Skip to main content
Erschienen in: Journal of Anesthesia 3/2016

Open Access 14.01.2016 | Original Article

Blood transfusion, colloid therapy and the possible saving of albumin volumes during surgery: data analysis of the survey for certified hospitals of the Japanese Society of Anesthesiologists

verfasst von: Hideki Miyao, Safety Committee of Japanese Society of Anesthesiologists

Erschienen in: Journal of Anesthesia | Ausgabe 3/2016

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Abstract

Purpose

Third-generation hydroxyethyl starch (HES) 130/0.4 has a larger dose limitation (up to 50 mL/kg/day) than HES 70/0.5 (up to 1000 mL/day) which has been used in Japan for 40 years. The aim of this study was to survey the current intraoperative blood transfusion and volume therapy and to predict the possible reduction of intraoperative albumin consumption assuming further replacement by HES 130/0.4 using data obtained from a survey by the Japanese Society of Anesthesiologists (JSA), although HES130/0.4 was not launched in Japan during this survey period.

Methods

In a JSA survey conducted at JSA-certified hospitals, 12,856 patients with a certain amount of blood loss were analyzed for 1 month (April, 2012). The patients were divided into two groups—group A included patients aged ≥11 years and group B included patients aged <10 years. The possible lower volume of intraoperative albumin was calculated assuming that HES 130/0.4 was used up to a dose of 50 mL/kg.

Results

Blood loss (total 15,111 L; 15,057 L in group A and 54 L in group B) was treated with allogeneic transfusion (total 7970 L; 7893 L in group A and 77 L in group B) and auto-transfusion (total 1777 L; 1771 L in group A and 6 L in group B) in both groups (n = 11,670 and 119). Albumin (total 1391 L; 1376 L in group A and 15 L in group B), and HES 70/0.5 (total 7645 L; 7638 L in group A and 7 L in group B) were used in both groups (n = 10,850 and 116). Five percent and 4.4 % albumin (total 1189 L; 1180 L in group A and 9 L in group B) could be replaced by HES 130/0.4 if HES 130/0.4 had been used up to a dose of 50 mL/kg.

Conclusion

Blood loss (15,111 L) was replaced with allogeneic transfusion (53 %), auto-transfusion (12 %), albumin (9 %) and HES 70/0.5 (51 %) during surgery in April 2012. The predicted volume of 5 and 4.4 % albumin saved during this 1-month period if HES 130/0.4 had been used up to a dose of 50 mL/kg was 1189 L (86 % of actual amount used).

Introduction

Perioperative fluid therapy has shifted from the liberal use of crystalloids to goal-directed volume-restricted therapy using colloids for blood loss substitution [13]. In Japan, hydroxyethyl starch (HES) is the preferred colloid during surgery with HES 70/0.5 (Hespander®/Salinhes®) being the only HES specification available for the past 40 years. The maximum daily dosage of HES 70/0.5 has been limited to 1000 mL. When a higher volume of a colloid solution was indicated, albumin had to be used instead of HES 70/0.5 because new generation of HES had not been available in Japan, resulting in increased consumption of intraoperative albumin. Third-generation HES 130/0.4 (Voluven®) has a higher dose limitation (50 mL/kg/day) than HES 70/0.5 and was launched in Japan in October 2013.
In July 2012, 1 year prior to the launch of HES 130/0.4, the Japanese Society of Anesthesiologists (JSA) initiated a survey for usage of albumin and HES 70/0.5 within JSA-certified hospitals to document intraoperative infusion and transfusion therapy including colloid therapy (HES, albumin, and others). The aim of this study was to investigate the current status of blood transfusion and colloid therapy in operating theaters in Japan and to predict the possible reduction of intraoperative albumin volumes assuming that colloid volumes up to 50 mL/kg could be replaced by HES 130/0.4.

