Skip to main content
Erschienen in: Abdominal Radiology 6/2019

21.02.2019 | Pancreas

Weight-adapted ultra-low-dose pancreatic perfusion CT: radiation dose, image quality, and perfusion parameters

verfasst von: Ping Li, Wanling Deng, Huadan Xue, Kai Xu, Liang Zhu, Juan Li, Zhaoyong Sun, Zhengyu Jin

Erschienen in: Abdominal Radiology | Ausgabe 6/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

We evaluate the reliability and feasibility of weight-adapted ultra-low-dose pancreatic perfusion CT.

Methods

A total of 100 (47 men, 53 women) patients were enrolled prospectively and were assigned to five groups (A, B, C, D, and E) with different combination of tube voltage and tube current according to their body weight. Radiation dose parameters including volume CT dose index (CTDI) and dose-length product (DLP) were recorded. Image quality was evaluated both subjectively and objectively (noise, signal-to-noise ratio, contrast-to-noise ratio). Perfusion parameters including blood flow (BF), blood volume (BV), and permeability (PMB) were measured. The dose, image quality measurements, and perfusion parameters were compared between the five groups using one-way analysis of variance (ANOVA).

Results

Radiation dose reached 8.7 mSv in patients under 50 kg and was 18.9 mSv in patients above 80 kg. The mean subjective image quality score was above 4.45 on a 5-point scale with good agreement between two radiologists. Groups A–D had equivalent performance on objective image quality (P > 0.05), while Group E performed even better (P < 0.05). No significant differences emerged in comparison with perfusion parameters (BF, BV, PMB) of normal pancreas parenchyma between the five groups.

