Skip to main content
Erschienen in: European Radiology 7/2018

09.02.2018 | Computed Tomography

Determination of glomerular filtration rate (GFR) from fractional renal accumulation of iodinated contrast material: a convenient and rapid single-kidney CT-GFR technique

verfasst von: XiaoDong Yuan, Wei Tang, WenWei Shi, Libao Yu, Jing Zhang, Qing Yuan, Shan You, Ning Wu, Guokun Ao, Tingting Ma

Erschienen in: European Radiology | Ausgabe 7/2018

Einloggen, um Zugang zu erhalten

Abstract

Objectives

To develop a convenient and rapid single-kidney CT-GFR technique.

Methods

One hundred and twelve patients referred for multiphasic renal CT and 99mTc-DTPA renal dynamic imaging Gates-GFR measurement were prospectively included and randomly divided into two groups of 56 patients each: the training group and the validation group. On the basis of the nephrographic phase images, the fractional renal accumulation (FRA) was calculated and correlated with the Gates-GFR in the training group. From this correlation a formula was derived for single-kidney CT-GFR calculation, which was validated by a paired t test and linear regression analysis with the single-kidney Gates-GFR in the validation group.

Results

In the training group, the FRA (x-axis) correlated well (r = 0.95, p < 0.001) with single-kidney Gates-GFR (y-axis), producing a regression equation of y = 1665x + 1.5 for single-kidney CT-GFR calculation. In the validation group, the difference between the methods of single-kidney GFR measurements was 0.38 ± 5.57 mL/min (p = 0.471); the regression line is identical to the diagonal (intercept = 0 and slope = 1) (p = 0.727 and p = 0.473, respectively), with a standard deviation of residuals of 5.56 mL/min.

Conclusion

A convenient and rapid single-kidney CT-GFR technique was presented and validated in this investigation.

