Skip to main content
Erschienen in: European Radiology 10/2010

01.10.2010 | Neuro

Dynamic MR angiography (MRA) of spinal vascular diseases at 3T

verfasst von: Maria Isabel Vargas, Duy Nguyen, Magalie Viallon, Zolt Kulcsár, Enrico Tessitore, Benedict Rilliet, Daniel Rufenacht, Karl Lovblad

Erschienen in: European Radiology | Ausgabe 10/2010

Einloggen, um Zugang zu erhalten

Abstract

Spinal magnetic resonance angiography (MRA) is difficult to perform because of the size of the spinal cord vessels. High-field MR improves resolution and imaging speed. We examined 17 patients with spinal vascular diseases with dynamic contrast-enhanced three-dimensional MR sequences. In three patients, the artery of Adamkievicz could be seen; we could also detect all arteriovenous malformations and dural fistulas. MRA has the potential to replace diagnostic spinal angiography and the latter should be used only for therapeutic purposes.
Literatur
1.
Zurück zum Zitat Lazorthes G (1983) Le systéme nerveux central, 3 edn. Masson, Paris, p 35 Lazorthes G (1983) Le systéme nerveux central, 3 edn. Masson, Paris, p 35
2.
Zurück zum Zitat Backes W, Nijenhuis R (2008) Advances in spinal cord MR angiography. AJNR Am J Neuroradiol 29:619–631CrossRefPubMed Backes W, Nijenhuis R (2008) Advances in spinal cord MR angiography. AJNR Am J Neuroradiol 29:619–631CrossRefPubMed
3.
Zurück zum Zitat Vargas MI, Delavelle J, Kohler R, Becker C, Lovblad K (2009) Brain and spine MRI artifacts at 3Tesla. J Neuroradiol 2:74–81 Vargas MI, Delavelle J, Kohler R, Becker C, Lovblad K (2009) Brain and spine MRI artifacts at 3Tesla. J Neuroradiol 2:74–81
4.
Zurück zum Zitat Vargas MI, Delavelle J, Jlassi H et al (2008) Clinical applications of diffusion tensor tractography of the spinal cord. Neuroradiology 50:25–29CrossRefPubMed Vargas MI, Delavelle J, Jlassi H et al (2008) Clinical applications of diffusion tensor tractography of the spinal cord. Neuroradiology 50:25–29CrossRefPubMed
5.
Zurück zum Zitat Mull M, Nijenhuis R, Backes W, Krings T, Wilmink J, Thron A (2007) Value and limitations of contrast-enhanced MR angiography in spinal arteriovenous malformations and dural arteriovenous fistulas. AJNR Am J Neuroradiol 7:1249–1258CrossRef Mull M, Nijenhuis R, Backes W, Krings T, Wilmink J, Thron A (2007) Value and limitations of contrast-enhanced MR angiography in spinal arteriovenous malformations and dural arteriovenous fistulas. AJNR Am J Neuroradiol 7:1249–1258CrossRef
6.
Zurück zum Zitat Hyodoh H, Shirase R, Kawaharada N et al (2009) MR angiography for detecting the artery of Adamkiewicz and its branching level from the aorta. Magn Reson Med Sci 8:159–164CrossRefPubMed Hyodoh H, Shirase R, Kawaharada N et al (2009) MR angiography for detecting the artery of Adamkiewicz and its branching level from the aorta. Magn Reson Med Sci 8:159–164CrossRefPubMed
7.
Zurück zum Zitat Petkova M, Gauvrit J, Trystram D et al (2009) Three-dimensional dynamic time-resolved contrast-enhanced MRA using parallel imaging and a variable rate k-space sampling strategy in intracranial arteriovenous malformations. J Magn Reson Imaging 29:7–12 Petkova M, Gauvrit J, Trystram D et al (2009) Three-dimensional dynamic time-resolved contrast-enhanced MRA using parallel imaging and a variable rate k-space sampling strategy in intracranial arteriovenous malformations. J Magn Reson Imaging 29:7–12
8.
Zurück zum Zitat Parmar H, Ivancevic M, Dudek N, Gandhi D, Mukherji S (2009) Dynamic MRA with four-dimensional time-resolved angiography using keyhole at 3 Tesla in head and neck vascular lesions. J Neuroophthalmol 29:119–127PubMed Parmar H, Ivancevic M, Dudek N, Gandhi D, Mukherji S (2009) Dynamic MRA with four-dimensional time-resolved angiography using keyhole at 3 Tesla in head and neck vascular lesions. J Neuroophthalmol 29:119–127PubMed
9.
Zurück zum Zitat Willinek W, Hadizadeh D, Von Falkenhausen M et al (2008) 4D time-resolved MR angiography with keyhole (4D-TRAK): more than 60 times accelerated MRA using a combination of CENTRA, keyhole, and SENSE at 3.0 T. J Magn Reson Imaging 27:1455–1460CrossRefPubMed Willinek W, Hadizadeh D, Von Falkenhausen M et al (2008) 4D time-resolved MR angiography with keyhole (4D-TRAK): more than 60 times accelerated MRA using a combination of CENTRA, keyhole, and SENSE at 3.0 T. J Magn Reson Imaging 27:1455–1460CrossRefPubMed
10.
Zurück zum Zitat Krings T, Geibprasert S (2009) Spinal dural arteriovenous fistulas. AJNR Am J Neuroradiol 4:639–648CrossRef Krings T, Geibprasert S (2009) Spinal dural arteriovenous fistulas. AJNR Am J Neuroradiol 4:639–648CrossRef
11.
Zurück zum Zitat Nijenhuis RJ, Leiner T, Cornips EM et al (2004) Spinal cord feeding arteries at MR angiography for thoracoscopic spinal surgery: feasibility study and implications for surgical approach. Radiology 2:541–547CrossRef Nijenhuis RJ, Leiner T, Cornips EM et al (2004) Spinal cord feeding arteries at MR angiography for thoracoscopic spinal surgery: feasibility study and implications for surgical approach. Radiology 2:541–547CrossRef
12.
Zurück zum Zitat Kunihiro Y, Hiroyuki N, Atsushi O et al (2003) MR angiography and CT angiography of the artery of Adamkiewicz: noninvasive preoperative assessment of thoracoabdominal aortic aneurysm. Radiographics 23:1215–1225CrossRef Kunihiro Y, Hiroyuki N, Atsushi O et al (2003) MR angiography and CT angiography of the artery of Adamkiewicz: noninvasive preoperative assessment of thoracoabdominal aortic aneurysm. Radiographics 23:1215–1225CrossRef
13.
Zurück zum Zitat Bowen B, Fraser K, Kochan J (1995) Spinal dural arteriovenous fistulas:evaluation with MR angiography. AJNR Am J Neuroradiol 16:2029–2043PubMed Bowen B, Fraser K, Kochan J (1995) Spinal dural arteriovenous fistulas:evaluation with MR angiography. AJNR Am J Neuroradiol 16:2029–2043PubMed
Metadaten
Titel
Dynamic MR angiography (MRA) of spinal vascular diseases at 3T
verfasst von
Maria Isabel Vargas
Duy Nguyen
Magalie Viallon
Zolt Kulcsár
Enrico Tessitore
Benedict Rilliet
Daniel Rufenacht
Karl Lovblad
Publikationsdatum
01.10.2010
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 10/2010
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-010-1815-6

Weitere Artikel der Ausgabe 10/2010

European Radiology 10/2010 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.