Methods

After approval by the ethics committee of the JSA, questionnaires prepared by the Safety Committee of the JSA were sent to 1234 JSA-certified hospitals in 2012. The survey consisted of two parts. In the first part, the representatives of anesthesiologists at individual hospitals were asked to complete a questionnaire on the use of 6 % HES 70/0.5 and albumin in the operating theater. In the second part, data describing transfusion and infusion status of surgical patients with intraoperative blood loss of either ≥500 mL for patients aged ≥11 years (group A) or with intraoperative blood loss ≥10 mL/kg for patients aged <10 years (group B) was derived from a 1-month database (April 2012).
The database from the second part of the JSA survey 2012 was the subject of the present study. The results of the first part will be presented soon on the official home page of JSA.
Unknown blood loss from certain procedures such as cardiac surgery with cardio-pulmonary bypass and abdominal aortic aneurysm surgery with intraoperative autologous blood salvage was not counted in the analysis of blood loss. Blood loss reported including amniotic fluid in Caesarian section or ascites in abdominal surgery was adopted to the blood loss as they were. The amount of transfusion was documented in mL, but when units were used, it was calculated as 140 mL per unit of red blood cells or 120 mL per unit of fresh frozen plasma in a standardized way. Platelet transfusion was excluded from further analysis as the documentation could not be clarified (units or mL) in many cases.
The algorithm to calculate the volume of 5 and 4.4 % albumin that could have been saved if 6 % HES 130/0.4 was used up to a dose of 50 mL/kg is given in Fig. 1. The intraoperative infusion volumes of 20 and 25 % albumin were excluded from the above calculations because these solutions were mostly used in the priming solution of cardiopulmonary bypass circuit.

Statistics

All variables were analyzed by descriptive statistical analysis.

Results

Seven hundred and seven of 1234 JSA-certified hospitals returned valid questionnaires for analysis and reported 134,500 surgical patients of whom 12,977 matched the methodology of this survey. Finally 11,670 patients were suitable for analysis for blood loss/transfusion, with 10,850 patients being suitable for infusion therapy in group A, and 119 patients being suitable for blood loss/transfusion and 116 for infusion therapy in group B (Fig. 2).
Table 1 shows demographic data in groups A and B. Table 2 shows blood loss, allogeneic transfusion, and auto-transfusion of patients in groups A and B. Total blood loss in group A (15,057 L) was treated with allogeneic transfusion (7893 L: 52 % of total blood loss) and auto-transfusion (1771 L:12 % of total blood loss), whereas total blood loss in group B (54,461 mL) was treated with allogeneic transfusion (77,016 mL: 141% of total blood loss) and auto-transfusion (6338 mL: 12 % of total blood loss) . It was evident that transfusion therapy dominates in pediatric patients.
Table 1
Demographic data in each group
 
Group A
Group B
Age (years)
 Valid cases
11,670 cases
119 cases
 Mean (median: min–max)
57 years (62: 11–104)
1.8 years (0.9: 0–10)
Body weight (kg)
 Valid cases
11, 446 cases
119 cases
 Mean (median: min–max)
60.2 kg (59.6: 30.1–138.7)
9.7 kg (7.7: 1.7–36.1)
min minimum, max maximum
Table 2
Blood loss, allogeneic transfusion, and auto-transfusion
 
