Study aim To explore various sources of variability in the measurement of LV volumes and dyssynchrony by 3D echocardiography (3DE). Methods We studied 100 patients (58 ± 18 years, 51 men) to assess the impact of: (1) manual editing; (2) 3D data set temporal resolution; (3) LV 16- or 17-segmentation model; (4) software sensitivity for automated endocardial surface detection; and (5) image quality, on the measurement of LV end-diastolic (EDV) and end-systolic (ESV) volumes, sphericity indices (EDSI, ESSI), ejection fraction (EF) and dyssynchrony (SDI). Two- and 4-beat LV full-volume data sets were analyzed and compared. Cardiac magnetic resonance (CMR) was used as reference in 26 patients. Results Manual editing of endocardial surface improved the agreement of LV volumes with CMR, but increased SDI (SDI17: 5.6 ± 0.5% vs. 4.3 ± 0.3%; P < 0.0001). Data set temporal resolution had no significant impact on LV parameters. Adding the 17th to 16-segment LV model did not significantly increase SDI. Reducing software sensitivity in endocardial surface detection increased EDV (101 ± 46 ml vs. 118 ± 50 ml) and sphericity, decreased SDI (SDI 17: 6.7 ± 3.3% vs. 2.9 ± 3.7%) (P < 0.05 for all), and improved agreement of EDV and ESV with CMR. Impact of software sensitivity in LV endocardium detection on LV parameters was related to image quality: higher on SDI in pts with suboptimal quality (SDI 17 bias 4.5% vs. 3.2%, P < 0.05); higher on LV volumes in patients with optimal quality (EDV bias 14 ml vs. 19 ml, ESV bias 5 ml vs. 9 ml; P = 0.01). Conclusions Manual editing, software settings and image quality significantly impact on 3D LV volumes and dyssynchrony assessment.
Literatur
1.
Zurück zum Zitat Sonne C, Sugeng L, Takeuchi M, Weinert L, Childers R, Watanabe N et al (2009) Real-time 3-dimensional echocardiographic assessment of left ventricular dyssynchrony: pitfalls in patients with dilated cardiomyopathy. JACC Cardiovasc Imaging 2:802–812PubMedCrossRef Sonne C, Sugeng L, Takeuchi M, Weinert L, Childers R, Watanabe N et al (2009) Real-time 3-dimensional echocardiographic assessment of left ventricular dyssynchrony: pitfalls in patients with dilated cardiomyopathy. JACC Cardiovasc Imaging 2:802–812PubMedCrossRef
2.
Zurück zum Zitat Kadish AH, Reiffel JA, Naccarelli GV, DiMarco JP (2008) Device therapies in the post-myocardial infarction patient with left ventricular dysfunction. Am J Cardiol 102:29G–37GPubMedCrossRef Kadish AH, Reiffel JA, Naccarelli GV, DiMarco JP (2008) Device therapies in the post-myocardial infarction patient with left ventricular dysfunction. Am J Cardiol 102:29G–37GPubMedCrossRef
3.
Zurück zum Zitat Nanthakumar K, Epstein AE, Kay GN, Plumb VJ, Lee DS (2004) Prophylactic implantable cardioverter-defibrillator therapy in patients with left ventricular systolic dysfunction: a pooled analysis of 10 primary prevention trials. J Am Coll Cardiol 44:2166–2172PubMedCrossRef Nanthakumar K, Epstein AE, Kay GN, Plumb VJ, Lee DS (2004) Prophylactic implantable cardioverter-defibrillator therapy in patients with left ventricular systolic dysfunction: a pooled analysis of 10 primary prevention trials. J Am Coll Cardiol 44:2166–2172PubMedCrossRef
5.
Zurück zum Zitat Otto CM, Salerno CT (2005) Timing of surgery in asymptomatic mitral regurgitation. N Engl J Med 352:928–929PubMedCrossRef Otto CM, Salerno CT (2005) Timing of surgery in asymptomatic mitral regurgitation. N Engl J Med 352:928–929PubMedCrossRef
6.
Zurück zum Zitat Wang TJ, Evans JC, Benjamin EJ, Levy D, LeRoy EC, Vasan RS (2003) Natural history of asymptomatic left ventricular systolic dysfunction in the community. Circulation 108:977–982PubMedCrossRef Wang TJ, Evans JC, Benjamin EJ, Levy D, LeRoy EC, Vasan RS (2003) Natural history of asymptomatic left ventricular systolic dysfunction in the community. Circulation 108:977–982PubMedCrossRef
7.
Zurück zum Zitat Lang RM, Mor-Avi V, Sugeng L, Nieman PS, Sahn DJ (2006) Three-dimensional echocardiography: the benefits of the additional dimension. J Am Coll Cardiol 48:2053–2069PubMedCrossRef Lang RM, Mor-Avi V, Sugeng L, Nieman PS, Sahn DJ (2006) Three-dimensional echocardiography: the benefits of the additional dimension. J Am Coll Cardiol 48:2053–2069PubMedCrossRef
8.
Zurück zum Zitat Jenkins C, Bricknell K, Chan J, Hanekom L, Marwick TH (2007) Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction. Am J Cardiol 99:300–306PubMedCrossRef Jenkins C, Bricknell K, Chan J, Hanekom L, Marwick TH (2007) Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction. Am J Cardiol 99:300–306PubMedCrossRef
