Skip to main content
Erschienen in: European Radiology 5/2009

01.05.2009 | Musculoskeletal

Ultrasound-guided removal of foreign bodies: personal experience

verfasst von: Leonardo Callegari, Anna Leonardi, Amedeo Bini, Chiara Sabato, Paolo Nicotera, Emanuela Spano’, Davide Mariani, Eugenio A. Genovese, Carlo Fugazzola

Erschienen in: European Radiology | Ausgabe 5/2009

Einloggen, um Zugang zu erhalten

Abstract

Foreign bodies (FBs) retained in the soft tissues are a common reason for medical consultation, and usually consist of wooden or metal splinters or glass shards. Failure to remove foreign bodies is likely to give rise to acute or late complications, such as allergies, inflammation or infection, that may be severe. The surgical removal of an FB is invasive, costly and technically challenging. The procedure may fail in some cases and carries the risk of complications. Our study describes a technique for the ultrasound-guided removal of an FB, devised from our experience, and demonstrates its advantages over the standard surgical procedure. Sixty-two patients (43 males and 19 females aged from 9 to 65 years, median age 31 years) presented at our institution between October 2005 and June 2008 with suspected foreign bodies retained in the soft tissues of various body districts. Radiographic and/or ultrasound diagnosis was established by a radiologist expert in musculoskeletal sonography. The same radiologist helped by a nurse subsequently undertook the ultrasound-guided removal in the outpatient’s clinic according to the technique described in the paper. ATL 5000 and PHILIPS iu22 ultrasound systems were used with high-frequency linear-array probes, sterile material, local anaesthetic (lidocaine 2%), scapels and surgical forceps. Antibiotic prophylaxis with amoxicillin and clavulanic acid were prescribed to all patients for 7 days after the procedure. Ninety-five FBs (39 glass, 35 metal, 17 vegetable, 2 plastic, 2 stone) were successfully removed under ultrasound guidance in all patients and the procedure took between 15 and 30 min. No complications arose either during or after the procedure. Seventy-five skin incisions were made and the wounds closed with Steri-Strips in 73/75 cases, whereas skin sutures were used in 2/75 cases. No complications arose either during or after the procedure. Ultrasound-guided removal of an FB retained in the soft tissues is a good alternative to surgery as is its relatively straightforward, inexpensive, repeatable and carries a low risk of complications. In addition, failure to remove an FB does not preclude traditional surgical removal. The advantages of this real-time procedure and the use of small instruments minimize bleeding time and avoid injury to surrounding structures. Patient compliance is enhanced by the fact that the procedure has little or no aesthetic impact. These encouraging results suggest ultrasound-guided removal as a first-choice procedure for the extraction of foreign bodies.
Literatur
1.
Zurück zum Zitat Blankstein A, Cohen I, Heiman Z et al (2001) Ultrasonography as a diagnostic modality and therapeutic adjuvant in the management of soft tissue foreign bodies in the lower extremities. Isr Med Assoc J 3(6):411–413PubMed Blankstein A, Cohen I, Heiman Z et al (2001) Ultrasonography as a diagnostic modality and therapeutic adjuvant in the management of soft tissue foreign bodies in the lower extremities. Isr Med Assoc J 3(6):411–413PubMed
2.
