17.06.2021 | Original Research

Comparison of cutaneous facial temperature using infrared thermography to standard temperature measurement in the critical care setting

verfasst von: Peter Y. Chan, Andrew Tay, David Chen, Sara Vogrin, John McNeil, Ingrid Hopper

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 4/2022

Einloggen, um Zugang zu erhalten

Abstract

To assess the accuracy and precision of infrared cameras compared to traditional measures of temperature measurement in a temperature, humidity, and distance controlled intensive care unit (ICU) population. This was a prospective, observational methods comparison study in a single centre ICU in Metropolitan Melbourne, Australia. A convenience sample of 39 patients admitted to a single room equipped with two ceiling mounted thermal imaging cameras was assessed, comparing measured cutaneous facial temperature via thermal camera to clinical temperature standards. Uncorrected correlation of camera measurement to clinical standard in all cases was poor, with the maximum reported correlation 0.24 (Wide-angle Lens to Bladder temperature). Using the wide-angle lens, mean differences were − 11.1 °C (LoA  − 14.68 to  − 7.51),  − 11.1 °C ( − 14.3 to  − 7.9), and  − 11.2 °C ( − 15.23 to  − 7.19) for axillary, bladder, and oral comparisons respectively (Fig. 1a). With respect to the narrow-angle lens compared to the axillary, bladder and oral temperatures, mean differences were  − 7.6 °C ( − 11.2 to  − 4.0),  − 7.5 °C ( − 12.1 to  − 2.9), and  − 7.9 °C ( − 11.6 to  − 4.2) respectively. AUCs for the wide-angle lens and narrow-angle lens ranged from 0.53 to 0.70 and 0.59 to 0.79 respectively, with axillary temperature demonstrating the greatest values. Infrared thermography is a poor predictor of patient temperature as measured by existing clinical standards. It has a moderate ability to discriminate fever. It is unclear if this would be sensitive enough for infection screening purposes.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Chiu WT, et al. Infrared thermography to mass-screen suspected SARS patients with fever. Asia Pac J Public Health. 2005;17(1):26–8.CrossRef Chiu WT, et al. Infrared thermography to mass-screen suspected SARS patients with fever. Asia Pac J Public Health. 2005;17(1):26–8.CrossRef
2.
Zurück zum Zitat Aloweni FAB, et al. Evaluation of infrared technology to detect category I and suspected deep tissue injury in hospitalised patients. J Wound Care. 2019;28(Sup12):S9-s16.CrossRef Aloweni FAB, et al. Evaluation of infrared technology to detect category I and suspected deep tissue injury in hospitalised patients. J Wound Care. 2019;28(Sup12):S9-s16.CrossRef
3.
Zurück zum Zitat Kirimtat A, et al. FLIR vs SEEK thermal cameras in biomedicine: comparative diagnosis through infrared thermography. BMC Bioinformatics. 2020;21(Suppl 2):88.CrossRef Kirimtat A, et al. FLIR vs SEEK thermal cameras in biomedicine: comparative diagnosis through infrared thermography. BMC Bioinformatics. 2020;21(Suppl 2):88.CrossRef
5.
Zurück zum Zitat Sun G, et al. Applications of infrared thermography for noncontact and noninvasive mass screening of febrile international travelers at airport quarantine stations. In: Application of Infrared to Biomedical Sciences. Singapore: Springer; 2017. p. 347–58.CrossRef Sun G, et al. Applications of infrared thermography for noncontact and noninvasive mass screening of febrile international travelers at airport quarantine stations. In: Application of Infrared to Biomedical Sciences. Singapore: Springer; 2017. p. 347–58.CrossRef
6.
Zurück zum Zitat Tay MR, et al. Comparison of infrared thermal detection systems for mass fever screening in a tropical healthcare setting. Public Health. 2015;129(11):1471–8.CrossRef Tay MR, et al. Comparison of infrared thermal detection systems for mass fever screening in a tropical healthcare setting. Public Health. 2015;129(11):1471–8.CrossRef
7.
Zurück zum Zitat Priest PC, et al. Thermal image scanning for influenza border screening: results of an airport screening study. PLoS ONE. 2011;6(1):e14490.CrossRef Priest PC, et al. Thermal image scanning for influenza border screening: results of an airport screening study. PLoS ONE. 2011;6(1):e14490.CrossRef
8.
Zurück zum Zitat Nguyen AV, et al. Comparison of 3 infrared thermal detection systems and self-report for mass fever screening. Emerg Infect Dis. 2010;16(11):1710–7.CrossRef Nguyen AV, et al. Comparison of 3 infrared thermal detection systems and self-report for mass fever screening. Emerg Infect Dis. 2010;16(11):1710–7.CrossRef
11.
