Skip to main content
Erschienen in: Journal of Neural Transmission 5/2016

17.03.2016 | Translational Neurosciences - Original Article

Comparison of baroreflex sensitivity estimated from ECG R–R and inter-systolic intervals obtained by finger plethysmography and radial tonometry

verfasst von: Juliane Viehweg, Manja Reimann, Julia Gasch, Heinz Rüdiger, Tjalf Ziemssen

Erschienen in: Journal of Neural Transmission | Ausgabe 5/2016

Einloggen, um Zugang zu erhalten

Abstract

Spontaneous BRS estimates may considerable vary according to the technique of blood pressure and heart rate assessment. To optimise and standardise BRS estimation for clinical use we evaluated possible differences between spontaneous BRS indices estimated from either finger plethysmography or radial tonometry. Forty-five healthy volunteers underwent simultaneous recordings of electrocardiogram, finger plethysmography and radial tonometry in supine position and during 60° head-up tilt. BRS was computed by spectral analysis from either R–R time series and/or arterial pressure pulse. Radial tonometry generated higher mean BRS estimates than finger plethysmography. The difference decreased upon postural change from supine to upright. In the upright position, BRS estimates based on R–R interval proved to be generally lower compared to BRS indices estimated from arterial pressure pulse. The ratio of low-to-high-frequency power of inter-systolic interval and systolic blood pressure from tonometry was lower than that from plethysmography in supine and approximated in upright position. Spectral parameters of inter-systolic interval and R–R interval did not differ in supine but diverged in upright position. Changes of spectral parameters were most pronounced in R–R interval. Arterial pressure pulse is adequate for estimation of BRS under resting conditions but it may distort BRS estimates under physical load. We, therefore, recommend using an ECG signal for BRS estimation especially in non-stationary conditions.
Literatur
Zurück zum Zitat Bernardi L, Spallone V, Stevens M, et al (2011) Investigation methods for cardiac autonomic function in human research studies. Diabetes Metab Res Rev 27(7):654–664CrossRefPubMed Bernardi L, Spallone V, Stevens M, et al (2011) Investigation methods for cardiac autonomic function in human research studies. Diabetes Metab Res Rev 27(7):654–664CrossRefPubMed
Zurück zum Zitat Berntson GG, Bigger JT Jr, Eckberg DL et al (1997) Heart rate variability: origins, methods, and interpretive caveats. Psychophysiology 34(6):623–648CrossRefPubMed Berntson GG, Bigger JT Jr, Eckberg DL et al (1997) Heart rate variability: origins, methods, and interpretive caveats. Psychophysiology 34(6):623–648CrossRefPubMed
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310CrossRefPubMed Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310CrossRefPubMed
Zurück zum Zitat Constant I, Laude D, Murat I et al (1999) Pulse rate variability is not a surrogate for heart rate variability. Clin Sci (Lond) 97(4):391–397CrossRef Constant I, Laude D, Murat I et al (1999) Pulse rate variability is not a surrogate for heart rate variability. Clin Sci (Lond) 97(4):391–397CrossRef
Zurück zum Zitat Gasch J, Reimann M, Reichmann H et al (2011) Determination of baroreflex sensitivity during the modified Oxford maneuver by trigonometric regressive spectral analysis. PLoS One 6(3):e18061CrossRefPubMedPubMedCentral Gasch J, Reimann M, Reichmann H et al (2011) Determination of baroreflex sensitivity during the modified Oxford maneuver by trigonometric regressive spectral analysis. PLoS One 6(3):e18061CrossRefPubMedPubMedCentral
Zurück zum Zitat Giardino ND, Lehrer PM, Edelberg R (2002) Comparison of finger plethysmograph to ECG in the measurement of heart rate variability. Psychophysiology 39(2):246–253CrossRefPubMed Giardino ND, Lehrer PM, Edelberg R (2002) Comparison of finger plethysmograph to ECG in the measurement of heart rate variability. Psychophysiology 39(2):246–253CrossRefPubMed
Zurück zum Zitat Imholz BP, Wieling W, van Montfrans GA et al (1998) Fifteen years experience with finger arterial pressure monitoring: assessment of the technology. Cardiovasc Res 38(3):605–616CrossRefPubMed Imholz BP, Wieling W, van Montfrans GA et al (1998) Fifteen years experience with finger arterial pressure monitoring: assessment of the technology. Cardiovasc Res 38(3):605–616CrossRefPubMed