Zurück zum Zitat Shiels WE 2nd, Babcock DS, Wilson JL, Burch RA (1990) Localization and guided removal of soft-tissue foreign bodies with sonography. AJR Am J Roentgenol 155(6):1277–1281PubMed Shiels WE 2nd, Babcock DS, Wilson JL, Burch RA (1990) Localization and guided removal of soft-tissue foreign bodies with sonography. AJR Am J Roentgenol 155(6):1277–1281PubMed
3.
Zurück zum Zitat Braham R, Said M, Jerbi Ommezine S, Gannouni A (2005) Foreign bodies in the soft tissues. The interest of sonography. Presse Med 34(3):256PubMedCrossRef Braham R, Said M, Jerbi Ommezine S, Gannouni A (2005) Foreign bodies in the soft tissues. The interest of sonography. Presse Med 34(3):256PubMedCrossRef
4.
Zurück zum Zitat Peterson JJ, Bancroft LW, Kransdorf MJ (2002) Wooden foreign bodies: imaging appearance. AJR Am J Roentgenol 178(3):557–562PubMed Peterson JJ, Bancroft LW, Kransdorf MJ (2002) Wooden foreign bodies: imaging appearance. AJR Am J Roentgenol 178(3):557–562PubMed
5.
Zurück zum Zitat Choudhari KA, Muthu T, Tan MH (2004) Progressive ulnar neuropathy caused by delayed migration of a foreign body. Scand J Plast Reconstr Surg Hand Surg 38(1):21–26CrossRef Choudhari KA, Muthu T, Tan MH (2004) Progressive ulnar neuropathy caused by delayed migration of a foreign body. Scand J Plast Reconstr Surg Hand Surg 38(1):21–26CrossRef
6.
Zurück zum Zitat Devgan A, Mudgal KC (2002) An unusual case of foreign body knee that spontaneously migrated inside and out of the joint: arthroscopic removal. J Hand Surg [Am] 27(2):350–354CrossRef Devgan A, Mudgal KC (2002) An unusual case of foreign body knee that spontaneously migrated inside and out of the joint: arthroscopic removal. J Hand Surg [Am] 27(2):350–354CrossRef
7.
Zurück zum Zitat Pang KP, Pang YT (1994) A rare case of a foreign body migration from the upper digestive tract to the subcutaneous neck. Unfallchirurg 97(7):372–374 Pang KP, Pang YT (1994) A rare case of a foreign body migration from the upper digestive tract to the subcutaneous neck. Unfallchirurg 97(7):372–374
8.
Zurück zum Zitat Gutierrez V, Radice F (1998) Late bullet migration into the knee joint. Neuroradiology 40(10):673–674CrossRef Gutierrez V, Radice F (1998) Late bullet migration into the knee joint. Neuroradiology 40(10):673–674CrossRef
9.
Zurück zum Zitat Ozsunar Y, Tali ET, Kilic K (2001) Unusual migration of a foreign body from the gut to a vertebral body. Br J Neurosurg 15(3):263–265CrossRef Ozsunar Y, Tali ET, Kilic K (2001) Unusual migration of a foreign body from the gut to a vertebral body. Br J Neurosurg 15(3):263–265CrossRef
10.
Zurück zum Zitat Combalia-Aleu A, Fuster-Obregon S (2003) Migration of a Kirschner wire from the sternum to the right ventricle. A case report. Eur J Cardiothorac Surg 24(2):301 Combalia-Aleu A, Fuster-Obregon S (2003) Migration of a Kirschner wire from the sternum to the right ventricle. A case report. Eur J Cardiothorac Surg 24(2):301
11.
Zurück zum Zitat Decker P, Hofler HR, Decker D et al (2003) Traumatic foreign body embolism from the basilic vein. Arthroscopy 19(3):E15 Decker P, Hofler HR, Decker D et al (2003) Traumatic foreign body embolism from the basilic vein. Arthroscopy 19(3):E15
12.
Zurück zum Zitat Gschwind CR (2002) The intravenous foreign body: a report of 2 cases. Ear Nose Throat J 81(10):730–732 Gschwind CR (2002) The intravenous foreign body: a report of 2 cases. Ear Nose Throat J 81(10):730–732
13.
