The implantable cardioverter-defibrillator (ICD) is the most effective therapy to prevent sudden cardiac death (SCD) in high-risk patients. To overcome infections and failure of transvenous leads, the most frightening complications of conventional ICDs, a completely subcutaneous ICD (S-ICD) has been developed and is currently adopted in routine clinical practice. In view of their long life-expectancy, low competitive risk of dying from non-arrhythmic causes, and high lifetime risk of lead-related complications requiring surgical revisions, young patients with cardiomyopathies and inherited arrhythmia syndromes have traditionally been considered ideal candidates for the S-ICD. However, as growing evidence supported S-ICD safety and efficacy, initial niche implant indications were abandoned in favor of a widespread use of this technology, that is currently adopted in common ICD candidates with severe left ventricular dysfunction. Indeed, guidelines recommend S-ICD implantation as an alternative to TV-ICDs in all ICD candidates, unless pacing is required. This review focuses on the contemporary experience with the S-ICD and explores future scenarios in which device-to-device communication will enable to combine leadless therapies.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Priori SG, Blomstrom-Lundqvist C, Mazzanti A, Bloma N, Borggrefe M, Camm J, Elliott PM, et al. ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death the Task Force for the Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death of the European. Eur Heart J. 2015;2015:2793–867.CrossRef Priori SG, Blomstrom-Lundqvist C, Mazzanti A, Bloma N, Borggrefe M, Camm J, Elliott PM, et al. ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death the Task Force for the Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death of the European. Eur Heart J. 2015;2015:2793–867.CrossRef
2.
Zurück zum Zitat Moss AJ, Hall WJ, Cannom D, Daubert J, Higgins S, Klein H, Levine J. Improved survival with an implanted defibrillator in patients. N Engl J Med. 1996;335(26):1933–40.PubMedCrossRef Moss AJ, Hall WJ, Cannom D, Daubert J, Higgins S, Klein H, Levine J. Improved survival with an implanted defibrillator in patients. N Engl J Med. 1996;335(26):1933–40.PubMedCrossRef
3.
Zurück zum Zitat Adduci C, Ali H, Francia P, Mantovani R, Palano F, Lupo P, Foresti S, et al. The subcutaneous implantable cardioverter-defibrillator: current trends in clinical practice between guidelines and technology progress. Eur J Intern Med. 2019. Adduci C, Ali H, Francia P, Mantovani R, Palano F, Lupo P, Foresti S, et al. The subcutaneous implantable cardioverter-defibrillator: current trends in clinical practice between guidelines and technology progress. Eur J Intern Med. 2019.
4.
Zurück zum Zitat Van Rees JB, De Bie MK, Thijssen J, Borleffs CJW, Schalij MJ, Van Erven L. Implantation-related complications of implantable cardioverter-defibrillators and cardiac resynchronization therapy devices: a systematic review of randomized clinical trials. J Am Coll Cardiol. 2011;58:995–1000.PubMedCrossRef Van Rees JB, De Bie MK, Thijssen J, Borleffs CJW, Schalij MJ, Van Erven L. Implantation-related complications of implantable cardioverter-defibrillators and cardiac resynchronization therapy devices: a systematic review of randomized clinical trials. J Am Coll Cardiol. 2011;58:995–1000.PubMedCrossRef
5.
Zurück zum Zitat Kleemann T, Becker T, Doenges K, Vater M, Senges J, Schneider S, Saggau W, et al. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years. Circulation. 2007;115(19):2474–80.PubMedCrossRef Kleemann T, Becker T, Doenges K, Vater M, Senges J, Schneider S, Saggau W, et al. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years. Circulation. 2007;115(19):2474–80.PubMedCrossRef
7.
Zurück zum Zitat Migliore F, Mattesi G, Zorzi A, Viani S, Bongiorni MG, Francia P, Curcio A, et al. The subcutaneous implantable cardioverter- defibrillator in clinical practice. Giornale Ital Cardiol. 2019. 641–550. Migliore F, Mattesi G, Zorzi A, Viani S, Bongiorni MG, Francia P, Curcio A, et al. The subcutaneous implantable cardioverter- defibrillator in clinical practice. Giornale Ital Cardiol. 2019. 641–550.
