Skip to main content
Erschienen in: European Radiology 11/2020

27.06.2020 | Nuclear Medicine

Stimulation of the hepatic arterial buffer response using exogenous adenosine: hepatic rest/stress perfusion imaging

verfasst von: Georgia Keramida, Sima Gregg, A. Michael Peters

Erschienen in: European Radiology | Ausgabe 11/2020

Einloggen, um Zugang zu erhalten

Abstract

Objectives

The hepatic arterial buffer response is a mechanism mediated by adenosine whereby hepatic arterial perfusion (HAP) increases when portal flow decreases, and is implicated in liver disease. The first study aim was to measure HAP in patients undergoing myocardial perfusion imaging (MPI), thus developing hepatic arterial rest/stress perfusion imaging (HAPI). The second aim was to compare adenosine-induced changes in splenic perfusion (SP) and HAP with corresponding changes in myocardial blood flow (MBF).

Methods

Patients had MPI with 82Rb PET/CT using adenosine (n = 45) or regadenoson (n = 33) for stressing. SP and HAP were measured using a first-pass technique that gives HAP rather than total hepatic perfusion. Renal perfusion (RP) was also measured.

Results

Mean MBF and HAP increased after both adenosine ([stress-rest]/rest 1.1 and 0.8) and regadenoson (1.4 and 0.6), but the respective changes did not correlate. After adenosine, SP (− 0.48) and RP (− 0.26) both decreased. The change in SP correlated positively with the change in MBF (r = 0.36; p = 0.015) but did not correlate with change in HAP. After regadenoson, SP (0.2) and RP (0.2) both increased. The changes in SP correlated with the changes in MBF (r = 0.39; p = 0.025) and HAP (r = 0.39; p = 0.02). Changes in RP correlated with changes in HAP (r = 0.51; p = 0.0008) but not MBF. Resting SP (r = 0.32; p = 0.004), but not resting HAP, correlated with hepatic fat burden. Adenosine-induced change in HAP also correlated with hepatic fat (r = 0.29; p = 0.05).

Conclusion

HAPI could be a useful new hepatic function test. Neither splenic ‘switch-off’ nor hepatic arterial ‘switch-on’ identifies adequacy of stress in MPI.