Conclusion

Weight-adapted ultra-low-dose pancreatic perfusion CT can effectively reduce radiation dose without prejudice to image quality, and the perfusion parameters of normal parenchyma are accurate and reliable.
Literatur
11.
Zurück zum Zitat Zhu L, Xue H, Sun Z, Li P, Qian T, Xing X, Li N, Zhao Y, Wu W, Jin Z (2017) Prospective comparison of biphasic contrast-enhanced CT, volume perfusion CT, and 3 Tesla MRI with diffusion-weighted imaging for insulinoma detection. Journal of magnetic resonance imaging : JMRI 46 (6):1648-1655. https://doi.org/10.1002/jmri.25709 CrossRefPubMed Zhu L, Xue H, Sun Z, Li P, Qian T, Xing X, Li N, Zhao Y, Wu W, Jin Z (2017) Prospective comparison of biphasic contrast-enhanced CT, volume perfusion CT, and 3 Tesla MRI with diffusion-weighted imaging for insulinoma detection. Journal of magnetic resonance imaging : JMRI 46 (6):1648-1655. https://​doi.​org/​10.​1002/​jmri.​25709 CrossRefPubMed
12.
Zurück zum Zitat Tsuji Y, Hamaguchi K, Watanabe Y, Okumura A, Isoda H, Yamamoto N, Kikuchi O, Yamamoto H, Matsueda K, Ueno K, Tada S, Togashi K, Yamamoto H, Chiba T (2010) Perfusion CT is superior to angiography in predicting pancreatic necrosis in patients with severe acute pancreatitis. Journal of gastroenterology 45 (11):1155-1162. https://doi.org/10.1007/s00535-010-0267-8 CrossRefPubMed Tsuji Y, Hamaguchi K, Watanabe Y, Okumura A, Isoda H, Yamamoto N, Kikuchi O, Yamamoto H, Matsueda K, Ueno K, Tada S, Togashi K, Yamamoto H, Chiba T (2010) Perfusion CT is superior to angiography in predicting pancreatic necrosis in patients with severe acute pancreatitis. Journal of gastroenterology 45 (11):1155-1162. https://​doi.​org/​10.​1007/​s00535-010-0267-8 CrossRefPubMed
14.
Zurück zum Zitat Tsuji Y, Yamamoto H, Yazumi S, Watanabe Y, Matsueda K, Yamamoto H, Chiba T (2007) Perfusion computerized tomography can predict pancreatic necrosis in early stages of severe acute pancreatitis. Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association 5 (12):1484-1492. https://doi.org/10.1016/j.cgh.2007.07.014 CrossRef Tsuji Y, Yamamoto H, Yazumi S, Watanabe Y, Matsueda K, Yamamoto H, Chiba T (2007) Perfusion computerized tomography can predict pancreatic necrosis in early stages of severe acute pancreatitis. Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association 5 (12):1484-1492. https://​doi.​org/​10.​1016/​j.​cgh.​2007.​07.​014 CrossRef
15.
Zurück zum Zitat Yadav AK, Sharma R, Kandasamy D, Pradhan RK, Garg PK, Bhalla AS, Gamanagatti S, Srivastava DN, Sahni P, Upadhyay AD (2016) Perfusion CT - Can it resolve the pancreatic carcinoma versus mass forming chronic pancreatitis conundrum? Pancreatology : official journal of the International Association of Pancreatology (IAP) [et al] 16 (6):979-987. https://doi.org/10.1016/j.pan.2016.08.011 Yadav AK, Sharma R, Kandasamy D, Pradhan RK, Garg PK, Bhalla AS, Gamanagatti S, Srivastava DN, Sahni P, Upadhyay AD (2016) Perfusion CT - Can it resolve the pancreatic carcinoma versus mass forming chronic pancreatitis conundrum? Pancreatology : official journal of the International Association of Pancreatology (IAP) [et al] 16 (6):979-987. https://​doi.​org/​10.​1016/​j.​pan.​2016.​08.​011
16.
Zurück zum Zitat Wang X, Henzler T, Gawlitza J, Diehl S, Wilhelm T, Schoenberg SO, Jin ZY, Xue HD, Smakic A (2016) Image quality of mean temporal arterial and mean temporal portal venous phase images calculated from low dose dynamic volume perfusion CT datasets in patients with hepatocellular carcinoma and pancreatic cancer. Eur J Radiol 85 (11):2104-2110. https://doi.org/10.1016/j.ejrad.2016.09.024 CrossRefPubMed Wang X, Henzler T, Gawlitza J, Diehl S, Wilhelm T, Schoenberg SO, Jin ZY, Xue HD, Smakic A (2016) Image quality of mean temporal arterial and mean temporal portal venous phase images calculated from low dose dynamic volume perfusion CT datasets in patients with hepatocellular carcinoma and pancreatic cancer. Eur J Radiol 85 (11):2104-2110. https://​doi.​org/​10.​1016/​j.​ejrad.​2016.​09.​024 CrossRefPubMed
17.
Zurück zum Zitat Gordic S, Morsbach F, Schmidt B, Allmendinger T, Flohr T, Husarik D, Baumueller S, Raupach R, Stolzmann P, Leschka S, Frauenfelder T, Alkadhi H (2014) Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping. Investigative radiology 49 (7):465-473. https://doi.org/10.1097/RLI.0000000000000037 CrossRefPubMed Gordic S, Morsbach F, Schmidt B, Allmendinger T, Flohr T, Husarik D, Baumueller S, Raupach R, Stolzmann P, Leschka S, Frauenfelder T, Alkadhi H (2014) Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping. Investigative radiology 49 (7):465-473. https://​doi.​org/​10.​1097/​RLI.​0000000000000037​ CrossRefPubMed