Zurück zum Zitat Tabata S, et al. Clinical characteristics of COVID-19 in 104 people with SARS-CoV-2 infection on the <em>diamond princess</em> cruise ship: a retrospective analysis. Lancet Infect Dis. 2020;20(9):1043–50.CrossRef Tabata S, et al. Clinical characteristics of COVID-19 in 104 people with SARS-CoV-2 infection on the <em>diamond princess</em> cruise ship: a retrospective analysis. Lancet Infect Dis. 2020;20(9):1043–50.CrossRef
12.
Zurück zum Zitat Swann OV, et al. Clinical characteristics of children and young people admitted to hospital with covid-19 in United Kingdom: prospective multicentre observational cohort study. BMJ. 2020;370:m3249.CrossRef Swann OV, et al. Clinical characteristics of children and young people admitted to hospital with covid-19 in United Kingdom: prospective multicentre observational cohort study. BMJ. 2020;370:m3249.CrossRef
13.
Zurück zum Zitat Zhu J, et al. Clinical characteristics of 3062 COVID-19 patients: a meta-analysis. J Med Virol. 2020;92(10):1902–14.CrossRef Zhu J, et al. Clinical characteristics of 3062 COVID-19 patients: a meta-analysis. J Med Virol. 2020;92(10):1902–14.CrossRef
14.
Zurück zum Zitat Chen J, et al. Clinical progression of patients with COVID-19 in Shanghai, China. J Infect. 2020;80(5):e1–6.CrossRef Chen J, et al. Clinical progression of patients with COVID-19 in Shanghai, China. J Infect. 2020;80(5):e1–6.CrossRef
15.
Zurück zum Zitat Huda, A.S.N., S. Taib, and D. Ishak. Necessity of Quantitative Based Thermographic Inspection of Electrical Equipments. 2012. Huda, A.S.N., S. Taib, and D. Ishak. Necessity of Quantitative Based Thermographic Inspection of Electrical Equipments. 2012.
16.
Zurück zum Zitat Ribeiro-Gomes K, et al. Uncooled thermal camera calibration and optimization of the photogrammetry process for UAV applications in agriculture. Sensors. 2017;17(10):2173.CrossRef Ribeiro-Gomes K, et al. Uncooled thermal camera calibration and optimization of the photogrammetry process for UAV applications in agriculture. Sensors. 2017;17(10):2173.CrossRef
17.
Zurück zum Zitat Nugent PW, Shaw JA, Pust NJ. Correcting for focal-plane-array temperature dependence in microbolometer infrared cameras lacking thermal stabilization. Opt Eng. 2013;52(6):061304.CrossRef Nugent PW, Shaw JA, Pust NJ. Correcting for focal-plane-array temperature dependence in microbolometer infrared cameras lacking thermal stabilization. Opt Eng. 2013;52(6):061304.CrossRef
18.
Zurück zum Zitat Mesas-Carrascosa FJ, Pérez-Porras F, de MeroñoLarriva JE, MenaFrau C, Agüera-Vega F, Carvajal-Ramírez F, Martínez-Carricondo P, García-Ferrer A. Drift correction of lightweight microbolometer thermal sensors on-board unmanned aerial vehicles. Remote Sens. 2018;10:615.CrossRef Mesas-Carrascosa FJ, Pérez-Porras F, de MeroñoLarriva JE, MenaFrau C, Agüera-Vega F, Carvajal-Ramírez F, Martínez-Carricondo P, García-Ferrer A. Drift correction of lightweight microbolometer thermal sensors on-board unmanned aerial vehicles. Remote Sens. 2018;10:615.CrossRef
19.
Zurück zum Zitat Chan LS, et al. Utility of infrared thermography for screening febrile subjects. Hong Kong Med J. 2013;19(2):109–15.PubMed Chan LS, et al. Utility of infrared thermography for screening febrile subjects. Hong Kong Med J. 2013;19(2):109–15.PubMed
20.
Zurück zum Zitat Moran JL, et al. Tympanic temperature measurements: are they reliable in the critically ill? A clinical study of measures of agreement. Crit Care Med. 2007;35(1):155–64.CrossRef Moran JL, et al. Tympanic temperature measurements: are they reliable in the critically ill? A clinical study of measures of agreement. Crit Care Med. 2007;35(1):155–64.CrossRef
21.
Zurück zum Zitat Dell’Isola GB, et al. Noncontact body temperature measurement: uncertainty evaluation and screening decision rule to prevent the spread of COVID-19. Sensors. 2021;21(2):346.CrossRef Dell’Isola GB, et al. Noncontact body temperature measurement: uncertainty evaluation and screening decision rule to prevent the spread of COVID-19. Sensors. 2021;21(2):346.CrossRef
22.
Zurück zum Zitat Cho KS, Yoon J. Fever screening and detection of febrile arrivals at an international airport in Korea: association among self-reported fever, infrared thermal camera scanning, and tympanic temperature. Epidemiol Health. 2014;36:e2014004.CrossRef Cho KS, Yoon J. Fever screening and detection of febrile arrivals at an international airport in Korea: association among self-reported fever, infrared thermal camera scanning, and tympanic temperature. Epidemiol Health. 2014;36:e2014004.CrossRef
23.
Zurück zum Zitat Villa E, Arteaga-Marrero N, Ruiz-Alzola J. Performance assessment of low-cost thermal cameras for medical applications. Sensors. 2020;20(5):1321.CrossRef Villa E, Arteaga-Marrero N, Ruiz-Alzola J. Performance assessment of low-cost thermal cameras for medical applications. Sensors. 2020;20(5):1321.CrossRef