9.
Zurück zum Zitat Francia P, Ziacchi M, De Filippo P, Viani S, D’Onofrio A, Russo V, Adduci C, et al. Subcutaneous implantable cardioverter defibrillator eligibility according to a novel automated screening tool and agreement with the standard manual electrocardiographic morphology tool. J Interv Card Electrophysiol. 2018;52(1):61–7.PubMedCrossRef Francia P, Ziacchi M, De Filippo P, Viani S, D’Onofrio A, Russo V, Adduci C, et al. Subcutaneous implantable cardioverter defibrillator eligibility according to a novel automated screening tool and agreement with the standard manual electrocardiographic morphology tool. J Interv Card Electrophysiol. 2018;52(1):61–7.PubMedCrossRef
10.
Zurück zum Zitat Knops RE, Olde Nordkamp LRA, De Groot JR, Wilde AAM. Two-incision technique for implantation of the subcutaneous implantable cardioverter-defibrillator. Hear Rhythm. 2013;10(8):1240–3.CrossRef Knops RE, Olde Nordkamp LRA, De Groot JR, Wilde AAM. Two-incision technique for implantation of the subcutaneous implantable cardioverter-defibrillator. Hear Rhythm. 2013;10(8):1240–3.CrossRef
11.
Zurück zum Zitat Migliore F, Allocca G, Calzolari V, Crosato M, Facchin D, Daleffe E, Zecchin M, et al. Intermuscular two-incision technique for subcutaneous implantable cardioverter defibrillator implantation: results from a multicenter registry. PACE Pacing Clin Electrophysiol. 2017;40:278–85.PubMedCrossRef Migliore F, Allocca G, Calzolari V, Crosato M, Facchin D, Daleffe E, Zecchin M, et al. Intermuscular two-incision technique for subcutaneous implantable cardioverter defibrillator implantation: results from a multicenter registry. PACE Pacing Clin Electrophysiol. 2017;40:278–85.PubMedCrossRef
12.
Zurück zum Zitat Gold MR, Aasbo JD, El-Chami MF, Niebauer M, Herre J, Prutkin JM, Knight BP, et al. Subcutaneous implantable cardioverter-defibrillator post-approval study: clinical characteristics and perioperative results. Hear Rhythm. 2017;14(10):1456–63.CrossRef Gold MR, Aasbo JD, El-Chami MF, Niebauer M, Herre J, Prutkin JM, Knight BP, et al. Subcutaneous implantable cardioverter-defibrillator post-approval study: clinical characteristics and perioperative results. Hear Rhythm. 2017;14(10):1456–63.CrossRef
13.
Zurück zum Zitat Friedman DJ, Parzynski CS, Varosy PD, Prutkin JM, Patton KK, Mithani A, Russo AM, et al. Trends and in-hospital outcomes associated with adoption of the subcutaneous implantable cardioverter defibrillator in the United States. JAMA Cardiol. 2016;1(8):900–11.PubMedPubMedCentralCrossRef Friedman DJ, Parzynski CS, Varosy PD, Prutkin JM, Patton KK, Mithani A, Russo AM, et al. Trends and in-hospital outcomes associated with adoption of the subcutaneous implantable cardioverter defibrillator in the United States. JAMA Cardiol. 2016;1(8):900–11.PubMedPubMedCentralCrossRef
14.
Zurück zum Zitat Boersma L, Barr C, Knops R, Theuns D, Eckardt L, Neuzil P, Scholten M, et al. Implant and midterm outcomes of the subcutaneous implantable cardioverter-defibrillator registry: the EFFORTLESS study. J Am Coll Cardiol. 2017;70(7):830–41.PubMedCrossRef Boersma L, Barr C, Knops R, Theuns D, Eckardt L, Neuzil P, Scholten M, et al. Implant and midterm outcomes of the subcutaneous implantable cardioverter-defibrillator registry: the EFFORTLESS study. J Am Coll Cardiol. 2017;70(7):830–41.PubMedCrossRef
15.
