Skip to main content
Erschienen in: Skeletal Radiology 11/2017

02.08.2017 | Scientific Article

Ultrasonographic changes after steroid injection in carpal tunnel syndrome

verfasst von: Yeon Soo Lee, Eunseok Choi

Erschienen in: Skeletal Radiology | Ausgabe 11/2017

Einloggen, um Zugang zu erhalten

Abstract

Objective

To determine the ultrasonographic changes after steroid injection in carpal tunnel syndrome (CTS) and to evaluate the diagnostic value of ultrasound in post-treatment examination with clinical correlation.

Materials and methods

Twenty-seven wrists with idiopathic CTS after a single injection of 40 mg of prednisolone hydrochloride were prospectively studied using a high-resolution ultrasound. Axial images of the wrists were obtained at the level of the distal radius, pisiform and hamate prior to and 1, 4 and 8 weeks after steroid injection. The cross-sectional area (CSA, mm2) and flattening ratio (FR) of the median nerve were measured. The bowing of the flexor retinaculum (palmar displacement: PD, mm) and the transverse sliding distance of the median nerve (TSD, mm) during flexion-extension of the index finger were computed. Pre- and post-injection ultrasonographic findings were analyzed in relation to clinical parameters such as pain score.

Results

At all levels of the wrist, the CSA decreased significantly at 1 week after the injection, which continued to 8 weeks post-injection. The PD also diminished significantly 1 week after the injection. Furthermore, the TSD significantly increased from 1 week after injection, which lasted to the end of this study. The CSA, PD and TSD showed significant correlation with improvement of pain scores.