Key Points

• This article describes a new method for assessing arterial perfusion of the liver and its capacity to respond to an infusion of adenosine, a substance that normally ‘drives’ hepatic arterial flow.
• Hepatic arterial flow increased in response to adenosine, sometimes dramatically. Adenosine is already used clinically to stimulate myocardial blood flow in patients with suspected coronary disease, but the increase in flow did not correlate with the corresponding increase in hepatic arterial flow.
• Analogous to the use of adenosine in the myocardium, the increase in hepatic arterial flow in response to adenosine has the potential to be a new clinically useful method for the evaluation of hepatic arterial haemodynamics in liver disease.
Literatur
1.
Zurück zum Zitat Lautt WW (2007) Regulatory processes interacting to maintain hepatic blood flow constancy: vascular compliance, hepatic arterial buffer response, hepatorenal reflex, liver regeneration, escape from vasoconstriction. Hepatol Res 37:891–903CrossRef Lautt WW (2007) Regulatory processes interacting to maintain hepatic blood flow constancy: vascular compliance, hepatic arterial buffer response, hepatorenal reflex, liver regeneration, escape from vasoconstriction. Hepatol Res 37:891–903CrossRef
2.
Zurück zum Zitat Eipel C, Abshagen K, Vollmar B (2010) Regulation of hepatic blood flow: the hepatic arterial buffer response revisited. World J Gastroenterol 16:6046–6057CrossRef Eipel C, Abshagen K, Vollmar B (2010) Regulation of hepatic blood flow: the hepatic arterial buffer response revisited. World J Gastroenterol 16:6046–6057CrossRef
3.
Zurück zum Zitat Zhu X, Shiba H, Zhu Y et al (2016) Adenosine increases hepatic artery flow in liver transplant recipients: a pilot study. Transplant Proc 48:116–119 Zhu X, Shiba H, Zhu Y et al (2016) Adenosine increases hepatic artery flow in liver transplant recipients: a pilot study. Transplant Proc 48:116–119
4.
Zurück zum Zitat Browse DJ, Mathie RT, Benjamin IS, Alexander B (2003) The role of ATP and adenosine in the control of hepatic blood flow in the rabbit liver in vivo. Comp Hepatol 2(1):9CrossRef Browse DJ, Mathie RT, Benjamin IS, Alexander B (2003) The role of ATP and adenosine in the control of hepatic blood flow in the rabbit liver in vivo. Comp Hepatol 2(1):9CrossRef
5.
Zurück zum Zitat Manisty C, Ripley DP, Herrey AS et al (2015) Splenic switch-off: a tool to assess stress adequacy in adenosine perfusion cardiac MR imaging. Radiology 276:732–740 Manisty C, Ripley DP, Herrey AS et al (2015) Splenic switch-off: a tool to assess stress adequacy in adenosine perfusion cardiac MR imaging. Radiology 276:732–740
6.
Zurück zum Zitat Hosking A, Koulouroudias M, Zemrak F et al (2017) Evaluation of splenic switch off in a tertiary imaging centre: validation and assessment of utility. Eur Heart J Cardiovasc Imaging 18:1216–1221 Hosking A, Koulouroudias M, Zemrak F et al (2017) Evaluation of splenic switch off in a tertiary imaging centre: validation and assessment of utility. Eur Heart J Cardiovasc Imaging 18:1216–1221
7.
Zurück zum Zitat Tarantino G, Scalera A, Finelli C (2013) Liver-spleen axis: intersection between immunity, infections and metabolism. World J Gastroenterol 19:3534–3542CrossRef Tarantino G, Scalera A, Finelli C (2013) Liver-spleen axis: intersection between immunity, infections and metabolism. World J Gastroenterol 19:3534–3542CrossRef
8.
Zurück zum Zitat Peters AM, Brown J, Crossman D et al (1990) Non-invasive measurement of renal blood flow with Tc-99m DTPA in the evaluation of patients with suspected renovascular hypertension. J Nucl Med 31:1980–1985 Peters AM, Brown J, Crossman D et al (1990) Non-invasive measurement of renal blood flow with Tc-99m DTPA in the evaluation of patients with suspected renovascular hypertension. J Nucl Med 31:1980–1985
9.
Zurück zum Zitat Mathie RT (1986) Hepatic blood flow measurement with inert gas clearance. J Surg Res 41:92–110CrossRef Mathie RT (1986) Hepatic blood flow measurement with inert gas clearance. J Surg Res 41:92–110CrossRef
10.
Zurück zum Zitat Senthamizhchelvan S, Bravo PE, Lodge MA, Merrill J, Bengel FM, Sgouros G (2011) Radiation dosimetry of Rb-82 in humans under pharmacological stress. J Nucl Med 52:485–491 Senthamizhchelvan S, Bravo PE, Lodge MA, Merrill J, Bengel FM, Sgouros G (2011) Radiation dosimetry of Rb-82 in humans under pharmacological stress. J Nucl Med 52:485–491
11.
Zurück zum Zitat deKemp RA, Declerck J, Klein R et al (2013) Multisoftware reproducibility study of stress and rest myocardial blood flow assessed with 3D dynamic PET/CT and a 1-tissue-compartment model of 82Rb kinetics. J Nucl Med 54:571–577 deKemp RA, Declerck J, Klein R et al (2013) Multisoftware reproducibility study of stress and rest myocardial blood flow assessed with 3D dynamic PET/CT and a 1-tissue-compartment model of 82Rb kinetics. J Nucl Med 54:571–577
12.