Key Points

• The new CT-GFR method takes about 2.5 min of patient time.
• The CT-GFR method demonstrated identical results to the Gates-GFR method.
• The CT-GFR method is based on the fractional renal accumulation of iodinated CM.
• The CT-GFR method is achieved without additional radiation dose to the patient.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Gates GF (1982) Glomerular filtration rate:estimation from fractional renal accumulation of 99mTc-DTPA (stannous). Am J Roentgenol 138:565–570CrossRef Gates GF (1982) Glomerular filtration rate:estimation from fractional renal accumulation of 99mTc-DTPA (stannous). Am J Roentgenol 138:565–570CrossRef
3.
Zurück zum Zitat Becker J, Babb J, Serrano M (2013) Glomerular filtration rate in evaluation of the effect of iodinated contrast media on renal function. Am J Roentgenol 200:822–826CrossRef Becker J, Babb J, Serrano M (2013) Glomerular filtration rate in evaluation of the effect of iodinated contrast media on renal function. Am J Roentgenol 200:822–826CrossRef
4.
Zurück zum Zitat Hackstein N, Wiegand C, Langheinrich AC et al (2003) Measurement of glomerular filtration rate by low-dose iopromide plasma clearance. Acta Radiol 44:162–165CrossRefPubMed Hackstein N, Wiegand C, Langheinrich AC et al (2003) Measurement of glomerular filtration rate by low-dose iopromide plasma clearance. Acta Radiol 44:162–165CrossRefPubMed
5.
Zurück zum Zitat Wang L, Liu B, Wu XW et al (2012) Correlation between CT attenuation value and iodine concentration in vitro: discrepancy between gemstone spectral imaging on single-source dual-energy CT and traditional polychromatic X-ray imaging. J Med Imaging Radiat Oncol 56:379–383CrossRefPubMed Wang L, Liu B, Wu XW et al (2012) Correlation between CT attenuation value and iodine concentration in vitro: discrepancy between gemstone spectral imaging on single-source dual-energy CT and traditional polychromatic X-ray imaging. J Med Imaging Radiat Oncol 56:379–383CrossRefPubMed
6.
Zurück zum Zitat Boone J, Strauss K, Cody D et al (2011) Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations. Report of AAPM Task Group 204. American Association of Physicists in Medicine, College Park Boone J, Strauss K, Cody D et al (2011) Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations. Report of AAPM Task Group 204. American Association of Physicists in Medicine, College Park
7.
Zurück zum Zitat Frennby B, Almen T (2001) Use of spiral CT and the contrast medium iohexol to determine in one session aortorenal morphology and the relative glomerular filtration rate of each kidney. Eur Radiol 11:2270–2277CrossRefPubMed Frennby B, Almen T (2001) Use of spiral CT and the contrast medium iohexol to determine in one session aortorenal morphology and the relative glomerular filtration rate of each kidney. Eur Radiol 11:2270–2277CrossRefPubMed
8.
Zurück zum Zitat Lewis M, Goh V, Beggs S et al (2014) Quality control within the multicentre perfusion CT study of primary colorectal cancer (PROSPeCT): results of an iodine density phantom study. Eur Radiol 24:2309–2318CrossRefPubMed Lewis M, Goh V, Beggs S et al (2014) Quality control within the multicentre perfusion CT study of primary colorectal cancer (PROSPeCT): results of an iodine density phantom study. Eur Radiol 24:2309–2318CrossRefPubMed
9.
Zurück zum Zitat Kok M, Mihl C, Hendriks BM et al (2016) Optimizing contrast media application in coronary CT angiography at lower tube voltage: Evaluation in a circulation phantom and sixty patients. Eur J Radiol 85:1068–1074CrossRefPubMed Kok M, Mihl C, Hendriks BM et al (2016) Optimizing contrast media application in coronary CT angiography at lower tube voltage: Evaluation in a circulation phantom and sixty patients. Eur J Radiol 85:1068–1074CrossRefPubMed
10.
Zurück zum Zitat Yuan X, Zhang J, Quan C et al (2016) A simplified whole-organ CT perfusion technique with biphasic acquisition: preliminary investigation of accuracy and protocol feasibility in kidneys. Radiology 279:254–261CrossRefPubMed Yuan X, Zhang J, Quan C et al (2016) A simplified whole-organ CT perfusion technique with biphasic acquisition: preliminary investigation of accuracy and protocol feasibility in kidneys. Radiology 279:254–261CrossRefPubMed
11.
Zurück zum Zitat Daghini E, Juillard L, Haas JA et al (2007) Comparison of mathematic models for assessment of glomerular filtration rate with electron-beam CT in pigs. Radiology 242:417–424CrossRefPubMed Daghini E, Juillard L, Haas JA et al (2007) Comparison of mathematic models for assessment of glomerular filtration rate with electron-beam CT in pigs. Radiology 242:417–424CrossRefPubMed
12.