Group A
Group B
Blood loss
 Valid cases
11,670 cases
119 cases
 Total amount
15,057 L
54,461 mL
 Mean (median: min–max)
1292 mL (911: 500–44,950)
458 mL(59) [300 (37): 17 (10)–2890 (389)]
Allogeneic transfusion
 Valid cases
5634 cases
104 cases
 Total amount
7893 L
77,016 mL
 Mean (median: min–max)
1401 mL (800: 1–48,300)
741 mL (367: 27–5958)
Auto-transfusion
 Valid cases
2624 cases
32 cases
 Total amount
1771 L
6338 mL
 Mean (median: min–max)
675 mL (500: 1–15,500)
198 mL (148: 4–1030)
Valid cases of blood loss indicates blood loss ≥500 mL in group A and 10 mL/kg in group B. Valid cases of allogeneic and auto transfusion indicates over 0 mL. Allogeneic transfusion included red blood cell concentrate and fresh frozen plasma but not platelet concentrate. Auto-transfusion included preoperative donated autologous transfusion, intraoperative hemodilution autologous transfusion, and intraoperative blood cell salvage transfusion, min minimum; max maximum, () in group B: values in mL/kg
Table 3 shows the total infusion volume including crystalloids, colloids, and predicted volume of albumin saved in groups A and B. Of 10,850 patients in group A, 1979 (18 %) were given albumin (5, 4.4, 20, or 25 %), and 8464 (78 %) were given HES 70/0.5. Of 8464 patients given HES 70/0.5, 1518 (18 %) were given >1000 mL HES 70/0.5 (this is the limitation volume specified in the package insert). One thousand one hundred eighty liters amount of 5 and 4.4 % albumin, which was 86 % of actually amount used (1366.2 L), could be replaced by HES 130/0.4 if HES 130/0.4 had been used up to a dose of 50 mL/kg. Of 116 patients in group B, 76 (66 %) were given albumin (5, 20, or 25 %), and 45 (39 %) were given HES 70/0.5. It became evident that the rate of albumin given was higher and the rate of HES given was lower in pediatric patients (group B) than those in group A. Nine thousand one hundred seventy four mL amout of 5 % albumin, which was 68 % of actually amount used (13,446 mL), could be replaced by HES 130/0.4 if HES 130/0.4 had been used up to a dose of 50 mL/kg.
Table 3
Total infusion volume, colloids volume, and predicted volume of albumin saved
 
Group A
Group B
Total infusion volume
 Valid cases
10,850 case
116 cases
 Total amount
32,283.3 L
87,431 mL
 Mean (median: min–max)
2975 mL (2500: 50–42,940)
754 mL (361: 17–6940)
5 % albumin
 Valid cases
1751 cases
53 cases
 Total amount
1280.0 L
13,446 mL
 Mean (median: min–max)
731 mL (500: 4–9500)
254 mL (110: 20–1650)
4.4 % albumin
 Valid cases
133 cases
0 case
 Total amount
86.2 L
 Mean (median: min–max)
648 mL (500: 100–3500)
20 % albumin
 Valid cases
15 cases
2 cases
 Total amount
2.5 L
16 mL
 Mean (median: min–max)
163 mL (100: 50–1000)
8 mL (8: 8–8)
25 % albumin
 Valid cases
80 cases
21 cases
 Total amount
7.0 L
1640 mL
 Mean (median: min–max)
88 mL (100: 30–250)
78 mL (80: 50–130)
HES70/0.5
 Valid cases
8464 cases
45 cases
 Total amount
7637.5 L
7131 mL
 Mean (median: min–max)
902 mL (,000: 10–12,500)
159 (12) mL [62 (8): 10 (1)–1000 (61)]
Other artificial colloids
 Valid cases
295 cases
0 case
 Total amount
195.5 L
 Mean (median: min–max)
663 mL (500: 50–2000)
Albumin saved by HES130/0.4
 Valid cases
1817 cases
52 cases
 Total amount
1180.1 L
9174 mL
 Mean (median: min–max)
650 mL (500: 4–3350)
176 mL (100: 20–905)
Total infusion volume included crystalloids and colloids. Other artificial colloid was only dextran. 20 and 25 % albumin were ineligible for analysis of "Albumin saved by HES 130/0.4"; min minimum, max maximum, () in group B: values in mL/kg
The calculation of the total predicted volume of albumin saved for 5 and 4.4 % albumin in groups A and B was 1189 L in April 2012. This predicted volume of albumin saved (1189 L) corresponds to 86.2% of actual amount of 4.4 and 5% albumin (1379 L) used during this period.
The JSA survey 2012 revealed that 15,111 L of blood loss were replaced with 7970 L of allogeneic transfusion, 1777 L of auto-transfusion, 1391 L of albumin, and 7645 L of HES 70/0.5 during surgery in April 2012. The predicted volume of 5 and 4.4 % albumin saved was 1189 L which was 86 % of actual amount used during this 1-month period if HES 130/0.4 had been used up to a dose of 50 mL/kg.

