Skip to main content
Erschienen in: Journal of Anesthesia 2/2014

01.04.2014 | Original Article

Stroke volume-directed administration of hydroxyethyl starch (HES 130/0.4) and Ringer’s acetate in prone position during neurosurgery: a randomized controlled trial

verfasst von: Ann-Christine Lindroos, Tomohisa Niiya, Tarja Randell, Tomi T. Niemi

Erschienen in: Journal of Anesthesia | Ausgabe 2/2014

Einloggen, um Zugang zu erhalten

Abstract

Purpose

General anesthesia in the prone position is associated with hypotension. We studied stroke volume (SV)-directed administration of hydroxyethyl starch (HES 130 kDa/0.4) and Ringer’s acetate (RAC) in neurosurgical patients operated on in a prone position to determine the volumes required for stable hemodynamics and possible coagulatory effects.

Methods

Thirty elective neurosurgical patients received either HES (n = 15) or RAC (n = 15). Before positioning, SV measured by arterial pressure waveform analysis was maximized by fluid boluses until SV did not increase more than 10 %. SV was maintained by repeated administration of fluid. RAC 3 ml/kg/h was infused in both groups. Thromboelastometry assessed coagulation. Mann–Whitney U test, Wilcoxon signed-rank test, ANOVA on ranks, and a linear mixed model were applied.

Results

Comparable hemodynamics were achieved with the mean cumulative (SD) boluses of HES or RAC 240 (51) or 267 (62) ml (P = 0.207) before positioning, 340 (124) or 453 (160) ml (P = 0.039) 30 min after positioning, and 440 (229) or 653 (368) ml at the end of surgery (P = 0.067). The mean dose of basal RAC infusion was 813 (235) and 868 (354) ml (P = 0.620) in the HES and RAC group, respectively. Formation and maximum strength of the fibrin clot were decreased in the HES group. Intraoperative blood loss was comparable between groups (P = 0.861).

