Skip to main content
Erschienen in: European Radiology 6/2018

19.01.2018 | Cardiac

Myocardial perfusion in patients with suspected coronary artery disease: comparison between 320-MDCT and rubidium-82 PET

verfasst von: Roberto Nery Dantas Jr, Antonildes Nascimento Assuncao Jr, Ismar Aguiar Marques, Mateus Guimaraes Fahel, Cesar Higa Nomura, Luiz Francisco Rodrigues Avila, Maria Clementina Pinto Giorgi, Jose Soares Jr, Jose Claudio Meneghetti, Jose Rodrigues Parga

Erschienen in: European Radiology | Ausgabe 6/2018

Einloggen, um Zugang zu erhalten

Abstract

Objectives

Despite advances in non-invasive myocardial perfusion imaging (MPI) evaluation, computed tomography (CT) multiphase MPI protocols have not yet been compared with the highly accurate rubidium-82 positron emission tomography (82RbPET) MPI. Thus, this study aimed to evaluate agreement between 82RbPET and 320-detector row CT (320-CT) MPI using a multiphase protocol in suspected CAD patients.

Methods

Forty-four patients referred for MPI evaluation were prospectively enrolled and underwent dipyridamole stress 82RbPET and multiphase 320-CT MPI (five consecutive volumetric acquisitions during stress). Statistical analyses were performed using the R software.

Results

There was high agreement for recognizing summed stress scores ≥ 4 (kappa 0.77, 95% CI 0.55–0.98, p < 0.001) and moderate for detecting SDS ≥ 2 (kappa 0.51, 95% CI 0.23–0.80, p < 0.001). In a per segment analysis, agreement was high for the presence of perfusion defects during stress and rest (kappa 0.75 and 0.82, respectively) and was moderate for impairment severity (kappa 0.58 and 0.65, respectively). The 320-CT protocol was safe, with low radiation burden (9.3 ± 2.4 mSv).

Conclusions

There was a significant agreement between dipyridamole stress 320-CT MPI and 82RbPET MPI in the evaluation of suspected CAD patients of intermediate risk. The multiphase 320-CT MPI protocol was feasible, diagnostic and with relatively low radiation exposure.