Discussion

The present survey is a unique study of a large database obtained from 707 JSA-certified hospitals to describe the current blood loss/transfusion and colloid therapy during surgery in Japan. The results of this survey may lead to a new strategy for intraoperative volume therapy.
HES has been used for perioperative volume replacement as a plasma substitute in operating theaters and intensive care units. We should consider two aspects for perioperative use of HES. First, HES can reduce intraoperative fluid loading. Recent intraoperative fluid management has changed from the liberal infusion strategy of extracellular fluid to a relatively goal-directed volume-restricted strategy using HES. Lowell et al. demonstrated that weight gain from fluid overloading during surgery correlated to high mortality rates [4]. Enhanced recovery after surgery consensus guideline [5, 6] specified “Intraoperative fluids should be balanced to avoid both hypo- and hypervolemia. Intraoperative goal directed fluid therapy should be considered on an individual basis”. In surgical use, HES (especially third-generation HES 130/0.4) demonstrated good outcomes for transfusion rate [7], mortality [8], and renal function [7]. HES still plays a major role in goal-directed intraoperative fluid therapy.
Second, HES 130/0.4 can reduce intraoperative albumin consumption because higher doses can be given compared to HES 70/0.5. Japan has not only been criticized for large albumin consumption, but also for high cost excessive perioperative albumin usage. The present study focused on this second issue.
The present study represents a large sample of 123,500 surgical patients with 10,966 patients (10,850 patients in group A and 116 patients in group B) being suitable for analysis.
Approximately 64 % of blood loss was replaced by allogeneic (52 %) and auto-transfusion (12 %). In group A, the auto-transfusion rate was 30 % of all transfusions, which was thought to be very high; however, in group B, 141 % of blood loss was replaced by allogeneic transfusion. There are two possible reasons. One reason is that a small volume of blood loss leads to hypovolemia and an unstable hemodynamic state in small children. In such situations, anesthesiologists tend to decide on early transfusion. Another reason is that the smaller the blood loss, the higher the difference between the actual blood loss and the measured blood loss because of drying gauze with the blood to be measured, and immeasurable blood absorbed by cover sheets or spilt on the floor. Anesthesiologists then tend to assess the volume status based on estimated blood loss rather than measured blood loss by the nurse.
The predicted volume of 5 and 4.4 % albumin saved was 1189 L in 1 month. This would amount to approximately 14,300 L over 1 year. Based on the statistics from the Ministry of Health, Labor and Welfare 2012 (http://​www.​mhlw.​go.​jp/​stf/​shingi/​2r9852000002hs9l​.​html), the total number of surgeries performed in 1648 diagnosis procedure combination (DPC) hospitals during a 6-month period was 2,045,932, which is 2.8 times higher than the source of the present study (123,500 in 1 month). Approximately 40,000 L (14,300 L × 2.8) of albumin would be saved in a year. The consumption of albumin in Japan in 2009 was 1460,000 L (http://​www.​mhlw.​go.​jp/​new-info/​kobetu/​iyaku/​kenketsugo/​2q/​pdf/​5-2.​pdf). As a result of this analysis, 2.7 % (40,000/1,460,000) of total albumin consumption could be saved in operating theaters.
The principle proof of this analysis was recently supported by a pilot study [8] as well by a study of surgical patients [9]. Blood loss and transfusion requirements in cardiac surgery were higher for albumin compared to HES 130/0.4 [10]. Albumin administration in cardiac surgery was associated with a dose-dependent risk of acute kidney injury, whereas 6 % HES 130/0.4 was not [11]. Albumin administration for critically ill patients did not improve mortality or morbidity even for hypoalbuminemia patients [12]. Based on these findings, third-generation HES 130/0.4 may become a major colloid for perioperative volume therapy instead of albumin. In cases of massive administration of HES 130/0.4 and also of albumin, however, dilutional coagulopathy should be monitored and treated appropriately with fresh frozen plasma and platelet concentrate.

Limitation of the study

1.
As anesthesiologists may not use up to the maximum dose of HES 130/0.4 in cases of bleeding during surgery, the calculation of the possible volume of saved albumin may be overestimated.
 
