Despite the increase in clinical use of navigation systems in total knee arthroplasty, few studies have focused on the reproducibility of these systems. The aim of the present study was to assess the influence of knee position and observer experience on intra- and inter-observer agreement in limb alignment assessment with the OrthoPilot system. Limb alignment in the coronal plane and extension range of the knee were assessed in four embalmed cadaveric specimens by five independent observers and measurements were repeated four times to determine intra- and inter-observer agreement, expressed as intraclass correlation coefficients (ICCs). Additionally, navigation results were compared against figures from conventional measurement of leg alignment (ground truth). Intra- and inter-observer agreements were excellent for assessing the extension range (ICC, 0.97 and 0.95) and the coronal femuro-tibial axis in knee extension (ICC, 0.92 and 0.88) but were generally worse in knee flexion (ICC, 0.62 and 0.55). There was an increased tendency of intraobserver errors in observers with less clinical experience. Mean correlation with conventional measurements was fair (Spearman’s rho 0.61). The OrthoPilot system showed excellent reproducibility for assessment of extension range and coronal limb alignment. However, assessments of coronal limb alignment in flexion were prone to error and caution should be taken when relying on these measurements.
Literatur
1.
Zurück zum Zitat Abbot LC, Walter F, Carpenter WF (1945) Surgical approaches to the knee joint. J Bone Jt Surg Am 27:277–310 Abbot LC, Walter F, Carpenter WF (1945) Surgical approaches to the knee joint. J Bone Jt Surg Am 27:277–310
2.
Zurück zum Zitat Bargren JH, Blaha JD, Freeman MA (1983) Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop Relat Res 173:178–183PubMed Bargren JH, Blaha JD, Freeman MA (1983) Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop Relat Res 173:178–183PubMed
3.
Zurück zum Zitat Bathis H, Perlick L, Luring C, Kalteis T, Grifka J (2003) CT-based and CT-free navigation in knee prosthesis implantation. Results of a prospective study. Unfallchirurg 106:935–940PubMed Bathis H, Perlick L, Luring C, Kalteis T, Grifka J (2003) CT-based and CT-free navigation in knee prosthesis implantation. Results of a prospective study. Unfallchirurg 106:935–940PubMed
4.
Zurück zum Zitat Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Jt Surg Br 86:682–687. doi:10.1302/0301-620X.86B5.14927 CrossRef Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Jt Surg Br 86:682–687. doi:10.​1302/​0301-620X.​86B5.​14927 CrossRef
5.
Zurück zum Zitat Bathis H, Shafizadeh S, Paffrath T, Simanski C, Grifka J, Luring C (2006) Are computer assisted total knee replacements more accurately placed? A meta-analysis of comparative studies. Orthopade 35:1056–1065. doi:10.1007/s00132-006-1001-3 PubMedCrossRef Bathis H, Shafizadeh S, Paffrath T, Simanski C, Grifka J, Luring C (2006) Are computer assisted total knee replacements more accurately placed? A meta-analysis of comparative studies. Orthopade 35:1056–1065. doi:10.​1007/​s00132-006-1001-3 PubMedCrossRef
6.
9.
Zurück zum Zitat Caillouette JT, Anzel SH (1990) Fat embolism syndrome following the intramedullary alignment guide in total knee arthroplasty. Clin Orthop Relat Res 251:198–199PubMed Caillouette JT, Anzel SH (1990) Fat embolism syndrome following the intramedullary alignment guide in total knee arthroplasty. Clin Orthop Relat Res 251:198–199PubMed
10.
Zurück zum Zitat Fleiss JL (1986) The design and analysis of clinical experiments. Wiley, New York Fleiss JL (1986) The design and analysis of clinical experiments. Wiley, New York
12.
Zurück zum Zitat Hinman RS, May RL, Crossley KM (2006) Is there an alternative to the full-leg radiograph for determining knee joint alignment in osteoarthritis? Arthritis Rheum 55:306–313. doi:10.1002/art.21836 PubMedCrossRef Hinman RS, May RL, Crossley KM (2006) Is there an alternative to the full-leg radiograph for determining knee joint alignment in osteoarthritis? Arthritis Rheum 55:306–313. doi:10.​1002/​art.​21836 PubMedCrossRef
13.
