Skip to main content
Erschienen in: Journal of Digital Imaging 4/2020

19.02.2020 | Original Paper

Surface Point Cloud Ultrasound with Transcranial Doppler: Coregistration of Surface Point Cloud Ultrasound with Magnetic Resonance Angiography for Improved Reproducibility, Visualization, and Navigation in Transcranial Doppler Ultrasound

verfasst von: J. N. Stember, K. L. Terilli, E. Perez, M. Megjhani, C. A. Cooper, S. Jambawalikar, S. Park

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 4/2020

Einloggen, um Zugang zu erhalten

Abstract

Transcranial Doppler (TCD) ultrasound is a standard tool used in the setting of recent sub-arachnoid hemorrhage (SAH). By tracking velocity in the circle-of-Willis vessels, vasospasm can be detected as interval velocity increase. For this disease process, repeated TCD velocity measurements over many days is the basis for its usefulness. However, a key limitation to TCD is its user dependence, which is itself largely due to the fact that exact information about probe positioning is lost between subsequent scans. Surface point cloud ultrasound (SPC-US) was recently introduced as a general approach combining ultrasound and three-dimensional surface imaging of patient + probe. In the present proof-of-principle demonstration, we have applied SPC-US to TCD and co-registered the skin surface with that from MRA images to provide a roadmap of the vasculature in 3D space for better speed, accuracy, reproducibility, and potential semi-automation of TCD. Collating the acronyms, we call the combined approach SPC-US-TCD. TCD of the M1 was obtained while three-dimensional photographic images were obtained with the Structure Sensor camera. MRA imaging was also obtained. SPC-US-TCD and corresponding MRA 3D reconstruction images were co-registered in MeshMixer using the skin surfaces for alignment. A cylinder the width of the TCD probe was placed over the fused images and aligned with the direction and orientation of the TCD probe to demonstrate the acoustic beam. In the fused images, the acoustic beam intersects the right M1 segment of the middle cerebral artery (MCA). The angle of insonation is well demonstrated and measurable in various planes. Distance measurements made in Blender localized the TCD probe position based on three skin surface landmarks, and tabulated orientation based on three angles along the corresponding directions. SPC-US-TCD provides valuable information that is otherwise not present in TCD studies. By co-registering SPC-US-TCD data with that from cross sectional vessel imaging, precise probe location relative to external skin surface landmarks as well as 3D vessel location relative to TCD probe placement offers the potential to provide a roadmap that improves exam reproducibility, speed of acquisition, and accuracy. The goal of future work is to demonstrate this improvement statistically by application to multiple patients and scans.
Literatur
1.
Zurück zum Zitat Aaslid R, Markwalder T-M, Nornes H: Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. J Neurosurg. 57(6):769–774, 1982PubMedCrossRef Aaslid R, Markwalder T-M, Nornes H: Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. J Neurosurg. 57(6):769–774, 1982PubMedCrossRef
2.
Zurück zum Zitat Morris NA, Manning N, Marshall RS, Connolly ES, Claassen J, Agarwal S, Roh DJ, Schmidt JM, Park S: Transcranial Doppler waveforms during intra-aortic balloon pump Counterpulsation for vasospasm detection after subarachnoid hemorrhage. Neurosurgery. 83(3):416–421, 2018PubMedCrossRef Morris NA, Manning N, Marshall RS, Connolly ES, Claassen J, Agarwal S, Roh DJ, Schmidt JM, Park S: Transcranial Doppler waveforms during intra-aortic balloon pump Counterpulsation for vasospasm detection after subarachnoid hemorrhage. Neurosurgery. 83(3):416–421, 2018PubMedCrossRef
3.
