Targeted post-mortem computed tomography angiography (PMCTA) is one of several methods described that can be used to investigate the coronary arteries after death. Previously, this particular method has involved the manual injection of contrast media. However, manual systems do not mimic physiological conditions (arterial pressure) and may not provide optimal contrast, as iodinated contrast medium dissipates rapidly from the intra- to the extra-vascular space. To try and overcome these problems, we now report the use of a clinical automatic pump injector for targeted PMCTA. We present our final protocol for this pump system developed from experience of 74 cases, showing how these clinical pumps can be translated from clinical into autopsy practice for the injection of air and positive contrast media to visualise the coronary arteries of cadavers.
Literatur
1.
Zurück zum Zitat Dirnhofer R, Jackowski C, Vock P, Potter K, Thali MJ (2006) VIRTOPSY: minimally invasive, imaging-guided virtual autopsy. Radiographics 26:1305–1333PubMedCrossRef Dirnhofer R, Jackowski C, Vock P, Potter K, Thali MJ (2006) VIRTOPSY: minimally invasive, imaging-guided virtual autopsy. Radiographics 26:1305–1333PubMedCrossRef
2.
Zurück zum Zitat Thali M, Dirnhofer R, Vock P (eds) (2009) The virtopsy approach: 3D optical and radio- logical scanning and reconstruction in forensic medicine. CRC, New York Thali M, Dirnhofer R, Vock P (eds) (2009) The virtopsy approach: 3D optical and radio- logical scanning and reconstruction in forensic medicine. CRC, New York
3.
Zurück zum Zitat Weustink AC, Hunink MGM, van Dijke CF, Renken NS, Krestin GP, Oosterhuis JW (2009) Minimally invasive autopsy: an alternative to conventional autopsy? Radiology 250:897–904PubMedCrossRef Weustink AC, Hunink MGM, van Dijke CF, Renken NS, Krestin GP, Oosterhuis JW (2009) Minimally invasive autopsy: an alternative to conventional autopsy? Radiology 250:897–904PubMedCrossRef
4.
Zurück zum Zitat Jeffery AJ (2010) The role of computed tomography in adult postmortem examinations: an overview. Diagn Histopathol 16:546–551CrossRef Jeffery AJ (2010) The role of computed tomography in adult postmortem examinations: an overview. Diagn Histopathol 16:546–551CrossRef
5.
Zurück zum Zitat O'Donnell C (2010) An image of sudden death: utility of routine postmortem computed tomography scanning in medico-legal autopsy practice. Diagn Histopathol 16:552–555CrossRef O'Donnell C (2010) An image of sudden death: utility of routine postmortem computed tomography scanning in medico-legal autopsy practice. Diagn Histopathol 16:552–555CrossRef
6.
Zurück zum Zitat Jacobsen C, Lynnerup N (2010) Craniocerebral trauma—congruence between postmortem computed tomography diagnoses and autopsy results: a 2-year retrospective study. Forensic Sci Int 194:9–14PubMedCrossRef Jacobsen C, Lynnerup N (2010) Craniocerebral trauma—congruence between postmortem computed tomography diagnoses and autopsy results: a 2-year retrospective study. Forensic Sci Int 194:9–14PubMedCrossRef
7.
Zurück zum Zitat Roberts ISD, Benamore RE, Benbow EW, Lee SH, Harris JN, Jackson A, Mallett S, Patankar T, Peebles C, Roobottom C, Traill ZC (2012) Postmortem imaging as an alternative to autopsy in the diagnosis of adult deaths: a validation study. Lancet 379:136–142PubMedCrossRef Roberts ISD, Benamore RE, Benbow EW, Lee SH, Harris JN, Jackson A, Mallett S, Patankar T, Peebles C, Roobottom C, Traill ZC (2012) Postmortem imaging as an alternative to autopsy in the diagnosis of adult deaths: a validation study. Lancet 379:136–142PubMedCrossRef
8.
Zurück zum Zitat Sakamoto N, Senoo S, Uemura Y et al (2009) Case report: cardiopulmonary arrest on arrival case which underwent contrast-enhanced post-mortem CT. KANTO. J Japanese Association Acute Med 30:114–115 Sakamoto N, Senoo S, Uemura Y et al (2009) Case report: cardiopulmonary arrest on arrival case which underwent contrast-enhanced post-mortem CT. KANTO. J Japanese Association Acute Med 30:114–115
9.
Zurück zum Zitat Lizuka K, Sakamoto N, Kawasaki H, Miyoshi T, Komatuzaki A, Kikuchi S (2009) Usefulness of contrast-enhanced post-mortem CT. Innervision 24:89–92 Lizuka K, Sakamoto N, Kawasaki H, Miyoshi T, Komatuzaki A, Kikuchi S (2009) Usefulness of contrast-enhanced post-mortem CT. Innervision 24:89–92
10.
Zurück zum Zitat Grabherr S, Gygax E, Sollberger B, Ross S, Oesterhelweg L, Bolliger S et al (2008) Two-step postmortem angiography with a modified heart–lung machine: preliminary results. Am J Roentgenol 190:345–351CrossRef Grabherr S, Gygax E, Sollberger B, Ross S, Oesterhelweg L, Bolliger S et al (2008) Two-step postmortem angiography with a modified heart–lung machine: preliminary results. Am J Roentgenol 190:345–351CrossRef