Zurück zum Zitat Ishii Y, Ohmori G, Bechtold JE, Gustilo RB (1995) Extramedullary versus intramedullary alignment guides in total knee arthroplasty. Clin Orthop Relat Res 318:167–175PubMed Ishii Y, Ohmori G, Bechtold JE, Gustilo RB (1995) Extramedullary versus intramedullary alignment guides in total knee arthroplasty. Clin Orthop Relat Res 318:167–175PubMed
14.
Zurück zum Zitat Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Jt Surg Br 73:709–714 Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Jt Surg Br 73:709–714
16.
Zurück zum Zitat Jenny JY, Boeri C, Picard F, Leitner F (2004) Reproducibility of intra-operative measurement of the mechanical axes of the lower limb during total knee replacement with a non-image-based navigation system. Comput Aided Surg 9:161–165. doi:10.1080/10929080500095517 PubMedCrossRef Jenny JY, Boeri C, Picard F, Leitner F (2004) Reproducibility of intra-operative measurement of the mechanical axes of the lower limb during total knee replacement with a non-image-based navigation system. Comput Aided Surg 9:161–165. doi:10.​1080/​1092908050009551​7 PubMedCrossRef
17.
Zurück zum Zitat Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case–control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20:832–839. doi:10.1016/j.arth.2005.02.002 PubMedCrossRef Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case–control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20:832–839. doi:10.​1016/​j.​arth.​2005.​02.​002 PubMedCrossRef
18.
Zurück zum Zitat Kendoff D, Board TN, Citak M, Gardner MJ, Hankemeier S, Ostermeier S, Krettek C, Hufner T (2008) Navigated lower limb axis measurements: influence of mechanical weight-bearing simulation. J Orthop Res 26:553–561. doi:10.1002/jor.20510 PubMedCrossRef Kendoff D, Board TN, Citak M, Gardner MJ, Hankemeier S, Ostermeier S, Krettek C, Hufner T (2008) Navigated lower limb axis measurements: influence of mechanical weight-bearing simulation. J Orthop Res 26:553–561. doi:10.​1002/​jor.​20510 PubMedCrossRef
19.
Zurück zum Zitat Kendoff D, Citak M, Pearle A, Gardner MJ, Hankemeier S, Krettek C, Hufner T (2007) Influence of lower limb rotation in navigated alignment analysis: implications for high tibial osteotomies. Knee Surg Sports Traumatol Arthrosc 15:1003–1008. doi:10.1007/s00167-007-0308-x PubMedCrossRef Kendoff D, Citak M, Pearle A, Gardner MJ, Hankemeier S, Krettek C, Hufner T (2007) Influence of lower limb rotation in navigated alignment analysis: implications for high tibial osteotomies. Knee Surg Sports Traumatol Arthrosc 15:1003–1008. doi:10.​1007/​s00167-007-0308-x PubMedCrossRef
22.
Zurück zum Zitat Oberst M, Bertsch C, Lahm A, Wuerstlin S, Holz U (2006) Regression and correlation analysis of preoperative versus intraoperative assessment of axes during navigated total knee arthroplasty. Comput Aided Surg 11:87–91. doi:10.1080/10929080600632680 PubMedCrossRef Oberst M, Bertsch C, Lahm A, Wuerstlin S, Holz U (2006) Regression and correlation analysis of preoperative versus intraoperative assessment of axes during navigated total knee arthroplasty. Comput Aided Surg 11:87–91. doi:10.​1080/​1092908060063268​0 PubMedCrossRef
24.
Zurück zum Zitat Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed
25.
Zurück zum Zitat Rosenberger RE, Fink C, Quirbach S, Attal R, Tecklenburg K, Hoser C (2008) The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:1133–1140. doi:10.1007/s00167-008-0618-7 PubMedCrossRef Rosenberger RE, Fink C, Quirbach S, Attal R, Tecklenburg K, Hoser C (2008) The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:1133–1140. doi:10.​1007/​s00167-008-0618-7 PubMedCrossRef
26.
