (2006) Pulmonary abnormalities in immunocompromised patients: comparative detection with parallel acquisition MR imaging and thin-section helical CT. Radiology 241:880–891PubMedCrossRef Eibel R, Herzog P, Dietrich O et al (2006) Pulmonary abnormalities in immunocompromised patients: comparative detection with parallel acquisition MR imaging and thin-section helical CT. Radiology 241:880–891PubMedCrossRef
9.
Zurück zum Zitat Eibel R, Herzog P, Dietrich O et al (2006) [Magnetic resonance imaging in the evaluation of pneumonia]. Radiologe 46:267–4PubMedCrossRef Eibel R, Herzog P, Dietrich O et al (2006) [Magnetic resonance imaging in the evaluation of pneumonia]. Radiologe 46:267–4PubMedCrossRef
10.
Zurück zum Zitat Leutner C, Gieseke J, Lutterbey G et al (1999) [MRT versus CT in the diagnosis of pneumonias: an evaluation of a T2-weighted ultrafast turbo-spin-echo sequence (UTSE)]. Rofo 170:449–456PubMed Leutner C, Gieseke J, Lutterbey G et al (1999) [MRT versus CT in the diagnosis of pneumonias: an evaluation of a T2-weighted ultrafast turbo-spin-echo sequence (UTSE)]. Rofo 170:449–456PubMed
11.
Zurück zum Zitat Leutner CC, Gieseke J, Lutterbey G et al (2000) MR imaging of pneumonia in immunocompromised patients: comparison with helical CT. AJR Am J Roentgenol 175:391–397PubMed Leutner CC, Gieseke J, Lutterbey G et al (2000) MR imaging of pneumonia in immunocompromised patients: comparison with helical CT. AJR Am J Roentgenol 175:391–397PubMed
12.
Zurück zum Zitat Eichinger M, Puderbach M, Fink C et al (2006) Contrast-enhanced 3D MRI of lung perfusion in children with cystic fibrosis–initial results. Eur Radiol 16:2147–2152PubMedCrossRef Eichinger M, Puderbach M, Fink C et al (2006) Contrast-enhanced 3D MRI of lung perfusion in children with cystic fibrosis–initial results. Eur Radiol 16:2147–2152PubMedCrossRef
13.
Zurück zum Zitat Puderbach M, Eichinger M, Haeselbarth J et al (2007) Assessment of morphological MRI for pulmonary changes in cystic fibrosis (CF) patients: comparison to thin-section CT and chest x-ray. Invest Radiol 42:715–725PubMedCrossRef Puderbach M, Eichinger M, Haeselbarth J et al (2007) Assessment of morphological MRI for pulmonary changes in cystic fibrosis (CF) patients: comparison to thin-section CT and chest x-ray. Invest Radiol 42:715–725PubMedCrossRef
14.
Zurück zum Zitat Plathow C, Hof H, Kuhn S et al (2006) Therapy monitoring using dynamic MRI: analysis of lung motion and intrathoracic tumor mobility before and after radiotherapy. Eur Radiol 16:1942–1950PubMedCrossRef Plathow C, Hof H, Kuhn S et al (2006) Therapy monitoring using dynamic MRI: analysis of lung motion and intrathoracic tumor mobility before and after radiotherapy. Eur Radiol 16:1942–1950PubMedCrossRef
15.
Zurück zum Zitat Dinkel J, Welzel T, Bolte H, et al. (2007) Four-dimensional multislice helical CT of the lung: Qualitative comparison of retrospectively gated and static images in an ex-vivo system. Radiother Oncol Dinkel J, Welzel T, Bolte H, et al. (2007) Four-dimensional multislice helical CT of the lung: Qualitative comparison of retrospectively gated and static images in an ex-vivo system. Radiother Oncol
16.
Zurück zum Zitat Puderbach M, Hintze C, Ley S, Eichinger M, Kauczor HU, Biederer J (2007) MR imaging of the chest: A practical approach at 1.5T. Eur J Radiol Puderbach M, Hintze C, Ley S, Eichinger M, Kauczor HU, Biederer J (2007) MR imaging of the chest: A practical approach at 1.5T. Eur J Radiol
17.
Zurück zum Zitat Kluge A, Gerriets T, Muller C et al (2005) [Thoracic real-time MRI: experience from 2200 examinations in acute and ill-defined thoracic diseases]. Rofo 177:1513–1521PubMed Kluge A, Gerriets T, Muller C et al (2005) [Thoracic real-time MRI: experience from 2200 examinations in acute and ill-defined thoracic diseases]. Rofo 177:1513–1521PubMed
18.
Zurück zum Zitat Schafer JF, Vollmar J, Schick F et al (2005) [Detection of pulmonary nodules with breath-hold magnetic resonance imaging in comparison with computed tomography]. Rofo 177:41–49PubMed Schafer JF, Vollmar J, Schick F et al (2005) [Detection of pulmonary nodules with breath-hold magnetic resonance imaging in comparison with computed tomography]. Rofo 177:41–49PubMed
19.