Conclusion

Ultrasound is useful in follow-up examinations of CTS. Significant ultrasound findings after steroid injections in CTS include decreased swelling of the median nerve, decreased bowing of the flexor retinaculum and increased mobility of the median nerve. All of them significantly correlate with clinical symptoms.
Literatur
1.
Zurück zum Zitat Beekman R, Visser LH. Sonography in the diagnosis of carpal tunnel syndrome: a critical review of the literature. Muscle Nerve. 2003;27(1):26–33.CrossRefPubMed Beekman R, Visser LH. Sonography in the diagnosis of carpal tunnel syndrome: a critical review of the literature. Muscle Nerve. 2003;27(1):26–33.CrossRefPubMed
2.
Zurück zum Zitat Nathan PA, Keniston RC, Meadows KD, Lockwood RS. Predictive value of nerve conduction measurements at the carpal tunnel. Muscle Nerve. 1993;16(12):1377–82.CrossRefPubMed Nathan PA, Keniston RC, Meadows KD, Lockwood RS. Predictive value of nerve conduction measurements at the carpal tunnel. Muscle Nerve. 1993;16(12):1377–82.CrossRefPubMed
3.
Zurück zum Zitat Padua L, LoMonaco M, Gregori B, Valente EM, Padua R, Tonali P. Neurophysiological classification and sensitivity in 500 carpal tunnel syndrome hands. Acta Neurol Scand. 1997;96(4):211–7.CrossRefPubMed Padua L, LoMonaco M, Gregori B, Valente EM, Padua R, Tonali P. Neurophysiological classification and sensitivity in 500 carpal tunnel syndrome hands. Acta Neurol Scand. 1997;96(4):211–7.CrossRefPubMed
4.
Zurück zum Zitat Duncan I, Sullivan P, Lomas F. Sonography in the diagnosis of carpal tunnel syndrome. AJR Am J Roentgenol. 1999;173(3):681–4.CrossRefPubMed Duncan I, Sullivan P, Lomas F. Sonography in the diagnosis of carpal tunnel syndrome. AJR Am J Roentgenol. 1999;173(3):681–4.CrossRefPubMed
5.
Zurück zum Zitat Buchberger W, Schön G, Strasser K, Jungwirth W. High-resolution ultrasonography of the carpal tunnel. J Ultrasound Med. 1991;10(10):531–7.CrossRefPubMed Buchberger W, Schön G, Strasser K, Jungwirth W. High-resolution ultrasonography of the carpal tunnel. J Ultrasound Med. 1991;10(10):531–7.CrossRefPubMed
6.
Zurück zum Zitat Wong SM, Griffith JF, Hui AC, Lo SK, Fu M, Wong KS. Carpal tunnel syndrome: diagnostic usefulness of sonography. Radiology. 2004;232(1):93–9.CrossRefPubMed Wong SM, Griffith JF, Hui AC, Lo SK, Fu M, Wong KS. Carpal tunnel syndrome: diagnostic usefulness of sonography. Radiology. 2004;232(1):93–9.CrossRefPubMed
7.
Zurück zum Zitat Junck AD, Escobedo EM, Lipa BM, et al. Reliability assessment of various sonographic techniques for evaluating carpal tunnel syndrome. J Ultrasound Med. 2015;34(11):2077–88.CrossRefPubMedPubMedCentral Junck AD, Escobedo EM, Lipa BM, et al. Reliability assessment of various sonographic techniques for evaluating carpal tunnel syndrome. J Ultrasound Med. 2015;34(11):2077–88.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Buchberger W, Judmaier W, Birbamer G, Lener M, Schmidauer C. Carpal tunnel syndrome: diagnosis with high-resolution sonography. AJR Am J Roentgenol. 1992;159(4):793–8.CrossRefPubMed Buchberger W, Judmaier W, Birbamer G, Lener M, Schmidauer C. Carpal tunnel syndrome: diagnosis with high-resolution sonography. AJR Am J Roentgenol. 1992;159(4):793–8.CrossRefPubMed
9.
Zurück zum Zitat Roll SC, Evans KD, Li X, Freimer M, Sommerich CM. Screening for carpal tunnel syndrome using sonography. J Ultrasound Med. 2011;30(12):1657–67.CrossRefPubMedPubMedCentral Roll SC, Evans KD, Li X, Freimer M, Sommerich CM. Screening for carpal tunnel syndrome using sonography. J Ultrasound Med. 2011;30(12):1657–67.CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat McDonagh C, Alexander M, Kane D. The role of ultrasound in the diagnosis and management of carpal tunnel syndrome: a new paradigm. Rheumatology. 2015;54(1):9–19.CrossRefPubMed McDonagh C, Alexander M, Kane D. The role of ultrasound in the diagnosis and management of carpal tunnel syndrome: a new paradigm. Rheumatology. 2015;54(1):9–19.CrossRefPubMed
11.
