Skip to main content
Erschienen in: Herz 5/2013

01.08.2013 | e-Herz: Original article

Non-ECG-gated MDCTA of infracardiac total anomalous pulmonary venous connection in neonates and young infants

verfasst von: Q. Yao, X. Hu, M. Pa, G. Huang

Erschienen in: Herz | Ausgabe 5/2013

Einloggen, um Zugang zu erhalten

Abstract

Objective

To compare the diagnostic accuracy of non-electrocardiogram-gated (non-ECG-gated) multidetector computed tomography angiography (MDCTA) with transthoracic echocardiography (TTE) in the evaluation of infracardiac total anomalous pulmonary venous connection (TAPVC) in neonate and infant patients.

Methods

Nine patients aged from 2 days to 3 months were included in this study. All clinical and imaging data were reviewed. Compared with findings from surgery, the diagnostic accuracy of MDCTA and TTE was calculated in three respects: the path of the drainage vein, the drainage site, and the stenosis of the vein.

Results

Images acquired from all patients were eligible for diagnosis and reconstruction. The sites of the drainage point were all clarified and the drainage vessels were oriented by axial and reconstructed images. Stenosis was found at 13 sites, including mild stenosis at the diaphragmatic level (n = 3), distortion or stenosis at the drainage site (n = 5), and hypogenesis of the pulmonary vein branch (n = 5). TTE misdiagnosed the upward-flowing collateral vessels as the drainage veins in 2 patients and misidentified the drainage site in 7 patients, yielding an accuracy of 77.8% and 22.9%, respectively. It identified stenosis at four sites at the drainage site in concordance with MDCTA. The hypogenesis of the pulmonary vein branch was not detected and the stenosis at the diaphragmatic level was not suggested by TTE.