Zurück zum Zitat Lutterbey G, Gieseke J, von FM, Morakkabati N, Schild H (2005) Lung MRI at 3.0 T: a comparison of helical CT and high-field MRI in the detection of diffuse lung disease. Eur Radiol 15:324–328PubMedCrossRef Lutterbey G, Gieseke J, von FM, Morakkabati N, Schild H (2005) Lung MRI at 3.0 T: a comparison of helical CT and high-field MRI in the detection of diffuse lung disease. Eur Radiol 15:324–328PubMedCrossRef
20.
Zurück zum Zitat Biederer J (2005) [Magnetic resonance imaging: technical aspects and recent developments]. Med Klin (Munich) 100:62–72CrossRef Biederer J (2005) [Magnetic resonance imaging: technical aspects and recent developments]. Med Klin (Munich) 100:62–72CrossRef
21.
Zurück zum Zitat Biederer J, Heller M (2003) Artificial thorax for MR imaging studies in porcine heart-lung preparations. Radiology 226:250–255PubMedCrossRef Biederer J, Heller M (2003) Artificial thorax for MR imaging studies in porcine heart-lung preparations. Radiology 226:250–255PubMedCrossRef
22.
Zurück zum Zitat Biederer J, Plathow C, Schoebinger M et al (2006) Reproducible simulation of respiratory motion in porcine lung explants. Rofo 178:1067–1072PubMed Biederer J, Plathow C, Schoebinger M et al (2006) Reproducible simulation of respiratory motion in porcine lung explants. Rofo 178:1067–1072PubMed
23.
Zurück zum Zitat Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO (2007) Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 26:375–385PubMedCrossRef Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO (2007) Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 26:375–385PubMedCrossRef
24.
Zurück zum Zitat Hatabu H, Gaa J, Tadamura E et al (1999) MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequence. Eur J Radiol 29:152–159PubMedCrossRef Hatabu H, Gaa J, Tadamura E et al (1999) MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequence. Eur J Radiol 29:152–159PubMedCrossRef
25.
Zurück zum Zitat Hatabu H, Chen Q, Stock KW, Gefter WB, Itoh H (1999) Fast magnetic resonance imaging of the lung. Eur J Radiol 29:114–132PubMedCrossRef Hatabu H, Chen Q, Stock KW, Gefter WB, Itoh H (1999) Fast magnetic resonance imaging of the lung. Eur J Radiol 29:114–132PubMedCrossRef
26.
Zurück zum Zitat Lutterbey G, Grohe C, Gieseke J et al (2007) Initial experience with lung-MRI at 3.0 T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity. Eur J Radiol 61:256–261PubMedCrossRef Lutterbey G, Grohe C, Gieseke J et al (2007) Initial experience with lung-MRI at 3.0 T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity. Eur J Radiol 61:256–261PubMedCrossRef
27.
Zurück zum Zitat Fink C, Puderbach M, Biederer J et al (2007) Lung MRI at 1.5 and 3 Tesla: observer preference study and lesion contrast using five different pulse sequences. Invest Radiol 42:377–383PubMedCrossRef Fink C, Puderbach M, Biederer J et al (2007) Lung MRI at 1.5 and 3 Tesla: observer preference study and lesion contrast using five different pulse sequences. Invest Radiol 42:377–383PubMedCrossRef
28.
Zurück zum Zitat Gutberlet M, Schwinge K, Freyhardt P et al (2005) Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging: comparison of 1.5 T vs. 3.0 T. Eur Radiol 15:1586–1597PubMedCrossRef Gutberlet M, Schwinge K, Freyhardt P et al (2005) Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging: comparison of 1.5 T vs. 3.0 T. Eur Radiol 15:1586–1597PubMedCrossRef
29.
Zurück zum Zitat Tyler DJ, Hudsmith LE, Petersen SE et al (2006) Cardiac cine MR-imaging at 3T: FLASH vs SSFP. J Cardiovasc Magn Reson 8:709–715PubMedCrossRef Tyler DJ, Hudsmith LE, Petersen SE et al (2006) Cardiac cine MR-imaging at 3T: FLASH vs SSFP. J Cardiovasc Magn Reson 8:709–715PubMedCrossRef
Metadaten
Titel
MRI of respiratory dynamics with 2D steady-state free-precession and 2D gradient echo sequences at 1.5 and 3 Tesla: an observer preference study
verfasst von
M. Fabel
B. J. Wintersperger
O. Dietrich
M. Eichinger
C. Fink
M. Puderbach
H.-U. Kauczor
S. O. Schoenberg
J. Biederer
Publikationsdatum
01.02.2009
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 2/2009
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-1148-x

Weitere Artikel der Ausgabe 2/2009

European Radiology 2/2009 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.