Skip to main content
Erschienen in: European Radiology 10/2011

01.10.2011 | Cardiac

Commentary on: delayed enhancement imaging of myocardial viability: low-dose high-pitch CT versus MRI

verfasst von: Florian Wolf

Erschienen in: European Radiology | Ausgabe 10/2011

Einloggen, um Zugang zu erhalten

Excerpt

In 2005, Nikolaou et al. [1] published a paper in European Radiology about the assessment of myocardial perfusion and viability from routine contrast-enhanced 16-detector-row computed tomography. The authors reported promising results, however, concluded carefully: “… application of delayed enhancement techniques might be useful. … However, this procedure requires a second delayed CT scan, increasing the radiation exposure of the patient.”
Literatur
1.
Zurück zum Zitat Nikolaou K, Sanz J, Poon M et al (2005) Assessment of myocardial perfusion and viability from routine contrast-enhanced 16-detector-row computed tomography of the heart: preliminary results. Eur Radiol 15:864–871PubMedCrossRef Nikolaou K, Sanz J, Poon M et al (2005) Assessment of myocardial perfusion and viability from routine contrast-enhanced 16-detector-row computed tomography of the heart: preliminary results. Eur Radiol 15:864–871PubMedCrossRef
2.
Zurück zum Zitat Alkadhi H, Goetti R, Feuchtner G et al (2011) Delayed enhancement imaging of myocardial viability: low-dose high-pitch CT versus MRI. Eur Radiol. doi:10.1007/s00330-011-2149-8 Alkadhi H, Goetti R, Feuchtner G et al (2011) Delayed enhancement imaging of myocardial viability: low-dose high-pitch CT versus MRI. Eur Radiol. doi:10.​1007/​s00330-011-2149-8
3.
Zurück zum Zitat Lell M, Marwan M, Schepis T et al (2009) Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience. Eur Radiol 19:2576–2583PubMedCrossRef Lell M, Marwan M, Schepis T et al (2009) Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience. Eur Radiol 19:2576–2583PubMedCrossRef
4.
Zurück zum Zitat Leschka S, Stolzmann P, Desbiolles L et al (2009) Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience. Eur Radiol 19:2896–903, Epub 2009 Sep 16PubMedCrossRef Leschka S, Stolzmann P, Desbiolles L et al (2009) Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience. Eur Radiol 19:2896–903, Epub 2009 Sep 16PubMedCrossRef
5.
Zurück zum Zitat Mahnken AH, Bruners P, Muhlenbruch G et al (2007) Low tube voltage improves computed tomography imaging of delayed myocardial contrast enhancement in an experimental acute myocardial infarction model. Invest Radiol 42:123–129PubMedCrossRef Mahnken AH, Bruners P, Muhlenbruch G et al (2007) Low tube voltage improves computed tomography imaging of delayed myocardial contrast enhancement in an experimental acute myocardial infarction model. Invest Radiol 42:123–129PubMedCrossRef
6.
Zurück zum Zitat Mahnken AH, Bruners P, Friman O, Hennemuth A (2010) The culprit lesion and its consequences: combined visualization of the coronary arteries and delayed myocardial enhancement in dual-source CT: a pilot study. Eur Radiol 20:2834–2843PubMedCrossRef Mahnken AH, Bruners P, Friman O, Hennemuth A (2010) The culprit lesion and its consequences: combined visualization of the coronary arteries and delayed myocardial enhancement in dual-source CT: a pilot study. Eur Radiol 20:2834–2843PubMedCrossRef
7.
Zurück zum Zitat Kachenoura N, Lodato JA, Gaspar T et al (2009) Value of multidetector computed tomography evaluation of myocardial perfusion in the assessment of ischemic heart disease: comparison with nuclear perfusion imaging. Eur Radiol 19:1897–1905PubMedCrossRef Kachenoura N, Lodato JA, Gaspar T et al (2009) Value of multidetector computed tomography evaluation of myocardial perfusion in the assessment of ischemic heart disease: comparison with nuclear perfusion imaging. Eur Radiol 19:1897–1905PubMedCrossRef
8.