Zurück zum Zitat Lortie M, Beanlands RSB, Yoshinaga K, Klein R, Da Silva JN, deKemp RA (2007) Quantification of myocardial blood flow with 82Rb. dynamic PET imaging. Eur J Nucl Med Mol Imaging 34:1765–1774CrossRef Lortie M, Beanlands RSB, Yoshinaga K, Klein R, Da Silva JN, deKemp RA (2007) Quantification of myocardial blood flow with 82Rb. dynamic PET imaging. Eur J Nucl Med Mol Imaging 34:1765–1774CrossRef
13.
Zurück zum Zitat Boyce CJ, Pickhardt PJ, Kim DH et al (2010) Hepatic steatosis (fatty liver disease) in asymptomatic adults identified by unenhanced low-dose AJR Am J Roentgenol 94:623–628 Boyce CJ, Pickhardt PJ, Kim DH et al (2010) Hepatic steatosis (fatty liver disease) in asymptomatic adults identified by unenhanced low-dose AJR Am J Roentgenol 94:623–628
14.
Zurück zum Zitat Miles KA, Hayball M, Dixon AK (1991) Colour perfusion imaging: a new application of computed tomography. Lancet 337(8742):643–645CrossRef Miles KA, Hayball M, Dixon AK (1991) Colour perfusion imaging: a new application of computed tomography. Lancet 337(8742):643–645CrossRef
15.
Zurück zum Zitat Bell SD, Peters AM (1991) Measurement of blood flow from first-pass radionuclide angiography: influence of bolus volume. Eur J Nucl Med 18:885–888CrossRef Bell SD, Peters AM (1991) Measurement of blood flow from first-pass radionuclide angiography: influence of bolus volume. Eur J Nucl Med 18:885–888CrossRef
16.
Zurück zum Zitat Choi Y, Huang S-C, Hawkins RA et al (1993) A simplified method for quantification of myocardial blood flow using nitrogen-13-ammonia and dynamic PET. J NucI Med 34:488–497 Choi Y, Huang S-C, Hawkins RA et al (1993) A simplified method for quantification of myocardial blood flow using nitrogen-13-ammonia and dynamic PET. J NucI Med 34:488–497
17.
Zurück zum Zitat Bergmann SR (1997) Clinical applications of myocardial perfusion assessments made with oxygen-15 water and positron emission tomography. Cardiology 88:71–79CrossRef Bergmann SR (1997) Clinical applications of myocardial perfusion assessments made with oxygen-15 water and positron emission tomography. Cardiology 88:71–79CrossRef
18.
Zurück zum Zitat Holroyd AM, Peters AM (1980) The measurement of arterial perfusion of the liver in man using the radioisotope xenon-133. Br J Surg 67(3):178–180 Holroyd AM, Peters AM (1980) The measurement of arterial perfusion of the liver in man using the radioisotope xenon-133. Br J Surg 67(3):178–180
19.
Zurück zum Zitat Hashimoto K, Murakami T, Dono K et al (2007) Quantitative tissue blood flow measurement of the liver parenchyma: comparison between xenon CT and perfusion CT. Dig Dis Sci 52:943–949 Hashimoto K, Murakami T, Dono K et al (2007) Quantitative tissue blood flow measurement of the liver parenchyma: comparison between xenon CT and perfusion CT. Dig Dis Sci 52:943–949
20.
Zurück zum Zitat Materne R, Smith AM, Peeters F et al (2002) Assessment of hepatic perfusion parameters with dynamic MRI. Magn Reson Med 47:135–142 Materne R, Smith AM, Peeters F et al (2002) Assessment of hepatic perfusion parameters with dynamic MRI. Magn Reson Med 47:135–142
21.
Zurück zum Zitat Tsushima Y, Endo K (2000) Spleen enlargement in patients with nonalcoholic fatty liver: correlation between degree of fatty infiltration in liver and size of spleen. Dig Dis Sci 45:196–200CrossRef Tsushima Y, Endo K (2000) Spleen enlargement in patients with nonalcoholic fatty liver: correlation between degree of fatty infiltration in liver and size of spleen. Dig Dis Sci 45:196–200CrossRef
22.
Zurück zum Zitat Keramida G, Dunford A, Kaya G, Anagnostopoulos CD, Peters AM (2018) Hepato-splenic axis: hepatic and splenic metabolic activities are linked. Am J Nucl Med Mol Imaging 8:228–238PubMedPubMedCentral Keramida G, Dunford A, Kaya G, Anagnostopoulos CD, Peters AM (2018) Hepato-splenic axis: hepatic and splenic metabolic activities are linked. Am J Nucl Med Mol Imaging 8:228–238PubMedPubMedCentral
23.
Zurück zum Zitat Peters AM, Klonizakis I, Lavender JP, Lewis SM (1980) Use of indium-111-labelled platelets to measure spleen function. Br J Haematol 46:587–593CrossRef Peters AM, Klonizakis I, Lavender JP, Lewis SM (1980) Use of indium-111-labelled platelets to measure spleen function. Br J Haematol 46:587–593CrossRef
24.
Zurück zum Zitat Agmon Y, Dinour D, Brezis M (1993) Disparate effects of adenosine A1- and A2-receptor agonists on intrarenal blood flow. Am J Physiol 265(6):F802–F806PubMed Agmon Y, Dinour D, Brezis M (1993) Disparate effects of adenosine A1- and A2-receptor agonists on intrarenal blood flow. Am J Physiol 265(6):F802–F806PubMed
Metadaten
Titel
Stimulation of the hepatic arterial buffer response using exogenous adenosine: hepatic rest/stress perfusion imaging
verfasst von
Georgia Keramida
Sima Gregg
A. Michael Peters
Publikationsdatum
27.06.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 11/2020
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-020-06984-6

Weitere Artikel der Ausgabe 11/2020

European Radiology 11/2020 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.