11.
Zurück zum Zitat Ross S, Spendlove D, Bolliger S, Christe A, Oesterhelweg L, Grabherr S et al (2008) Postmortem whole-body CT angiography: evaluation of two contrast media solutions. AJR Am J Roentgenol 190:1380–1389PubMedCrossRef Ross S, Spendlove D, Bolliger S, Christe A, Oesterhelweg L, Grabherr S et al (2008) Postmortem whole-body CT angiography: evaluation of two contrast media solutions. AJR Am J Roentgenol 190:1380–1389PubMedCrossRef
12.
Zurück zum Zitat Grabherr S, Djonov V, Yen K, Thali MJ, Dirnhofer R (2007) Postmortem angiography: review of former and current methods. Am J Roentgenol 188:832–838CrossRef Grabherr S, Djonov V, Yen K, Thali MJ, Dirnhofer R (2007) Postmortem angiography: review of former and current methods. Am J Roentgenol 188:832–838CrossRef
13.
Zurück zum Zitat Jackowski C, Persson A, Thali MJ (2008) Whole body postmortem angiography with a high viscosity contrast agent solution using poly ethylene glycol as contrast agent dissolver. J Forensic Sci 53:465–468PubMedCrossRef Jackowski C, Persson A, Thali MJ (2008) Whole body postmortem angiography with a high viscosity contrast agent solution using poly ethylene glycol as contrast agent dissolver. J Forensic Sci 53:465–468PubMedCrossRef
14.
Zurück zum Zitat Jackowski C, Sonnenschein M, Thali MJ, Aghayev E, von Allmen G, Yen K et al (2008) Virtopsy: postmortem minimally invasive angiography using cross section techniques—implementation and preliminary results. J Forensic Sci 50:1175–1186 Jackowski C, Sonnenschein M, Thali MJ, Aghayev E, von Allmen G, Yen K et al (2008) Virtopsy: postmortem minimally invasive angiography using cross section techniques—implementation and preliminary results. J Forensic Sci 50:1175–1186
15.
Zurück zum Zitat Grabherr S, Doenz F, Steger B, Dirnhofer R, Dominguez A, Sollberger B et al (2010) Multi-phase post-mortem CT angiography: development of a standardized protocol. Int J Legal Med 125:791–802PubMedCrossRef Grabherr S, Doenz F, Steger B, Dirnhofer R, Dominguez A, Sollberger B et al (2010) Multi-phase post-mortem CT angiography: development of a standardized protocol. Int J Legal Med 125:791–802PubMedCrossRef
16.
Zurück zum Zitat Michaud K, Grabherr S, Doenz F, Mangin P (2012) Evaluation of postmortem MDCT and MDCT-angiography for the investigation of sudden cardiac death related to atherosclerotic coronary artery disease. Int J Cardiovasc Imaging 28(7):1807–1822PubMedCrossRef Michaud K, Grabherr S, Doenz F, Mangin P (2012) Evaluation of postmortem MDCT and MDCT-angiography for the investigation of sudden cardiac death related to atherosclerotic coronary artery disease. Int J Cardiovasc Imaging 28(7):1807–1822PubMedCrossRef
17.
Zurück zum Zitat Saunders SL, Morgan B, Raj V, Robinson C, Rutty GN (2011) Targeted post-mortem computed tomography cardiac angiography: proof of concept. Int J Legal Med 125:609–616PubMedCrossRef Saunders SL, Morgan B, Raj V, Robinson C, Rutty GN (2011) Targeted post-mortem computed tomography cardiac angiography: proof of concept. Int J Legal Med 125:609–616PubMedCrossRef
18.
Zurück zum Zitat Rutty GN, Saunders S, Morgan B, Raj V (2012) Targeted cardiac post-mortem computed tomography angiography: a pictorial review. Forensic Sci Med Pathol 8:40–47PubMedCrossRef Rutty GN, Saunders S, Morgan B, Raj V (2012) Targeted cardiac post-mortem computed tomography angiography: a pictorial review. Forensic Sci Med Pathol 8:40–47PubMedCrossRef
19.
Zurück zum Zitat Roberts ISD, Benamore RE, Peebles C, Roobottom C, Traill ZC (2011) Diagnosis of coronary artery disease using a minimally invasive autopsy: evaluation of a novel method of post-mortem coronary CT angiography. Clin Radiol 66:645–650PubMedCrossRef Roberts ISD, Benamore RE, Peebles C, Roobottom C, Traill ZC (2011) Diagnosis of coronary artery disease using a minimally invasive autopsy: evaluation of a novel method of post-mortem coronary CT angiography. Clin Radiol 66:645–650PubMedCrossRef
20.
Zurück zum Zitat Coghill SB, Nicoll SM, McKimmie A, Houston I, Matthew BM (1983) Revitalising postmortem coronary angiography. J Clin Pathol 36:1406–1409PubMedCrossRef Coghill SB, Nicoll SM, McKimmie A, Houston I, Matthew BM (1983) Revitalising postmortem coronary angiography. J Clin Pathol 36:1406–1409PubMedCrossRef
Metadaten
Titel
Pump injector system applied to targeted post-mortem coronary artery angiography
verfasst von
Claire Robinson
Jade Barber
Jasmin Amoroso
Bruno Morgan
Guy Rutty
Publikationsdatum
01.05.2013
Verlag
Springer-Verlag
Erschienen in
International Journal of Legal Medicine / Ausgabe 3/2013
Print ISSN: 0937-9827
Elektronische ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-012-0802-7