Zurück zum Zitat D’Onofrio A, Pieragnoli P, Biffi M, Nigro G, Migliore F, Francia P, De Filippo P, et al. Subcutaneous implantable cardioverter defibrillator implantation: an analysis of Italian clinical practice and its evolution. Int J Cardiol. 2018;162–7. D’Onofrio A, Pieragnoli P, Biffi M, Nigro G, Migliore F, Francia P, De Filippo P, et al. Subcutaneous implantable cardioverter defibrillator implantation: an analysis of Italian clinical practice and its evolution. Int J Cardiol. 2018;162–7.
16.
Zurück zum Zitat Diemberger I, Migliore F, Ricciardi G, Ottaviano L, Tavoletta V, Francia P, Viani S, et al. Time to therapy delivery and effectiveness of the subcutaneous implantable cardioverter-defibrillator. Hear Rhythm. 2019;16(10):1531–7.CrossRef Diemberger I, Migliore F, Ricciardi G, Ottaviano L, Tavoletta V, Francia P, Viani S, et al. Time to therapy delivery and effectiveness of the subcutaneous implantable cardioverter-defibrillator. Hear Rhythm. 2019;16(10):1531–7.CrossRef
17.
Zurück zum Zitat Adduci C, Spadoni L, Palano F, Francia P. Ventricular fibrillation undersensing due to air entrapment in a patient implanted with a subcutaneous cardioverter defibrillator. J Cardiovasc Electrophysiol. 2019;30(8):1373–4.PubMedCrossRef Adduci C, Spadoni L, Palano F, Francia P. Ventricular fibrillation undersensing due to air entrapment in a patient implanted with a subcutaneous cardioverter defibrillator. J Cardiovasc Electrophysiol. 2019;30(8):1373–4.PubMedCrossRef
18.
Zurück zum Zitat Quast AFBE, Baalman SWE, Brouwer TF, Smeding L, Wilde AAM, Burke MC, Knops RE. A novel tool to evaluate the implant position and predict defibrillation success of the subcutaneous implantable cardioverter-defibrillator: the PRAETORIAN score. Hear Rhythm. 2019;16:403–10.CrossRef Quast AFBE, Baalman SWE, Brouwer TF, Smeding L, Wilde AAM, Burke MC, Knops RE. A novel tool to evaluate the implant position and predict defibrillation success of the subcutaneous implantable cardioverter-defibrillator: the PRAETORIAN score. Hear Rhythm. 2019;16:403–10.CrossRef
19.
Zurück zum Zitat Quast AFBE, Baalman SWE, Betts TR, Boersma LVA, Bonnemeier H, Boveda S, Brouwer TF, et al. Rationale and design of the PRAETORIAN-DFT trial: a prospective randomized comparative trial of subcutaneous implantable cardioverter-defibrillator implantation with and without defibrillation testing. Am Heart J. 2019;214:167–74.PubMedCrossRef Quast AFBE, Baalman SWE, Betts TR, Boersma LVA, Bonnemeier H, Boveda S, Brouwer TF, et al. Rationale and design of the PRAETORIAN-DFT trial: a prospective randomized comparative trial of subcutaneous implantable cardioverter-defibrillator implantation with and without defibrillation testing. Am Heart J. 2019;214:167–74.PubMedCrossRef
20.
Zurück zum Zitat Al-Khatib SM, Stevenson WG, Ackerman MJ, Bryant WJ, Callans DJ, Curtis AB, Deal BJ, et al. 2017 AHA/ACC/HRS guideline for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: executive summary. Circulation. 2018;138:e272–391.PubMed Al-Khatib SM, Stevenson WG, Ackerman MJ, Bryant WJ, Callans DJ, Curtis AB, Deal BJ, et al. 2017 AHA/ACC/HRS guideline for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: executive summary. Circulation. 2018;138:e272–391.PubMed
21.