Conclusion

The amount of RAC needed in the prone position was 25 % greater. The cumulative dose of 440 ml HES induced a slight disturbance in fibrin formation and clot strength. We suggest cautious administration of HES during neurosurgery.
Literatur
1.
Zurück zum Zitat St-Arnaud D, Paquin MJ. Safe positioning for neurosurgical patients. AORN J. 2008;87:1156–68.PubMedCrossRef St-Arnaud D, Paquin MJ. Safe positioning for neurosurgical patients. AORN J. 2008;87:1156–68.PubMedCrossRef
2.
Zurück zum Zitat Tetzlaff JE, O’Hara JF Jr, Yoon HJ, Schubert A. Heart rate variability and the prone position under general versus spinal anesthesia. J Clin Anesth. 1998;10:656–9.PubMedCrossRef Tetzlaff JE, O’Hara JF Jr, Yoon HJ, Schubert A. Heart rate variability and the prone position under general versus spinal anesthesia. J Clin Anesth. 1998;10:656–9.PubMedCrossRef
3.
Zurück zum Zitat Edgcombe H, Carter K, Yarrow S. Anaesthesia in the prone position. Br J Anaesth. 2008;100:165–83.PubMedCrossRef Edgcombe H, Carter K, Yarrow S. Anaesthesia in the prone position. Br J Anaesth. 2008;100:165–83.PubMedCrossRef
4.
Zurück zum Zitat Gan TJ, Soppitt A, Maroof M, el-Moalem H, Robertson KM, Moretti E, Dwane P, Glass PS. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesíology. 2002;97:820–6.PubMedCrossRef Gan TJ, Soppitt A, Maroof M, el-Moalem H, Robertson KM, Moretti E, Dwane P, Glass PS. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesíology. 2002;97:820–6.PubMedCrossRef
5.
Zurück zum Zitat Giglio MT, Marucci M, Testini M, Brienza N. Goal-directed haemodynamic therapy and gastrointestinal complications in major surgery: a meta-analysis of randomized controlled trials. Br J Anaesth. 2009;103:637–46.PubMedCrossRef Giglio MT, Marucci M, Testini M, Brienza N. Goal-directed haemodynamic therapy and gastrointestinal complications in major surgery: a meta-analysis of randomized controlled trials. Br J Anaesth. 2009;103:637–46.PubMedCrossRef
6.
Zurück zum Zitat Hiltebrand LB, Kimberger O, Arnberger M, Brandt S, Kurz A, Sigurdsson GH. Crystalloids versus colloids for goal-directed fluid therapy in major surgery. Crit Care. 2009;13:R40.PubMedCentralPubMedCrossRef Hiltebrand LB, Kimberger O, Arnberger M, Brandt S, Kurz A, Sigurdsson GH. Crystalloids versus colloids for goal-directed fluid therapy in major surgery. Crit Care. 2009;13:R40.PubMedCentralPubMedCrossRef
7.
Zurück zum Zitat Kozek-Langenecker SA. Effects of hydroxyethyl starch solutions on hemostasis. Anesthesiology. 2005;103:654–60.PubMedCrossRef Kozek-Langenecker SA. Effects of hydroxyethyl starch solutions on hemostasis. Anesthesiology. 2005;103:654–60.PubMedCrossRef
8.
Zurück zum Zitat Palmer JD, Sparrow OC, Iannotti F. Postoperative hematoma: a 5-year survey and identification of avoidable risk factors. Neurosurgery. 1994;35:1061–4.PubMedCrossRef Palmer JD, Sparrow OC, Iannotti F. Postoperative hematoma: a 5-year survey and identification of avoidable risk factors. Neurosurgery. 1994;35:1061–4.PubMedCrossRef
9.
Zurück zum Zitat Niemi TT, Suojaranta-Ylinen RT, Kukkonen SI, Kuitunen AH. Gelatin and hydroxyethyl starch, but not albumin, impair hemostasis after cardiac surgery. Anesth Analg. 2006;102:998–1006.PubMedCrossRef Niemi TT, Suojaranta-Ylinen RT, Kukkonen SI, Kuitunen AH. Gelatin and hydroxyethyl starch, but not albumin, impair hemostasis after cardiac surgery. Anesth Analg. 2006;102:998–1006.PubMedCrossRef
10.
Zurück zum Zitat Hatada T, Kusunoki M, Sakiyama T, Sakanoue Y, Yamamura T, Okutani R, Kono K, Ishida H, Utsunomiya J. Hemodynamics in the prone jackknife position during surgery. Am J Surg. 1991;162:55–8.PubMedCrossRef Hatada T, Kusunoki M, Sakiyama T, Sakanoue Y, Yamamura T, Okutani R, Kono K, Ishida H, Utsunomiya J. Hemodynamics in the prone jackknife position during surgery. Am J Surg. 1991;162:55–8.PubMedCrossRef
11.
Zurück zum Zitat Lee TC, Yang LC, Chen HJ. Effect of patient position and hypotensive anesthesia on inferior vena caval pressure. Spine. 1998;23:941–7.PubMedCrossRef Lee TC, Yang LC, Chen HJ. Effect of patient position and hypotensive anesthesia on inferior vena caval pressure. Spine. 1998;23:941–7.PubMedCrossRef
12.