9.
Zurück zum Zitat Shimada YJ, Shiota T (2011) A meta-analysis and investigation for the source of bias of left ventricular volumes and function by three-dimensional echocardiography in comparison with magnetic resonance imaging. Am J Cardiol 107:126–138PubMedCrossRef Shimada YJ, Shiota T (2011) A meta-analysis and investigation for the source of bias of left ventricular volumes and function by three-dimensional echocardiography in comparison with magnetic resonance imaging. Am J Cardiol 107:126–138PubMedCrossRef
10.
Zurück zum Zitat Jenkins C, Bricknell K, Hanekom L, Marwick TH (2004) Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography. J Am Coll Cardiol 44:878–886PubMedCrossRef Jenkins C, Bricknell K, Hanekom L, Marwick TH (2004) Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography. J Am Coll Cardiol 44:878–886PubMedCrossRef
11.
Zurück zum Zitat Mor-Avi V, Jenkins C, Kuhl HP, Nesser HJ, Marwick T, Franke A et al (2008) Real-time 3-dimensional echocardiographic quantification of left ventricular volumes: multicenter study for validation with magnetic resonance imaging and investigation of sources of error. JACC Cardiovasc Imaging 1:413–423PubMedCrossRef Mor-Avi V, Jenkins C, Kuhl HP, Nesser HJ, Marwick T, Franke A et al (2008) Real-time 3-dimensional echocardiographic quantification of left ventricular volumes: multicenter study for validation with magnetic resonance imaging and investigation of sources of error. JACC Cardiovasc Imaging 1:413–423PubMedCrossRef
12.
Zurück zum Zitat Sugeng L, Mor-Avi V, Weinert L, Niel J, Ebner C, Steringer-Mascherbauer R et al (2006) Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference. Circulation 114:654–661PubMedCrossRef Sugeng L, Mor-Avi V, Weinert L, Niel J, Ebner C, Steringer-Mascherbauer R et al (2006) Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference. Circulation 114:654–661PubMedCrossRef
13.
Zurück zum Zitat Muraru D, Badano LP, Piccoli G, Gianfagna P, Del Mestre L, Ermacora D et al (2010) Validation of a novel automated border-detection algorithm for rapid and accurate quantitation of left ventricular volumes based on three-dimensional echocardiography. Eur J Echocardiogr 11:359–368PubMedCrossRef Muraru D, Badano LP, Piccoli G, Gianfagna P, Del Mestre L, Ermacora D et al (2010) Validation of a novel automated border-detection algorithm for rapid and accurate quantitation of left ventricular volumes based on three-dimensional echocardiography. Eur J Echocardiogr 11:359–368PubMedCrossRef
14.
Zurück zum Zitat Kapetanakis S, Kearney MT, Siva A, Gall N, Cooklin M, Monaghan MJ (2005) Real-time three-dimensional echocardiography: a novel technique to quantify global left ventricular mechanical dyssynchrony. Circulation 112:992–1000PubMedCrossRef Kapetanakis S, Kearney MT, Siva A, Gall N, Cooklin M, Monaghan MJ (2005) Real-time three-dimensional echocardiography: a novel technique to quantify global left ventricular mechanical dyssynchrony. Circulation 112:992–1000PubMedCrossRef
15.
Zurück zum Zitat Marsan NA, Bleeker GB, Ypenburg C, Ghio S, Van de Veire NR, Holman ER et al (2008) Real-time three-dimensional echocardiography permits quantification of left ventricular mechanical dyssynchrony and predicts acute response to cardiac resynchronization therapy. J Cardiovasc Electrophysiol 19:392–399PubMedCrossRef Marsan NA, Bleeker GB, Ypenburg C, Ghio S, Van de Veire NR, Holman ER et al (2008) Real-time three-dimensional echocardiography permits quantification of left ventricular mechanical dyssynchrony and predicts acute response to cardiac resynchronization therapy. J Cardiovasc Electrophysiol 19:392–399PubMedCrossRef
16.
Zurück zum Zitat Soliman OI, van Dalen BM, Nemes A, van der Zwaan HB, Vletter WB, ten Cate FJ et al (2009) Quantification of left ventricular systolic dyssynchrony by real-time three-dimensional echocardiography. J Am Soc Echocardiogr 22:232–239PubMedCrossRef Soliman OI, van Dalen BM, Nemes A, van der Zwaan HB, Vletter WB, ten Cate FJ et al (2009) Quantification of left ventricular systolic dyssynchrony by real-time three-dimensional echocardiography. J Am Soc Echocardiogr 22:232–239PubMedCrossRef
17.