Zurück zum Zitat Robba C, Goffi A, Geeraerts T, Cardim D, Via G, Czosnyka M, Park S, Sarwal A, Padayachy L, Rasulo F, Citerio G: Brain ultrasonography: Methodology, basic and advanced principles and clinical applications. A narrative review. Intensive Care Med. 45(7):913–927, 2019PubMedCrossRef Robba C, Goffi A, Geeraerts T, Cardim D, Via G, Czosnyka M, Park S, Sarwal A, Padayachy L, Rasulo F, Citerio G: Brain ultrasonography: Methodology, basic and advanced principles and clinical applications. A narrative review. Intensive Care Med. 45(7):913–927, 2019PubMedCrossRef
4.
Zurück zum Zitat Kirsch JD, Mathur M, Johnson MH, Gowthaman G, Scoutt LM: Advances in Transcranial Doppler US: Imaging ahead. RadioGraphics. 33(1):E1–E14, 2013PubMedCrossRef Kirsch JD, Mathur M, Johnson MH, Gowthaman G, Scoutt LM: Advances in Transcranial Doppler US: Imaging ahead. RadioGraphics. 33(1):E1–E14, 2013PubMedCrossRef
5.
Zurück zum Zitat Kramer DR, Winer JL, Pease BAM, Amar AP, Mack WJ: Cerebral vasospasm in traumatic brain injury. Neurol Res Int. 2013:1–7, 2013CrossRef Kramer DR, Winer JL, Pease BAM, Amar AP, Mack WJ: Cerebral vasospasm in traumatic brain injury. Neurol Res Int. 2013:1–7, 2013CrossRef
6.
Zurück zum Zitat Kassell NF, Sasaki T, Colohan AR, Nazar G: Cerebral vasospasm following aneurysmal subarachnoid hemorrhage. Stroke. 16(4):562–572, 1985PubMedCrossRef Kassell NF, Sasaki T, Colohan AR, Nazar G: Cerebral vasospasm following aneurysmal subarachnoid hemorrhage. Stroke. 16(4):562–572, 1985PubMedCrossRef
7.
Zurück zum Zitat Kreiter KT, Mayer SA, Howard G, Knappertz V, Ilodigwe D, Sloan MA, Macdonald RL: Sample size estimates for clinical trials of vasospasm in subarachnoid hemorrhage. Stroke. 40(7):2362–2367, 2009PubMedCrossRef Kreiter KT, Mayer SA, Howard G, Knappertz V, Ilodigwe D, Sloan MA, Macdonald RL: Sample size estimates for clinical trials of vasospasm in subarachnoid hemorrhage. Stroke. 40(7):2362–2367, 2009PubMedCrossRef
8.
Zurück zum Zitat Kassell NF, Torner JC, Haley EC et al.: The international cooperative Studyon the timing of aneurysm surgery. J Neurosurg. 73(1):18–36, 1990PubMedCrossRef Kassell NF, Torner JC, Haley EC et al.: The international cooperative Studyon the timing of aneurysm surgery. J Neurosurg. 73(1):18–36, 1990PubMedCrossRef
9.
Zurück zum Zitat Chadduck WM, Crabtree HM, Blankenship JB, Adametz J: Transcranial Doppler ultrasonography for the evaluation of shunt malfunction in pediatric patients. Childs Nerv Syst. 7(1):27–30, 1991PubMedCrossRef Chadduck WM, Crabtree HM, Blankenship JB, Adametz J: Transcranial Doppler ultrasonography for the evaluation of shunt malfunction in pediatric patients. Childs Nerv Syst. 7(1):27–30, 1991PubMedCrossRef
10.
Zurück zum Zitat Kral MC, Brown RT, Curé JK, Besenski N, Jackson SM, Abboud MR: Radiographic predictors of neurocognitive functioning in pediatric sickle cell disease. J Child Neurol. 21(1):37–44, 2006PubMedCrossRef Kral MC, Brown RT, Curé JK, Besenski N, Jackson SM, Abboud MR: Radiographic predictors of neurocognitive functioning in pediatric sickle cell disease. J Child Neurol. 21(1):37–44, 2006PubMedCrossRef
11.
Zurück zum Zitat Rasulo FA, De Peri E, Lavinio A: Transcranial Doppler ultrasonography in intensive care. Eur J Anaesthesiol. 25:167–173, 2008CrossRef Rasulo FA, De Peri E, Lavinio A: Transcranial Doppler ultrasonography in intensive care. Eur J Anaesthesiol. 25:167–173, 2008CrossRef
13.
Zurück zum Zitat Taylor KJ, Holland S: Doppler US. Part I. Basic principles, instrumentation, and pitfalls. Radiology. 174(2):297–307, 1990PubMedCrossRef Taylor KJ, Holland S: Doppler US. Part I. Basic principles, instrumentation, and pitfalls. Radiology. 174(2):297–307, 1990PubMedCrossRef
14.
Zurück zum Zitat Nelson T, Pretorius D: The Doppler signal: Where does it come from and what does it mean? Am J Roentgenol. 151(3):439–447, 1988CrossRef Nelson T, Pretorius D: The Doppler signal: Where does it come from and what does it mean? Am J Roentgenol. 151(3):439–447, 1988CrossRef
15.