Zurück zum Zitat Kemmotsu O, Ueda M, Otsuka H et al (1991) Blood pressure measurement by arterial tonometry in controlled hypotension. Anesth Analg 73(1):54–58CrossRefPubMed Kemmotsu O, Ueda M, Otsuka H et al (1991) Blood pressure measurement by arterial tonometry in controlled hypotension. Anesth Analg 73(1):54–58CrossRefPubMed
Zurück zum Zitat La Rovere MT, Pinna GD, Hohnloser SH et al (2001) Baroreflex sensitivity and heart rate variability in the identification of patients at risk for life-threatening arrhythmias: implications for clinical trials. Circulation 103(16):2072–2077CrossRefPubMed La Rovere MT, Pinna GD, Hohnloser SH et al (2001) Baroreflex sensitivity and heart rate variability in the identification of patients at risk for life-threatening arrhythmias: implications for clinical trials. Circulation 103(16):2072–2077CrossRefPubMed
Zurück zum Zitat La Rovere MT, Pinna GD, Raczak G (2008) Baroreflex sensitivity: measurement and clinical implications. Ann Noninvasive Electrocardiol 13(2):191–207CrossRefPubMed La Rovere MT, Pinna GD, Raczak G (2008) Baroreflex sensitivity: measurement and clinical implications. Ann Noninvasive Electrocardiol 13(2):191–207CrossRefPubMed
Zurück zum Zitat La Rovere MT, Pinna GD, Maestri R et al (2009) Prognostic implications of baroreflex sensitivity in heart failure patients in the beta-blocking era. J Am Coll Cardiol 53(2):193–199CrossRefPubMed La Rovere MT, Pinna GD, Maestri R et al (2009) Prognostic implications of baroreflex sensitivity in heart failure patients in the beta-blocking era. J Am Coll Cardiol 53(2):193–199CrossRefPubMed
Zurück zum Zitat Laude D, Weise F, Girard A et al (1995) Spectral analysis of systolic blood pressure and heart rate oscillations related to respiration. Clin Exp Pharmacol Physiol 22(5):352–357CrossRefPubMed Laude D, Weise F, Girard A et al (1995) Spectral analysis of systolic blood pressure and heart rate oscillations related to respiration. Clin Exp Pharmacol Physiol 22(5):352–357CrossRefPubMed
Zurück zum Zitat Laude D, Elghozi JL, Girard A et al (2004) Comparison of various techniques used to estimate spontaneous baroreflex sensitivity (the EuroBaVar study). Am J Physiol Regul Integr Comp Physiol 286(1):R226–R231CrossRefPubMed Laude D, Elghozi JL, Girard A et al (2004) Comparison of various techniques used to estimate spontaneous baroreflex sensitivity (the EuroBaVar study). Am J Physiol Regul Integr Comp Physiol 286(1):R226–R231CrossRefPubMed
Zurück zum Zitat London GM (2008) Brachial arterial pressure to assess cardiovascular structural damage: an overview and lessons from clinical trials. J Nephrol 21(1):23–31PubMed London GM (2008) Brachial arterial pressure to assess cardiovascular structural damage: an overview and lessons from clinical trials. J Nephrol 21(1):23–31PubMed
Zurück zum Zitat Ludbrook J (1997) Comparing methods of measurements. Clin Exp Pharmacol Physiol 24(2):193–203CrossRefPubMed Ludbrook J (1997) Comparing methods of measurements. Clin Exp Pharmacol Physiol 24(2):193–203CrossRefPubMed
Zurück zum Zitat Ludbrook J (2002) Statistical techniques for comparing measurers and methods of measurement: a critical review. Clin Exp Pharmacol Physiol 29(7):527–536CrossRefPubMed Ludbrook J (2002) Statistical techniques for comparing measurers and methods of measurement: a critical review. Clin Exp Pharmacol Physiol 29(7):527–536CrossRefPubMed
Zurück zum Zitat Nelesen RA, Dimsdale JE (2002) Use of radial arterial tonometric continuous blood pressure measurement in cardiovascular reactivity studies. Blood Press Monit 7(5):259–263CrossRefPubMed Nelesen RA, Dimsdale JE (2002) Use of radial arterial tonometric continuous blood pressure measurement in cardiovascular reactivity studies. Blood Press Monit 7(5):259–263CrossRefPubMed
Zurück zum Zitat Omboni S, Parati G, Frattola A et al (1993) Spectral and sequence analysis of finger blood pressure variability. Comparison with analysis of intra-arterial recordings. Hypertension 22(1):26–33CrossRefPubMed Omboni S, Parati G, Frattola A et al (1993) Spectral and sequence analysis of finger blood pressure variability. Comparison with analysis of intra-arterial recordings. Hypertension 22(1):26–33CrossRefPubMed