Zurück zum Zitat Deplagne A, Bordachar P, Reant P, Montaudon M, Reuter S, Laborderie J et al (2009) Additional value of three-dimensional echocardiography in patients with cardiac resynchronization therapy. Arch Cardiovasc Dis 102:497–508PubMedCrossRef Deplagne A, Bordachar P, Reant P, Montaudon M, Reuter S, Laborderie J et al (2009) Additional value of three-dimensional echocardiography in patients with cardiac resynchronization therapy. Arch Cardiovasc Dis 102:497–508PubMedCrossRef
18.
Zurück zum Zitat Kapetanakis S, Bhan A, Murgatroyd F, Kearney MT, Gall N, Zhang Q et al (2011) Real-time 3D echo in patient selection for cardiac resynchronization therapy. JACC Cardiovasc Imaging 4:16–26PubMedCrossRef Kapetanakis S, Bhan A, Murgatroyd F, Kearney MT, Gall N, Zhang Q et al (2011) Real-time 3D echo in patient selection for cardiac resynchronization therapy. JACC Cardiovasc Imaging 4:16–26PubMedCrossRef
19.
Zurück zum Zitat Gimenes VM, Vieira ML, Andrade MM, Pinheiro J Jr, Hotta VT, Mathias W Jr (2008) Standard values for real-time transthoracic three-dimensional echocardiographic dyssynchrony indexes in a normal population. J Am Soc Echocardiogr 21:1229–1235PubMedCrossRef Gimenes VM, Vieira ML, Andrade MM, Pinheiro J Jr, Hotta VT, Mathias W Jr (2008) Standard values for real-time transthoracic three-dimensional echocardiographic dyssynchrony indexes in a normal population. J Am Soc Echocardiogr 21:1229–1235PubMedCrossRef
20.
Zurück zum Zitat Liodakis E, Sharef OA, Dawson D, Nihoyannopoulos P (2009) The use of real-time three-dimensional echocardiography for assessing mechanical synchronicity. Heart 95:1865–1871PubMedCrossRef Liodakis E, Sharef OA, Dawson D, Nihoyannopoulos P (2009) The use of real-time three-dimensional echocardiography for assessing mechanical synchronicity. Heart 95:1865–1871PubMedCrossRef
21.
Zurück zum Zitat Lang RM, Mor-Avi V, Dent JM, Kramer CM (2009) Three-dimensional echocardiography: is it ready for everyday clinical use? JACC Cardiovasc Imaging 2:114–117PubMedCrossRef Lang RM, Mor-Avi V, Dent JM, Kramer CM (2009) Three-dimensional echocardiography: is it ready for everyday clinical use? JACC Cardiovasc Imaging 2:114–117PubMedCrossRef
22.
Zurück zum Zitat Monaghan M, Bax J, Franke A, Kamp O, Kuehl H, Nihoyannopoulos P et al (2009) 3-dimensional echocardiographic assessment of left ventricular dyssynchrony: an alternative viewpoint. JACC Cardiovasc Imaging 2:1334–1335PubMedCrossRef Monaghan M, Bax J, Franke A, Kamp O, Kuehl H, Nihoyannopoulos P et al (2009) 3-dimensional echocardiographic assessment of left ventricular dyssynchrony: an alternative viewpoint. JACC Cardiovasc Imaging 2:1334–1335PubMedCrossRef
23.
Zurück zum Zitat Willems JL, Robles de Medina EO, Bernard R, Coumel P, Fisch C, Krikler D et al (1985) Criteria for intraventricular conduction disturbances and pre-excitation. World Health Organizational/International Society and Federation for Cardiology Task Force Ad Hoc. J Am Coll Cardiol 5:1261–1275PubMedCrossRef Willems JL, Robles de Medina EO, Bernard R, Coumel P, Fisch C, Krikler D et al (1985) Criteria for intraventricular conduction disturbances and pre-excitation. World Health Organizational/International Society and Federation for Cardiology Task Force Ad Hoc. J Am Coll Cardiol 5:1261–1275PubMedCrossRef
24.
Zurück zum Zitat Senior R, Becher H, Monaghan M, Agati L, Zamorano J, Vanoverschelde JL et al (2009) Contrast echocardiography: evidence-based recommendations by European Association of Echocardiography. Eur J Echocardiogr 10:194–212PubMedCrossRef Senior R, Becher H, Monaghan M, Agati L, Zamorano J, Vanoverschelde JL et al (2009) Contrast echocardiography: evidence-based recommendations by European Association of Echocardiography. Eur J Echocardiogr 10:194–212PubMedCrossRef
25.
Zurück zum Zitat Nucifora G, Badano LP, Dall’Armellina E, Gianfagna P, Allocca G, Fioretti PM (2009) Fast data acquisition and analysis with real time triplane echocardiography for the assessment of left ventricular size and function: a validation study. Echocardiography 26:66–75PubMedCrossRef Nucifora G, Badano LP, Dall’Armellina E, Gianfagna P, Allocca G, Fioretti PM (2009) Fast data acquisition and analysis with real time triplane echocardiography for the assessment of left ventricular size and function: a validation study. Echocardiography 26:66–75PubMedCrossRef
26.
