Skip to main content
Erschienen in: Journal of Digital Imaging 4/2020

08.04.2020 | Original Paper

Rapid Design and Development of a Network Isolated DICOM Service Class Provider Device

verfasst von: S. E. Ziegler

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 4/2020

Einloggen, um Zugang zu erhalten

Abstract

Integrating vendor equipment and instruments into a corporate pharmaceutical research environment can be challenging and in light of recently reported cyber-attacks across industries and ongoing threats, additional security measures add to the challenge. In theory, Windows 10-based equipment coupled with the Digital Imaging and Communications in Medicine (DICOM) protocol should make it easier for instrument integration. A challenge arose with the onboarding of 2 new Microsoft Windows 10, DICOM compliant, Pre-clinical Positron Emission Tomography and Computed Tomography (PET/CT) instruments post acquisition when we discovered that we were restricted from connecting them to our corporate network. These new instruments were scheduled to run studies the following week. The coordinating of PET studies is complex, so schedule disruption incurs costs and long-term scheduling impacts. The solution was to develop a DICOM Service Class Provider (SCP) device using a commodity beagleboard.​org BeagleBone Black (BBB) Rev. C device, the Offis DCMTK open source toolkit, and automation code written in Python. The BBB device provides network and DICOM communication from the instrument to the BBB, it provides the corporate network connectivity needed to NFS mount the network attached storage (NAS) system, isolated the two networks, and moves the files to the appropriate NAS share. The design went from concept to production ready in less than 24 h, providing a cost-effective, reliable, robust, and easily supported solution. The device satisfies internal and best practice security concerns, and it isolates the instrument from the network adding a layer of cyber resilience protection for the instrument.
Literatur
2.
Zurück zum Zitat Hargreaves RJ: The role of molecular imaging in drug discovery and development. Clin Pharmacol Ther 82(2): 349–353,2008CrossRef Hargreaves RJ: The role of molecular imaging in drug discovery and development. Clin Pharmacol Ther 82(2): 349–353,2008CrossRef
4.
Zurück zum Zitat Dean Bidgood W, Steven C. Horii, Fred W. Prior, Donald E. Van Syckle: Understanding and Using DICOM, the Data Interchange Standard for Biomedical Imaging. J Am Med Inform Assoc 4:3, 199–212,1997CrossRef Dean Bidgood W, Steven C. Horii, Fred W. Prior, Donald E. Van Syckle: Understanding and Using DICOM, the Data Interchange Standard for Biomedical Imaging. J Am Med Inform Assoc 4:3, 199–212,1997CrossRef
6.
Zurück zum Zitat Ziegler SE: Development of a next-generation automated DICOM processing system in a PACS-less research environment. J Digit Imaging 25(5): 670–677, 2012 Ziegler SE: Development of a next-generation automated DICOM processing system in a PACS-less research environment. J Digit Imaging 25(5): 670–677, 2012
8.
Zurück zum Zitat Bogatinov, Dimitar, Angelevski, Slavko: USB flash drives - security risks and protection. International Scientific Conference -The Balkans between past and future: Security, conflict resolution and Euro-Atlantic integration, I. pp 622–633, 2013 Bogatinov, Dimitar, Angelevski, Slavko: USB flash drives - security risks and protection. International Scientific Conference -The Balkans between past and future: Security, conflict resolution and Euro-Atlantic integration, I. pp 622–633, 2013
9.
Zurück zum Zitat Nayyar A, Puri V: “A Review of Beaglebone Smart Board’s-A Linux/Android Powered Low Cost Development Platform Based on ARM Technology,” 2015 9th International conference on future generation communication and networking (FGCN), Jeju, pp 55–63, 2015 Nayyar A, Puri V: “A Review of Beaglebone Smart Board’s-A Linux/Android Powered Low Cost Development Platform Based on ARM Technology,” 2015 9th International conference on future generation communication and networking (FGCN), Jeju, pp 55–63, 2015
Metadaten
Titel
Rapid Design and Development of a Network Isolated DICOM Service Class Provider Device
verfasst von
S. E. Ziegler
Publikationsdatum
08.04.2020
Verlag
Springer International Publishing
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 4/2020
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-020-00335-z

Weitere Artikel der Ausgabe 4/2020

Journal of Digital Imaging 4/2020 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.