Zurück zum Zitat Kwon SH, Saad A, Herrmann SM et al (2015) Determination of single-kidney glomerular filtration rate in human subjects by using CT. Radiology 276:490–498CrossRefPubMedPubMedCentral Kwon SH, Saad A, Herrmann SM et al (2015) Determination of single-kidney glomerular filtration rate in human subjects by using CT. Radiology 276:490–498CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Krier JD, Ritman EL, Bajzer Z et al (2001) Noninvasive measurement of concurrent single-kidney perfusion, glomerular filtration, and tubular function. Am J Physiol Ren Physiol 281:F630–F638CrossRef Krier JD, Ritman EL, Bajzer Z et al (2001) Noninvasive measurement of concurrent single-kidney perfusion, glomerular filtration, and tubular function. Am J Physiol Ren Physiol 281:F630–F638CrossRef
14.
Zurück zum Zitat Patlak CS, Blasberg RG (1985) Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations. J Cereb Blood Flow Metab 5:584–590CrossRefPubMed Patlak CS, Blasberg RG (1985) Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations. J Cereb Blood Flow Metab 5:584–590CrossRefPubMed
15.
Zurück zum Zitat Helck A, Sommer WH, Klotz E et al (2010) Determination of glomerular filtration rate using dynamic CT-angiography: simultaneous acquisition of morphological and functional information. Investig Radiol 45:387–392 Helck A, Sommer WH, Klotz E et al (2010) Determination of glomerular filtration rate using dynamic CT-angiography: simultaneous acquisition of morphological and functional information. Investig Radiol 45:387–392
16.
Zurück zum Zitat Helck A, Wessely M, Notohamiprodjo M et al (2013) CT perfusion technique for assessment of early kidney allograft dysfunction: preliminary results. Eur Radiol 23:2475–2481CrossRefPubMed Helck A, Wessely M, Notohamiprodjo M et al (2013) CT perfusion technique for assessment of early kidney allograft dysfunction: preliminary results. Eur Radiol 23:2475–2481CrossRefPubMed
17.
Zurück zum Zitat Yuan X, Zhang J, Tang K et al (2017) Determination of glomerular filtration rate with CT measurement of renal clearance of iodinated contrast material versus 99mTc-DTPA dynamic imaging "Gates" method: a validation study in asymmetrical renal disease. Radiology 282:552–560CrossRefPubMed Yuan X, Zhang J, Tang K et al (2017) Determination of glomerular filtration rate with CT measurement of renal clearance of iodinated contrast material versus 99mTc-DTPA dynamic imaging "Gates" method: a validation study in asymmetrical renal disease. Radiology 282:552–560CrossRefPubMed
18.
Zurück zum Zitat De Santo NG, Anastasio P et al (1999) Measurement of glomerular filtration rate by the 99mTc-DTPA renogram is less precise than measured and predicted creatinine clearance. Nephron 81:136–140CrossRefPubMed De Santo NG, Anastasio P et al (1999) Measurement of glomerular filtration rate by the 99mTc-DTPA renogram is less precise than measured and predicted creatinine clearance. Nephron 81:136–140CrossRefPubMed
19.
Zurück zum Zitat Ma YC, Zuo L, Zhang CL et al (2007) Comparison of 99mTc-DTPA renal dynamic imaging with modified MDRD equation for glomerular filtration rate estimation in Chinese patients in different stages of chronic kidney disease. Nephrol Dial Transplant 22:417–423CrossRefPubMed Ma YC, Zuo L, Zhang CL et al (2007) Comparison of 99mTc-DTPA renal dynamic imaging with modified MDRD equation for glomerular filtration rate estimation in Chinese patients in different stages of chronic kidney disease. Nephrol Dial Transplant 22:417–423CrossRefPubMed
20.
Zurück zum Zitat Inoue Y, Yoshikawa K, Suzuki T et al (2000) Attenuation correction in evaluating renal function in children and adults by a camera-based method. J Nucl Med 41:823–829PubMed Inoue Y, Yoshikawa K, Suzuki T et al (2000) Attenuation correction in evaluating renal function in children and adults by a camera-based method. J Nucl Med 41:823–829PubMed
21.
Zurück zum Zitat Takaki Y, Kojima A, Tsuji A et al (1993) Quantification of renal uptake of technetium-99m-DTPA using planar scintigraphy: a technique that considers organ volume. J Nucl Med 34:1184–1189PubMed Takaki Y, Kojima A, Tsuji A et al (1993) Quantification of renal uptake of technetium-99m-DTPA using planar scintigraphy: a technique that considers organ volume. J Nucl Med 34:1184–1189PubMed
Metadaten
Titel
Determination of glomerular filtration rate (GFR) from fractional renal accumulation of iodinated contrast material: a convenient and rapid single-kidney CT-GFR technique
verfasst von
XiaoDong Yuan
Wei Tang
WenWei Shi
Libao Yu
Jing Zhang
Qing Yuan
Shan You
Ning Wu
Guokun Ao
Tingting Ma
Publikationsdatum
09.02.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 7/2018
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-017-5289-7

Weitere Artikel der Ausgabe 7/2018

European Radiology 7/2018 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.