Tissue elasticity estimated by acoustic radiation force impulse quantification depends on the applied transducer force: an experimental study in kidney transplant patients

verfasst von: Trygve Syversveen, Karsten Midtvedt, Audun E. Berstad, Knut Brabrand, Erik H. Strøm, Andreas Abildgaard

Erschienen in: European Radiology | Ausgabe 10/2012

Einloggen, um Zugang zu erhalten

Abstract

Objectives

Acoustic radiation force impulse (ARFI) quantification estimates tissue elasticity by measuring shear-wave velocity (SWV) and has been applied to various organs. We evaluated the impact of variations in the transducer force applied to the skin on the SWV ultrasound measurements in kidney transplant cortex and ARFI’s ability to detect fibrosis in kidney transplants.

Methods

SWV measurements were performed in the cortex of 31 patients with kidney allografts referred for surveillance biopsies. A mechanical device held the transducer and applied forces were equal to a compression weight of 22, 275, 490, 975, 2,040 and 2,990 g.

Results

SWV group means were significantly different by repeat measures ANOVA [F(2.85,85.91) = 84.75, P < 0.0005 for 22, 275, 490, 975 and 2,040 g compression weight] and also by pairwise comparisons. Biopsy specimens were sufficient for histological evaluation in 29 of 31 patients. Twelve had grade 0, 11 grade 1, five grade 2 and one grade 3 fibrosis. One-way ANOVA showed no difference in SWV performed with any of the applied transducer forces between grafts with various degrees of fibrosis.

Conclusion

SWV measurements in kidney transplants are dependent on the applied transducer force and do not differ in grafts with different grades of fibrosis.