19.
Zurück zum Zitat Tesche C, De Cecco CN, Vliegenthart R, Albrecht MH, Varga-Szemes A, Duguay TM, Ebersberger U, Bayer RR, 2nd, Canstein C, Schmidt B, Allmendinger T, Litwin SE, Morris PB, Flohr TG, Hoffmann E, Schoepf UJ (2017) Accuracy and Radiation Dose Reduction Using Low-Voltage Computed Tomography Coronary Artery Calcium Scoring With Tin Filtration. Am J Cardiol 119 (4):675-680. https://doi.org/10.1016/j.amjcard.2016.10.051 CrossRefPubMed Tesche C, De Cecco CN, Vliegenthart R, Albrecht MH, Varga-Szemes A, Duguay TM, Ebersberger U, Bayer RR, 2nd, Canstein C, Schmidt B, Allmendinger T, Litwin SE, Morris PB, Flohr TG, Hoffmann E, Schoepf UJ (2017) Accuracy and Radiation Dose Reduction Using Low-Voltage Computed Tomography Coronary Artery Calcium Scoring With Tin Filtration. Am J Cardiol 119 (4):675-680. https://​doi.​org/​10.​1016/​j.​amjcard.​2016.​10.​051 CrossRefPubMed
21.
Zurück zum Zitat Apfaltrer G, Albrecht MH, Schoepf UJ, Duguay TM, De Cecco CN, Nance JW, De Santis D, Apfaltrer P, Eid MH, Eason CD, Thompson ZM, Bauer MJ, Varga-Szemes A, Jacobs BE, Sorantin E, Tesche C (2018) High-pitch low-voltage CT coronary artery calcium scoring with tin filtration: accuracy and radiation dose reduction. European radiology 28 (7):3097-3104. https://doi.org/10.1007/s00330-017-5249-2 CrossRefPubMed Apfaltrer G, Albrecht MH, Schoepf UJ, Duguay TM, De Cecco CN, Nance JW, De Santis D, Apfaltrer P, Eid MH, Eason CD, Thompson ZM, Bauer MJ, Varga-Szemes A, Jacobs BE, Sorantin E, Tesche C (2018) High-pitch low-voltage CT coronary artery calcium scoring with tin filtration: accuracy and radiation dose reduction. European radiology 28 (7):3097-3104. https://​doi.​org/​10.​1007/​s00330-017-5249-2 CrossRefPubMed
22.
Zurück zum Zitat Stacul F, van der Molen AJ, Reimer P, Webb JA, Thomsen HS, Morcos SK, Almen T, Aspelin P, Bellin MF, Clement O, Heinz-Peer G, Contrast Media Safety Committee of European Society of Urogenital R (2011) Contrast induced nephropathy: updated ESUR Contrast Media Safety Committee guidelines. European radiology 21 (12):2527-2541. https://doi.org/10.1007/s00330-011-2225-0 CrossRef Stacul F, van der Molen AJ, Reimer P, Webb JA, Thomsen HS, Morcos SK, Almen T, Aspelin P, Bellin MF, Clement O, Heinz-Peer G, Contrast Media Safety Committee of European Society of Urogenital R (2011) Contrast induced nephropathy: updated ESUR Contrast Media Safety Committee guidelines. European radiology 21 (12):2527-2541. https://​doi.​org/​10.​1007/​s00330-011-2225-0 CrossRef
29.
Zurück zum Zitat Miles KA, Lee TY, Goh V, Klotz E, Cuenod C, Bisdas S, Groves AM, Hayball MP, Alonzi R, Brunner T, Experimental Cancer Medicine Centre Imaging Network G (2012) Current status and guidelines for the assessment of tumour vascular support with dynamic contrast-enhanced computed tomography. European radiology 22 (7):1430-1441. https://doi.org/10.1007/s00330-012-2379-4 CrossRefPubMed Miles KA, Lee TY, Goh V, Klotz E, Cuenod C, Bisdas S, Groves AM, Hayball MP, Alonzi R, Brunner T, Experimental Cancer Medicine Centre Imaging Network G (2012) Current status and guidelines for the assessment of tumour vascular support with dynamic contrast-enhanced computed tomography. European radiology 22 (7):1430-1441. https://​doi.​org/​10.​1007/​s00330-012-2379-4 CrossRefPubMed
32.
38.
40.
Zurück zum Zitat Xue HD, Jin ZY, Liu W, Wang Y, Zhao WM (2006) [Perfusion characteristics of normal pancreas and insulinoma on multi-slice spiral CT]. Zhongguo yi xue ke xue yuan xue bao Acta Academiae Medicinae Sinicae 28 (1):68-70.PubMed Xue HD, Jin ZY, Liu W, Wang Y, Zhao WM (2006) [Perfusion characteristics of normal pancreas and insulinoma on multi-slice spiral CT]. Zhongguo yi xue ke xue yuan xue bao Acta Academiae Medicinae Sinicae 28 (1):68-70.PubMed
Metadaten
Titel
Weight-adapted ultra-low-dose pancreatic perfusion CT: radiation dose, image quality, and perfusion parameters
verfasst von
Ping Li
Wanling Deng
Huadan Xue
Kai Xu
Liang Zhu
Juan Li
Zhaoyong Sun
Zhengyu Jin
Publikationsdatum
21.02.2019
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 6/2019
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-019-01938-z

Weitere Artikel der Ausgabe 6/2019

Abdominal Radiology 6/2019 Zur Ausgabe

Classics in Abdominal Radiology

The “kissing sign” of liver and spleen

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.