Zurück zum Zitat Weiss R, Knight BP, Gold MR, Leon AR, Herre JM, Hood M, Rashtian M, et al. Safety and efficacy of a totally subcutaneous implantable-cardioverter defibrillator. Circulation. 2013;128(9):944–53.PubMedCrossRef Weiss R, Knight BP, Gold MR, Leon AR, Herre JM, Hood M, Rashtian M, et al. Safety and efficacy of a totally subcutaneous implantable-cardioverter defibrillator. Circulation. 2013;128(9):944–53.PubMedCrossRef
22.
Zurück zum Zitat Lambiase PD, Barr C, Theuns DAMJ, Knops R, Neuzil P, Johansen JB, Hood M, et al. Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD registry. Eur Heart J. 2014;35(25):1657–65.PubMedPubMedCentralCrossRef Lambiase PD, Barr C, Theuns DAMJ, Knops R, Neuzil P, Johansen JB, Hood M, et al. Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD registry. Eur Heart J. 2014;35(25):1657–65.PubMedPubMedCentralCrossRef
23.
Zurück zum Zitat Quast AFBE, van Dijk VF, Yap SC, Maass AH, Boersma LVA, Theuns DA, Knops RE. Six-year follow-up of the initial Dutch subcutaneous implantable cardioverter-defibrillator cohort: long-term complications, replacements, and battery longevity. J Cardiovasc Electrophysiol. 2018;29(7):1010–6.PubMedCrossRef Quast AFBE, van Dijk VF, Yap SC, Maass AH, Boersma LVA, Theuns DA, Knops RE. Six-year follow-up of the initial Dutch subcutaneous implantable cardioverter-defibrillator cohort: long-term complications, replacements, and battery longevity. J Cardiovasc Electrophysiol. 2018;29(7):1010–6.PubMedCrossRef
24.
Zurück zum Zitat Francia P, Adduci C, Palano F, Semprini L, Serdoz A, Montesanti D, Santini D, et al. Eligibility for the subcutaneous implantable cardioverter-defibrillator in patients with hypertrophic cardiomyopathy. J Cardiovasc Electrophysiol. 2015;26(8):893–9.PubMedCrossRef Francia P, Adduci C, Palano F, Semprini L, Serdoz A, Montesanti D, Santini D, et al. Eligibility for the subcutaneous implantable cardioverter-defibrillator in patients with hypertrophic cardiomyopathy. J Cardiovasc Electrophysiol. 2015;26(8):893–9.PubMedCrossRef
25.
Zurück zum Zitat Srinivasan NT, Patel KH, Qamar K, Taylor A, Bacà M, Providência R, Tome-Esteban M, et al. Disease severity and exercise testing reduce subcutaneous implantable cardioverter-defibrillator left sternal ECG screening success in hypertrophic cardiomyopathy. Circ Arrhythmia Electrophysiol. 2017;10(4). Srinivasan NT, Patel KH, Qamar K, Taylor A, Bacà M, Providência R, Tome-Esteban M, et al. Disease severity and exercise testing reduce subcutaneous implantable cardioverter-defibrillator left sternal ECG screening success in hypertrophic cardiomyopathy. Circ Arrhythmia Electrophysiol. 2017;10(4).
26.
Zurück zum Zitat De Bie MK, Thijssen J, Van Rees JB, Putter H, Van Der Velde ET, Schalij MJ, Van Erven L. Suitability for subcutaneous defibrillator implantation: results based on data from routine clinical practice. Heart. 2013;99(14):1018–23.PubMedCrossRef De Bie MK, Thijssen J, Van Rees JB, Putter H, Van Der Velde ET, Schalij MJ, Van Erven L. Suitability for subcutaneous defibrillator implantation: results based on data from routine clinical practice. Heart. 2013;99(14):1018–23.PubMedCrossRef
27.
Zurück zum Zitat Melles MC, Yap SC, Bhagwandien RE, Sakhi R, Szili-Torok T, Theuns DAMJ. Frequency of need for antitachycardia or antibradycardia pacing or cardiac resynchronization therapy in patients with a single-chamber implantable cardioverter-defibrillator. Am J Cardiol. 2018;122(12):2068–74.PubMedCrossRef Melles MC, Yap SC, Bhagwandien RE, Sakhi R, Szili-Torok T, Theuns DAMJ. Frequency of need for antitachycardia or antibradycardia pacing or cardiac resynchronization therapy in patients with a single-chamber implantable cardioverter-defibrillator. Am J Cardiol. 2018;122(12):2068–74.PubMedCrossRef
28.