Weitere Artikel der Ausgabe 3/2013

International Journal of Legal Medicine 3/2013 Zur Ausgabe

Neu im Fachgebiet Rechtsmedizin

Molekularpathologische Untersuchungen im Wandel der Zeit

Open Access Biomarker Leitthema

Um auch an kleinen Gewebeproben zuverlässige und reproduzierbare Ergebnisse zu gewährleisten ist eine strenge Qualitätskontrolle in jedem Schritt des Arbeitsablaufs erforderlich. Eine nicht ordnungsgemäße Prüfung oder Behandlung des …

Vergleichende Pathologie in der onkologischen Forschung

Pathologie Leitthema

Die vergleichende experimentelle Pathologie („comparative experimental pathology“) ist ein Fachbereich an der Schnittstelle von Human- und Veterinärmedizin. Sie widmet sich der vergleichenden Erforschung von Gemeinsamkeiten und Unterschieden von …

Gastrointestinale Stromatumoren

Open Access GIST CME-Artikel

Gastrointestinale Stromatumoren (GIST) stellen seit über 20 Jahren ein Paradigma für die zielgerichtete Therapie mit Tyrosinkinaseinhibitoren dar. Eine elementare Voraussetzung für eine mögliche neoadjuvante oder adjuvante Behandlung bei …

Personalisierte Medizin in der Onkologie

Aufgrund des erheblichen technologischen Fortschritts in der molekularen und genetischen Diagnostik sowie zunehmender Erkenntnisse über die molekulare Pathogenese von Krankheiten hat in den letzten zwei Jahrzehnten ein grundlegender …