2.
The intraoperative infusion volume of 20 and 25 % albumin was excluded from the possible saving volume of albumin as it was mostly used in the priming solution of cardiopulmonary bypass circuit. This albumin, however, could also be replaced by HES 130/0.4 as the colloid for priming solution.
 

Conclusion

Based on data from the 2012 JSA survey, 15,111 L of blood loss were replaced with 7970 L of allogeneic transfusion, 1777 L of auto-transfusion, 1391 L of albumin, and 7645 L of HES 70/0.5 during surgery in April 2012. The predicted volume of 5 and 4.4 % albumin saved was 1189 L (86 % of actual amount used) during this 1-month period if HES 130/0.4 had been used up to a dose of 50 mL/kg.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Anästhesiologie

Kombi-Abonnement

Mit e.Med Anästhesiologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes AINS, den Premium-Inhalten der AINS-Fachzeitschriften, inklusive einer gedruckten AINS-Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Gan TJ, Soppitt A, Maroof M, El-Moalem H, Robertson KM, Moretti E, Dwane P, Glass PS. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology. 2002;97(4):820–6.CrossRefPubMed Gan TJ, Soppitt A, Maroof M, El-Moalem H, Robertson KM, Moretti E, Dwane P, Glass PS. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology. 2002;97(4):820–6.CrossRefPubMed
2.
Zurück zum Zitat Nisanevich V, Felsenstein I, Almogy G, Weissman C, Einav S, Matot I. Effect of intraoperative fluid management on outcome after intraabdominal surgery. Anesthesiology. 2005;103(1):25–32.CrossRefPubMed Nisanevich V, Felsenstein I, Almogy G, Weissman C, Einav S, Matot I. Effect of intraoperative fluid management on outcome after intraabdominal surgery. Anesthesiology. 2005;103(1):25–32.CrossRefPubMed
3.
Zurück zum Zitat Ghneim MH, Regner JL, Jupiter DC, Kang F, Bonner GL, Bready MS, Frazee R, Ciceri D, Davis ML. Goal directed fluid resuscitation decreases time for lactate clearance and facilitates early fascial closure in damage control surgery. Am J Surg. 2013;206(6):995–9 (discussion 999–1000).CrossRefPubMed Ghneim MH, Regner JL, Jupiter DC, Kang F, Bonner GL, Bready MS, Frazee R, Ciceri D, Davis ML. Goal directed fluid resuscitation decreases time for lactate clearance and facilitates early fascial closure in damage control surgery. Am J Surg. 2013;206(6):995–9 (discussion 999–1000).CrossRefPubMed
4.
Zurück zum Zitat Lowell J, Schifferdecker C, Driscoll D, Benotti P, Bistrian B. Postoperative fluid overload: not benign problem. Crit Care Med. 1990;18:728–33.CrossRefPubMed Lowell J, Schifferdecker C, Driscoll D, Benotti P, Bistrian B. Postoperative fluid overload: not benign problem. Crit Care Med. 1990;18:728–33.CrossRefPubMed
5.
Zurück zum Zitat Fearon KCH, Ljungqvist O, Von Meyenfeldt M, Revhaug A, Dejong CHC, Lassen K, Nygren J, Hause J, Soop M, Andersen J, Kehlet H. Enhanced recovery after surgery: a consensus review of clinical care for patients undergoing colonic resection. Clin Nutr. 2005;24(3):466–77.CrossRefPubMed Fearon KCH, Ljungqvist O, Von Meyenfeldt M, Revhaug A, Dejong CHC, Lassen K, Nygren J, Hause J, Soop M, Andersen J, Kehlet H. Enhanced recovery after surgery: a consensus review of clinical care for patients undergoing colonic resection. Clin Nutr. 2005;24(3):466–77.CrossRefPubMed
6.