Zurück zum Zitat Yokoyama M, Ueda W, Hirakawa M, Yamamoto H. Hemodynamic effect of the prone position during anesthesia. Acta Anaesthesiol Scand. 1991;35:741–4.PubMedCrossRef Yokoyama M, Ueda W, Hirakawa M, Yamamoto H. Hemodynamic effect of the prone position during anesthesia. Acta Anaesthesiol Scand. 1991;35:741–4.PubMedCrossRef
13.
Zurück zum Zitat Dharmavaram S, Jellish WS, Nockels RP, Shea J, Mehmood R, Ghanayem A, Kleinman B, Jacobs W. Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: an echocardiographic study. Spine. 2006;31:1388–93.PubMedCrossRef Dharmavaram S, Jellish WS, Nockels RP, Shea J, Mehmood R, Ghanayem A, Kleinman B, Jacobs W. Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: an echocardiographic study. Spine. 2006;31:1388–93.PubMedCrossRef
14.
Zurück zum Zitat Biais M, Bernard O, Ha JC, Degryse C, Sztark F. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Br J Anaesth. 2010;104:407–13.PubMedCrossRef Biais M, Bernard O, Ha JC, Degryse C, Sztark F. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Br J Anaesth. 2010;104:407–13.PubMedCrossRef
15.
Zurück zum Zitat Jacob M, Chappell D, Conzen P, Finsterer U, Rehm M. Blood volume is normal after preoperative overnight fasting. Acta Anesthesiol Scand. 2008;52:522–9.CrossRef Jacob M, Chappell D, Conzen P, Finsterer U, Rehm M. Blood volume is normal after preoperative overnight fasting. Acta Anesthesiol Scand. 2008;52:522–9.CrossRef
16.
Zurück zum Zitat Biais M, Nouette-Gaulain K, Cottenceau V, Revel P, Sztark F. Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth. 2008;101:761–8.PubMedCrossRef Biais M, Nouette-Gaulain K, Cottenceau V, Revel P, Sztark F. Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth. 2008;101:761–8.PubMedCrossRef
17.
Zurück zum Zitat Hofer CK, Senn A, Weibel L, Zollinger A. Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system. Crit Care. 2008;12:R82.PubMedCentralPubMedCrossRef Hofer CK, Senn A, Weibel L, Zollinger A. Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system. Crit Care. 2008;12:R82.PubMedCentralPubMedCrossRef
18.
Zurück zum Zitat Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Hénaine R, Lehot JJ. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg. 2009;108:513–7.PubMedCrossRef Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Hénaine R, Lehot JJ. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg. 2009;108:513–7.PubMedCrossRef
19.
Zurück zum Zitat Biais M, Nouette-Gaulain K, Roullet S, Quinart A, Revel P, Sztark F. A comparison of stroke volume variation measured by Vigileo/FloTrac system and aortic Doppler echocardiography. Anesth Analg. 2009;109:466–9.PubMedCrossRef Biais M, Nouette-Gaulain K, Roullet S, Quinart A, Revel P, Sztark F. A comparison of stroke volume variation measured by Vigileo/FloTrac system and aortic Doppler echocardiography. Anesth Analg. 2009;109:466–9.PubMedCrossRef
20.
Zurück zum Zitat Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth. 2011;25:904–16.PubMedCrossRef Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth. 2011;25:904–16.PubMedCrossRef
21.
Zurück zum Zitat Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg. 2001;92:984–9.PubMedCrossRef Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg. 2001;92:984–9.PubMedCrossRef
22.
Zurück zum Zitat Deflandre E, Bonhomme V, Hans P. Delta down compared with delta pulse pressure as an indicator of volaemia during intracranial surgery. Br J Anaesth. 2008;100:245–50.PubMedCrossRef Deflandre E, Bonhomme V, Hans P. Delta down compared with delta pulse pressure as an indicator of volaemia during intracranial surgery. Br J Anaesth. 2008;100:245–50.PubMedCrossRef
23.
Zurück zum Zitat Dawidson IJ, Willms CD, Sandor ZF, Coorpender LL, Reisch JS, Fry WJ. Ringer’s lactate with or without 3% dextran-60 as volume expanders during abdominal aortic surgery. Crit Care Med. 1991;19:36–42.PubMedCrossRef Dawidson IJ, Willms CD, Sandor ZF, Coorpender LL, Reisch JS, Fry WJ. Ringer’s lactate with or without 3% dextran-60 as volume expanders during abdominal aortic surgery. Crit Care Med. 1991;19:36–42.PubMedCrossRef
24.