Zurück zum Zitat Rosenberger RE, Hoser C, Quirbach S, Attal R, Hennerbichler A, Fink C (2008) Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:249–257. doi:10.1007/s00167-007-0420-y PubMedCrossRef Rosenberger RE, Hoser C, Quirbach S, Attal R, Hennerbichler A, Fink C (2008) Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:249–257. doi:10.​1007/​s00167-007-0420-y PubMedCrossRef
28.
Zurück zum Zitat Specogna AV, Birmingham TB, Hunt MA, Jones IC, Jenkyn TR, Fowler PJ, Giffin JR (2007) Radiographic measures of knee alignment in patients with varus gonarthrosis: effect of weight bearing status and associations with dynamic joint load. Am J Sports Med 35:65–70. doi:10.1177/0363546506293024 PubMedCrossRef Specogna AV, Birmingham TB, Hunt MA, Jones IC, Jenkyn TR, Fowler PJ, Giffin JR (2007) Radiographic measures of knee alignment in patients with varus gonarthrosis: effect of weight bearing status and associations with dynamic joint load. Am J Sports Med 35:65–70. doi:10.​1177/​0363546506293024​ PubMedCrossRef
30.
Zurück zum Zitat Yau WP, Leung A, Chiu KY, Tang WM, Ng TP (2005) Intraobserver errors in obtaining visually selected anatomic landmarks during registration process in nonimage-based navigation-assisted total knee arthroplasty: a cadaveric experiment. J Arthroplasty 20:591–601. doi:10.1016/j.arth.2005.02.011 PubMedCrossRef Yau WP, Leung A, Chiu KY, Tang WM, Ng TP (2005) Intraobserver errors in obtaining visually selected anatomic landmarks during registration process in nonimage-based navigation-assisted total knee arthroplasty: a cadaveric experiment. J Arthroplasty 20:591–601. doi:10.​1016/​j.​arth.​2005.​02.​011 PubMedCrossRef
31.
Zurück zum Zitat Yau WP, Leung A, Liu KG, Yan CH, Wong LL, Chiu KY (2007) Interobserver and intra-observer errors in obtaining visually selected anatomical landmarks during registration process in non-image-based navigation-assisted total knee arthroplasty. J Arthroplasty 22:1150–1161. doi:10.1016/j.arth.2006.10.010 PubMedCrossRef Yau WP, Leung A, Liu KG, Yan CH, Wong LL, Chiu KY (2007) Interobserver and intra-observer errors in obtaining visually selected anatomical landmarks during registration process in non-image-based navigation-assisted total knee arthroplasty. J Arthroplasty 22:1150–1161. doi:10.​1016/​j.​arth.​2006.​10.​010 PubMedCrossRef
32.
Zurück zum Zitat Yau WP, Leung A, Liu KG, Yan CH, Wong LS, Chiu KY (2008) Errors in the identification of the transepicondylar and anteroposterior axes of the distal femur in total knee replacement using minimally-invasive and conventional approaches: a cadaver study. J Bone Jt Surg Br 90:520–526. doi:10.1302/0301-620X.90B4.19841 CrossRef Yau WP, Leung A, Liu KG, Yan CH, Wong LS, Chiu KY (2008) Errors in the identification of the transepicondylar and anteroposterior axes of the distal femur in total knee replacement using minimally-invasive and conventional approaches: a cadaver study. J Bone Jt Surg Br 90:520–526. doi:10.​1302/​0301-620X.​90B4.​19841 CrossRef
Metadaten
Titel
Reliability of leg alignment using the OrthoPilot system depends on knee position: a cadaveric study
verfasst von
Oliver Hauschild
L. Konstantinidis
P. C. Strohm
P. Niemeyer
N. P. Suedkamp
P. Helwig
Publikationsdatum
01.10.2009
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 10/2009
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-009-0825-x

Weitere Artikel der Ausgabe 10/2009

Knee Surgery, Sports Traumatology, Arthroscopy 10/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.