Zurück zum Zitat Yurdakul OV, Mesci N, Çetinkaya Y, Geler KD. Diagnostic significance of ultrasonographic measurements and median-ulnar ratio in carpal tunnel syndrome: correlation with nerve conduction studies. J Clin Neurol. 2016;12(3):289–94.CrossRefPubMedPubMedCentral Yurdakul OV, Mesci N, Çetinkaya Y, Geler KD. Diagnostic significance of ultrasonographic measurements and median-ulnar ratio in carpal tunnel syndrome: correlation with nerve conduction studies. J Clin Neurol. 2016;12(3):289–94.CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Chen YT, Williams L, Zak MJ, Fredericson M. Review of ultrasonography in the diagnosis of carpal tunnel syndrome and a proposed scanning protocol. J Ultrasound Med. 2016;35(11):2311–24.CrossRefPubMed Chen YT, Williams L, Zak MJ, Fredericson M. Review of ultrasonography in the diagnosis of carpal tunnel syndrome and a proposed scanning protocol. J Ultrasound Med. 2016;35(11):2311–24.CrossRefPubMed
13.
Zurück zum Zitat Nakamichi K, Tachibana S. Restricted motion of the median nerve in carpal tunnel syndrome. J Hand Surg Br. 1995;20(4):460–4.CrossRefPubMed Nakamichi K, Tachibana S. Restricted motion of the median nerve in carpal tunnel syndrome. J Hand Surg Br. 1995;20(4):460–4.CrossRefPubMed
14.
Zurück zum Zitat Yoshii Y, Ishii T, Tung WL, Sakai S, Amadio PC. Median nerve deformation and displacement in the carpal tunnel during finger motion. J Orthop Res. 2013;31(12):1876–80.CrossRefPubMed Yoshii Y, Ishii T, Tung WL, Sakai S, Amadio PC. Median nerve deformation and displacement in the carpal tunnel during finger motion. J Orthop Res. 2013;31(12):1876–80.CrossRefPubMed
15.
Zurück zum Zitat Ooi CC, Wong SK, Tan AB, et al. Diagnostic criteria of carpal tunnel syndrome using high-resolution ultrasonography: correlation with nerve conduction studies. Skelet Radiol. 2014;43(10):1387–94.CrossRef Ooi CC, Wong SK, Tan AB, et al. Diagnostic criteria of carpal tunnel syndrome using high-resolution ultrasonography: correlation with nerve conduction studies. Skelet Radiol. 2014;43(10):1387–94.CrossRef
16.
Zurück zum Zitat Kang HJ, Yoon JS. Effect of finger motion on transverse median nerve movement in the carpal tunnel. Muscle Nerve. 2016;54(4):738–42.CrossRefPubMed Kang HJ, Yoon JS. Effect of finger motion on transverse median nerve movement in the carpal tunnel. Muscle Nerve. 2016;54(4):738–42.CrossRefPubMed
17.
Zurück zum Zitat Hagebeuk EE, de Weerd AW. Clinical and electrophysiological follow-up after local steroid injection in the carpal tunnel syndrome. Clin Neurophysiol. 2004;115(6):1464–8.CrossRefPubMed Hagebeuk EE, de Weerd AW. Clinical and electrophysiological follow-up after local steroid injection in the carpal tunnel syndrome. Clin Neurophysiol. 2004;115(6):1464–8.CrossRefPubMed
18.
Zurück zum Zitat Smidt MH, Visser LH. Carpal tunnel syndrome: clinical and sonographic follow-up after surgery. Muscle Nerve. 2008;38(2):987–91.CrossRefPubMed Smidt MH, Visser LH. Carpal tunnel syndrome: clinical and sonographic follow-up after surgery. Muscle Nerve. 2008;38(2):987–91.CrossRefPubMed
19.
Zurück zum Zitat Abicalaf CA, de Barros N, Sernik RA, et al. Ultrasound evaluation of patients with carpal tunnel syndrome before and after endoscopic release of the transverse carpal ligament. Clin Radiol. 2007;62(9):891–4.CrossRefPubMed Abicalaf CA, de Barros N, Sernik RA, et al. Ultrasound evaluation of patients with carpal tunnel syndrome before and after endoscopic release of the transverse carpal ligament. Clin Radiol. 2007;62(9):891–4.CrossRefPubMed
20.
Zurück zum Zitat Inui A, Nishimoto H, Mifune Y, Kokubu T, Sakata R, Kurosaka M. Ultrasound measurement of median nerve cross-sectional area at the inlet and outlet of carpal tunnel after carpal tunnel release compared to electrodiagnostic findings. Arch Orthop Trauma Surg. 2016;136(9):1325–30.CrossRefPubMed Inui A, Nishimoto H, Mifune Y, Kokubu T, Sakata R, Kurosaka M. Ultrasound measurement of median nerve cross-sectional area at the inlet and outlet of carpal tunnel after carpal tunnel release compared to electrodiagnostic findings. Arch Orthop Trauma Surg. 2016;136(9):1325–30.CrossRefPubMed
21.
