Abstract

Purpose

To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T.

Methods

A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications.

Results

105 MRI-guided epidural injections (12 of 105 with gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 ± 9 min in the gadolinium-enhanced saline solution group and 22 ± 8 min in the saline solution group (p = 0.75).

Conclusion

Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.
Literatur
1.
Zurück zum Zitat Riew KD, Yin Y, Gilula L et al (2000) The effect of nerve-root injections on the need for operative treatment of lumbar radicular pain. A prospective, randomized, controlled, double-blind study. J Bone Joint Surg Am 82:1589–1593PubMed Riew KD, Yin Y, Gilula L et al (2000) The effect of nerve-root injections on the need for operative treatment of lumbar radicular pain. A prospective, randomized, controlled, double-blind study. J Bone Joint Surg Am 82:1589–1593PubMed
2.
Zurück zum Zitat Groenemeyer DHW, Seibel RMM (1990) Interventional computed tomography. Blackwell, Oxford Groenemeyer DHW, Seibel RMM (1990) Interventional computed tomography. Blackwell, Oxford
3.
Zurück zum Zitat Richards RJ, George J, Metelko M et al (2010) Spine computed tomography doses and cancer induction. Spine 35:1–4CrossRef Richards RJ, George J, Metelko M et al (2010) Spine computed tomography doses and cancer induction. Spine 35:1–4CrossRef
4.
Zurück zum Zitat Groenemeyer D, Seibel RM, Kaufmann L (1990) Interventional procedures in low field magnetic resonance imaging. Diagn Imaging 11:32–36 Groenemeyer D, Seibel RM, Kaufmann L (1990) Interventional procedures in low field magnetic resonance imaging. Diagn Imaging 11:32–36
5.
Zurück zum Zitat Lufkin R, Teresi L, Hanafee W (1987) New needle for MR-guided aspiration cytology of the head and neck. AJR Am J Roentgenol 149:380–382PubMedCrossRef Lufkin R, Teresi L, Hanafee W (1987) New needle for MR-guided aspiration cytology of the head and neck. AJR Am J Roentgenol 149:380–382PubMedCrossRef
6.
Zurück zum Zitat Mueller PR, Stark DD, Simeone JF et al (1986) MR-guided aspiration biopsy: needle design and clinical trials. Radiology 161:605–609PubMed Mueller PR, Stark DD, Simeone JF et al (1986) MR-guided aspiration biopsy: needle design and clinical trials. Radiology 161:605–609PubMed
7.
Zurück zum Zitat Busch M, Bornstedt A, Wendt M et al (1998) Fast “real time” imaging with different k-space update strategies for interventional procedures. J Magn Reson Imaging 8:944–954PubMedCrossRef Busch M, Bornstedt A, Wendt M et al (1998) Fast “real time” imaging with different k-space update strategies for interventional procedures. J Magn Reson Imaging 8:944–954PubMedCrossRef
8.
Zurück zum Zitat Yutzy SR, Duerk JL (2008) Pulse sequences and system interfaces for interventional and real-time MRI. J Magn Reson Imaging 27:267–275PubMedCrossRef Yutzy SR, Duerk JL (2008) Pulse sequences and system interfaces for interventional and real-time MRI. J Magn Reson Imaging 27:267–275PubMedCrossRef
9.
Zurück zum Zitat Smith KA, Carrino J (2008) MRI-guided interventions of the musculoskeletal system. J Magn Reson Imaging 27:339–346PubMedCrossRef Smith KA, Carrino J (2008) MRI-guided interventions of the musculoskeletal system. J Magn Reson Imaging 27:339–346PubMedCrossRef
10.
Zurück zum Zitat Lewin JS, Duerk JL, Jain VR et al (1996) Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. AJR Am J Roentgenol 166:1337–1345PubMedCrossRef Lewin JS, Duerk JL, Jain VR et al (1996) Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. AJR Am J Roentgenol 166:1337–1345PubMedCrossRef
11.
Zurück zum Zitat Jerosch J, Groenemeyer D, Deli M et al (2000) Precision and comparison of CT-, MRI- and DL-controlled interventions exemplified by lumbar facet infiltration—an experimental study. Biomed Tech 45:228–237CrossRef Jerosch J, Groenemeyer D, Deli M et al (2000) Precision and comparison of CT-, MRI- and DL-controlled interventions exemplified by lumbar facet infiltration—an experimental study. Biomed Tech 45:228–237CrossRef
12.