Key Points

Acoustic radiation force impulses (ARFI) can quantify tissue elasticity during ultrasound examinations.
Elasticity estimated by ARFI in kidney transplants depends on applied transducer force.
ARFI quantification cannot detect renal allograft fibrosis.
ARFI elasticity estimates may in general vary with applied transducer force.
Literatur
1.
Zurück zum Zitat Lupsor M, Badea R, Stefanescu H et al (2009) Performance of a new elastographic method (ARFI technology) compared to unidimensional transient elastography in the noninvasive assessment of chronic hepatitis C. Preliminary results. J Gastrointestin Liver Dis 18:303–310PubMed Lupsor M, Badea R, Stefanescu H et al (2009) Performance of a new elastographic method (ARFI technology) compared to unidimensional transient elastography in the noninvasive assessment of chronic hepatitis C. Preliminary results. J Gastrointestin Liver Dis 18:303–310PubMed
2.
Zurück zum Zitat Palmeri ML, Wang MH, Dahl JJ, Frinkley KD, Nightingale KR (2008) Quantifying hepatic shear modulus in vivo using acoustic radiation force. Ultrasound Med Biol 34:546–558PubMedCrossRef Palmeri ML, Wang MH, Dahl JJ, Frinkley KD, Nightingale KR (2008) Quantifying hepatic shear modulus in vivo using acoustic radiation force. Ultrasound Med Biol 34:546–558PubMedCrossRef
3.
Zurück zum Zitat Boursier J, Isselin G, Fouchard-Hubert I et al (2010) Acoustic radiation force impulse: a new ultrasonographic technology for the widespread noninvasive diagnosis of liver fibrosis. Eur J Gastroenterol Hepatol 22:1074–1084PubMedCrossRef Boursier J, Isselin G, Fouchard-Hubert I et al (2010) Acoustic radiation force impulse: a new ultrasonographic technology for the widespread noninvasive diagnosis of liver fibrosis. Eur J Gastroenterol Hepatol 22:1074–1084PubMedCrossRef
4.
Zurück zum Zitat Garra BS (2007) Imaging and estimation of tissue elasticity by ultrasound. Ultrasound Q 23:255–268PubMedCrossRef Garra BS (2007) Imaging and estimation of tissue elasticity by ultrasound. Ultrasound Q 23:255–268PubMedCrossRef
5.
Zurück zum Zitat Syversveen T, Brabrand K, Midtvedt K et al (2011) Assessment of renal allograft fibrosis by acoustic radiation force impulse quantification–a pilot study. Transpl Int 24:100–105PubMedCrossRef Syversveen T, Brabrand K, Midtvedt K et al (2011) Assessment of renal allograft fibrosis by acoustic radiation force impulse quantification–a pilot study. Transpl Int 24:100–105PubMedCrossRef
6.
Zurück zum Zitat Stock KF, Klein BS, Vo Cong MT et al (2010) ARFI-based tissue elasticity quantification in comparison to histology for the diagnosis of renal transplant fibrosis. Clin Hemorheol Microcirc 46:139–148PubMed Stock KF, Klein BS, Vo Cong MT et al (2010) ARFI-based tissue elasticity quantification in comparison to histology for the diagnosis of renal transplant fibrosis. Clin Hemorheol Microcirc 46:139–148PubMed
7.
Zurück zum Zitat Toshima T, Shirabe K, Takeishi K et al (2011) New method for assessing liver fibrosis based on acoustic radiation force impulse: a special reference to the difference between right and left liver. J Gastroenterol 46:705–711PubMedCrossRef Toshima T, Shirabe K, Takeishi K et al (2011) New method for assessing liver fibrosis based on acoustic radiation force impulse: a special reference to the difference between right and left liver. J Gastroenterol 46:705–711PubMedCrossRef
8.
Zurück zum Zitat Boman K, Olofsson M, Forsberg J, Bostrom SA (2009) Remote-controlled robotic arm for real-time echocardiography: the diagnostic future for patients in rural areas? Telemed J E Health 15:142–147PubMedCrossRef Boman K, Olofsson M, Forsberg J, Bostrom SA (2009) Remote-controlled robotic arm for real-time echocardiography: the diagnostic future for patients in rural areas? Telemed J E Health 15:142–147PubMedCrossRef
9.
Zurück zum Zitat Salcudean S, Bell G, Bachmann S, Zhu W, Abolmaesumi P, Lawrence P (1999) Robot-assisted diagnostic ultrasound − design and feasibility experiments. In: Taylor C, Colchester A (eds) Medical image computing and computer-assisted intervention (lecture notes in computer science). Springer, Berlin, pp 1062–1071 Salcudean S, Bell G, Bachmann S, Zhu W, Abolmaesumi P, Lawrence P (1999) Robot-assisted diagnostic ultrasound − design and feasibility experiments. In: Taylor C, Colchester A (eds) Medical image computing and computer-assisted intervention (lecture notes in computer science). Springer, Berlin, pp 1062–1071
10.
Zurück zum Zitat Goldberg RP, Dumitru M, Taylor RH, Stoianovici D (2001) A modular robotic system for ultrasound image aquisition. In: Niessen W, Viergraver M (eds) Lecture notes in computer science, vol 2208. Springer-Verlag, Berlin, pp 1430–1432 Goldberg RP, Dumitru M, Taylor RH, Stoianovici D (2001) A modular robotic system for ultrasound image aquisition. In: Niessen W, Viergraver M (eds) Lecture notes in computer science, vol 2208. Springer-Verlag, Berlin, pp 1430–1432
11.
Zurück zum Zitat Tozaki M, Isobe S, Fukuma E (2011) Preliminary study of ultrasonographic tissue quantification of the breast using the acoustic radiation force impulse (ARFI) technology. Eur J Radiol 80:e182–e187PubMedCrossRef Tozaki M, Isobe S, Fukuma E (2011) Preliminary study of ultrasonographic tissue quantification of the breast using the acoustic radiation force impulse (ARFI) technology. Eur J Radiol 80:e182–e187PubMedCrossRef
12.
Zurück zum Zitat Racusen LC, Solez K, Colvin RB et al (1999) The Banff 97 working classification of renal allograft pathology. Kidney Int 55:713–723PubMedCrossRef Racusen LC, Solez K, Colvin RB et al (1999) The Banff 97 working classification of renal allograft pathology. Kidney Int 55:713–723PubMedCrossRef
13.
Zurück zum Zitat Wells PN, Liang HD (2011) Medical ultrasound: imaging of soft tissue strain and elasticity. J R Soc Interface 8:1521–1549PubMedCrossRef Wells PN, Liang HD (2011) Medical ultrasound: imaging of soft tissue strain and elasticity. J R Soc Interface 8:1521–1549PubMedCrossRef
14.
Zurück zum Zitat Arndt R, Schmidt S, Loddenkemper C et al (2010) Noninvasive evaluation of renal allograft fibrosis by transient elastography–a pilot study. Transpl Int 23:871–877PubMed Arndt R, Schmidt S, Loddenkemper C et al (2010) Noninvasive evaluation of renal allograft fibrosis by transient elastography–a pilot study. Transpl Int 23:871–877PubMed
15.
Zurück zum Zitat Nankivell BJ, Borrows RJ, Fung CL, O'Connell PJ, Allen RD, Chapman JR (2003) The natural history of chronic allograft nephropathy. N Engl J Med 349:2326–2333PubMedCrossRef Nankivell BJ, Borrows RJ, Fung CL, O'Connell PJ, Allen RD, Chapman JR (2003) The natural history of chronic allograft nephropathy. N Engl J Med 349:2326–2333PubMedCrossRef
16.
Zurück zum Zitat Friedrich-Rust M, Romenski O, Meyer G et al (2012) Acoustic radiation force impulse-imaging for the evaluation of the thyroid gland: a limited patient feasibility study. Ultrasonics 52:69–74PubMedCrossRef Friedrich-Rust M, Romenski O, Meyer G et al (2012) Acoustic radiation force impulse-imaging for the evaluation of the thyroid gland: a limited patient feasibility study. Ultrasonics 52:69–74PubMedCrossRef
17.
Zurück zum Zitat Meng W, Zhang G, Wu C, Wu G, Song Y, Lu Z (2011) Preliminary results of acoustic radiation force impulse (ARFI) ultrasound imaging of breast lesions. Ultrasound Med Biol 37:1436–1443PubMedCrossRef Meng W, Zhang G, Wu C, Wu G, Song Y, Lu Z (2011) Preliminary results of acoustic radiation force impulse (ARFI) ultrasound imaging of breast lesions. Ultrasound Med Biol 37:1436–1443PubMedCrossRef
Metadaten
Titel
Tissue elasticity estimated by acoustic radiation force impulse quantification depends on the applied transducer force: an experimental study in kidney transplant patients
verfasst von
Trygve Syversveen
Karsten Midtvedt
Audun E. Berstad
Knut Brabrand
Erik H. Strøm
Andreas Abildgaard
Publikationsdatum
01.10.2012
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 10/2012
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-012-2476-4

Weitere Artikel der Ausgabe 10/2012

European Radiology 10/2012 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.