24.
Zurück zum Zitat Niven DJ, Laupland KB. Pyrexia: aetiology in the ICU. Crit Care. 2016;20(1):247.CrossRef Niven DJ, Laupland KB. Pyrexia: aetiology in the ICU. Crit Care. 2016;20(1):247.CrossRef
25.
Zurück zum Zitat ASTM E1965-98. Standard specification for infrared thermometers for intermittent determination of patient temperature. West Conshohocken: ASTM International; 2016. ASTM E1965-98. Standard specification for infrared thermometers for intermittent determination of patient temperature. West Conshohocken: ASTM International; 2016.
26.
Zurück zum Zitat US Food and Drug Administration. Enforcement policy for telethermographic systems during the coronavirus disease 2019 (COVID-19) public health emergency. Silver Spring: CDRH and OPEQ; 2020. US Food and Drug Administration. Enforcement policy for telethermographic systems during the coronavirus disease 2019 (COVID-19) public health emergency. Silver Spring: CDRH and OPEQ; 2020.
27.
Zurück zum Zitat Faye E, Dangles O, Pincebourde S. Distance makes the difference in thermography for ecological studies. J Therm Biol. 2016;56:1–9.CrossRef Faye E, Dangles O, Pincebourde S. Distance makes the difference in thermography for ecological studies. J Therm Biol. 2016;56:1–9.CrossRef
28.
Zurück zum Zitat Edling L, et al. Forehead or axillary temperature measurement is not reliable. Methods and thermometers compared with rectal temperature measurement as a reference. Lakartidningen. 2010;107(46):2888–90.PubMed Edling L, et al. Forehead or axillary temperature measurement is not reliable. Methods and thermometers compared with rectal temperature measurement as a reference. Lakartidningen. 2010;107(46):2888–90.PubMed
29.
Zurück zum Zitat Williams EM, Heusch AI, McCarthy PW. Thermal screening of facial skin arterial hot spots using non-contact infrared radiometry. Physiol Meas. 2008;29(3):341–8.CrossRef Williams EM, Heusch AI, McCarthy PW. Thermal screening of facial skin arterial hot spots using non-contact infrared radiometry. Physiol Meas. 2008;29(3):341–8.CrossRef
30.
Zurück zum Zitat Khan S, et al. Comparative accuracy testing of non-contact infrared thermometers and temporal artery thermometers in an adult hospital setting. Am J Infect Control. 2020;49(5):597–602.CrossRef Khan S, et al. Comparative accuracy testing of non-contact infrared thermometers and temporal artery thermometers in an adult hospital setting. Am J Infect Control. 2020;49(5):597–602.CrossRef
31.
Zurück zum Zitat Robinson J, et al. Oesophageal, rectal, axillary, tympanic and pulmonary artery temperatures during cardiac surgery. Can J Anaesth. 1998;45(4):317–23.CrossRef Robinson J, et al. Oesophageal, rectal, axillary, tympanic and pulmonary artery temperatures during cardiac surgery. Can J Anaesth. 1998;45(4):317–23.CrossRef
32.
Zurück zum Zitat Guan W-J, et al. Clinical characteristics of coronavirus disease 2019 in China. N Engl J Med. 2020;382(18):1708–20.CrossRef Guan W-J, et al. Clinical characteristics of coronavirus disease 2019 in China. N Engl J Med. 2020;382(18):1708–20.CrossRef
33.
Zurück zum Zitat Dunn G, Roberts C. Modelling method comparison data. Stat Methods Med Res. 1999;8(2):161–79.CrossRef Dunn G, Roberts C. Modelling method comparison data. Stat Methods Med Res. 1999;8(2):161–79.CrossRef
Metadaten
Titel
Comparison of cutaneous facial temperature using infrared thermography to standard temperature measurement in the critical care setting
verfasst von
Peter Y. Chan
Andrew Tay
David Chen
Sara Vogrin
John McNeil
Ingrid Hopper
Publikationsdatum
17.06.2021
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 4/2022
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-021-00731-y

Weitere Artikel der Ausgabe 4/2022

Journal of Clinical Monitoring and Computing 4/2022 Zur Ausgabe

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Beutel versus Maschine: Beste Beatmungstechnik bei Herzstillstand gesucht

02.05.2024 Kardiopulmonale Reanimation Nachrichten

Stehen die Chancen auf eine Rückkehr der Spontanzirkulation nach Herz-Kreislauf-Stillstand bei manueller oder maschineller Beatmung besser? Und unterscheidet sich das neurologische Outcome nach der Reanimation? Das belgische Herzstillstand-Register liefert die Daten für einen direkten Vergleich zwischen Beutel und Beatmungsgerät.

Tipps für den Umgang mit Behandlungsfehlern

01.05.2024 DGIM 2024 Kongressbericht

Es ist nur eine Frage der Zeit, bis es zu einem Zwischenfall kommt und ein Behandlungsfehler passiert. Doch wenn Ärztinnen und Ärzte gut vorbereitet sind, schaffen es alle Beteiligten den Umständen entsprechend gut durch diese Krise. 

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.