Zurück zum Zitat Illig KA, Ouriel K, DeWeese JA, Holen J, Green RM: Measurement of carotid bifurcation pressure gradients using the Bernoulli principle. Cardiovasc Surg. 4(2):130–134, 1996PubMedCrossRef Illig KA, Ouriel K, DeWeese JA, Holen J, Green RM: Measurement of carotid bifurcation pressure gradients using the Bernoulli principle. Cardiovasc Surg. 4(2):130–134, 1996PubMedCrossRef
16.
Zurück zum Zitat Lupetin AR, Davis DA, Beckman I, Dash N: Transcranial Doppler sonography. Part 1. Principles, technique, and normal appearances. RadioGraphics. 15(1):179–191, 1995PubMedCrossRef Lupetin AR, Davis DA, Beckman I, Dash N: Transcranial Doppler sonography. Part 1. Principles, technique, and normal appearances. RadioGraphics. 15(1):179–191, 1995PubMedCrossRef
17.
Zurück zum Zitat Thomsen LL, Iversen HK: Experimental and biological variation of three-dimensional transcranial Doppler measurements. J Appl Physiol. 75(6):2805–2810, 1993PubMedCrossRef Thomsen LL, Iversen HK: Experimental and biological variation of three-dimensional transcranial Doppler measurements. J Appl Physiol. 75(6):2805–2810, 1993PubMedCrossRef
18.
Zurück zum Zitat Kaczynski J, Home R, Shields K, Walters M, Whiteley W, Wardlaw J, Newby DE: Reproducibility of Transcranial Doppler ultrasound in the middle cerebral artery. Cardiovasc Ultrasound. 16(1):15, 2018PubMedPubMedCentralCrossRef Kaczynski J, Home R, Shields K, Walters M, Whiteley W, Wardlaw J, Newby DE: Reproducibility of Transcranial Doppler ultrasound in the middle cerebral artery. Cardiovasc Ultrasound. 16(1):15, 2018PubMedPubMedCentralCrossRef
19.
Zurück zum Zitat Maeda H, Etani H, Handa N, Tagaya M, Oku N, Kim BH, Naka M, Kinoshita N, Nukada T, Fukunaga R: A validation study on the reproducibility of transcranial doppler velocimetry. Ultrasound Med Biol. 16(1):9–14, 1990PubMedCrossRef Maeda H, Etani H, Handa N, Tagaya M, Oku N, Kim BH, Naka M, Kinoshita N, Nukada T, Fukunaga R: A validation study on the reproducibility of transcranial doppler velocimetry. Ultrasound Med Biol. 16(1):9–14, 1990PubMedCrossRef
20.
Zurück zum Zitat Shen Q, Stuart J, Venkatesh B, Wallace J, Lipman J: Inter observer variability of the transcranial doppler ultrasound technique: Impact of lack of practice on the accuracy of measurement. J Clin Monit Comput. Kluwer Academic Publishers 15(3–4):179–184, 1999PubMedCrossRef Shen Q, Stuart J, Venkatesh B, Wallace J, Lipman J: Inter observer variability of the transcranial doppler ultrasound technique: Impact of lack of practice on the accuracy of measurement. J Clin Monit Comput. Kluwer Academic Publishers 15(3–4):179–184, 1999PubMedCrossRef
21.
Zurück zum Zitat Ceravolo MG, Minciotti P, Orlandini M, Provinciali L: Intra- and inter-observer variability of basal flow velocity and vascular reactivity measurements using transcranial Doppler sonography. Neurol Res. 14(2 Suppl):122–124, 1992PubMedCrossRef Ceravolo MG, Minciotti P, Orlandini M, Provinciali L: Intra- and inter-observer variability of basal flow velocity and vascular reactivity measurements using transcranial Doppler sonography. Neurol Res. 14(2 Suppl):122–124, 1992PubMedCrossRef
22.
Zurück zum Zitat Demolis P, Chalon S, Giudicelli JF: Repeatability of transcranial Doppler measurements of arterial blood flow velocities in healthy subjects. Clin Sci. 84(6):599–604, 1993PubMedCrossRef Demolis P, Chalon S, Giudicelli JF: Repeatability of transcranial Doppler measurements of arterial blood flow velocities in healthy subjects. Clin Sci. 84(6):599–604, 1993PubMedCrossRef
23.
Zurück zum Zitat Blanco P, Blaivas M: Applications of Transcranial color-coded Sonography in the emergency department. J Ultrasound Med. 36(6):1251–1266, 2017PubMedCrossRef Blanco P, Blaivas M: Applications of Transcranial color-coded Sonography in the emergency department. J Ultrasound Med. 36(6):1251–1266, 2017PubMedCrossRef
24.
