Skip to main content
Erschienen in: Journal of Nuclear Cardiology 4/2016

01.08.2016 | Debate Article

Traditional gamma cameras are preferred

verfasst von: E. Gordon DePuey, MD

Erschienen in: Journal of Nuclear Cardiology | Ausgabe 4/2016

Einloggen, um Zugang zu erhalten

Abstract

Although the new solid-state dedicated cardiac cameras provide excellent spatial and energy resolution and allow for markedly reduced SPECT acquisition times and/or injected radiopharmaceutical activity, they have some distinct disadvantages compared to traditional sodium iodide SPECT cameras. They are expensive. Attenuation correction is not available. Cardio-focused collimation, advantageous to increase depth-dependent resolution and myocardial count density, accentuates diaphragmatic attenuation and scatter from subdiaphragmatic structures. Although supplemental prone imaging is therefore routinely advised, many patients cannot tolerate it. Moreover, very large patients cannot be accommodated in the solid-state camera gantries. Since data are acquired simultaneously with an arc of solid-state detectors around the chest, no temporally dependent “rotating” projection images are obtained. Therefore, patient motion can be neither detected nor corrected. In contrast, traditional sodium iodide SPECT cameras provide rotating projection images to allow technologists and physicians to detect and correct patient motion and to accurately detect the position of soft tissue attenuators and to anticipate associated artifacts. Very large patients are easily accommodated. Low-dose x-ray attenuation correction is widely available. Also, relatively inexpensive low-count density software is provided by many vendors, allowing shorter SPECT acquisition times and reduced injected activity approaching that achievable with solid-state cameras.
Literatur
1.
Zurück zum Zitat DePuey EG. New software methods to cope with reduced counting statistics: Shorter SPECT acquisitions and many more possibilities. J Nucl Cardiol 2009;16:335-8.CrossRefPubMed DePuey EG. New software methods to cope with reduced counting statistics: Shorter SPECT acquisitions and many more possibilities. J Nucl Cardiol 2009;16:335-8.CrossRefPubMed
2.
Zurück zum Zitat DePuey EG, Ata P, Wray R, Friedman M. Very low-activity stress/high-activity rest, single-day myocardial perfusion SPECT with a conventional sodium iodide camera and wide beam reconstruction processing. J Nucl Cardiol 2012;19:931-44.CrossRefPubMed DePuey EG, Ata P, Wray R, Friedman M. Very low-activity stress/high-activity rest, single-day myocardial perfusion SPECT with a conventional sodium iodide camera and wide beam reconstruction processing. J Nucl Cardiol 2012;19:931-44.CrossRefPubMed
3.
Zurück zum Zitat Cerqueira MD, Allman KC, Ficaro EP, Hansen CL, Nichols KJ, Thompson RC, et al. Recommendations for reducing radiation dose from radionuclide myocardial perfusion imaging. J Nucl Cardiol 2010;17:709-18.CrossRefPubMed Cerqueira MD, Allman KC, Ficaro EP, Hansen CL, Nichols KJ, Thompson RC, et al. Recommendations for reducing radiation dose from radionuclide myocardial perfusion imaging. J Nucl Cardiol 2010;17:709-18.CrossRefPubMed
4.
Zurück zum Zitat DePuey EG. Image artifacts. In: Iskandrian AE, Garcia EV, editors. Nuclear cardiac imaging. 5th ed. New York: Oxford University Press; 2016. p. 137-77. DePuey EG. Image artifacts. In: Iskandrian AE, Garcia EV, editors. Nuclear cardiac imaging. 5th ed. New York: Oxford University Press; 2016. p. 137-77.
5.
Zurück zum Zitat Agrawal V, DePuey EG. Myocardial perfusion SPECT horizontal motion artifact. J Nucl Cardiol 2014;21:1260-5.CrossRef Agrawal V, DePuey EG. Myocardial perfusion SPECT horizontal motion artifact. J Nucl Cardiol 2014;21:1260-5.CrossRef
6.
Zurück zum Zitat Esteves FP, Galt JR. SPECT attenuation correction. In: Iskandrian AE, Garcia EV, editors. Nuclear cardiac imaging. 5th ed. New York: Oxford University Press; 2016. p. 137-77. Esteves FP, Galt JR. SPECT attenuation correction. In: Iskandrian AE, Garcia EV, editors. Nuclear cardiac imaging. 5th ed. New York: Oxford University Press; 2016. p. 137-77.
7.
Zurück zum Zitat Corbett J, Meden J, Ficaro E. Clinical validation of attenuation corrected cardiac imaging with IQ-SPECT. J Nucl Med 2010;4:733. Corbett J, Meden J, Ficaro E. Clinical validation of attenuation corrected cardiac imaging with IQ-SPECT. J Nucl Med 2010;4:733.
8.
Zurück zum Zitat Armstrong I, Saint K, Tonge C, Arumugam P. Evaluation of general-purpose collimators against high-resolution collimators with resolution recovery with a view to reducing radiation dose in myocardial perfusion SPECT: A preliminary phantom study. J Nucl Cardiol 2016. doi:10.1007/s12350-015-0368-0.PubMed Armstrong I, Saint K, Tonge C, Arumugam P. Evaluation of general-purpose collimators against high-resolution collimators with resolution recovery with a view to reducing radiation dose in myocardial perfusion SPECT: A preliminary phantom study. J Nucl Cardiol 2016. doi:10.​1007/​s12350-015-0368-0.PubMed
Metadaten
Titel
Traditional gamma cameras are preferred
verfasst von
E. Gordon DePuey, MD
Publikationsdatum
01.08.2016
Verlag
Springer US
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 4/2016
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-016-0460-0

Weitere Artikel der Ausgabe 4/2016

Journal of Nuclear Cardiology 4/2016 Zur Ausgabe

„Jeder Fall von plötzlichem Tod muss obduziert werden!“

17.05.2024 Plötzlicher Herztod Nachrichten

Ein signifikanter Anteil der Fälle von plötzlichem Herztod ist genetisch bedingt. Um ihre Verwandten vor diesem Schicksal zu bewahren, sollten jüngere Personen, die plötzlich unerwartet versterben, ausnahmslos einer Autopsie unterzogen werden.

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Schlechtere Vorhofflimmern-Prognose bei kleinem linken Ventrikel

17.05.2024 Vorhofflimmern Nachrichten

Nicht nur ein vergrößerter, sondern auch ein kleiner linker Ventrikel ist bei Vorhofflimmern mit einer erhöhten Komplikationsrate assoziiert. Der Zusammenhang besteht nach Daten aus China unabhängig von anderen Risikofaktoren.

Semaglutid bei Herzinsuffizienz: Wie erklärt sich die Wirksamkeit?

17.05.2024 Herzinsuffizienz Nachrichten

Bei adipösen Patienten mit Herzinsuffizienz des HFpEF-Phänotyps ist Semaglutid von symptomatischem Nutzen. Resultiert dieser Benefit allein aus der Gewichtsreduktion oder auch aus spezifischen Effekten auf die Herzinsuffizienz-Pathogenese? Eine neue Analyse gibt Aufschluss.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.