Zurück zum Zitat Koos R, Neizel M, Schummers G, Krombach GA, Stanzel S, Güntheret RW et al (2008) Feasibility and initial experience of assessment of mechanical dyssynchrony using cardiovascular magnetic resonance and semi-automatic border detection. J Cardiovasc Magn Reson 10:49PubMedCrossRef Koos R, Neizel M, Schummers G, Krombach GA, Stanzel S, Güntheret RW et al (2008) Feasibility and initial experience of assessment of mechanical dyssynchrony using cardiovascular magnetic resonance and semi-automatic border detection. J Cardiovasc Magn Reson 10:49PubMedCrossRef
27.
Zurück zum Zitat Tatsioni A, Zarin DA, Aronson N, Samson DJ, Flamm CR, Schmid C et al (2005) Challenges in systematic reviews of diagnostic technologies. Ann Intern Med 142:1048–1055PubMed Tatsioni A, Zarin DA, Aronson N, Samson DJ, Flamm CR, Schmid C et al (2005) Challenges in systematic reviews of diagnostic technologies. Ann Intern Med 142:1048–1055PubMed
28.
Zurück zum Zitat Chung ES, Leon AR, Tavazzi L, Sun JP, Nihoyannopoulos P, Merlino J et al (2008) Results of the predictors of response to CRT (PROSPECT) trial. Circulation 117:2608–2616PubMedCrossRef Chung ES, Leon AR, Tavazzi L, Sun JP, Nihoyannopoulos P, Merlino J et al (2008) Results of the predictors of response to CRT (PROSPECT) trial. Circulation 117:2608–2616PubMedCrossRef
29.
Zurück zum Zitat Monaghan M (2009) Echocardiographic assessment of left ventricular dyssynchrony–is three-dimensional echocardiography just the latest kid on the block? J Am Soc Echocardiogr 22:240–241PubMedCrossRef Monaghan M (2009) Echocardiographic assessment of left ventricular dyssynchrony–is three-dimensional echocardiography just the latest kid on the block? J Am Soc Echocardiogr 22:240–241PubMedCrossRef
30.
Zurück zum Zitat Macron L, Lim P, Bensaid A, Nahum J, Dussault C, Mitchell-Heggs L et al (2010) Single-beat versus multibeat real-time 3D echocardiography for assessing left ventricular volumes and ejection fraction: a comparison study with cardiac magnetic resonance. Circ Cardiovasc Imaging 3:450–455PubMedCrossRef Macron L, Lim P, Bensaid A, Nahum J, Dussault C, Mitchell-Heggs L et al (2010) Single-beat versus multibeat real-time 3D echocardiography for assessing left ventricular volumes and ejection fraction: a comparison study with cardiac magnetic resonance. Circ Cardiovasc Imaging 3:450–455PubMedCrossRef
31.
Zurück zum Zitat Yu CM, Bax JJ, Gorcsan J III (2009) Critical appraisal of methods to assess mechanical dyssynchrony. Curr Opin Cardiol 24:18–28PubMedCrossRef Yu CM, Bax JJ, Gorcsan J III (2009) Critical appraisal of methods to assess mechanical dyssynchrony. Curr Opin Cardiol 24:18–28PubMedCrossRef
32.
Zurück zum Zitat Agarwal R, Beshai JF, Lang RM (2009) Can real-time three-dimensional echocardiography be used reliably for the assessment of left ventricular dyssynchrony? Arch Cardiovasc Dis 102:469–472PubMedCrossRef Agarwal R, Beshai JF, Lang RM (2009) Can real-time three-dimensional echocardiography be used reliably for the assessment of left ventricular dyssynchrony? Arch Cardiovasc Dis 102:469–472PubMedCrossRef
33.
Zurück zum Zitat Jenkins C, Marwick TH (2009) Baseline and follow-up assessment of regional left ventricular volume using 3-Dimensional echocardiography: comparison with cardiac magnetic resonance. Cardiovasc Ultrasound 7:55PubMedCrossRef Jenkins C, Marwick TH (2009) Baseline and follow-up assessment of regional left ventricular volume using 3-Dimensional echocardiography: comparison with cardiac magnetic resonance. Cardiovasc Ultrasound 7:55PubMedCrossRef
34.
Zurück zum Zitat Macron L, Lim P, Bensaid A, Nahum J, Dussault C, Mitchell-Heggs L, Dubois-Randé JL, Deux JF, Gueret P (2010) Single-beat versus multibeat real-time 3D echocardiography for assessing left ventricular volumes and ejection fraction: a comparison study with cardiac magnetic resonance. Circ Cardiovasc Imaging 3:450–455PubMedCrossRef Macron L, Lim P, Bensaid A, Nahum J, Dussault C, Mitchell-Heggs L, Dubois-Randé JL, Deux JF, Gueret P (2010) Single-beat versus multibeat real-time 3D echocardiography for assessing left ventricular volumes and ejection fraction: a comparison study with cardiac magnetic resonance. Circ Cardiovasc Imaging 3:450–455PubMedCrossRef
Metadaten
Titel
Sources of variation and bias in assessing left ventricular volumes and dyssynchrony using three-dimensional echocardiography
verfasst von
Denisa Muraru
Luigi P. Badano
Davide Ermacora
Gianluca Piccoli
Sabino Iliceto
Publikationsdatum
01.08.2012
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 6/2012
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-011-9985-0

