Skip to main content
Erschienen in: European Radiology 3/2009

01.03.2009 | Computer Tomography

Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases

verfasst von: Tobias Struffert, Gregor Richter, Tobias Engelhorn, Marc Doelken, Philipp Goelitz, Willi A. Kalender, Oliver Ganslandt, Arnd Doerfler

Erschienen in: European Radiology | Ausgabe 3/2009

Einloggen, um Zugang zu erhalten

Abstract

The aim of the study was to test the reliability of intracerebral haemorrhage (ICH) detection with C-arm-mounted flat-detector computed tomography (FD-CT) in the angio suite as compared to multislice CT (MSCT). In this study 44 patients with 45 ICH were included. All patients were investigated with MSCT and FD-CT during angiographic evaluation. As a control group we included 16 patients without ICH. In each haematoma we assessed volumetric data of the ICH and counted the numbers of ICH-positive slices. Using interobserver ratings, we additionally investigated the potential of FD-CT to serve as a diagnostic tool to detect ICH. In FD-CT three haematomas were not detected because of motion and beam-hardening artefacts in the region close to the skull base. The r value for the degree of interobserver agreement for the number of slices was 0.95 for MSCT and 0.94 for FD-CT. Measurements of the area and the calculated volume of the ICH showed high inter- and intraobserver agreement. Our results indicate that FD-CT is a helpful tool in the daily emergency management of ICH patients as detection of ICH was found to be nearly as reliable as in MSCT. Limitations of this technology are motion and beam-hardening artefacts that may mask small haematomas located in the posterior fossa or the skull base.
Literatur
1.
Zurück zum Zitat Sahni R, Weinberger J (2007) Management of intracerebral hemorrhage. Vasc Health Risk Manag 3(5):701–709PubMed Sahni R, Weinberger J (2007) Management of intracerebral hemorrhage. Vasc Health Risk Manag 3(5):701–709PubMed
2.
Zurück zum Zitat Hänggi D, Steiger HJ (2008) Spontaneous intracerebral haemorrhage in adults: a literature overview. Acta Neurochir 150:371–379CrossRef Hänggi D, Steiger HJ (2008) Spontaneous intracerebral haemorrhage in adults: a literature overview. Acta Neurochir 150:371–379CrossRef
3.
Zurück zum Zitat Brisman JL, Niimi Y, Song JK, Berenstein A (2005) Aneurysmal rupture during coiling: low incidence and good outcomes at a single large volume centre. Neurosurgery 57:1103–1109CrossRefPubMed Brisman JL, Niimi Y, Song JK, Berenstein A (2005) Aneurysmal rupture during coiling: low incidence and good outcomes at a single large volume centre. Neurosurgery 57:1103–1109CrossRefPubMed
4.
Zurück zum Zitat Carvi y Nievas M, Haas E, Höllerhage HG (2007) Severe intracranial bleedings during endovascular procedures: outcome of surgically treated patients. Neurol Res 29(1):81–90CrossRefPubMed Carvi y Nievas M, Haas E, Höllerhage HG (2007) Severe intracranial bleedings during endovascular procedures: outcome of surgically treated patients. Neurol Res 29(1):81–90CrossRefPubMed
5.
Zurück zum Zitat Kalender WA, Kyriakou Y (2007) Flat-detector computed tomography (FD-CT). Eur Radiol 17:2767–2779CrossRefPubMed Kalender WA, Kyriakou Y (2007) Flat-detector computed tomography (FD-CT). Eur Radiol 17:2767–2779CrossRefPubMed
6.
Zurück zum Zitat Schumacher M, Kutluk K, Ott D (1989) Digital rotational radiography in neuroradiology. Am J Neuroradiol 10:644–649PubMed Schumacher M, Kutluk K, Ott D (1989) Digital rotational radiography in neuroradiology. Am J Neuroradiol 10:644–649PubMed
7.
8.
Zurück zum Zitat Loose R, Wucherer M, Brunner T, Adamus R, Simmler R (2005) Visualization of 3D low contrast objects by CT cone-beam reconstruction of a rotational angiography with a dynamic solid body detector. Roefo S1:PO 160 Loose R, Wucherer M, Brunner T, Adamus R, Simmler R (2005) Visualization of 3D low contrast objects by CT cone-beam reconstruction of a rotational angiography with a dynamic solid body detector. Roefo S1:PO 160
9.
Zurück zum Zitat Heran NS, Song JK, Namba K, Smith W, Niimi Y, Berenstein A (2006) The utility of DynaCT in neuroendovascular procedures. Am J Neuroradiol 27:330–332PubMed Heran NS, Song JK, Namba K, Smith W, Niimi Y, Berenstein A (2006) The utility of DynaCT in neuroendovascular procedures. Am J Neuroradiol 27:330–332PubMed
10.
Zurück zum Zitat Arakawa H, Marks MP, Do HM, Bouley DM, Strobel N, Moore T, Fahrig R (2008) Experimental study of intracranial hematoma detection with flat panel detector C-arm CT. Am J Neuroradiol 29(4):766–772CrossRefPubMed Arakawa H, Marks MP, Do HM, Bouley DM, Strobel N, Moore T, Fahrig R (2008) Experimental study of intracranial hematoma detection with flat panel detector C-arm CT. Am J Neuroradiol 29(4):766–772CrossRefPubMed
11.
Zurück zum Zitat Kwak R, Kadoya S, Suzuke T (1983) Factors affecting the prognosis of thalamic hemorrhage. Stroke 14:493–500PubMed Kwak R, Kadoya S, Suzuke T (1983) Factors affecting the prognosis of thalamic hemorrhage. Stroke 14:493–500PubMed
12.
Zurück zum Zitat Richter G, Engelhorn T, Struffert T, Doelken M, Ganslandt O, Hornegger J, Kalender WA, Doerfler A (2007) Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms. Am J Neuroradiol 28(19):1902–1908CrossRefPubMed Richter G, Engelhorn T, Struffert T, Doelken M, Ganslandt O, Hornegger J, Kalender WA, Doerfler A (2007) Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms. Am J Neuroradiol 28(19):1902–1908CrossRefPubMed
13.
Zurück zum Zitat Engelhorn T, Rennert J, Richter G, Struffert T, Ganslandt O, Doerfler A (2007) Myelography using flat panel volumetric computed tomography: a comparative study in patients with lumbar spinal stenosis. Spine 32(18):E523–E527CrossRefPubMed Engelhorn T, Rennert J, Richter G, Struffert T, Ganslandt O, Doerfler A (2007) Myelography using flat panel volumetric computed tomography: a comparative study in patients with lumbar spinal stenosis. Spine 32(18):E523–E527CrossRefPubMed
14.
Zurück zum Zitat Doelken M, Struffert T, Richter G, Engelhorn T, Nimsky C, Ganslandt O, Hammen T, Doerfler A (2008) Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT. Neuroradiology 50(6):517–523CrossRefPubMed Doelken M, Struffert T, Richter G, Engelhorn T, Nimsky C, Ganslandt O, Hammen T, Doerfler A (2008) Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT. Neuroradiology 50(6):517–523CrossRefPubMed
Metadaten
Titel
Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases
verfasst von
Tobias Struffert
Gregor Richter
Tobias Engelhorn
Marc Doelken
Philipp Goelitz
Willi A. Kalender
Oliver Ganslandt
Arnd Doerfler
Publikationsdatum
01.03.2009
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 3/2009
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-1183-7

Weitere Artikel der Ausgabe 3/2009

European Radiology 3/2009 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.