Zurück zum Zitat Boersma LV, El-Chami MF, Bongiorni MG, Burke MC, Knops RE, Aasbo JD, Lambiase PD, et al. Understanding outcomes with the EMBLEM S-ICD in primary prevention patients with low EF study (UNTOUCHED): clinical characteristics and perioperative results. Hear Rhythm. 2019;16(11):1636–44.CrossRef Boersma LV, El-Chami MF, Bongiorni MG, Burke MC, Knops RE, Aasbo JD, Lambiase PD, et al. Understanding outcomes with the EMBLEM S-ICD in primary prevention patients with low EF study (UNTOUCHED): clinical characteristics and perioperative results. Hear Rhythm. 2019;16(11):1636–44.CrossRef
29.
Zurück zum Zitat Maron BJ, Casey SA, Olivotto I, Sherrid M V., Semsarian C, Autore C, Ahmed A, et al. Clinical course and quality of life in high-risk patients with hypertrophic cardiomyopathy and implantable cardioverter-defibrillators. Circ Arrhythmia Electrophysiol. 2018;11(4). Maron BJ, Casey SA, Olivotto I, Sherrid M V., Semsarian C, Autore C, Ahmed A, et al. Clinical course and quality of life in high-risk patients with hypertrophic cardiomyopathy and implantable cardioverter-defibrillators. Circ Arrhythmia Electrophysiol. 2018;11(4).
30.
Zurück zum Zitat Migliore F, Pelliccia F, Autore C, Bertaglia E, Cecchi F, Curcio A, Bontempi L, et al. Subcutaneous implantable cardioverter defibrillator in cardiomyopathies and channelopathies. J Cardiovasc Med. 2018. 633–42. Migliore F, Pelliccia F, Autore C, Bertaglia E, Cecchi F, Curcio A, Bontempi L, et al. Subcutaneous implantable cardioverter defibrillator in cardiomyopathies and channelopathies. J Cardiovasc Med. 2018. 633–42.
31.
Zurück zum Zitat Olde Nordkamp LRA, Postema PG, Knops RE, Van Dijk N, Limpens J, Wilde AAM, De Groot JR. Implantable cardioverter-defibrillator harm in young patients with inherited arrhythmia syndromes: a systematic review and meta-analysis of inappropriate shocks and complications. Hear Rhythm. 2016;13(2):443–54.CrossRef Olde Nordkamp LRA, Postema PG, Knops RE, Van Dijk N, Limpens J, Wilde AAM, De Groot JR. Implantable cardioverter-defibrillator harm in young patients with inherited arrhythmia syndromes: a systematic review and meta-analysis of inappropriate shocks and complications. Hear Rhythm. 2016;13(2):443–54.CrossRef
32.
Zurück zum Zitat Roberts BD, Hood RE, Saba MM, Dickfeld TM, Saliaris AP, Shorofsky SR. Defibrillation threshold testing in patients with hypertrophic cardiomyopathy. PACE Pacing Clin Electrophysiol. 2010;33(11):1342–6.PubMedCrossRef Roberts BD, Hood RE, Saba MM, Dickfeld TM, Saliaris AP, Shorofsky SR. Defibrillation threshold testing in patients with hypertrophic cardiomyopathy. PACE Pacing Clin Electrophysiol. 2010;33(11):1342–6.PubMedCrossRef
33.
Zurück zum Zitat Francia P, Adduci C, Semprini L, Palano F, Santini D, Musumeci B, Santolamazza C, et al. Prognostic implications of defibrillation threshold testing in patients with hypertrophic cardiomyopathy. J Cardiovasc Electrophysiol. 2017;28(1):103–8.PubMedCrossRef Francia P, Adduci C, Semprini L, Palano F, Santini D, Musumeci B, Santolamazza C, et al. Prognostic implications of defibrillation threshold testing in patients with hypertrophic cardiomyopathy. J Cardiovasc Electrophysiol. 2017;28(1):103–8.PubMedCrossRef
34.