Zurück zum Zitat Kapuścińska K, Urbanik A. Efficacy of high frequency ultrasound in postoperative evaluation of carpal tunnel syndrome treatment. J Ultrason. 2016;16(64):16–24.CrossRefPubMedPubMedCentral Kapuścińska K, Urbanik A. Efficacy of high frequency ultrasound in postoperative evaluation of carpal tunnel syndrome treatment. J Ultrason. 2016;16(64):16–24.CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Jeong JS, Yoon JS, Kim SJ, et al. Usefulness of ultrasonography to predict response to injection therapy in carpal tunnel syndrome. Ann Rehabil Med. 2011;35(3):388–94.CrossRefPubMedPubMedCentral Jeong JS, Yoon JS, Kim SJ, et al. Usefulness of ultrasonography to predict response to injection therapy in carpal tunnel syndrome. Ann Rehabil Med. 2011;35(3):388–94.CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Cartwright MS, White DL, Demar S, et al. Median nerve changes following steroid injection for carpal tunnel syndrome. Muscle Nerve. 2011;44(1):25–9.CrossRefPubMedPubMedCentral Cartwright MS, White DL, Demar S, et al. Median nerve changes following steroid injection for carpal tunnel syndrome. Muscle Nerve. 2011;44(1):25–9.CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat Karadaş O, Omaç OK, Tok F, Ozgül A, Odabaşi Z. Effects of steroid with repetitive procaine HCl injection in the management of carpal tunnel syndrome: an ultrasonographic study. J Neurol. 2012;316(1-2):76–8. Karadaş O, Omaç OK, Tok F, Ozgül A, Odabaşi Z. Effects of steroid with repetitive procaine HCl injection in the management of carpal tunnel syndrome: an ultrasonographic study. J Neurol. 2012;316(1-2):76–8.
25.
Zurück zum Zitat Bayrak IK, Bayrak AO, Tilki HE, Nural MS, Sunter T. Ultrasonography in carpal tunnel syndrome: comparison with electrophysiological stage and motor unit number estimate. Muscle Nerve. 2007;35(3):344–8.CrossRefPubMed Bayrak IK, Bayrak AO, Tilki HE, Nural MS, Sunter T. Ultrasonography in carpal tunnel syndrome: comparison with electrophysiological stage and motor unit number estimate. Muscle Nerve. 2007;35(3):344–8.CrossRefPubMed
26.
Zurück zum Zitat Lu Y, Meng Z, Pan X, Qin L, Wang G. Value of high-frequency ultrasound in diagnosing carpal tunnel syndrome. Int J Clin Exp Med. 2015;8(12):22418–24.PubMedPubMedCentral Lu Y, Meng Z, Pan X, Qin L, Wang G. Value of high-frequency ultrasound in diagnosing carpal tunnel syndrome. Int J Clin Exp Med. 2015;8(12):22418–24.PubMedPubMedCentral
27.
Zurück zum Zitat Ajeena IM, Al-Saad RH, Al-Mudhafar A, Hadi NR, Al-Aridhy SH. Ultrasonic assessment of females with carpal tunnel syndrome proved by nerve conduction study. Neural Plast. 2013;2013:754564.CrossRefPubMedPubMedCentral Ajeena IM, Al-Saad RH, Al-Mudhafar A, Hadi NR, Al-Aridhy SH. Ultrasonic assessment of females with carpal tunnel syndrome proved by nerve conduction study. Neural Plast. 2013;2013:754564.CrossRefPubMedPubMedCentral
28.
Zurück zum Zitat Orman G, Ozben S, Huseyinoglu N, Duymus M, Orman KG. Ultrasound elastographic evaluation in the diagnosis of carpal tunnel syndrome: initial findings. Ultrasound Med Biol. 2013;39(7):1184–9.CrossRefPubMed Orman G, Ozben S, Huseyinoglu N, Duymus M, Orman KG. Ultrasound elastographic evaluation in the diagnosis of carpal tunnel syndrome: initial findings. Ultrasound Med Biol. 2013;39(7):1184–9.CrossRefPubMed
29.
Zurück zum Zitat Azami A, Maleki N, Anari H, Iranparvar Alamdari M, Kalantarhormozi M, Tavosi Z. The diagnostic value of ultrasound compared with nerve conduction velocity in carpal tunnel syndrome. Int J Rheum Dis. 2014;17(6):612–20.CrossRefPubMed Azami A, Maleki N, Anari H, Iranparvar Alamdari M, Kalantarhormozi M, Tavosi Z. The diagnostic value of ultrasound compared with nerve conduction velocity in carpal tunnel syndrome. Int J Rheum Dis. 2014;17(6):612–20.CrossRefPubMed
30.
Zurück zum Zitat Sarría L, Cabada T, Cozcolluela R, Martínez-Berganza T, García S. Carpal tunnel syndrome: usefulness of sonography. Eur Radiol. 2000;10(12):1920–5.CrossRefPubMed Sarría L, Cabada T, Cozcolluela R, Martínez-Berganza T, García S. Carpal tunnel syndrome: usefulness of sonography. Eur Radiol. 2000;10(12):1920–5.CrossRefPubMed
31.