Zurück zum Zitat Teltzrow T, Hallermann C, Muller S, Schwipper V (2006) Foreign body-induced angiosarcoma 60 years after a shell splinter injury. Mund Kiefer Gesichtschir 10(6):415–418PubMedCrossRef Teltzrow T, Hallermann C, Muller S, Schwipper V (2006) Foreign body-induced angiosarcoma 60 years after a shell splinter injury. Mund Kiefer Gesichtschir 10(6):415–418PubMedCrossRef
14.
Zurück zum Zitat Anderson MA, Newmeyer WL 3rd, Kilgore ES (1982) Diagnosis and treatment of retained foreign bodies in the hand. Am J Surg 144:63–67PubMedCrossRef Anderson MA, Newmeyer WL 3rd, Kilgore ES (1982) Diagnosis and treatment of retained foreign bodies in the hand. Am J Surg 144:63–67PubMedCrossRef
15.
Zurück zum Zitat Jacobson JA, Powel A, Craig JG et al (1998) Wooden foreign bodies in soft tissue: detection at US. Radiology 206:45–48PubMed Jacobson JA, Powel A, Craig JG et al (1998) Wooden foreign bodies in soft tissue: detection at US. Radiology 206:45–48PubMed
16.
Zurück zum Zitat Bray PW, Mahoney JL, Campbell JP (1995) Sensitivity and specificity of ultrasound in the diagnosis of foreign bodies in the hand. J Hand Surg [Am] 20(4):661–666CrossRef Bray PW, Mahoney JL, Campbell JP (1995) Sensitivity and specificity of ultrasound in the diagnosis of foreign bodies in the hand. J Hand Surg [Am] 20(4):661–666CrossRef
17.
Zurück zum Zitat Ng SY, Songra AK, Bradley PF (2003) A new approach using intraoperative ultrasound imaging for localization and removal of multiple foreign bodies in the neck. Int J Oral Maxillofac Surg 32(4):433–436PubMedCrossRef Ng SY, Songra AK, Bradley PF (2003) A new approach using intraoperative ultrasound imaging for localization and removal of multiple foreign bodies in the neck. Int J Oral Maxillofac Surg 32(4):433–436PubMedCrossRef
18.
Zurück zum Zitat Boyse TD, Fessell DP, Jacobson JA et al (2001) US of soft-tissue foreign bodies and associated complications with surgical correlation. Radiographics 21(5):1251–1256PubMed Boyse TD, Fessell DP, Jacobson JA et al (2001) US of soft-tissue foreign bodies and associated complications with surgical correlation. Radiographics 21(5):1251–1256PubMed
19.
Zurück zum Zitat Gibbs TS (2006) The use of sonography in the identification, localization and removal of soft tissue foreign bodies. J Diagnostic Medical Sonography 22(1):5–21CrossRef Gibbs TS (2006) The use of sonography in the identification, localization and removal of soft tissue foreign bodies. J Diagnostic Medical Sonography 22(1):5–21CrossRef
20.
Zurück zum Zitat Cardinal É, Chhnem RK, Germain Beauregard C (1998) Ultrasound-guided interventional procedures in the musculoskeletal system. Rad Clin N Am 36(3):597–604CrossRef Cardinal É, Chhnem RK, Germain Beauregard C (1998) Ultrasound-guided interventional procedures in the musculoskeletal system. Rad Clin N Am 36(3):597–604CrossRef
21.
Zurück zum Zitat Tubiana R, McCullough CJ, Masquelet AC (1996) Atlante delle vie chirurgiche d’accesso all’arto superiore. Antonio Delfino Editore, Rome, pp 1–2 Tubiana R, McCullough CJ, Masquelet AC (1996) Atlante delle vie chirurgiche d’accesso all’arto superiore. Antonio Delfino Editore, Rome, pp 1–2
Metadaten
Titel
Ultrasound-guided removal of foreign bodies: personal experience
verfasst von
Leonardo Callegari
Anna Leonardi
Amedeo Bini
Chiara Sabato
Paolo Nicotera
Emanuela Spano’
Davide Mariani
Eugenio A. Genovese
Carlo Fugazzola
Publikationsdatum
01.05.2009
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 5/2009
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-1266-5

Weitere Artikel der Ausgabe 5/2009

European Radiology 5/2009 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.