Conclusion

For infracardiac TAPVC, non-ECG-gated MDCTA is superior to TTE and can facilitate the preoperative evaluation when combined with TTE.
Literatur
1.
Zurück zum Zitat Liu J, Wu Q, Xu Y et al (2012) Role of MDCT angiography in the preoperative evaluation of anomalous pulmonary venous connection associated with complex cardiac abnormality. Eur J Radiol 81:1050–1056PubMedCrossRef Liu J, Wu Q, Xu Y et al (2012) Role of MDCT angiography in the preoperative evaluation of anomalous pulmonary venous connection associated with complex cardiac abnormality. Eur J Radiol 81:1050–1056PubMedCrossRef
2.
Zurück zum Zitat Oh KH, Choo KS, Lim SJ et al (2009) Multidetector CT evaluation of total anomalous pulmonary venous connections: comparison with echocardiography. Pediatr Radiol 39:950–954PubMedCrossRef Oh KH, Choo KS, Lim SJ et al (2009) Multidetector CT evaluation of total anomalous pulmonary venous connections: comparison with echocardiography. Pediatr Radiol 39:950–954PubMedCrossRef
3.
Zurück zum Zitat Kim TH, Kim YM, Suh CH et al (2000) Helical CT angiography and three-dimensional reconstruction of total anomalous pulmonary venous connections in neonates and infants. AJR Am J Roentgenol 175:1381–1386PubMedCrossRef Kim TH, Kim YM, Suh CH et al (2000) Helical CT angiography and three-dimensional reconstruction of total anomalous pulmonary venous connections in neonates and infants. AJR Am J Roentgenol 175:1381–1386PubMedCrossRef
4.
Zurück zum Zitat Seale AN, Uemura H, Webber SA et al (2010) Total anomalous pulmonary venous connection: morphology and outcome from an international population-based study. Circulation 122:2718–2726PubMedCrossRef Seale AN, Uemura H, Webber SA et al (2010) Total anomalous pulmonary venous connection: morphology and outcome from an international population-based study. Circulation 122:2718–2726PubMedCrossRef
5.
Zurück zum Zitat Hausleiter J, Meyer T, Hermann F et al (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301:500–507PubMedCrossRef Hausleiter J, Meyer T, Hermann F et al (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301:500–507PubMedCrossRef
6.
Zurück zum Zitat Dillman JR, Yarram SG, Hernandez RJ (2009) Imaging of pulmonary venous developmental anomalies. AJR Am J Roentgenol 192:1272–1285PubMedCrossRef Dillman JR, Yarram SG, Hernandez RJ (2009) Imaging of pulmonary venous developmental anomalies. AJR Am J Roentgenol 192:1272–1285PubMedCrossRef
7.
Zurück zum Zitat Van Son JA, Hambsch J, Kinzel P et al (2000) Urgency of operation in infracardiac total anomalous pulmonary venous connection. Ann Thorac Surg 70:128–130CrossRef Van Son JA, Hambsch J, Kinzel P et al (2000) Urgency of operation in infracardiac total anomalous pulmonary venous connection. Ann Thorac Surg 70:128–130CrossRef
8.
Zurück zum Zitat Roest A, Roos A de (2011) Imaging of patients with congenital heart disease. Nat Rev Cardiol 9:101–115PubMedCrossRef Roest A, Roos A de (2011) Imaging of patients with congenital heart disease. Nat Rev Cardiol 9:101–115PubMedCrossRef
9.
Zurück zum Zitat Schertler T, Wildermuth S, Teodorovic N et al (2007) Visualization of congenital thoracic vascular anomalies using multi-detector row computed tomography and two- and three-dimensional post-processing. Eur J Radiol 61:97–119PubMedCrossRef Schertler T, Wildermuth S, Teodorovic N et al (2007) Visualization of congenital thoracic vascular anomalies using multi-detector row computed tomography and two- and three-dimensional post-processing. Eur J Radiol 61:97–119PubMedCrossRef
10.
Zurück zum Zitat Herzog C, Wimmer-Greinecker G, Schwarz W et al (2004) Progress in CT imaging for the cardiac surgeon. Semin Thorac Cardiovasc Surg 16:242–248PubMedCrossRef Herzog C, Wimmer-Greinecker G, Schwarz W et al (2004) Progress in CT imaging for the cardiac surgeon. Semin Thorac Cardiovasc Surg 16:242–248PubMedCrossRef
11.
Zurück zum Zitat Johnson KM, Dennis JM, Dowe DA (2010) Extracardiac findings on coronary CT angiograms: limited versus complete image review. AJR Am J Roentgenol 195:143–148PubMedCrossRef Johnson KM, Dennis JM, Dowe DA (2010) Extracardiac findings on coronary CT angiograms: limited versus complete image review. AJR Am J Roentgenol 195:143–148PubMedCrossRef
12.
Zurück zum Zitat Kawano T, Ishii M, Takagi J (2000) Three-dimensional helical computed tomographic angiography in neonates and infants with complex congenital heart disease. Am Heart J 139:654–660PubMedCrossRef Kawano T, Ishii M, Takagi J (2000) Three-dimensional helical computed tomographic angiography in neonates and infants with complex congenital heart disease. Am Heart J 139:654–660PubMedCrossRef
13.
Zurück zum Zitat Ou P, Marini D, Celermajer DS et al (2009) Non-invasive assessment of congenital pulmonary vein stenosis in children using cardiac-non-gated CT with 64-slice technology. Eur J Radiol 70:595–599PubMedCrossRef Ou P, Marini D, Celermajer DS et al (2009) Non-invasive assessment of congenital pulmonary vein stenosis in children using cardiac-non-gated CT with 64-slice technology. Eur J Radiol 70:595–599PubMedCrossRef
14.
Zurück zum Zitat Long YG, Yang YY, Huang IL et al (2010) Role of multi-slice and three-dimensional computed tomography in delineating extracardiac vascular abnormalities in neonates. Pediatr Neonatol 51:227–234PubMedCrossRef Long YG, Yang YY, Huang IL et al (2010) Role of multi-slice and three-dimensional computed tomography in delineating extracardiac vascular abnormalities in neonates. Pediatr Neonatol 51:227–234PubMedCrossRef
15.
Zurück zum Zitat Ferrari VA, Scott CH, Holland GA et al (2001) Ultrafast three-dimensional contrast-enhanced magnetic resonance angiography and imaging in the diagnosis of partial anomalous pulmonary venous drainage. J Am Coll Cardiol 37:1120–1128PubMedCrossRef Ferrari VA, Scott CH, Holland GA et al (2001) Ultrafast three-dimensional contrast-enhanced magnetic resonance angiography and imaging in the diagnosis of partial anomalous pulmonary venous drainage. J Am Coll Cardiol 37:1120–1128PubMedCrossRef
16.
Zurück zum Zitat Kirpalani H, Nahmias C (2008) Radiation risk to children from computed tomography. Pediatrics 121:449–450PubMedCrossRef Kirpalani H, Nahmias C (2008) Radiation risk to children from computed tomography. Pediatrics 121:449–450PubMedCrossRef
17.
Zurück zum Zitat Tsai IC, Chen MC, Jan SL et al (2008) Neonatal cardiac multidetector row CT: why and how we do it. Pediatr Radiol 38:438–451PubMedCrossRef Tsai IC, Chen MC, Jan SL et al (2008) Neonatal cardiac multidetector row CT: why and how we do it. Pediatr Radiol 38:438–451PubMedCrossRef
Metadaten
Titel
Non-ECG-gated MDCTA of infracardiac total anomalous pulmonary venous connection in neonates and young infants
verfasst von
Q. Yao
X. Hu
M. Pa
G. Huang
Publikationsdatum
01.08.2013
Verlag
Urban & Vogel
Erschienen in
Herz / Ausgabe 5/2013
Print ISSN: 0340-9937
Elektronische ISSN: 1615-6692
DOI
https://doi.org/10.1007/s00059-012-3728-4

Weitere Artikel der Ausgabe 5/2013

Herz 5/2013 Zur Ausgabe

„Jeder Fall von plötzlichem Tod muss obduziert werden!“

17.05.2024 Plötzlicher Herztod Nachrichten

Ein signifikanter Anteil der Fälle von plötzlichem Herztod ist genetisch bedingt. Um ihre Verwandten vor diesem Schicksal zu bewahren, sollten jüngere Personen, die plötzlich unerwartet versterben, ausnahmslos einer Autopsie unterzogen werden.

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Schlechtere Vorhofflimmern-Prognose bei kleinem linken Ventrikel

17.05.2024 Vorhofflimmern Nachrichten

Nicht nur ein vergrößerter, sondern auch ein kleiner linker Ventrikel ist bei Vorhofflimmern mit einer erhöhten Komplikationsrate assoziiert. Der Zusammenhang besteht nach Daten aus China unabhängig von anderen Risikofaktoren.

Semaglutid bei Herzinsuffizienz: Wie erklärt sich die Wirksamkeit?

17.05.2024 Herzinsuffizienz Nachrichten

Bei adipösen Patienten mit Herzinsuffizienz des HFpEF-Phänotyps ist Semaglutid von symptomatischem Nutzen. Resultiert dieser Benefit allein aus der Gewichtsreduktion oder auch aus spezifischen Effekten auf die Herzinsuffizienz-Pathogenese? Eine neue Analyse gibt Aufschluss.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.