Zurück zum Zitat Keleş I, Karagülle Kendi AT, Aydin G, Zöğ SG, Orkun S. Diagnostic precision of ultrasonography in patients with carpal tunnel syndrome. Am J Phys Med Rehabil. 2005;84(6):443–50.CrossRefPubMed Keleş I, Karagülle Kendi AT, Aydin G, Zöğ SG, Orkun S. Diagnostic precision of ultrasonography in patients with carpal tunnel syndrome. Am J Phys Med Rehabil. 2005;84(6):443–50.CrossRefPubMed
32.
Zurück zum Zitat Elsaman AM, Thabit MN, Radwan AR, Ohrndorf S. Idiopathic carpal tunnel syndrome: evaluation of the depth of the carpal tunnel by ultrasonography. Ultrasound Med Biol. 2015;41(11):2827–35.CrossRefPubMed Elsaman AM, Thabit MN, Radwan AR, Ohrndorf S. Idiopathic carpal tunnel syndrome: evaluation of the depth of the carpal tunnel by ultrasonography. Ultrasound Med Biol. 2015;41(11):2827–35.CrossRefPubMed
33.
Zurück zum Zitat Roll SC, Case-Smith J, Evans KD. Diagnostic accuracy of ultrasonography vs. electromyography in carpal tunnel syndrome: a systematic review of literature. Ultrasound Med Biol. 2011;37(10):1539–53.CrossRefPubMed Roll SC, Case-Smith J, Evans KD. Diagnostic accuracy of ultrasonography vs. electromyography in carpal tunnel syndrome: a systematic review of literature. Ultrasound Med Biol. 2011;37(10):1539–53.CrossRefPubMed
35.
Zurück zum Zitat Kim JK, Koh YD, Kim JO, Choi SW. Changes in clinical symptoms, functions, and the median nerve cross-sectional area at the carpal tunnel inlet after open carpal tunnel release. Clin Orthop Surg. 2016;8(3):298–302.CrossRefPubMedPubMedCentral Kim JK, Koh YD, Kim JO, Choi SW. Changes in clinical symptoms, functions, and the median nerve cross-sectional area at the carpal tunnel inlet after open carpal tunnel release. Clin Orthop Surg. 2016;8(3):298–302.CrossRefPubMedPubMedCentral
36.
Zurück zum Zitat Mondelli M, Filippou G, Aretini A, Frediani B, Reale F. Ultrasonography before and after surgery in carpal tunnel syndrome and relationship with clinical and electrophysiological findings. A new outcome predictor? Scand J Rheumatol. 2008;37(3):219–24.CrossRefPubMed Mondelli M, Filippou G, Aretini A, Frediani B, Reale F. Ultrasonography before and after surgery in carpal tunnel syndrome and relationship with clinical and electrophysiological findings. A new outcome predictor? Scand J Rheumatol. 2008;37(3):219–24.CrossRefPubMed
37.
Zurück zum Zitat Oh WT, Kang HJ, Koh IH, Jang JY, Choi YR. Morphologic change of nerve and symptom relief are similar after mini-incision and endoscopic carpal tunnel release: a randomized trial. BMC Musculoskelet Disord. 2017;18(1):65.CrossRefPubMedPubMedCentral Oh WT, Kang HJ, Koh IH, Jang JY, Choi YR. Morphologic change of nerve and symptom relief are similar after mini-incision and endoscopic carpal tunnel release: a randomized trial. BMC Musculoskelet Disord. 2017;18(1):65.CrossRefPubMedPubMedCentral
38.
Zurück zum Zitat Naranjo A, Ojeda S, Rúa-Figueroa I, Garcia-Duque O, Fernández-Palacios J, Carmona L. Limited value of ultrasound assessment in patients with poor outcome after carpal tunnel release surgery. Scand J Rheumatol. 2010;39(5):409–12.CrossRefPubMed Naranjo A, Ojeda S, Rúa-Figueroa I, Garcia-Duque O, Fernández-Palacios J, Carmona L. Limited value of ultrasound assessment in patients with poor outcome after carpal tunnel release surgery. Scand J Rheumatol. 2010;39(5):409–12.CrossRefPubMed
39.
Zurück zum Zitat Meys V, Thissen S, Rozeman S, Beekman R. Prognostic factors in carpal tunnel syndrome treated with a corticosteroid injection. Muscle Nerve. 2011;44(5):763–8.CrossRefPubMed Meys V, Thissen S, Rozeman S, Beekman R. Prognostic factors in carpal tunnel syndrome treated with a corticosteroid injection. Muscle Nerve. 2011;44(5):763–8.CrossRefPubMed
Metadaten
Titel
Ultrasonographic changes after steroid injection in carpal tunnel syndrome
verfasst von
Yeon Soo Lee
Eunseok Choi
Publikationsdatum
02.08.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Skeletal Radiology / Ausgabe 11/2017
Print ISSN: 0364-2348
Elektronische ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-017-2738-y

Weitere Artikel der Ausgabe 11/2017

Skeletal Radiology 11/2017 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.