Zurück zum Zitat Weinstock J, Bader YH, Maron MS, Rowin EJ, Link MS. Subcutaneous implantable cardioverter defibrillator in patients with hypertrophic cardiomyopathy: an initial experience. J Am Heart Assoc. 2016;5(2):1–6.CrossRef Weinstock J, Bader YH, Maron MS, Rowin EJ, Link MS. Subcutaneous implantable cardioverter defibrillator in patients with hypertrophic cardiomyopathy: an initial experience. J Am Heart Assoc. 2016;5(2):1–6.CrossRef
35.
Zurück zum Zitat Friedman DJ, Parzynski CS, Heist EK, Russo AM, Akar JG, Freeman JV, Curtis JP, et al. Ventricular fibrillation conversion testing after implantation of a subcutaneous implantable cardioverter defibrillator report from the national cardiovascular data registry. Circulation. 2018;137:2463–77.PubMedPubMedCentralCrossRef Friedman DJ, Parzynski CS, Heist EK, Russo AM, Akar JG, Freeman JV, Curtis JP, et al. Ventricular fibrillation conversion testing after implantation of a subcutaneous implantable cardioverter defibrillator report from the national cardiovascular data registry. Circulation. 2018;137:2463–77.PubMedPubMedCentralCrossRef
36.
Zurück zum Zitat Maurizi N, Tanini I, Olivotto I, Amendola E, Limongelli G, Losi MA, Allocca G, et al. Effectiveness of subcutaneous implantable cardioverter-defibrillator testing in patients with hypertrophic cardiomyopathy. Int J Cardiol. 2017;231:115–9.PubMedCrossRef Maurizi N, Tanini I, Olivotto I, Amendola E, Limongelli G, Losi MA, Allocca G, et al. Effectiveness of subcutaneous implantable cardioverter-defibrillator testing in patients with hypertrophic cardiomyopathy. Int J Cardiol. 2017;231:115–9.PubMedCrossRef
37.
Zurück zum Zitat Lambiase PD, Gold MR, Hood M, Boersma L, Theuns DAMJ, Burke MC, Weiss R, et al. Evaluation of subcutaneous ICD early performance in hypertrophic cardiomyopathy from the pooled EFFORTLESS and IDE cohorts. Hear Rhythm. 2016;13(5):1066–74.CrossRef Lambiase PD, Gold MR, Hood M, Boersma L, Theuns DAMJ, Burke MC, Weiss R, et al. Evaluation of subcutaneous ICD early performance in hypertrophic cardiomyopathy from the pooled EFFORTLESS and IDE cohorts. Hear Rhythm. 2016;13(5):1066–74.CrossRef
38.
Zurück zum Zitat Maurizi N, Olivotto I, Olde Nordkamp LRA, Baldini K, Fumagalli C, Brouwer TF, Knops RE, et al. Prevalence of subcutaneous implantable cardioverter-defibrillator candidacy based on template ECG screening in patients with hypertrophic cardiomyopathy. Hear Rhythm. 2016;13(2):457–63.CrossRef Maurizi N, Olivotto I, Olde Nordkamp LRA, Baldini K, Fumagalli C, Brouwer TF, Knops RE, et al. Prevalence of subcutaneous implantable cardioverter-defibrillator candidacy based on template ECG screening in patients with hypertrophic cardiomyopathy. Hear Rhythm. 2016;13(2):457–63.CrossRef
39.
Zurück zum Zitat Sakhi R, Yap SC, Michels M, Schinkel AFL, Kauling RM, Roos-Hesselink JW, Theuns DAMJ. Evaluation of a novel automatic screening tool for determining eligibility for a subcutaneous implantable cardioverter-defibrillator. Int J Cardiol. 2018;272(1):97–101.PubMedCrossRef Sakhi R, Yap SC, Michels M, Schinkel AFL, Kauling RM, Roos-Hesselink JW, Theuns DAMJ. Evaluation of a novel automatic screening tool for determining eligibility for a subcutaneous implantable cardioverter-defibrillator. Int J Cardiol. 2018;272(1):97–101.PubMedCrossRef
40.