Zurück zum Zitat Varadhan KK, Neal KR, Dejong CHC, Fearon KCH, Ljungqvist O, Lobo DN. The enhanced recovery after surgery (ERAS) pathway for patients undergoing major elective open colorectal surgery: a meta-analysis of randomized controlled trials. Clin Nutr. 2010;29(4):434–40.CrossRefPubMed Varadhan KK, Neal KR, Dejong CHC, Fearon KCH, Ljungqvist O, Lobo DN. The enhanced recovery after surgery (ERAS) pathway for patients undergoing major elective open colorectal surgery: a meta-analysis of randomized controlled trials. Clin Nutr. 2010;29(4):434–40.CrossRefPubMed
7.
Zurück zum Zitat James MF, Michell WL, Joubert IA, Nicol AJ, Navsaria PH, Gillespie RS. Resuscitation with hydroxyethyl starch improves renal function and lactate clearance in penetrating trauma in a randomized controlled study: the FIRST trial (fluids in resuscitation of severe trauma). Br J Anaesth. 2011;107(5):693–702.CrossRefPubMed James MF, Michell WL, Joubert IA, Nicol AJ, Navsaria PH, Gillespie RS. Resuscitation with hydroxyethyl starch improves renal function and lactate clearance in penetrating trauma in a randomized controlled study: the FIRST trial (fluids in resuscitation of severe trauma). Br J Anaesth. 2011;107(5):693–702.CrossRefPubMed
8.
Zurück zum Zitat Morioka N, Ozaki M, Yamakage M, Morimatsu H, Suzuki Y, Bepperling F, Miyao H, Namiki A, Morita K. The volume effect and safety of 6 % hydroxyethyl starch 130/0. 4 in patients undergoing major elective surgery : an uncontrolled, open-labeled, multi-center study. Open J Anesthesiol. 2013;3:326–37.CrossRef Morioka N, Ozaki M, Yamakage M, Morimatsu H, Suzuki Y, Bepperling F, Miyao H, Namiki A, Morita K. The volume effect and safety of 6 % hydroxyethyl starch 130/0. 4 in patients undergoing major elective surgery : an uncontrolled, open-labeled, multi-center study. Open J Anesthesiol. 2013;3:326–37.CrossRef
9.
Zurück zum Zitat Van Der Linden P, James M, Mythen M, Weiskopf RB. Safety of modern starches used during surgery. Anesth Analg. 2013;116(1):35–48.CrossRef Van Der Linden P, James M, Mythen M, Weiskopf RB. Safety of modern starches used during surgery. Anesth Analg. 2013;116(1):35–48.CrossRef
10.
11.
Zurück zum Zitat Frenette AJ, Bouchard J, Bernier P, Charbonneau A, Nguyen LT, Rioux JP, Troyanov S, Williamson DR. Albumin administration is associated with acute kidney injury in cardiac surgery : a propensity score analysis. Crit Care. 2014;18(6):602.CrossRefPubMedPubMedCentral Frenette AJ, Bouchard J, Bernier P, Charbonneau A, Nguyen LT, Rioux JP, Troyanov S, Williamson DR. Albumin administration is associated with acute kidney injury in cardiac surgery : a propensity score analysis. Crit Care. 2014;18(6):602.CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Roberts I, Blackhall K, Alderson P, Bunn F, Schierhout G. Human albumin solution for resuscitation and volume expansion in critically ill patients. Cochrane Database Syst Rev. 2011;11:CD001208.PubMed Roberts I, Blackhall K, Alderson P, Bunn F, Schierhout G. Human albumin solution for resuscitation and volume expansion in critically ill patients. Cochrane Database Syst Rev. 2011;11:CD001208.PubMed
Metadaten
Titel
Blood transfusion, colloid therapy and the possible saving of albumin volumes during surgery: data analysis of the survey for certified hospitals of the Japanese Society of Anesthesiologists
verfasst von
Hideki Miyao
Safety Committee of Japanese Society of Anesthesiologists
Publikationsdatum
14.01.2016
Verlag
Springer Japan
Erschienen in
Journal of Anesthesia / Ausgabe 3/2016
Print ISSN: 0913-8668
Elektronische ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-015-2136-3

Weitere Artikel der Ausgabe 3/2016

Journal of Anesthesia 3/2016 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.