Protective aprons in imaging departments: manufacturer stated lead equivalence values require validation

verfasst von: M. Finnerty, P. C. Brennan

Erschienen in: European Radiology | Ausgabe 7/2005

Einloggen, um Zugang zu erhalten

Abstract

The composition of protective aprons worn by X-ray personnel to shield against secondary radiation is changing. Lead is being replaced by either lead-free or composite (lead with other high atomic numbered elements) materials. These newer aprons are categorised by manufacturers in terms of lead equivalent values, but it is unclear how these stated values compare with actual lead equivalent values. In this work, the actual lead equivalence of 41 protective aprons from four manufacturers, all specified as having 0.25 mm lead equivalence, were investigated with transmission experiments at 70 and 100 kVp. All aprons were in current use. The aprons were screened for defects, and age, weight and design was recorded along with details of associated quality assurance (QA). Out of the 41 protective aprons examined for actual lead equivalence, 73% were outside tolerance levels, with actual levels in some aprons demonstrating less than half of the nominal values. The lack of compatibility between actual and nominal lead equivalent values was demonstrated by aprons from three of the four manufacturers investigated. The area of the defects found on screening of the protective aprons were within recommendations. The results highlight the need for acceptancy and ongoing checks of protective aprons to ensure that radiation exposure of imaging personnel is kept to a minimum.
Literatur
1.
Zurück zum Zitat Hubbert TE, Vucich JJ, Armstrong MR (1993) Lightweight aprons for protection against scattered radiation during fluoroscopy. Am J Roentgenol 161:1079–1081 Hubbert TE, Vucich JJ, Armstrong MR (1993) Lightweight aprons for protection against scattered radiation during fluoroscopy. Am J Roentgenol 161:1079–1081
2.
Zurück zum Zitat Institute of Physics and Engineering in Medicine (2002) Medical guidance notes. Paragraph 3.119 Institute of Physics and Engineering in Medicine (2002) Medical guidance notes. Paragraph 3.119
3.
Zurück zum Zitat Moore B, VanSonnenberg E, Casola G, Novelline RA (1992) The relationship between back pain and lead apron use in radiologists. Am J Roentgenol 158:191–193 Moore B, VanSonnenberg E, Casola G, Novelline RA (1992) The relationship between back pain and lead apron use in radiologists. Am J Roentgenol 158:191–193
4.
Zurück zum Zitat Webster EW (1966) Experiments with medium-Z materials for shielding against low energy X-rays. Radiology 86:146 Webster EW (1966) Experiments with medium-Z materials for shielding against low energy X-rays. Radiology 86:146
5.
Zurück zum Zitat Yaffe MJ, Mawdsley GE, Lilley M, Servant R, Reh G (1991) Composite materials for X-ray protection. Health Phys 60(5):661–664 Yaffe MJ, Mawdsley GE, Lilley M, Servant R, Reh G (1991) Composite materials for X-ray protection. Health Phys 60(5):661–664
6.
Zurück zum Zitat Graham DT (1996) Principles of radiological physics, 3rd edn. Churchill Livingstone, Singapore Graham DT (1996) Principles of radiological physics, 3rd edn. Churchill Livingstone, Singapore
7.
Zurück zum Zitat International Standard IEC 1331-1 (1994) Protective devices against diagnostic medical X-radiation. International Electrotechnical Commission, Geneva, Switzerland International Standard IEC 1331-1 (1994) Protective devices against diagnostic medical X-radiation. International Electrotechnical Commission, Geneva, Switzerland
8.
Zurück zum Zitat Murphy PH, Wu Y, Glaze S (1993) Attenuation properties of lead composite aprons. Radiology 186:269–272 Murphy PH, Wu Y, Glaze S (1993) Attenuation properties of lead composite aprons. Radiology 186:269–272
9.
Zurück zum Zitat Christodoulou EG, Goodsitt MM, Larson SC, Darner KL, Satti J, Chan HP (2003) Evaluation of the transmitted exposure through lead equivalent protective aprons used in a radiology department, including the contribution from backscatter. Med Phys 30(6):1033–1038 Christodoulou EG, Goodsitt MM, Larson SC, Darner KL, Satti J, Chan HP (2003) Evaluation of the transmitted exposure through lead equivalent protective aprons used in a radiology department, including the contribution from backscatter. Med Phys 30(6):1033–1038
10.
Zurück zum Zitat National Council on Radiation Protection and Measurements (2001) Structural shielding design for diagnostic medical X-ray facilities. Table A.1, 121 National Council on Radiation Protection and Measurements (2001) Structural shielding design for diagnostic medical X-ray facilities. Table A.1, 121
11.
Zurück zum Zitat Lambert K, McKeon T (2001) Inspection of lead aprons: criteria for rejection. Health Phys 80(5):S67–S69 Lambert K, McKeon T (2001) Inspection of lead aprons: criteria for rejection. Health Phys 80(5):S67–S69
12.
Zurück zum Zitat Michel R, Zorn MJ (2002) Implementation of an X-ray radiation protective equipment inspection program. Health Phys 82:S51–S53 Michel R, Zorn MJ (2002) Implementation of an X-ray radiation protective equipment inspection program. Health Phys 82:S51–S53
13.
Zurück zum Zitat Glaze S, LeBlanc AD, Bushong SC (1984) Defects in new protective aprons. Radiology 152:217–218 Glaze S, LeBlanc AD, Bushong SC (1984) Defects in new protective aprons. Radiology 152:217–218
14.
Zurück zum Zitat Johnston DA, Brennan PC (2000) Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals. Br J Radiol 73:396–402 Johnston DA, Brennan PC (2000) Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals. Br J Radiol 73:396–402
15.
Zurück zum Zitat Ng K-H, Rassiah P, Wang H-B et al. (1998) Doses to patients in routine X-ray examinations in Malaysia. Br J Radiol 71:654–660 Ng K-H, Rassiah P, Wang H-B et al. (1998) Doses to patients in routine X-ray examinations in Malaysia. Br J Radiol 71:654–660
16.
Zurück zum Zitat Neofotistou V, Vano E, Padovani R et al. (2003) Preliminary reference levels in interventional cardiology. Eur Radiol 13:2259–2263 Neofotistou V, Vano E, Padovani R et al. (2003) Preliminary reference levels in interventional cardiology. Eur Radiol 13:2259–2263
Metadaten
Titel
Protective aprons in imaging departments: manufacturer stated lead equivalence values require validation
verfasst von
M. Finnerty
P. C. Brennan
Publikationsdatum
01.07.2005
Erschienen in
European Radiology / Ausgabe 7/2005
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2571-2

Weitere Artikel der Ausgabe 7/2005

European Radiology 7/2005 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.