Zurück zum Zitat Prien T, Backhaus N, Pelster F, Pircher W, Bünte H, Lawin P. Effect of intraoperative fluid administration and colloid osmotic pressure on the formation of intestinal edema during gastrointestinal surgery. J Clin Anesth. 1990;2:317–23.PubMedCrossRef Prien T, Backhaus N, Pelster F, Pircher W, Bünte H, Lawin P. Effect of intraoperative fluid administration and colloid osmotic pressure on the formation of intestinal edema during gastrointestinal surgery. J Clin Anesth. 1990;2:317–23.PubMedCrossRef
25.
Zurück zum Zitat Tommasino C, Picozzi V. Volume and electrolyte management. Best Pract Res Clin Anaesthesiol. 2007;21:497–516.PubMedCrossRef Tommasino C, Picozzi V. Volume and electrolyte management. Best Pract Res Clin Anaesthesiol. 2007;21:497–516.PubMedCrossRef
26.
Zurück zum Zitat Drummond JC, Patel PM, Cole DJ, Kelly PJ. The effect of the reduction of colloid oncotic pressure, with and without reduction of osmolality, on post-traumatic cerebral edema. Anesthesiology. 1998;88:993–1002.PubMedCrossRef Drummond JC, Patel PM, Cole DJ, Kelly PJ. The effect of the reduction of colloid oncotic pressure, with and without reduction of osmolality, on post-traumatic cerebral edema. Anesthesiology. 1998;88:993–1002.PubMedCrossRef
27.
Zurück zum Zitat Dunker S, Hsu HY, Sebag J, Sadun AA. Perioperative risk factors for posterior ischemic optic neuropathy. J Am Coll Surg. 2002;194:705–10.PubMedCrossRef Dunker S, Hsu HY, Sebag J, Sadun AA. Perioperative risk factors for posterior ischemic optic neuropathy. J Am Coll Surg. 2002;194:705–10.PubMedCrossRef
28.
Zurück zum Zitat Choi PT, Yip G, Quinonez LG, Cook DJ. Crystalloids vs. colloids in fluid resuscitation: a systematic review. Crit Care Med. 1999;27:200–10.PubMedCrossRef Choi PT, Yip G, Quinonez LG, Cook DJ. Crystalloids vs. colloids in fluid resuscitation: a systematic review. Crit Care Med. 1999;27:200–10.PubMedCrossRef
29.
Zurück zum Zitat Schierhout G, Roberts I. Fluid resuscitation with colloid or crystalloid solutions in critically ill patients: a systematic review of randomised trials. BMJ. 1998;316:961–4.PubMedCentralPubMedCrossRef Schierhout G, Roberts I. Fluid resuscitation with colloid or crystalloid solutions in critically ill patients: a systematic review of randomised trials. BMJ. 1998;316:961–4.PubMedCentralPubMedCrossRef
30.
Zurück zum Zitat Velanovich V. Crystalloid versus colloid fluid resuscitation: a meta-analysis of mortality. Surgery (St. Louis). 1989;105:65–71. Velanovich V. Crystalloid versus colloid fluid resuscitation: a meta-analysis of mortality. Surgery (St. Louis). 1989;105:65–71.
31.
Zurück zum Zitat Verheij J, van Lingen A, Beishuizen A, Christiaans HM, de Jong JR, Girbes AR, Wisselink W, Rauwerda JA, Huybregts MA, Groeneveld AB. Cardiac response is greater for colloid than saline fluid loading after cardiac or vascular surgery. Intensive Care Med. 2006;32:1030–8.PubMedCrossRef Verheij J, van Lingen A, Beishuizen A, Christiaans HM, de Jong JR, Girbes AR, Wisselink W, Rauwerda JA, Huybregts MA, Groeneveld AB. Cardiac response is greater for colloid than saline fluid loading after cardiac or vascular surgery. Intensive Care Med. 2006;32:1030–8.PubMedCrossRef
32.
Zurück zum Zitat Hartog CS, Bauer MB, Reinhart K. The efficacy and safety of colloid resuscitation in the critically ill. Anesth Analg. 2011;112:156–64.PubMedCrossRef Hartog CS, Bauer MB, Reinhart K. The efficacy and safety of colloid resuscitation in the critically ill. Anesth Analg. 2011;112:156–64.PubMedCrossRef
33.
Zurück zum Zitat Schramko AA, Suojaranta-Ylinen RT, Kuitunen AH, Raivio PM, Kukkonen SI, Niemi TT. Comparison of the effect of 6% hydroxyethyl starch and gelatine on cardiac and stroke volume index: a randomized, controlled trial after cardiac surgery. Perfusion. 2010;25:283–91.PubMedCrossRef Schramko AA, Suojaranta-Ylinen RT, Kuitunen AH, Raivio PM, Kukkonen SI, Niemi TT. Comparison of the effect of 6% hydroxyethyl starch and gelatine on cardiac and stroke volume index: a randomized, controlled trial after cardiac surgery. Perfusion. 2010;25:283–91.PubMedCrossRef
34.