Zurück zum Zitat Rigamonti A, Ackery A, Baker AJ: Transcranial Doppler monitoring in subarachnoid hemorrhage: A critical tool in critical care. Can J Anaesth. 55(2):112–123, 2008PubMedCrossRef Rigamonti A, Ackery A, Baker AJ: Transcranial Doppler monitoring in subarachnoid hemorrhage: A critical tool in critical care. Can J Anaesth. 55(2):112–123, 2008PubMedCrossRef
25.
Zurück zum Zitat Arkuszewski M, Swiat M, Hurst RW et al.: Vertebral and basilar arteries: Transcranial color-coded duplex ultrasonography versus conventional TCD in detection of narrowings. Neuroradiol J. Edizioni del Centauro 25(5):509–514, 2012CrossRef Arkuszewski M, Swiat M, Hurst RW et al.: Vertebral and basilar arteries: Transcranial color-coded duplex ultrasonography versus conventional TCD in detection of narrowings. Neuroradiol J. Edizioni del Centauro 25(5):509–514, 2012CrossRef
26.
Zurück zum Zitat Swiercz M, Swiat M, Pawlak M et al.: Narrowing of the middle cerebral artery: Artificial intelligence methods and comparison of transcranial color coded duplex sonography with conventional TCD. Ultrasound Med Biol. 36(1):17–28, 2010PubMedCrossRef Swiercz M, Swiat M, Pawlak M et al.: Narrowing of the middle cerebral artery: Artificial intelligence methods and comparison of transcranial color coded duplex sonography with conventional TCD. Ultrasound Med Biol. 36(1):17–28, 2010PubMedCrossRef
27.
Zurück zum Zitat Auer A, Felber S, Lutz W et al.: Transcranial Doppler sonography guided by magnetic resonance angiography for improved monitoring of intracranial arteries. J. Neuroimaging. Lippincott Williams and Wilkins:34–38, 1999 Auer A, Felber S, Lutz W et al.: Transcranial Doppler sonography guided by magnetic resonance angiography for improved monitoring of intracranial arteries. J. Neuroimaging. Lippincott Williams and Wilkins:34–38, 1999
28.
Zurück zum Zitat Kantelhardt SR, Greke C, Keric N, Vollmer F, Thiemann I, Giese A: Image Guidance for Transcranial Doppler Ultrasonography. Oper Neurosurg 68(suppl_2):ons257–ons266, 2011CrossRef Kantelhardt SR, Greke C, Keric N, Vollmer F, Thiemann I, Giese A: Image Guidance for Transcranial Doppler Ultrasonography. Oper Neurosurg 68(suppl_2):ons257–ons266, 2011CrossRef
29.
Zurück zum Zitat Greke C, Neulen A, Kantelhardt SR, Birkenmayer A, Vollmer FC, Thiemann I, Giese A: Image-guided Transcranial Doppler Sonography for monitoring of defined segments of intracranial arteries. J Neurosurg Anesthesiol. 25(1):55–61, 2013PubMedCrossRef Greke C, Neulen A, Kantelhardt SR, Birkenmayer A, Vollmer FC, Thiemann I, Giese A: Image-guided Transcranial Doppler Sonography for monitoring of defined segments of intracranial arteries. J Neurosurg Anesthesiol. 25(1):55–61, 2013PubMedCrossRef
30.
Zurück zum Zitat Stember JN: Three-dimensional surface point cloud ultrasound for better understanding and transmission of ultrasound scan information. J Digit Imaging. 31(6):904–911, 2018PubMedPubMedCentralCrossRef Stember JN: Three-dimensional surface point cloud ultrasound for better understanding and transmission of ultrasound scan information. J Digit Imaging. 31(6):904–911, 2018PubMedPubMedCentralCrossRef
31.
Zurück zum Zitat Pozniak MA, Zagzebski JA, Scanlan KA: Spectral and color Doppler artifacts. Radiographics. 12(1):35–44, 1992PubMedCrossRef Pozniak MA, Zagzebski JA, Scanlan KA: Spectral and color Doppler artifacts. Radiographics. 12(1):35–44, 1992PubMedCrossRef
Metadaten
Titel
Surface Point Cloud Ultrasound with Transcranial Doppler: Coregistration of Surface Point Cloud Ultrasound with Magnetic Resonance Angiography for Improved Reproducibility, Visualization, and Navigation in Transcranial Doppler Ultrasound
verfasst von
J. N. Stember
K. L. Terilli
E. Perez
M. Megjhani
C. A. Cooper
S. Jambawalikar
S. Park
Publikationsdatum
19.02.2020
Verlag
Springer International Publishing
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 4/2020
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-020-00328-y

Weitere Artikel der Ausgabe 4/2020

Journal of Digital Imaging 4/2020 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.