Zurück zum Zitat Reyes del Paso GA, Gonzalez I, Hernandez JA (2004) Baroreceptor sensitivity and effectiveness varies differentially as a function of cognitive-attentional demands. Biol Psychol 67(3):385–395CrossRefPubMed Reyes del Paso GA, Gonzalez I, Hernandez JA (2004) Baroreceptor sensitivity and effectiveness varies differentially as a function of cognitive-attentional demands. Biol Psychol 67(3):385–395CrossRefPubMed
Zurück zum Zitat Reyes del Paso GA, Gonzalez MI, Hernandez JA (2010) Comparison of baroreceptor cardiac reflex sensitivity estimates from inter-systolic and ECG R–R intervals. Psychophysiol 47(6):1102–1108 Reyes del Paso GA, Gonzalez MI, Hernandez JA (2010) Comparison of baroreceptor cardiac reflex sensitivity estimates from inter-systolic and ECG R–R intervals. Psychophysiol 47(6):1102–1108
Zurück zum Zitat Rüdiger H, Klinghammer L, Scheuch K (1999) The trigonometric regressive spectral analysis–a method for mapping of beat-to-beat recorded cardiovascular parameters on to frequency domain in comparison with Fourier transformation. Comput Methods Programs Biomed 58(1):1–15CrossRefPubMed Rüdiger H, Klinghammer L, Scheuch K (1999) The trigonometric regressive spectral analysis–a method for mapping of beat-to-beat recorded cardiovascular parameters on to frequency domain in comparison with Fourier transformation. Comput Methods Programs Biomed 58(1):1–15CrossRefPubMed
Zurück zum Zitat Saul JP, Berger RD, Albrecht P et al (1991) Transfer function analysis of the circulation: unique insights into cardiovascular regulation. Am J Physiol 261(4 Pt 2):H1231–H1245PubMed Saul JP, Berger RD, Albrecht P et al (1991) Transfer function analysis of the circulation: unique insights into cardiovascular regulation. Am J Physiol 261(4 Pt 2):H1231–H1245PubMed
Zurück zum Zitat Watkins LL, Fainman C, Dimsdale J et al (1995) Assessment of baroreflex control from beat-to-beat blood pressure and heart rate changes: a validation study. Psychophysiology 32(4):411–414CrossRefPubMed Watkins LL, Fainman C, Dimsdale J et al (1995) Assessment of baroreflex control from beat-to-beat blood pressure and heart rate changes: a validation study. Psychophysiology 32(4):411–414CrossRefPubMed
Zurück zum Zitat Wesseling KH, Jansen JR, Settels JJ et al (1993) Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J Appl Physiol 74(5):2566–2573PubMed Wesseling KH, Jansen JR, Settels JJ et al (1993) Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J Appl Physiol 74(5):2566–2573PubMed
Zurück zum Zitat Westerhof BE, Gisolf J, Karemaker JM et al (2006) Time course analysis of baroreflex sensitivity during postural stress. Am J Physiol Heart Circ Physiol 291(6):H2864–H2874CrossRefPubMed Westerhof BE, Gisolf J, Karemaker JM et al (2006) Time course analysis of baroreflex sensitivity during postural stress. Am J Physiol Heart Circ Physiol 291(6):H2864–H2874CrossRefPubMed
Zurück zum Zitat Ziemssen T, Gasch J, Ruediger H (2008) Influence of ECG Sampling Frequency on Spectral Analysis of RR Intervals and Baroreflex Sensitivity Using the EUROBAVAR Data set. J Clin Monit Comput 22(2):159–168CrossRefPubMed Ziemssen T, Gasch J, Ruediger H (2008) Influence of ECG Sampling Frequency on Spectral Analysis of RR Intervals and Baroreflex Sensitivity Using the EUROBAVAR Data set. J Clin Monit Comput 22(2):159–168CrossRefPubMed
Zurück zum Zitat (1996) Heart rate variability: standards of measurement, physiological interpretation and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. Circ 93(5):1043–1065 (1996) Heart rate variability: standards of measurement, physiological interpretation and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. Circ 93(5):1043–1065
Metadaten
Titel
Comparison of baroreflex sensitivity estimated from ECG R–R and inter-systolic intervals obtained by finger plethysmography and radial tonometry
verfasst von
Juliane Viehweg
Manja Reimann
Julia Gasch
Heinz Rüdiger
Tjalf Ziemssen
Publikationsdatum
17.03.2016
Verlag
Springer Vienna
Erschienen in
Journal of Neural Transmission / Ausgabe 5/2016
Print ISSN: 0300-9564
Elektronische ISSN: 1435-1463
DOI
https://doi.org/10.1007/s00702-016-1535-4

Weitere Artikel der Ausgabe 5/2016

Journal of Neural Transmission 5/2016 Zur Ausgabe

Neurology and Preclinical Neurological Studies - Short communication

Nigral involvement in atypical parkinsonisms: evidence from a pilot study with ultra-high field MRI

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.