Skip to main content
Erschienen in: Radiological Physics and Technology 2/2018

12.04.2018

Myocardial motion analysis based on an optical flow method using tagged MR images

verfasst von: Daiki Tabata, Haruo Isoda, Kaori Kato, Hiroki Matsubara, Takafumi Kosugi, Takashi Kosugi, Masaki Terada, Atsushi Fukuyama, Yoshiaki Komori, Shinji Naganawa

Erschienen in: Radiological Physics and Technology | Ausgabe 2/2018

Einloggen, um Zugang zu erhalten

Abstract

We developed a method of velocimetry based on an optical flow method using quantitative analyses of tagged magnetic resonance (MR) images (tagged MR-optical flow velocimetry, tMR-O velocimetry). The purpose of our study was to examine the accuracy of measurement of the proposed tMR-O velocimetry. We performed retrospective pseudo-electrocardiogram (ECG) gating tagged cine MR imaging on a rotating phantom. We optimized imaging parameters for tagged MR imaging, and validated the accuracy of tMR-O velocimetry. Our results indicated that the difference between the reference velocities and the computed velocities measured using optimal imaging parameters was less than 1%. In addition, we performed tMR-O velocimetry and echocardiography on 10 healthy volunteers, for four sections of the heart (apical, midventricular, and basal sections aligned with the short-axis, and a four-chamber section aligned with the long-axis), and obtained radial and longitudinal myocardial velocities in these sections. We compared the myocardial velocities obtained using tMR-O velocimetry with those obtained using echocardiography. Our results showed good agreement between tMR-O velocimetry and echocardiography in the radial myocardial velocities in three short-axial sections and longitudinal myocardial velocities on the midventricular portion of the four-chamber section in the long-axis. In the study conducted on the rotating phantom, tMR-O velocimetry showed high accuracy; moreover, in the healthy volunteers, the myocardial velocities obtained using tMR-O velocimetry were relatively similar to those obtained using echocardiography. In conclusion, tMR-O velocimetry is a potentially feasible method for analyzing myocardial motion in the human heart.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
4.
Zurück zum Zitat Young AA, Kramer CM, Ferrari VA, Axel L, Reichek N. Three-dimensional left ventricular deformation in hypertrophic cardiomyopathy. Circulation. 1994;90:854–67.CrossRefPubMed Young AA, Kramer CM, Ferrari VA, Axel L, Reichek N. Three-dimensional left ventricular deformation in hypertrophic cardiomyopathy. Circulation. 1994;90:854–67.CrossRefPubMed
7.
Zurück zum Zitat Pelc LR, Sayre J, Yun K, Castro LJ, Herfkens RJ, Miller DC, Pelc NJ. Evaluation of myocardial motion tracking with cine-phase contrast magnetic resonance imaging. Invest Radiol. 1994;29:1038–42.CrossRefPubMed Pelc LR, Sayre J, Yun K, Castro LJ, Herfkens RJ, Miller DC, Pelc NJ. Evaluation of myocardial motion tracking with cine-phase contrast magnetic resonance imaging. Invest Radiol. 1994;29:1038–42.CrossRefPubMed
9.
Zurück zum Zitat Axel L, Gonçalves RC, Bloomgarden D. Regional heart wall motion: two-dimensional analysis and functional imaging with MR imaging. Radiology. 1992;183:745–50.CrossRefPubMed Axel L, Gonçalves RC, Bloomgarden D. Regional heart wall motion: two-dimensional analysis and functional imaging with MR imaging. Radiology. 1992;183:745–50.CrossRefPubMed
12.
Zurück zum Zitat Kearney JK, Thompson WB, Boley DL. Optical flow estimation: an error Analysis of gradient based methods with locai optimization. IEEE Trans Pattern Anal Mach Intell. 1987;9:229–44.CrossRefPubMed Kearney JK, Thompson WB, Boley DL. Optical flow estimation: an error Analysis of gradient based methods with locai optimization. IEEE Trans Pattern Anal Mach Intell. 1987;9:229–44.CrossRefPubMed
13.
Zurück zum Zitat Atsushi N, Miike H. Field theory approach for determining optical flow. Pattern Recognit. 1991;12:183–90.CrossRef Atsushi N, Miike H. Field theory approach for determining optical flow. Pattern Recognit. 1991;12:183–90.CrossRef
14.
Zurück zum Zitat Prince JL, McVeigh ER. Motion estimation from tagged MR image sequences. IEEE Trans Med Imaging. 1992;11:238–49.CrossRefPubMed Prince JL, McVeigh ER. Motion estimation from tagged MR image sequences. IEEE Trans Med Imaging. 1992;11:238–49.CrossRefPubMed
15.
Zurück zum Zitat Dougherty L, Asmuth JC, Blom AS, Axel L, Kumar R. Validation of an optical flow method for tag displacement estimation. IEEE Trans Med Imaging. 1999;18:359–63.CrossRefPubMed Dougherty L, Asmuth JC, Blom AS, Axel L, Kumar R. Validation of an optical flow method for tag displacement estimation. IEEE Trans Med Imaging. 1999;18:359–63.CrossRefPubMed
17.
Zurück zum Zitat Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–10.CrossRefPubMed Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–10.CrossRefPubMed
21.
Zurück zum Zitat Amundsen BH, Crosby J, Steen PA, Torp H, Slørdahl SA, Støylen A. Regional myocardial long-axis strain and strain rate measured by different tissue Doppler and speckle tracking echocardiography methods: a comparison with tagged magnetic resonance imaging. Eur J Echocardiogr. 2009;10:229–37. https://doi.org/10.1093/ejechocard/jen201.PubMedCrossRef Amundsen BH, Crosby J, Steen PA, Torp H, Slørdahl SA, Støylen A. Regional myocardial long-axis strain and strain rate measured by different tissue Doppler and speckle tracking echocardiography methods: a comparison with tagged magnetic resonance imaging. Eur J Echocardiogr. 2009;10:229–37. https://​doi.​org/​10.​1093/​ejechocard/​jen201.PubMedCrossRef
Metadaten
Titel
Myocardial motion analysis based on an optical flow method using tagged MR images
verfasst von
Daiki Tabata
Haruo Isoda
Kaori Kato
Hiroki Matsubara
Takafumi Kosugi
Takashi Kosugi
Masaki Terada
Atsushi Fukuyama
Yoshiaki Komori
Shinji Naganawa
Publikationsdatum
12.04.2018
Verlag
Springer Singapore
Erschienen in
Radiological Physics and Technology / Ausgabe 2/2018
Print ISSN: 1865-0333
Elektronische ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-018-0456-3

Weitere Artikel der Ausgabe 2/2018

Radiological Physics and Technology 2/2018 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.