Zurück zum Zitat Fritz J, Thomas C, Clasen S et al (2009) Freehand real-time MRI-guided lumbar spinal injection procedures at 1.5 T: feasibility, accuracy, and safety. AJR Am J Roentgenol 192:W161–W167PubMedCrossRef Fritz J, Thomas C, Clasen S et al (2009) Freehand real-time MRI-guided lumbar spinal injection procedures at 1.5 T: feasibility, accuracy, and safety. AJR Am J Roentgenol 192:W161–W167PubMedCrossRef
13.
Zurück zum Zitat Fritz J, Tzaribachev N, Thomas C et al (2011) Evaluation of MR imaging guided steroid injection of the sacroiliac joints for the treatment of children with refractory enthesitis-related arthritis. Eur Radiol 21:1050–1057PubMedCrossRef Fritz J, Tzaribachev N, Thomas C et al (2011) Evaluation of MR imaging guided steroid injection of the sacroiliac joints for the treatment of children with refractory enthesitis-related arthritis. Eur Radiol 21:1050–1057PubMedCrossRef
14.
Zurück zum Zitat Fritz J, Clasen S, Boss A et al (2008) Real-time MR fluoroscopy-navigated lumbar facet joint injections: feasibility and technical properties. Eur Radiol 18:1513–1518PubMedCrossRef Fritz J, Clasen S, Boss A et al (2008) Real-time MR fluoroscopy-navigated lumbar facet joint injections: feasibility and technical properties. Eur Radiol 18:1513–1518PubMedCrossRef
15.
Zurück zum Zitat Fritz J, Thomas C, Tzaribachev N et al (2009) MRI-guided injection procedures of the temporomandibular joints in children and adults: technique, accuracy, and safety. AJR Am J Roentgenol 193:1148–1154PubMedCrossRef Fritz J, Thomas C, Tzaribachev N et al (2009) MRI-guided injection procedures of the temporomandibular joints in children and adults: technique, accuracy, and safety. AJR Am J Roentgenol 193:1148–1154PubMedCrossRef
16.
Zurück zum Zitat Salonen OL (1990) Case of anaphylaxis and four cases of allergic reaction following Gd-DTPA administration. J Comput Assist Tomogr 14:912–913PubMedCrossRef Salonen OL (1990) Case of anaphylaxis and four cases of allergic reaction following Gd-DTPA administration. J Comput Assist Tomogr 14:912–913PubMedCrossRef
17.
Zurück zum Zitat Graves MJ, Wakely S, Bearcroft PW et al (2008) MR-guided direct arthrography of the hip. J Magn Reson Imaging 28:462–465PubMedCrossRef Graves MJ, Wakely S, Bearcroft PW et al (2008) MR-guided direct arthrography of the hip. J Magn Reson Imaging 28:462–465PubMedCrossRef
18.
Zurück zum Zitat Petersilge CA, Lewin JS, Duerk JL et al (1997) MR arthrography of the shoulder: rethinking traditional imaging procedures to meet the technical requirements of MR imaging guidance. AJR Am J Roentgenol 169:1453–1457PubMedCrossRef Petersilge CA, Lewin JS, Duerk JL et al (1997) MR arthrography of the shoulder: rethinking traditional imaging procedures to meet the technical requirements of MR imaging guidance. AJR Am J Roentgenol 169:1453–1457PubMedCrossRef
19.
Zurück zum Zitat Streitparth F, Walter T, Wonneberger U et al (2010) Image-guided spinal injection procedures in open high-field MRI with vertical field orientation: feasibility and technical features. Eur Radiol 20:395–403PubMedCrossRef Streitparth F, Walter T, Wonneberger U et al (2010) Image-guided spinal injection procedures in open high-field MRI with vertical field orientation: feasibility and technical features. Eur Radiol 20:395–403PubMedCrossRef
20.
Zurück zum Zitat Fritz J, Henes JC, Thomas C et al (2008) Diagnostic and interventional MRI of the sacroiliac joints using a 1.5-T open-bore magnet: a one-stop-shopping approach. AJR Am J Roentgenol 191:1717–1724PubMedCrossRef Fritz J, Henes JC, Thomas C et al (2008) Diagnostic and interventional MRI of the sacroiliac joints using a 1.5-T open-bore magnet: a one-stop-shopping approach. AJR Am J Roentgenol 191:1717–1724PubMedCrossRef
Metadaten
Titel
Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections
verfasst von
Martin Deli
Jan Fritz
Serban Mateiescu
Martin Busch
John A. Carrino
Jan Becker
Marietta Garmer
Dietrich Grönemeyer
Publikationsdatum
01.06.2013
Verlag
Springer-Verlag
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 3/2013
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-012-0489-7

Weitere Artikel der Ausgabe 3/2013

CardioVascular and Interventional Radiology 3/2013 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.