Zurück zum Zitat Mythen MG, Webb AR. Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion during cardiac surgery. Arch Surg. 1995;130:423–9.PubMedCrossRef Mythen MG, Webb AR. Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion during cardiac surgery. Arch Surg. 1995;130:423–9.PubMedCrossRef
35.
Zurück zum Zitat Sinclair S, James S, Singer M. Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture; randomised controlled trial. BMJ. 1997;315:909–12.PubMedCentralPubMedCrossRef Sinclair S, James S, Singer M. Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture; randomised controlled trial. BMJ. 1997;315:909–12.PubMedCentralPubMedCrossRef
36.
Zurück zum Zitat Jungner M, Grände PO, Mattiasson G, Bentzer P. Effects on brain edema of crystalloid and albumin fluid resuscitation after brain trauma and hemorrhage in the rat. Anesthesiology. 2010;112:1194–203.PubMedCrossRef Jungner M, Grände PO, Mattiasson G, Bentzer P. Effects on brain edema of crystalloid and albumin fluid resuscitation after brain trauma and hemorrhage in the rat. Anesthesiology. 2010;112:1194–203.PubMedCrossRef
37.
Zurück zum Zitat Rusa R, Zornov MH. Fluid management during craniotomy. In: Cottrell JE, Young WL, editors. Cottrell and Young’s neuroanesthesia. 5th ed. Philadelphia: Mosby Elsevier; 2010. p. 155. Rusa R, Zornov MH. Fluid management during craniotomy. In: Cottrell JE, Young WL, editors. Cottrell and Young’s neuroanesthesia. 5th ed. Philadelphia: Mosby Elsevier; 2010. p. 155.
38.
Zurück zum Zitat Hartog CS, Reuter D, Loesche W, Hofmann M, Reinhart K. Influence of hydroxyethyl starch (HES) 130/0.4 on hemostasis as measured by viscoelastic device analysis: a systematic review. Intensive Care Med. 2011;37:1725–37.PubMedCrossRef Hartog CS, Reuter D, Loesche W, Hofmann M, Reinhart K. Influence of hydroxyethyl starch (HES) 130/0.4 on hemostasis as measured by viscoelastic device analysis: a systematic review. Intensive Care Med. 2011;37:1725–37.PubMedCrossRef
39.
Zurück zum Zitat Neff TA, Doelberg M, Jungheinrich C, Sauerland A, Spahn DR, Stocker R. Repetitive large-dose infusion of the novel hydroxyethyl starch 130/0.4 in patients with severe head injury. Anesth Analg. 2003;96:1453–9.PubMedCrossRef Neff TA, Doelberg M, Jungheinrich C, Sauerland A, Spahn DR, Stocker R. Repetitive large-dose infusion of the novel hydroxyethyl starch 130/0.4 in patients with severe head injury. Anesth Analg. 2003;96:1453–9.PubMedCrossRef
40.
Zurück zum Zitat Schramko AA, Suojaranta-Ylinen RT, Kuitunen AH, Kukkonen SI, Nimei TT. Rapidly degradable hydroxyethyl starch solutions impair blood coagulation after cardiac surgery: a prospective randomized trial. Anesth Analg. 2009;108:30–6.PubMedCrossRef Schramko AA, Suojaranta-Ylinen RT, Kuitunen AH, Kukkonen SI, Nimei TT. Rapidly degradable hydroxyethyl starch solutions impair blood coagulation after cardiac surgery: a prospective randomized trial. Anesth Analg. 2009;108:30–6.PubMedCrossRef
41.
Zurück zum Zitat Sudheer PS, Logan SW, Ateleanu B, Hall JE. Haemodynamic effects of the prone position: a comparison of propofol total intravenous and inhalation anaesthesia. Anaesthesia. 2006;61:138–41.PubMedCrossRef Sudheer PS, Logan SW, Ateleanu B, Hall JE. Haemodynamic effects of the prone position: a comparison of propofol total intravenous and inhalation anaesthesia. Anaesthesia. 2006;61:138–41.PubMedCrossRef
Metadaten
Titel
Stroke volume-directed administration of hydroxyethyl starch (HES 130/0.4) and Ringer’s acetate in prone position during neurosurgery: a randomized controlled trial
verfasst von
Ann-Christine Lindroos
Tomohisa Niiya
Tarja Randell
Tomi T. Niemi
Publikationsdatum
01.04.2014
Verlag
Springer Japan
Erschienen in
Journal of Anesthesia / Ausgabe 2/2014
Print ISSN: 0913-8668
Elektronische ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-013-1711-8

Weitere Artikel der Ausgabe 2/2014

Journal of Anesthesia 2/2014 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Häufigste Gründe für Brustschmerzen bei Kindern

06.05.2024 Pädiatrische Diagnostik Nachrichten

Akute Brustschmerzen sind ein Alarmsymptom par exellence, schließlich sind manche Auslöser lebensbedrohlich. Auch Kinder klagen oft über Schmerzen in der Brust. Ein Studienteam ist den Ursachen nachgegangen.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.