Zurück zum Zitat Nazer B, Dale Z, Carrassa G, Reza N, Ustunkaya T, Papoutsidakis N, Gray A, et al. Appropriate and inappropriate shocks in hypertrophic cardiomyopathy patients with subcutaneous implantable cardioverter-defibrillators: an international multicenter study. Hear Rhythm. 2020;18. Nazer B, Dale Z, Carrassa G, Reza N, Ustunkaya T, Papoutsidakis N, Gray A, et al. Appropriate and inappropriate shocks in hypertrophic cardiomyopathy patients with subcutaneous implantable cardioverter-defibrillators: an international multicenter study. Hear Rhythm. 2020;18.
41.
Zurück zum Zitat Migliore F, Viani S, Bongiorni MG, Zorzi A, Silvetti MS, Francia P, D’Onofrio A, et al. Subcutaneous implantable cardioverter defibrillator in patients with arrhythmogenic right ventricular cardiomyopathy: results from an Italian multicenter registry. Int J Cardiol. 2019;1(280):74–9.CrossRef Migliore F, Viani S, Bongiorni MG, Zorzi A, Silvetti MS, Francia P, D’Onofrio A, et al. Subcutaneous implantable cardioverter defibrillator in patients with arrhythmogenic right ventricular cardiomyopathy: results from an Italian multicenter registry. Int J Cardiol. 2019;1(280):74–9.CrossRef
42.
Zurück zum Zitat Corrado D, Zorzi A, Cerrone M, Rigato I, Mongillo M, Bauce B, Delmar M. Relationship between arrhythmogenic right ventricular cardiomyopathy and brugada syndrome. Circ Arrhythmia Electrophysiol. 2016;9(4). Corrado D, Zorzi A, Cerrone M, Rigato I, Mongillo M, Bauce B, Delmar M. Relationship between arrhythmogenic right ventricular cardiomyopathy and brugada syndrome. Circ Arrhythmia Electrophysiol. 2016;9(4).
43.
Zurück zum Zitat Rudic B, Tülümen E, Berlin V, Röger S, Stach K, Liebe V, El-Battrawy I, et al. Low Prevalence of inappropriate shocks in patients with inherited arrhythmia syndromes with the subcutaneous implantable defibrillator single center experience and long-term follow-up. J Am Heart Assoc. 2017;6(10). Rudic B, Tülümen E, Berlin V, Röger S, Stach K, Liebe V, El-Battrawy I, et al. Low Prevalence of inappropriate shocks in patients with inherited arrhythmia syndromes with the subcutaneous implantable defibrillator single center experience and long-term follow-up. J Am Heart Assoc. 2017;6(10).
44.
Zurück zum Zitat Olde Nordkamp LRA, Conte G, Rosenmöller BRAM, Warnaars JLF, Tan HL, Caputo ML, Regoli F, et al. Brugada syndrome and the subcutaneous implantable cardioverter-defibrillator. J Am Coll Cardiol. 2016. 665–6. Olde Nordkamp LRA, Conte G, Rosenmöller BRAM, Warnaars JLF, Tan HL, Caputo ML, Regoli F, et al. Brugada syndrome and the subcutaneous implantable cardioverter-defibrillator. J Am Coll Cardiol. 2016. 665–6.
45.
Zurück zum Zitat Conte G, Kawabata M, De Asmundis C, Taravelli E, Petracca F, Ruggiero D, Caputo ML, et al. High rate of subcutaneous implantable cardioverter-defibrillator sensing screening failure in patients with Brugada syndrome: a comparison with other inherited primary arrhythmia syndromes. Europace. 2018;20(7):1188–93.PubMedCrossRef Conte G, Kawabata M, De Asmundis C, Taravelli E, Petracca F, Ruggiero D, Caputo ML, et al. High rate of subcutaneous implantable cardioverter-defibrillator sensing screening failure in patients with Brugada syndrome: a comparison with other inherited primary arrhythmia syndromes. Europace. 2018;20(7):1188–93.PubMedCrossRef
46.