Weitere Artikel der Ausgabe 6/2012

The International Journal of Cardiovascular Imaging 6/2012 Zur Ausgabe

„Jeder Fall von plötzlichem Tod muss obduziert werden!“

17.05.2024 Plötzlicher Herztod Nachrichten

Ein signifikanter Anteil der Fälle von plötzlichem Herztod ist genetisch bedingt. Um ihre Verwandten vor diesem Schicksal zu bewahren, sollten jüngere Personen, die plötzlich unerwartet versterben, ausnahmslos einer Autopsie unterzogen werden.

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Schlechtere Vorhofflimmern-Prognose bei kleinem linken Ventrikel

17.05.2024 Vorhofflimmern Nachrichten

Nicht nur ein vergrößerter, sondern auch ein kleiner linker Ventrikel ist bei Vorhofflimmern mit einer erhöhten Komplikationsrate assoziiert. Der Zusammenhang besteht nach Daten aus China unabhängig von anderen Risikofaktoren.

Semaglutid bei Herzinsuffizienz: Wie erklärt sich die Wirksamkeit?

17.05.2024 Herzinsuffizienz Nachrichten

Bei adipösen Patienten mit Herzinsuffizienz des HFpEF-Phänotyps ist Semaglutid von symptomatischem Nutzen. Resultiert dieser Benefit allein aus der Gewichtsreduktion oder auch aus spezifischen Effekten auf die Herzinsuffizienz-Pathogenese? Eine neue Analyse gibt Aufschluss.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.