Key Points

Rubidium-82 PET and 320-MDCT can perform MPI studies for CAD investigation.
There is high agreement between rubidium-82 PET and 320-MDCT for MPI assessment.
Multiphase CT perfusion protocols are feasible and with low radiation.
Multiphase CT perfusion protocols can identify image artefacts.
Literatur
1.
Zurück zum Zitat Douglas PS, Hoffmann U, Patel MR et al (2015) Outcomes of anatomical versus functional testing for coronary artery disease. N Engl J Med 372:1291–1300CrossRefPubMedPubMedCentral Douglas PS, Hoffmann U, Patel MR et al (2015) Outcomes of anatomical versus functional testing for coronary artery disease. N Engl J Med 372:1291–1300CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Cremer P, Hachamovitch R, Tamarappoo B (2014) Clinical decision making with myocardial perfusion imaging in patients with known or suspected coronary artery disease. Semin Nucl Med 44:320–329CrossRefPubMedPubMedCentral Cremer P, Hachamovitch R, Tamarappoo B (2014) Clinical decision making with myocardial perfusion imaging in patients with known or suspected coronary artery disease. Semin Nucl Med 44:320–329CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Mc Ardle BA, Dowsley TF, deKemp RA et al (2012) Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease?: A systematic review and meta-analysis. J Am Coll Cardiol 60:1828–1837CrossRefPubMed Mc Ardle BA, Dowsley TF, deKemp RA et al (2012) Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease?: A systematic review and meta-analysis. J Am Coll Cardiol 60:1828–1837CrossRefPubMed
4.
Zurück zum Zitat Miller JM, Rochitte CE, Dewey M et al (2008) Diagnostic performance of coronary angiography by 64-row CT. N Engl J Med 359:2324–2336CrossRefPubMed Miller JM, Rochitte CE, Dewey M et al (2008) Diagnostic performance of coronary angiography by 64-row CT. N Engl J Med 359:2324–2336CrossRefPubMed
5.
Zurück zum Zitat Arbab-Zadeh A, Hoe J (2011) Quantification of coronary arterial stenoses by multidetector CT angiography in comparison with conventional angiography methods, caveats, and implications. JACC Cardiovasc Imaging 4:191–202CrossRefPubMed Arbab-Zadeh A, Hoe J (2011) Quantification of coronary arterial stenoses by multidetector CT angiography in comparison with conventional angiography methods, caveats, and implications. JACC Cardiovasc Imaging 4:191–202CrossRefPubMed
6.
Zurück zum Zitat George RT, Arbab-Zadeh A, Miller JM et al (2009) Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: a pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia. Circ Cardiovasc Imaging 2:174–182CrossRefPubMedPubMedCentral George RT, Arbab-Zadeh A, Miller JM et al (2009) Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: a pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia. Circ Cardiovasc Imaging 2:174–182CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Rochitte CE, George RT, Chen MY et al (2014) Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography: the CORE320 study. Eur Heart J 35:1120–1130CrossRefPubMed Rochitte CE, George RT, Chen MY et al (2014) Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography: the CORE320 study. Eur Heart J 35:1120–1130CrossRefPubMed
8.
Zurück zum Zitat Williams MC, Weir NW, Mirsadraee S et al (2013) Iterative reconstruction and individualized automatic tube current selection reduce radiation dose while maintaining image quality in 320-multidetector computed tomography coronary angiography. Clin Radiol 68:e570–e577CrossRefPubMedPubMedCentral Williams MC, Weir NW, Mirsadraee S et al (2013) Iterative reconstruction and individualized automatic tube current selection reduce radiation dose while maintaining image quality in 320-multidetector computed tomography coronary angiography. Clin Radiol 68:e570–e577CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Ziemer BP, Hubbard L, Lipinski J, Molloi S (2015) Dynamic CT perfusion measurement in a cardiac phantom. Int J Card Imaging 31:1451–1459CrossRef Ziemer BP, Hubbard L, Lipinski J, Molloi S (2015) Dynamic CT perfusion measurement in a cardiac phantom. Int J Card Imaging 31:1451–1459CrossRef
10.
Zurück zum Zitat Danad I, Szymonifka J, Schulman-Marcus J, Min JK (2016) Static and dynamic assessment of myocardial perfusion by computed tomography. Eur Hear J Cardiovasc Imaging 17:836–844CrossRef Danad I, Szymonifka J, Schulman-Marcus J, Min JK (2016) Static and dynamic assessment of myocardial perfusion by computed tomography. Eur Hear J Cardiovasc Imaging 17:836–844CrossRef
11.
Zurück zum Zitat Agatston AS, Janowitz WR, Hildner FJ et al (1990) Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15:827–832CrossRefPubMed Agatston AS, Janowitz WR, Hildner FJ et al (1990) Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15:827–832CrossRefPubMed
12.
Zurück zum Zitat Halliburton SS, Abbara S, Chen MY et al (2011) SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT. J Cardiovasc Comput Tomogr 5:198–224CrossRefPubMedPubMedCentral Halliburton SS, Abbara S, Chen MY et al (2011) SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT. J Cardiovasc Comput Tomogr 5:198–224CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Cerqueira MD, Weissman NJ, Dilsizian V et al (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statementfor healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105:539–42 Cerqueira MD, Weissman NJ, Dilsizian V et al (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statementfor healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105:539–42
14.
Zurück zum Zitat Yoshinaga K, Chow BJ, Williams K et al (2006) What is the prognostic value of myocardial perfusion imaging using rubidium-82 positron emission tomography? J Am Coll Cardiol 48:1029–1039CrossRefPubMed Yoshinaga K, Chow BJ, Williams K et al (2006) What is the prognostic value of myocardial perfusion imaging using rubidium-82 positron emission tomography? J Am Coll Cardiol 48:1029–1039CrossRefPubMed
15.
16.
Zurück zum Zitat Cury RC, Magalhães TA, Borges AC et al (2010) Dipyridamole stress and rest myocardial perfusion by 64-detector row computed tomography in patients with suspected coronary artery disease. Am J Cardiol 106:310–315CrossRefPubMed Cury RC, Magalhães TA, Borges AC et al (2010) Dipyridamole stress and rest myocardial perfusion by 64-detector row computed tomography in patients with suspected coronary artery disease. Am J Cardiol 106:310–315CrossRefPubMed