Zurück zum Zitat Bögeholz N, Pauls P, Güner F, Bode N, Fischer A, Dechering D, Frommeyer G, et al. Direct comparison of the novel automated screening tool (AST) versus the manual screening tool (MST) in patients with already implanted subcutaneous ICD. Int J Cardiol. 2018;265:90–6.PubMedCrossRef Bögeholz N, Pauls P, Güner F, Bode N, Fischer A, Dechering D, Frommeyer G, et al. Direct comparison of the novel automated screening tool (AST) versus the manual screening tool (MST) in patients with already implanted subcutaneous ICD. Int J Cardiol. 2018;265:90–6.PubMedCrossRef
48.
Zurück zum Zitat Tjong FVY, Brouwer TF, Kooiman KM, Smeding L, Koop B, Soltis B, Shuros A, et al. Communicating antitachycardia pacing-enabled leadless pacemaker and subcutaneous implantable defibrillator. J Am Coll Cardiol. 2016. 1865–6. Tjong FVY, Brouwer TF, Kooiman KM, Smeding L, Koop B, Soltis B, Shuros A, et al. Communicating antitachycardia pacing-enabled leadless pacemaker and subcutaneous implantable defibrillator. J Am Coll Cardiol. 2016. 1865–6.
49.
Zurück zum Zitat Tjong FVY, Brouwer TF, Koop B, Soltis B, Shuros A, Schmidt B, Swackhamer B, et al. Acute and 3-month performance of a communicating leadless antitachycardia pacemaker and subcutaneous implantable defibrillator. JACC Clin Electrophysiol. 2017;3(13):1487–98.PubMedCrossRef Tjong FVY, Brouwer TF, Koop B, Soltis B, Shuros A, Schmidt B, Swackhamer B, et al. Acute and 3-month performance of a communicating leadless antitachycardia pacemaker and subcutaneous implantable defibrillator. JACC Clin Electrophysiol. 2017;3(13):1487–98.PubMedCrossRef
Metadaten
Titel
Prevention of Sudden Cardiac Death: Focus on the Subcutaneous Implantable Cardioverter-Defibrillator
verfasst von
Carmen Adduci
Francesca Palano
Giacomo Silvetti
Pietro Cosentino
Pietro Francia
Publikationsdatum
01.08.2020
Verlag
Springer International Publishing
Erschienen in
High Blood Pressure & Cardiovascular Prevention / Ausgabe 4/2020
Print ISSN: 1120-9879
Elektronische ISSN: 1179-1985
DOI
https://doi.org/10.1007/s40292-020-00394-x

Weitere Artikel der Ausgabe 4/2020

High Blood Pressure & Cardiovascular Prevention 4/2020 Zur Ausgabe

„Jeder Fall von plötzlichem Tod muss obduziert werden!“

17.05.2024 Plötzlicher Herztod Nachrichten

Ein signifikanter Anteil der Fälle von plötzlichem Herztod ist genetisch bedingt. Um ihre Verwandten vor diesem Schicksal zu bewahren, sollten jüngere Personen, die plötzlich unerwartet versterben, ausnahmslos einer Autopsie unterzogen werden.

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Schlechtere Vorhofflimmern-Prognose bei kleinem linken Ventrikel

17.05.2024 Vorhofflimmern Nachrichten

Nicht nur ein vergrößerter, sondern auch ein kleiner linker Ventrikel ist bei Vorhofflimmern mit einer erhöhten Komplikationsrate assoziiert. Der Zusammenhang besteht nach Daten aus China unabhängig von anderen Risikofaktoren.

Semaglutid bei Herzinsuffizienz: Wie erklärt sich die Wirksamkeit?

17.05.2024 Herzinsuffizienz Nachrichten

Bei adipösen Patienten mit Herzinsuffizienz des HFpEF-Phänotyps ist Semaglutid von symptomatischem Nutzen. Resultiert dieser Benefit allein aus der Gewichtsreduktion oder auch aus spezifischen Effekten auf die Herzinsuffizienz-Pathogenese? Eine neue Analyse gibt Aufschluss.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.