Although other causes or the disease process itself has been proposed as causes for the hyperintensity, this retrospective comparison did not include a control group of patients with no CNS or a non-MS disease.
-
The authors specifically acknowledge that they could not control for or exclude the use of other contrast agents, including linear GBCAs. The fact that the baseline values (before the first gadobutrol dose) show elevated SI raises the possibility that there may have been either confounding contrast agent contamination prior to the first contrast-enhanced MRI that was used as the reference or other causes such as the previously discussed disease itself or associated iron depositions, which may play a critical role [3].
-
Patients were evaluated in three groups with different intervals of contrast administration. The different intervals between contrast-enhanced MRI may be indicative of different disease activity and/or treatment regimens requiring more frequent follow-up exams. This could introduce a bias if the disease activity itself is contributing to the hyperintensity. This might explain why the most prominent effect was in the group with the shortest period of contrast administration.
-
The scatter plot (Fig. 3) shows a correlation of 0.263, which is very low when compared to other similar studies, suggesting a potential unknown cause other than the administration of gadobutrol [4]. As common practice, a correlation of 0.50 or more is regarded as moderate and correlations of 0.75 or above as strong. Additionally, the number of administrations showed a statistically significant correlation to the increase in SI, but the total amount of contrast did not. This creates unanswered questions because the number of administrations and total amount of contrast are highly correlated.
-
Any visible changes in SI are not specifically mentioned and are difficult to appreciate even on the selected images provided in the paper, but only SI measurements are reported. Prior publications on MS have explored the importance of the region size and location on the quantitative measures, but this study does not specify any control to ensure the regions on the first and last scans were similar in size and location. The regions-of-interest may have been determined anatomically by consensus, rather than based on observable areas of signal increase.
Open Access 01.03.2016 | Contrast Media
What Evidence Is There That Gadobutrol Causes Increasing Signal Intensity within the Dentate Nucleus and Globus Pallidus on Unenhanced T1W MRI in Patients with RRMS?
Erschienen in: European Radiology | Ausgabe 3/2016