17.
Zurück zum Zitat George RT, Arbab-Zadeh A, Cerci RJ et al (2011) Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320-MDCT: the CT angiography and perfusion methods of the CORE320 multicenter multinational diagnostic study. AJR Am J Roentgenol 197:829–837CrossRefPubMedPubMedCentral George RT, Arbab-Zadeh A, Cerci RJ et al (2011) Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320-MDCT: the CT angiography and perfusion methods of the CORE320 multicenter multinational diagnostic study. AJR Am J Roentgenol 197:829–837CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Hachamovitch R, Hayes SW, Friedman JD et al (2004) Stress myocardial perfusion single-photon emission computed tomography is clinically effective and cost effective in risk stratification of patients with a high likelihood of coronary artery disease (CAD) but no known CAD. J Am Coll Cardiol 43:200–208CrossRefPubMed Hachamovitch R, Hayes SW, Friedman JD et al (2004) Stress myocardial perfusion single-photon emission computed tomography is clinically effective and cost effective in risk stratification of patients with a high likelihood of coronary artery disease (CAD) but no known CAD. J Am Coll Cardiol 43:200–208CrossRefPubMed
19.
Zurück zum Zitat Dorbala S, Di Carli MF, Beanlands RS et al (2013) Prognostic value of stress myocardial perfusion positron emission tomography: results from a multicenter observational registry. J Am Coll Cardiol 61:176–184CrossRefPubMed Dorbala S, Di Carli MF, Beanlands RS et al (2013) Prognostic value of stress myocardial perfusion positron emission tomography: results from a multicenter observational registry. J Am Coll Cardiol 61:176–184CrossRefPubMed
20.
Zurück zum Zitat Chen A, Wang H, Fan B et al (2017) Prognostic value of normal positron emission tomography myocardial perfusion imaging in patients with known or suspected coronary artery disease: a meta-analysis. Br J Radiol 90:20160702CrossRefPubMed Chen A, Wang H, Fan B et al (2017) Prognostic value of normal positron emission tomography myocardial perfusion imaging in patients with known or suspected coronary artery disease: a meta-analysis. Br J Radiol 90:20160702CrossRefPubMed
21.
Zurück zum Zitat Kikuchi Y, Oyama-Manabe N, Naya M et al (2014) Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with 15O-H2O PET. Eur Radiol 24:1547–1556CrossRefPubMed Kikuchi Y, Oyama-Manabe N, Naya M et al (2014) Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with 15O-H2O PET. Eur Radiol 24:1547–1556CrossRefPubMed
22.
Zurück zum Zitat Klein R, Beanlands RSB, deKemp RA (2010) Quantification of myocardial blood flow and flow reserve: technical aspects. J Nucl Cardiol 17:555–570CrossRefPubMed Klein R, Beanlands RSB, deKemp RA (2010) Quantification of myocardial blood flow and flow reserve: technical aspects. J Nucl Cardiol 17:555–570CrossRefPubMed
23.
Zurück zum Zitat Qayyum AA, Kühl JT, Kjaer A et al (2015) Semi-quantitative myocardial perfusion measured by computed tomography in patients with refractory angina: a head-to-head comparison with quantitative rubidium-82 positron emission tomography as reference. Clin Physiol Funct Imaging. https://doi.org/10.1111/cpf.12322 Qayyum AA, Kühl JT, Kjaer A et al (2015) Semi-quantitative myocardial perfusion measured by computed tomography in patients with refractory angina: a head-to-head comparison with quantitative rubidium-82 positron emission tomography as reference. Clin Physiol Funct Imaging. https://​doi.​org/​10.​1111/​cpf.​12322
24.
Zurück zum Zitat Bischoff B, Bamberg F, Marcus R et al (2013) Optimal timing for first-pass stress CT myocardial perfusion imaging. Int J Card Imaging 29:435–442CrossRef Bischoff B, Bamberg F, Marcus R et al (2013) Optimal timing for first-pass stress CT myocardial perfusion imaging. Int J Card Imaging 29:435–442CrossRef
25.
Zurück zum Zitat Koepfli P, Wyss CA, Namdar M et al (2004) Beta-adrenergic blockade and myocardial perfusion in coronary artery disease: differential effects in stenotic versus remote myocardial segments. J Nucl Med 45:1626–1631PubMed Koepfli P, Wyss CA, Namdar M et al (2004) Beta-adrenergic blockade and myocardial perfusion in coronary artery disease: differential effects in stenotic versus remote myocardial segments. J Nucl Med 45:1626–1631PubMed
26.
Zurück zum Zitat Rybicki FJ, Mather RT, Kumamaru KK et al (2015) Comprehensive assessment of radiation dose estimates for the CORE320 study. AJR Am J Roentgenol 204:W27–W36CrossRefPubMed Rybicki FJ, Mather RT, Kumamaru KK et al (2015) Comprehensive assessment of radiation dose estimates for the CORE320 study. AJR Am J Roentgenol 204:W27–W36CrossRefPubMed
27.
Zurück zum Zitat Hoffmann U, Ferencik M, Udelson JE et al (2017) Prognostic value of noninvasive cardiovascular testing in patients with stable chest pain: insights from the PROMISE Trial (Prospective Multicenter Imaging Study for Evaluation of Chest Pain). Circulation 135:2320–2332CrossRefPubMed Hoffmann U, Ferencik M, Udelson JE et al (2017) Prognostic value of noninvasive cardiovascular testing in patients with stable chest pain: insights from the PROMISE Trial (Prospective Multicenter Imaging Study for Evaluation of Chest Pain). Circulation 135:2320–2332CrossRefPubMed
28.
Zurück zum Zitat Feinstein AR, Cicchetti DV (1990) High agreement but low kappa: I. the problems of two paradoxes. J Clin Epidemiol 43:543–549CrossRefPubMed Feinstein AR, Cicchetti DV (1990) High agreement but low kappa: I. the problems of two paradoxes. J Clin Epidemiol 43:543–549CrossRefPubMed
Metadaten
Titel
Myocardial perfusion in patients with suspected coronary artery disease: comparison between 320-MDCT and rubidium-82 PET
verfasst von
Roberto Nery Dantas Jr
Antonildes Nascimento Assuncao Jr
Ismar Aguiar Marques
Mateus Guimaraes Fahel
Cesar Higa Nomura
Luiz Francisco Rodrigues Avila
Maria Clementina Pinto Giorgi
Jose Soares Jr
Jose Claudio Meneghetti
Jose Rodrigues Parga
Publikationsdatum
19.01.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 6/2018
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-017-5257-2

Weitere Artikel der Ausgabe 6/2018

European Radiology 6/2018 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.