Zurück zum Zitat Kachenoura N, Veronesi F, Lodato JA et al (2010) Volumetric quantification of myocardial perfusion using analysis of multi-detector computed tomography 3D datasets: comparison with nuclear perfusion imaging. Eur Radiol 20:337–347PubMedCrossRef Kachenoura N, Veronesi F, Lodato JA et al (2010) Volumetric quantification of myocardial perfusion using analysis of multi-detector computed tomography 3D datasets: comparison with nuclear perfusion imaging. Eur Radiol 20:337–347PubMedCrossRef
9.
Zurück zum Zitat Schepis T, Achenbach S, Marwan M et al (2010) Prevalence of first-pass myocardial perfusion defects detected by contrast-enhanced dual-source CT in patients with non-ST segment elevation acute coronary syndromes. Eur Radiol 20:1607–1614PubMedCrossRef Schepis T, Achenbach S, Marwan M et al (2010) Prevalence of first-pass myocardial perfusion defects detected by contrast-enhanced dual-source CT in patients with non-ST segment elevation acute coronary syndromes. Eur Radiol 20:1607–1614PubMedCrossRef
10.
Zurück zum Zitat Groves AM, Goh V, Rajasekharan S et al (2008) CT coronary angiography: quantitative assessment of myocardial perfusion using test bolus data-initial experience. Eur Radiol 18:2155–2163PubMedCrossRef Groves AM, Goh V, Rajasekharan S et al (2008) CT coronary angiography: quantitative assessment of myocardial perfusion using test bolus data-initial experience. Eur Radiol 18:2155–2163PubMedCrossRef
11.
Zurück zum Zitat Cury RC, Nieman K, Shapiro MD et al (2008) Comprehensive assessment of myocardial perfusion defects, regional wall motion, and left ventricular function by using 64-section multidetector CT. Radiology 248:466–475PubMedCrossRef Cury RC, Nieman K, Shapiro MD et al (2008) Comprehensive assessment of myocardial perfusion defects, regional wall motion, and left ventricular function by using 64-section multidetector CT. Radiology 248:466–475PubMedCrossRef
12.
Zurück zum Zitat Blankstein R, Shturman LD, Rogers IS et al (2009) Adenosine-induced stress myocardial perfusion imaging using dual-source cardiac computed tomography. J Am Coll Cardiol 54:1072–1084PubMedCrossRef Blankstein R, Shturman LD, Rogers IS et al (2009) Adenosine-induced stress myocardial perfusion imaging using dual-source cardiac computed tomography. J Am Coll Cardiol 54:1072–1084PubMedCrossRef
13.
Zurück zum Zitat George RT, Arbab-Zadeh A, Miller JM et al (2009) Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: a pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia. Circ Cardiovasc Imaging 2:174–182PubMedCrossRef George RT, Arbab-Zadeh A, Miller JM et al (2009) Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: a pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia. Circ Cardiovasc Imaging 2:174–182PubMedCrossRef
14.
Zurück zum Zitat Rocha-Filho JA, Blankstein R, Shturman LD et al (2010) Incremental value of adenosine-induced stress myocardial perfusion imaging with dual-source CT at cardiac CT angiography. Radiology 254:410–419PubMedCrossRef Rocha-Filho JA, Blankstein R, Shturman LD et al (2010) Incremental value of adenosine-induced stress myocardial perfusion imaging with dual-source CT at cardiac CT angiography. Radiology 254:410–419PubMedCrossRef
15.
Zurück zum Zitat Ko SM, Choi JW, Song MG et al (2011) Myocardial perfusion imaging using adenosine-induced stress dual-energy computed tomography of the heart: comparison with cardiac magnetic resonance imaging and conventional coronary angiography. Eur Radiol 21:26–35PubMedCrossRef Ko SM, Choi JW, Song MG et al (2011) Myocardial perfusion imaging using adenosine-induced stress dual-energy computed tomography of the heart: comparison with cardiac magnetic resonance imaging and conventional coronary angiography. Eur Radiol 21:26–35PubMedCrossRef
Metadaten
Titel
Commentary on: delayed enhancement imaging of myocardial viability: low-dose high-pitch CT versus MRI
verfasst von
Florian Wolf
Publikationsdatum
01.10.2011
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 10/2011
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-011-2148-9

Weitere Artikel der Ausgabe 10/2011

European Radiology 10/2011 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.